The pendulum Impact Tester, it is designed for conducting Izod, Charpy test The Pendulum is mounted on antifriction bearings. It has two starting positions, the upper one for Charpy & the lower one for Izod testing. On release, the pendulum swings down to brake the specimen and the energy absorbed in doing so is measured as the difference between the heights of drop before rupture of the test specimen and is read from the maximum pointer position on the dial scale. Supplied with measurement device having big size display, meter should be phone size design with voltage alert alarm with flashlight. Capable for measure the freq and voltage Features : Capacity : Charpy : 300 Joule, Izod: 170 Joule. This is low cost Impact testing machine & it is specially designed for engineering colleges. This Machine conforms to IS 3766-1977, IS 1598-1977, IS 1757-1988,IS 1499-1977 and BS 131 Part I, II, III, 01 IV. standard. This is simple & maintenance free machine. New modified Brake drum unit is provided to stop the pendulum swing instantly after test. Safety guard is provided for operator safety. Standard Accessories : Charpy Striker R2 mm - 1No. Izod Strike R0.75 mm - 1No. Charpy - Izod support Block - 1No. Specimen setting Gauges for Charpy & Izod - l Each. Allen key Set - 1 set. Instruction Manual - 1 No. 2. Brinell cum Rockwell Hardness Testing Machine 01 This is a combined hardness testing machine used to measure hardness of metals & alloys of all kinds, hard or soft, whether round, flat or irregular in shapes. Rockwell & Brinell method is used for checking hardness on metals & alloys of all kinds Brinell hardness is also checked on non-ferrous materials like Cast iron, Aluminum, etc. Manual weight selection with automatic zero setting dial gauge. Rockwell test minor load is 10 kgf & major loads are 60,100,150 kgf. Brinell test for major load is 187.5 & Rockwell hardness scales such as HRA, HRB, HRC, etc. Brinell hardness scale such as HB is obtained by using different types of indentors ( Diamond / Ball ). Test height x Throat is – 215 x 132 mm. Test Loads (Kgf) 60, 100, 150 (Rockwell) 187.5, 250 (Brinell) Initial Loads (Kgf). 10 Nett Weigth (kg.) (Approx.) 75 2.5 mm Steel Balls 5 No. 5 mm Steel Balls 5 No. Standard Accessories 1) Flat Table of 50 mm Dia. 1 No. 2) Vee Table for Specimen - 50 mm Dia. 1 No. 3) Diamond Indentor 1 No. 4) 1/16’’ Ball Indentor 1 No. 5) Rockwell Hardness Test Block 1 No. 6) Brinell Hardness Test Block 1 No. 7) Instruction Manual 1 Book 8) 2.5 mm Steel Balls 5 No. 9) 5 mm Steel Balls 5 No. 10) 1/16” Steel Ball 5 No. Brinell Microscope 1 No. Preference will be given to ISO 9001:2015 & CE certified Manufacturer/suppliers' who can ensure the manufacturing of the machine as per the required testing standards/BS/BlS/ASTM standards and within the specified tolerance limits. 3. FATIGUE TESTING MACHINE Fatigue Testing Machine This machine is used to test the fatigue strength of materials and to draw S-N diagram by research institutes, laboratories, material manufactures and various industries. This is a rotating beam type machine in which load is applied in reversed bending fashion. The standard 8 mm dia. specimen is held in special holders at its ends and loaded such that it experiences a uniform bending moment. The specimen is rotated at 4200 rpm by a motor. A completer cycle of reversed stresses in all fibers of the specimen is produced during each revolution. The bending moment is applied with a lever system and can be easily changed by moving a weight over the lever. Total number of revolutions at which the specimen fails are recorded by a Digital counter. An interlocking system puts off the motor at specimen failure. Supplied with measurement device having big size display, meter should be phone size design with voltage alert alarm with flashlight. Capable for measure the freq and voltage Machine meets requirements of IS 5075 - 1969 1. Light weight, compact size, simple design. 2. Table model, no need of foundation. 3. Simple lever system of changing load. 4. Accurately calibrated as per IS 5075. 01 5. Calibration in Nm TECHNICAL SPECIFICATIONS 1. Maximum Bending moment kg cm 200 2. Bending moment adjustable kg cm 25 - 200 3. Ranges I-kg cm 25 – 125, II-kg cm 125-200 4. Gripping dia of specimen mm -12 5. Testing dia of specimen mm 8 6. Rotating speed rpm 4200 7. Accuracy of applied bending moment. 8. Digital counter No. of digits 8 9. Power required HP 0.5 10. Main supply 3ph, 440, V50 Hz, A.C. 11. Overall Size (approx) mm 1000 L. X. 12. Weight (approx) kg 120 Preference will be given to ISO 9001:2015 & CE certified Manufacturer/suppliers' who can ensure the manufacturing of the machine as per the required testing standards/BS/BlS/ASTM standards and within the specified tolerance limits. 4. SPRING TESTING MACHINE Spring testing machines are used for quick and accurate testing of tension and compression springs. The machine comprises of two hard crome plated columns with fine cut single screw with hand wheel for manual loading and unloading arrangement. The machine uses a high precision load cell for measurement of force. For displacement measurement, mechanical linear scale or digital venire caliper or rotary encoder is used. Measuring system of machine is based on latest microprocessor based electronics with tare facility. Supplied with measurement device having big size display, meter should be phone size design with voltage alert alarm with flashlight. Capable for measure the freq and voltage 01 Microprocessor based unit. Force Measurement Accuracy ±1 % of indicated load or 0.5 % of full load value whichever is higher. Quick and accurate measurement. Interchangeable load cells. Modulus data for load & displacement. Maximum Capacity 20 kg, 10 kg, 5 kg, Width between Columns 160 mm, Maximum Cross Head Travel 160 mm Preference will be given to ISO 9001:2015 & CE certified Manufacturer/suppliers' who can ensure the manufacturing of the machine as per the required testing standards/BS/BlS/ASTM standards and within the specified tolerance limits. 5. TORSION TESTING MACHINE 01 Torsion Testing Machine It is designed for conducting torsion and twist on various metal wires, tubes, sheet materials torque measurement is by pendulum dynamometer system. • Torque ranges can be adjusted by auto torque selector. • Torque can be applied to specimen by geared motor through gear box. • Autographic recorder gives the relation between torque and angle of twist. • The accuracy of torque indication is ±1of the true torque. Max. Torque Capacity100 nm Torque Ranges 100,50,20 No. of div. on Dial 500 Torsion Speed1.5 Clearance between Grips 0-420 Grips for Round specimens 4-8 8-12 Grips for flat Specimens width mm2-8, 25 Motor (400-440 V, 3 Phases & 50 Hz.)v 0.5 Preference will be given to ISO 9001:2015 & CE certified Manufacturer/suppliers' who can ensure the manufacturing of the machine as per the required testing standards/BS/BlS/ASTM standards and within the specified tolerance limits.