.1.1ﻳﺗﺿﻣﻥ ﺍﻟﻘﺳﻡ
ﺃﻟﻭﺍﺡ ﻋﺯﻝ ﺣﺭﺍﺭﻱ ﺃﻓﻘﻳﺔ ﻭﺭﺃﺳﻳﺔ ﺣﺳﺏ ﺍﻟﻣﺣﺩﺩ ﺑﺎﻟﺭﺳﻭﻣﺎﺕ ﻭﺍﻟﻣﻭﺻﻑ ﻓﻲ ﻫﺫﺍ ﺍﻟﻘﺳﻡ.
.1.2ﺍﻟﻣﺭﺍﺟﻊ
ﺍﻟﺟﻣﻌﻳﺔ ﺍﻷﻣﺭﻳﻛﻳﺔ ﻟﻼﺧﺗﺑﺎﺭ ﻭﺍﻟﻣﻭﺍﺩ ASTM ﺃ-
ﻁﺭﻕ ﺍﺧﺗﺑﺎﺭ ﺍﻟﻧﻔﺎﺫ ﻟﻠﻣﻭﺍﺩ ﺍﻟﺑﻳﺗﻭﻣﻳﻧﻳﻪ ASTM D5
ﻁﺭﻕ ﺍﺧﺗﺑﺎﺭ ﻧﻘﻁﺔ ﺍﻟﻠﻳﻭﻧﺔ ﻟﻸﺳﻔﻠﺕ -ﺟﻬﺎﺯ ﺍﻟﺣﻠﻘﺔ ﻭﺍﻟﻛﺭﺓ ASTM D36
ﺍﻟﺩﻫﺎﻧﺎﺕ ﺍﻷﻭﻟﻳﺔ ﺍﻟﻣﺳﺗﺧﺩﻣﺔ ﻣﻊ ﺍﻷﺳﻔﻠﺕ ﻓﻰ ﻋﺯﻝ ﺍﻟﻣﻳﺎﻩ ﻭﻋﺯﻝ ﺍﻟﺭﻁﻭﺑﺔ ASTM D41
ﻋﻳﻧﺎﺕ ﻭﺍﺧﺗﺑﺎﺭ ﺍﻟﻳﺎﻑ ﻟﺑﺎﺩ ﻣﻧﺳﻭﺟﺔ ﻣﺷﺑﻌﺔ ﺑﻣﻭﺍﺩ ﺑﻳﺗﻭﻣﻧﻳﻪ ﻟﻼﺳﺗﺧﺩﺍﻡ ﻓﻰ ASTM D146
ﺃﻋﻣﺎﻝ ﻋﺯﻝ ﺍﻟﻣﻳﺎﻩ ﻟﻸﺳﻘﻑ
ﻁﺭﻳﻘﺔ ﺍﺧﺗﺑﺎﺭ ﺧﻭﺍﺹ ﺍﻟﻣﻁﺎﻁ :ﺗﺄﺛﻳﺭ ﺍﻟﺳﻭﺍﺋﻝ ASTM D471
ﻁﺭﻳﻘﺔ ﺍﺧﺗﺑﺎﺭ ﺍﻣﺗﺻﺎﺹ ﺍﻟﺩﺍﺋﻥ ﻟﻠﻣﺎء ASTM D570
ﻁﺭﻳﻘﺔ ﺍﺧﺗﺑﺎﺭ ﺧﻭﺍﺹ ﺍﻟﺷﺩ ﻟﻠﺩﺍﺋﻥ ASTM D638
ﻁﺭﻳﻘﺔ ﺍﺧﺗﺑﺎﺭ ﻗﻭﺓ ﺷﺩ ﺍﻟﻘﻁﻊ ﻟﻠﻭﺭﻕ ﻭﺃﻟﻭﺍﺡ ﺍﻟﻭﺭﻕ. ASTM D828
ﻁﺭﻳﻘﺔ ﺍﺧﺗﺑﺎﺭ ﻣﻘﺎﻭﻣﺔ ﺍﻻﺧﺗﺑﺎﺭ ﺍﻻﺑﺗﺩﺍﺋﻳﺔ ﻷﻏﺷﻳﺔ ﻭﺷﺭﺍﺋﺢ ﺍﻟﻠﺩﺍﺋﻥ ASTM D1004
ﻁﺭﻳﻘﺔ ﺍﺧﺗﺑﺎﺭ ﻧﻔﺎﺫ ﺑﺧﺎﺭ ﺍﻟﻣﺎء ﻟﻠﻣﻭﺍﺩ ASTM E96
ﻁﺭﻳﻘﺔ ﺍﺧﺗﺑﺎﺭ ﻣﻘﺎﻭﻣﺎﺕ ﺍﻟﺑﺧﺭ ﺍﻟﻣﺳﺗﺧﺩﻣﺔ ﺑﻣﻼﻣﺳﺔ ﺍﻷﺭﺽ ﺗﺣﺕ ﺍﻟﺑﻼﻁﺎﺕ ASTM E154
ﺍﻟﺧﺭﺳﺎﻧﻳﺔ ﻭﻋﻠﻰ ﺍﻟﺟﺩﺭﺍﻥ ﺃﻭ ﻛﻐﻁﺎء ﺃﺭﺿﻳﺔ
.1.3ﺍﻟﺗﻘﺩﻳﻣﺎﺕ
ﺑﻳﺎﻧﺎﺕ ﺍﻟﻣﻧﺗﺞ :ﺗﻘﺩﻡ ﺑﻳﺎﻧﺎﺕ ﻣﻧﺗﺞ ﺍﻟﺻﺎﻧﻊ ﻭﺍﻟﻌﻳﻧﺎﺕ ﻭﺇﺟﺭﺍءﺍﺕ ﺍﻟﺗﺭﻛﻳﺏ ﻻﻋﺗﻣﺎﺩ ﺍﻟﻣﻬﻧﺩﺱ.
.1.5ﺿﻣﺎﻥ ﺍﻟﺟﻭﺩﺓ
.1.5.1ﺍﻟﻣﻘﺎﻭﻣﺔ ﺍﻟﺣﺭﺍﺭﻳﺔ :ﻋﻧﺩﻣﺎ ﺗﺣﺩﺩ ﺧﻭﺍﺹ ﺍﻟﻣﻘﺎﻭﻣﺔ ﺍﻟﺣﺭﺍﺭﻳﺔ ﻟﻣﻭﺍﺩ ﺍﻟﻌﺯﻝ ﺍﻟﺣﺭﺍﺭﻱ ﺑﻘﻳﻡ –
ﻣﻘﺎﻭﻣﺔ R-Valuesﻓﺈﻧﻬﺎ ﺗﻣﺛﻝ ﻣﻌﺩﻝ ﺍﻟﺳﺭﻳﺎﻥ ﺍﻟﺣﺭﺍﺭﻱ ﺧﻼﻝ ﺍﻟﻣﻭﺍﺩ ﺫﺍﺕ ﺍﻟﺳﻣﻙ ﺍﻟﻣﺣﺩﺩ
ﻭﺍﻟﻣﻘﺎﺳﺔ ﺑﻁﺭﻳﻘﺔ ﺍﻻﺧﺗﺑﺎﺭ ﺍﻟﻣﺫﻛﻭﺭﺓ ﺑﻣﺭﺍﺟﻊ ﺍﻟﻣﻭﺍﺩ ﺍﻟﻘﻳﺎﺳﻳﺔ ﺃﻭ ﺣﺳﺏ ﻣﺎ ﻳﺣﺩﺩ ﺧﻼﻑ ﺫﻟﻙ.
.1.5.2ﺧﻭﺍﺹ ﺃﺩﺍء ﺍﻟﺣﺭﻳﻖ :ﺗﻭﺭﺩ ﻣﻭﺍﺩ ﻋﺯﻝ ﺣﺭﺍﺭﻱ ﻣﻁﺎﺑﻘﺔ ﻟﺧﻭﺍﺹ ﻣﻘﺎﻭﻣﺔ ﺍﻟﺣﺭﻳﻖ ﺍﻟﻣﺩﻭﻧﺔ
ﻋﻠﻰ ﻛﻝ ﻣﺎﺩﺓ ﺃﻭ ﻣﺟﻣﻭﻋﺔ ﻳﻛﻭﻥ ﺍﻟﻌﺯﻝ ﺍﻟﺣﺭﺍﺭﻱ ﺟﺯء ﻣﻧﻬﺎ ﻭﺍﻟﺗﻲ ﻳﺗﻡ ﺗﺣﺩﻳﺩﻫﺎ ﺑﺎﻻﺧﺗﺑﺎﺭ
ﻁﺑﻘﺎ ﻟﻠﻁﺭﻕ ﺍﻟﻣﺣﺩﺩﺓ ﺃﺩﻧﺎﻩ.
ﺧﻭﺍﺹ ﺍﺣﺗﺭﺍﻕ ﺍﻟﺳﻁﺢASTM E 84 : ﺃ.
ﻣﻌﺩﻻﺕ ﻣﻘﺎﻭﻣﺔ ﺍﻟﺣﺭﻳﻖASTM E 119 : ﺏ.
ﺧﻭﺍﺹ ﻗﺎﺑﻠﻳﺔ ﺍﻻﺣﺗﺭﺍﻕASTM E 136 : ﺝ.
.1.6ﺍﺷﺗﺭﺍﻁﺎﺕ ﺍﻟﻌﻣﻝ
.1.6.1ﺗﻘﺎﺱ ﺃﻋﻣﺎﻝ ﺍﻟﻁﺑﻘﺎﺕ ﺍﻟﻌﺎﺯﻟﺔ ﻟﻠﺭﻁﻭﺑﺔ ﺣﺳﺏ ﺍﻟﻣﺳﺎﻗﻁ ﺍﻷﻓﻘﻳﺔ ﻟﻣﺳﻁﺣﺎﺕ ﺍﻟﺧﺭﺳﺎﻧﺔ
ﺍﻟﻣﻌﺯﻭﻟﺔ ﺍﻷﻓﻘﻳﺔ ﺑﺩﻭﻥ ﺍﺣﺗﺳﺎﺏ ﺍﻟﻭﺯﺭﺍﺕ ﻋﻧﺩ ﺍﻟﺩﺭﺍﻭﻱ ﻭﺍﻟﺣﻭﺍﺋﻁ.
.1.6.2ﻳﺟﺏ ﺗﻧﻅﻳﻑ ﺍﻷﺳﻘﻑ ﺃﻭ ﺍﻷﺳﻁﺢ ﺟﻳﺩﺍ ﻣﻥ ﺟﻣﻳﻊ ﺍﻷﻭﺳﺎﺥ ﻭﺍﻷﺗﺭﺑﺔ ﻭﻣﺧﻠﻔﺎﺕ ﺍﻟﺻﺑﺔ ﻗﺑﻝ
ﺍﻟﺑﺩء ﻓﻲ ﺃﻋﻣﺎﻝ ﺍﻟﻁﺑﻘﺎﺕ ﺍﻟﻌﺎﺯﻟﺔ.
.2.1.1ﺍﻟﻭﺍﺡ ﺍﻟﻔﻭﻡ ﺍﻻﺯﺭﻕ ﺍﻟﻣﺿﻐﻭﻁ )ﺃﺩﻓﻰ ﻓﻭﻡ( ﺑﺳﻣﻙ 50ﻣﻡ ﻭﻛﺛﺎﻓﺔ 36ﻛﺟﻡ/ﻣﺗﺭ ﺍﻟﻣﻛﻌﺏ
ﻭﻁﺑﻘﺎ ً ﻟﺑﺎﻗﻲ ﺍﻟﻣﻭﺍﺻﻔﺎﺕ ﺍﻟﻔﻧﻳﺔ ﺍﻟﺧﺎﺻﺔ ﺑﺎﻟﺷﺭﻛﺔ ﺍﻟﻣﻧﺗﺟﺔ.
.2.1.2ﻟﻳﺎﺳﺔ ﺃﺳﻣﻧﺗﻳﺔ ﺳﻣﻙ 3ﺳﻡ ﺑﻧﺳﺑﺔ 300ﻛﺟﻡ ﺃﺳﻣﻧﺕ ﻟﻛﻝ ﻣﺗﺭ ﻣﻛﻌﺏ ﺭﻣﻝ ﻣﺿﺎﻓﺎ ﺍﻟﻳﻬﺎ ﻣﺎﺋﺔ
ﻛﻳﻠﻭ ﺟﺭﺍﻡ ﻣﺣﻠﻭﻝ ﺑﻳﺗﻭﻣﻳﻥ ﺃﻭ ﻣﺎ ﻳﻣﺎﺛﻠﻪ ﻟﻠﻣﺗﺭ ﺍﻟﻣﻛﻌﺏ ﻭﺗﺧﻠﻁ ﺍﻟﻧﺳﺏ ﺍﻟﻣﺫﻛﻭﺭﺓ )ﻋﻠﻰ
ﺍﻟﺑﺎﺭﺩ( ﺛﻡ ﺗﻔﺭﺵ ﻓﻭﻕ ﺇﺣﺩﻯ ﺍﻟﻁﺑﻘﺗﻳﻥ ﻋﺎﻟﻳﺔ ﻭﻳﺗﻡ ﺗﺧﺷﻳﻥ ﺍﻟﺳﻁﺢ ﺍﻟﻧﻬﺎﺋﻲ.
.2.1.3ﻁﺑﻘﺔ ﻋﺎﺯﻟﺔ ﻟﻠﺣﺭﺍﺭﺓ ﺭﺃﺳﻳﺔ ﻣﻥ ﺍﻟﻭﺍﺡ ﺍﻟﻔﻭﻡ ﺍﻻﺯﺭﻕ ﺍﻟﻣﺿﻐﻭﻁ )ﺃﺩﻓﻰ ﻓﻭﻡ( ﺑﺳﻣﻙ 50ﻣﻡ
ﻭﻛﺛﺎﻓﺔ 35ﻛﺟﻡ/ﻣﺗﺭ ﺍﻟﻣﻛﻌﺏ ﻭﺗﻭﺿﻊ ﺍﻟﻁﺑﻘﺔ ﺍﻟﻌﺎﺯﻟﺔ ﺭﺃﺳﻳﺎ ﺑﻳﻥ ﺣﻭﺍﺋﻁ ﻣﺑﺎﻧﻲ ﺍﻟﻭﺍﺟﻬﺎﺕ
ﺍﻟﺧﺎﺭﺟﻳﺔ ﻣﻊ ﺍﻟﺗﺛﺑﻳﺕ ﺟﻳﺩﺍ ﺑﺎﻟﺧﺭﺩﻭﺍﺕ ﺍﻟﻼﺯﻣﺔ ﻟﻬﺎ ﺣﺳﺏ ﻧﻅﺎﻡ ﺍﻟﺷﺭﻛﺔ ﺍﻟﻣﻧﺗﺟﺔ ﻟﻬﺎ.
.3.1ﺍﻟﻣﻌﺎﻳﻧﺔ
.3.1.1ﻳﺗﻡ ﺍﺧﺗﺑﺎﺭ ﺍﻟﻣﻧﺎﻁﻖ ﺍﻟﻣﺟﺩﻭﻟﺔ ﻟﻭﺿﻊ ﺍﻟﻌﺯﻝ ﻭﺍﻷﻣﺎﻛﻥ ﺍﻟﻣﺣﺩﺩﺓ ﻟﻠﻌﺯﻝ ﻟﻠﺗﺄﻛﺩ ﻣﻥ ﻣﻼﺋﻣﺔ
ﺍﻟﻌﻣﻖ ﻻﺳﺗﻘﺑﺎﻝ ﺍﻟﻣﻭﺍﺩ.
.3.2ﺍﻟﺗﺭﻛﻳﺏ
.3.2.1ﺗﻭﺿﻊ ﻭﺣﺩﺍﺕ ﺍﻟﻌﺯﻝ ﻋﻠﻰ ﺍﻟﻁﺑﻘﺔ ﺍﻟﺳﻔﻠﻳﺔ ﺑﺎﻟﻁﺭﻕ ﺍﻟﻣﻁﺎﺑﻘﺔ ﻟﺗﻭﺻﻳﺎﺕ ﺍﻟﺻﺎﻧﻊ.