(vi) Units for post-treatment by chlorination as well as for mechanical sludge dewatering/drying
etc shall also be included in scope of work and as per CPHEEO manual. Chlorine tonners of
minimum storage capacity to satisfy needs of minimum 15 days shall be provided on
standby.
Contractor shall also provide all ancillaries that are required for proper working of the STPs. Minimum
requirement of treatment plant units, ancillaries, equipment, instrumentation etc shall be strictly as per the latest
CPHEEO Manual. SBR tanks shall have minimum side water depth as 5.5 m. Freeboard in all the units shall be
minimum 0.5 m. Minimum requirements of processing units and equipment are given in subsequent sections.
Plant and ancillaries shall be designed to achieve desired treated water quality with easy, cost-effective and
normal operation of plant and least utilization of consumable chemicals. The Decanter shall be moving weir
type and made of SS 316.
Table 19: SEQUENCE BATCH REACTOR
Sr.No. Description Requirements
A SBR Basins
Recycle + Average flow with provision to
a) Design Flow
accommodate peak flow
b) Nos of reactors 2 Nos (Minimum)
c) Material of Construction RCC M35 in Sulphate Resistant Cement
d) Number of Cycles/day/basin 8.0 (maximum)
e) MLSS As per technology provider
f) F/M Ratio (BOD) 0.15 (Maximum) or as per technology provider.
Kg. Of Oxygen required/kg of BOD
g) 1.2 Kg. (minimum)
removed
Hydraulic Retention time of SBR
h) 14 hours (minimum)
(Aerobic) tanks
i) Aerobic SRT 10 days (minimum) or as per technology provider.
j) Specific Sludge Yield 1.1 kg / Kg BOD
k) Liquid Depth 5.5 m (maximum)
l) Free Board 0.5 m (Minimum)
B Aeration Requirements
a) BOD Oxidation Oxygen Requirement 1.2 x Inlet BOD Load
b) Nitrification Oxygen Requirement 4.5 x TKN Nitrification
c) Total Requirement BOD Oxidation + Nitrification Oxygen Requirement
No credit to be considered while designing the
d) Oxygen Credit (from De- Nitrification)
capacity Air Blowers
e) Net Oxygen Requirement Total Requirement Oxygen Credit
f) Oxygen Demand Safety Factor 10%
Alpha value for Submerged Diffuser
g) 0.6
Shall not be higher than
Beta value for Submerged Diffuser
h) 0.95
Shall not be higher than
i) Fouling Factor for Diffuser 0.8
j) Maximum Sewage Temperature 320C
k) Elevation above MSL As per approved HFD.
Min. Dissolved oxygen to be maintained
l) 2.0 mg/l
in the Aeration tank
m) Oxygen content in Air (by weight) 23%
Minimum hours of Aeration per
n) 12 hours (minimum)
day/basin
Fine bubble diffused aeration tubular/disk type.
o) Type of aeration retrievable type diffuse installation for easy
maintenance
EPDM / PU/Silicon Rubber with Anti-Microbial
p) Diffuser membrane MOC
Coating based fine bubble diffusers
q) Specific air flow rate of Diffuser(L=1.0m) 6.0 Nm3/h/unit
r) No. of diffuser As per process design
Note: Due consideration must be given in the design to the need for emptying tanks for maintenance
and repair of the aeration equipment. Intermediate wall shall be designed for empty conditions on either
side.