You are on page 1of 1

J PAN TUBULAR COMPONENTS PRIVATE LIMITED(UNIT-III) (C2)

Plot # 120, 2nd Phase, Jigani Ind. Area, Jigani, Anekal Taluk,BANGLORE, KARNATAKA

Inspection Report Inspection. No PM-6 / 6216

Vendor Code Drawing No.: Rec. No PM-6 dt.06/03/23

Vendor Name TC No.: 0 Bill No dt.


Heat No.: 0 Batch No. C223C6-1-1
Item Code 875-4547
Item Name Quantity 20.00 NOS/Rej : 0.00 NOS
Gasket
Inspection Type Inspection Item Specifications Instrument Target USL LSL OBESERVATIONS Sample Size 2
Value
01 02 03 04 05 06 07 08 09 10 11 12 13

OD DVC 52±0.1 52.0 52.10 51.90 52 52.1

ID DVC 30±0.1 30 30.10 29.90 30 30

THICKNESS DVC 3±0.1 3 3.10 2.90 3 3.1

APPEARANCE VISUAL NO FLASHES & OK 0.00 0.00 OK OK


BURRS
ALLOWED

Other Ref.:
(Prepared B1119SRAJESH (Q.C by) Aircon QC.DATE : 06/03/23 16:29 (Approved by)
by) Production INSPECTION UNIT MM INCH