Date : 03/04/03. SAV IET N°11 V02 ed 01 Page : 1/1
SUMMARY/SOMMAIRE: Circulation pump leakage
Application on : Application mode/Modalité d’application :
Application sur : Immediately :immédiatement :
all machines If necessary /si nécessaire : Í
Periodically/périodiquement :
toutes les machines Next service call/lors d’un passage:

Problem:

Leak between the tank and the circulation pump body.

Solution:

We decided to change the old seal by a flat round seal Ref: 060 979 795A.

Old
O'Ring
seal

New flat seal


Flat seal set on the circulation
pump body.