You are on page 1of 79

NEMO|etc.

Certificate of Authorization #32455


353 Christian Street, Unit #13
Oxford, CT 06478
(203) 262-9245
ENGINEER EVALUATE TEST CONSULT
EVALUATION REPORT BY FLORIDA P.E.
CertainTeed, LLC Evaluation Report 3520.03.04-R30
20 Moores Road FL2533-R29
Malvern, PA 19355 Date of Issuance: 09/19/2005
(610) 893-5400 Revision 30: 01/26/2023
SCOPE:
This Evaluation Report is issued under F.A.C. Rule 61G20-3 and the applicable rules and regulations governing the use of construction
materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product
under the Florida Building Code. The product described herein has been evaluated for compliance with the 7th Edition (2020) Florida
Building Code sections noted herein.

DESCRIPTION: Flintlastic® Modified Bitumen Roof Systems for use in FBC non-HVHZ jurisdictions
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality
Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change. Acceptance of our
Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any changes to the product(s), the Quality
Assurance or the production facility location(s). NEMO ETC, LLC requires a complete review of its Evaluation Report relative to
updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words “NEMO P.E. Evaluated” may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors
and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 5, plus a 74-page Appendix.
Prepared by:
Digitally signed
by Robert
Nieminen
Date: 2023.01.26
'14:12:41 -05'00
CERTIFICATION OF INDEPENDENCE:
1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
© 2019 NEMO ETC, LLC
NEMO|etc.
ROOFING SYSTEMS EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Modified Bitumen Roof Systems
Product Approval Method: Method 1, Option D – Codified Material, Evaluation by Engineer
Compliance Statement: Flintlastic® Modified Bitumen Roof Systems, as produced by CertainTeed, LLC, have
demonstrated compliance with the following sections of the 7th Edition (2020) Florida Building Code through
testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and
Limitations of Use set forth herein.

2. STANDARDS:
SECTION PROPERTY STANDARD YEAR
1504.3.1 Wind resistance FM 4474 2011
1504.6 Accelerated weathering ASTM G155 2013
1504.7 Impact resistance FM 4470 2016
1507.1.1 Material standard ASTM D1970 2015
1507.10.2 Material standard ASTM D41 2011
1507.10.2 Material standard ASTM D2178 2015
1507.10.2 Material standard ASTM D4601 2012
1507.10.2 Material standard ASTM D4897 2009
1507.11.2 Material standard ASTM D6163 2015
1507.11.2 Material standard ASTM D6164 2011
1507.11.2 Material standard ASTM D6222 2011
1507.11.2 Material standard ASTM D6509 2015

3. REFERENCES:
ENTITY EXAMINATION REFERENCE DATE ENTITY EXAMINATION REFERENCE DATE
ERD (TST6049) ASTM G155 C31410.06.10-2-R1 01/10/11 FM (TST1867) FM 4470 3W0A2.AM 03/17/93
ERD (TST6049) ASTM G155 C31410.12.13 12/05/13 FM (TST1867) FM 4470 3W0A3.AM 03/17/93
ERD (TST6049) ASTM D6222 CTR-SC11145.09.16-7A 09/19/16 FM (TST1867) FM 4470 1Z4A6.AM 09/11/96
NEMO (TST6049) ASTM D4601 4q-CTR-20-SSMBB-03.A 02/10/21 FM (TST1867) FM 4470 3Y8A1.AM 09/30/96
NEMO (TST6049) ASTM D4897 4q-CTR-21-SSMBB-03.A 10/05/21 FM (TST1867) FM 4470 2D5A9.AM 06/22/99
NEMO (TST6049) ASTM D2178 4q-CTR-22-SSMBB-04.B 11/21/22 FM (TST1867) FM 4470 3009502 12/12/00
NEMO CERT (CER13842) Various Various Current FM (TST1867) FM 4470 3008869 03/19/01
PRI (TST5878) ASTM D6164, G155 CTC-093-02-01 08/08/11 FM (TST1867) FM 4470 3009610 10/15/01
PRI (TST5878) ASTM D4601 CTC-124-02-01 03/12/12 FM (TST1867) FM 4470 3006025 12/28/01
PRI (TST5878) ASTM D6509 CTC-116-02-01 04/04/12 FM (TST1867) FM 4470 3012321 07/29/02
PRI (TST5878) ASTM D6164 CTC-131-02-01 06/08/12 FM (TST1867) FM 4470 3009814 09/06/02
PRI (TST5878) ASTM D6164 CTC-190-02-01 11/27/13 FM (TST1867) FM 4470 3014502 04/04/03
PRI (TST5878) ASTM D6164 CTC-354-02-01 05/11/18 FM (TST1867) FM 4470 3015444 07/11/03
PRI (TST5878) ASTM D41 256T0074 11/11/21 FM (TST1867) FM 4470 3014692 08/05/03
ERD (TST6049) FM 4470 3504.06.01-1 06/05/01 FM (TST1867) FM 4470 3014751 08/27/03
ERD (TST6049) FM 4470 3513.08.02 08/15/02 FM (TST1867) FM 4470 3018579 10/09/03
ERD (TST6049) FM 4470 03515.07.03 07/22/03 FM (TST1867) FM 4470/4474 3020703 07/30/04
ERD (TST6049) FM 4470 3519.12.03 12/22/03 FM (TST1867) FM 4470/4474 3021759 06/03/05
ERD (TST6049) FM 4470/4474 3522.07.04 07/28/04 FM (TST1867) FM 4470/4474 3022038 04/05/06
ERD (TST6049) FM 4470/4474 02843.02.05-11 02/10/05 FM (TST1867) FM 4470/4474 3023458 07/18/06
ERD (TST6049) FM 4470/4474 3533.01.06 01/06/06 FM (TST1867) FM 4470/4474 3026128 08/04/06
ERD (TST6049) FM 4470/4474 4674.11.01-1 03/21/06 FM (TST1867) FM 4470/4474 3024311 11/01/06
ERD (TST6049) FM 4470/4474 3521.07.04-R1 10/26/07 FM (TST1867) FM 4470/4474 3025766 11/13/06
ERD (TST6049) FM 4470/4474 02762.03.05-R1 12/10/07 FM (TST1867) FM 4470/4474 3028410 02/19/07
ERD (TST6049) FM 4470/4474 02764.09.05-R1 12/10/07 FM (TST1867) FM 4470/4474 3026964 07/25/07
ERD (TST6049) FM 4470/4474 P6860.06.07-R1 09/10/09 FM (TST1867) FM 4470/4474 3031262 11/30/07
ERD (TST6049) FM 4470/4474 C8370.08.08-R1 10/05/09 FM (TST1867) FM 4470/4474 3031199 12/23/08
ERD (TST6049) FM 4470/4474 C30310.12.09 12/17/09 FM (TST1867) FM 4470/4474 3032172 06/12/09
ERD (TST6049) FM 4470/4474 C30560.03.10 03/18/10 FM (TST1867) FM 4470/4474 3037127 01/11/10
ERD (TST6049) FM 4470/4474 C31420.08.10 09/21/10 FM (TST1867) FM 4470/4474 3039848 12/02/11
ERD (TST6049) FM 4470/4474 C33980.12.10 12/22/10 FM (TST1867) FM 4470/4474 3046104 08/13/13
ERD (TST6049) FM 4470/4474 C33830.02.11 02/08/11 FM (TST1867) FM 4470/4474 3048520 09/19/13
ERD (TST6049) Criticality C35500.02.11 02/09/11 FM (TST1867) FM 4470/4474 3055491 12/05/16
ERD (TST6049) FM 4470/4474 C37820.07.12 07/24/12 FM (TST1867) FM 4470/4474 3063970 09/14/18

NEMO ETC, LLC Evaluation Report 3520.03.04-R30


Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) FL2533-R29
Flintlastic® Modified Bitumen Roof Systems Revision 30: 01/26/2023
Page 2 of 5
NEMO|etc.
ENTITY EXAMINATION REFERENCE DATE ENTITY EXAMINATION REFERENCE DATE
ERD (TST6049) FM 4470/4474 C37830.07.12 07/26/12 FM (TST1867) FM 4470/4474 PR452974 01/15/20
ERD (TST6049) Criticality C42110.08.12 08/13/12 FM (TST1867) FM 4470/4474 3061328 04/13/20
ERD (TST6049) FM 4470/4474 C39670.08.12 08/20/12 FM (TST1867) FM 4470/4474 PR458318 04/12/21
ERD (TST6049) FM 4470/4474 C42280.08.12 08/20/12 FM (TST1867) FM 4470/4474 PR457312 04/20/21
ERD (TST6049) Criticality A35880.04.12-R1 10/26/12 FM (TST1867) FM 4470 RR228436 06/01/21
ERD (TST6049) FM 4470/4474 C44580.07.13 07/25/13 NEMO Traceability FBC Cross-Listing 07/02/21
ERD (TST6049) FM 4470/4474 C46090.11.13-A 11/20/13 NEMO (TST11294) FM 4474 2L-CTR-18-001.04.19.A 06/24/19
ERD (TST6049) FM 4470/4474 C45620.03.14 03/27/14 NEMO (TST6049) FM 4474 4L-CTR-18-002.09.18-1 09/21/18
ERD (TST6049) FM 4470/4474 C46760.06.14 06/19/14 NEMO (TST6049) FM 4474 4L-CTR-18-002.09.18-2 09/21/18
ERD (TST6049) FM 4470/4474 C47320.03.14-R1 04/01/15 NEMO (TST6049) FM 4474 4L-CTR-18-002.10.18 10/22/18
ERD (TST6049) FM 4470/4474 CTR-SC8995.10.15 10/14/15 NEMO (TST6049) FM 4474 4L-CTR-18-002.03.19A 03/07/19
ERD (TST6049) FM 4470/4474 CTR-SC9935.01.16 01/14/16 NEMO (TST6049) FM 4474 4L-CTR-18-002.04.19B 04/12/19
ERD (TST6049) FM 4470 CTR-SC9920.01.16 01/20/16 NEMO (TST6049) FM 4474 4a-CTR-19-LSWUS-04.A 08/05/19
ERD (TST6049) FM 4470/4474 CTR-SC10420.01.16 01/25/16 NEMO (TST6049) FM 4474 4a-CTR-19-LSWUS-03.B 01/27/20
ERD (TST6049) FM 4470/4474 CTR-SC11590.08.16 09/06/16 NEMO (TST6049) FM 4474 4a-CTR-19-LSWUS-05.A 02/05/20
ERD (TST6049) FM 4470/4474 CTR-SC9175.09.16-1 09/06/16 NEMO (TST6049) FM 4474 4a-CTR-19-LSWUS-02.A 02/28/20
ERD (TST6049) FM 4470/4474 CTR-SC9175.09.16-1 09/06/16 NEMO (TST6049) Criticality 4p-ICP-19-SSLAP-04.A 05/28/20
ERD (TST6049) FM 4470/4474 CTR-SC12255.12.16 12/27/16 NEMO (TST6049) FM 4474 4a-CTR-20-LSWUS-01.B 06/26/20
ERD (TST6049) Criticality ICP-SC15630.09.17 09/06/17 NEMO (TST6049) Criticality 4i-CTR-20-SSCRT-04.A 06/16/21
ERD (TST6049) Criticality ICP-SC16225.09.17 09/06/17 NEMO (TST6049) Criticality 4i-CTR-21-SSCRT-02.A 06/21/21
ERD (TST6049) FM 4474 CTR-SC15775.17 09/13/17 NEMO (TST6049) Criticality 4i-CTR-21-SSCRT-03.A 07/06/21
FM (TST1867) FM 4470 0E3A2.AM 03/30/82 NEMO (TST6049) Criticality 4i-CTR-21-SSCRT-01.A 07/12/21
FM (TST1867) FM 4470 3W0A4.AM 03/16/93 NEMO (TST6049) Criticality 4i-CRT-21-SSCRT-04.A 01/04/22
FM (TST1867) FM 4470 3W0A2.AM 03/17/93 NEMO (TST6049) FM 4474 4a-CTR-21-LSWUS-01.A 07/13/22
FM (TST1867) FM 4470 3W0A3.AM 03/17/93 PRI (TST5878) FM 4474 2111T0009 05/13/21
UL (QUA9625) QA Service Confirmation 08/08/22
UL (QUA9625) QA Florida BCIS Current

4. PRODUCT DESCRIPTION:
This Evaluation Report covers Flintlastic® Modified Bitumen Roof Systems installed in accordance with
CertainTeed, LLC published installation instructions and the Limitations / Conditions of Use herein.
TABLE 1: EVALUATED MEMBRANES
MATERIAL STANDARD
TYPE PRODUCT PLANT(S)
REFERENCE TYPE GRADE
Flintlastic® SA NailBase ASTM D4601 II N/A Little Rock, AR1
Pryor, OK
Glasbase™ Base Sheet ASTM D4601 II N/A
Little Rock, AR
All Weather/Empire™ Base Sheet ASTM D4601 II N/A Little Rock, AR1
Base Sheets
Flintlastic® Base 20 ASTM D4601 II N/A Little Rock, AR1
Flintlastic® Poly SMS Base Sheet ASTM D4601 II N/A Little Rock, AR1
(except glass mat is N/A)
Flintglas® MS Cap (inverted) ASTM D4897 II N/A Little Rock, AR
Pryor, OK1
Ply Sheets Flintglas® Ply 4 ASTM D2178 IV N/A
Shafter, CA
Flintlastic® APP Base T ASTM D6509 N/A N/A Little Rock, AR
Base/Ply
Flintlastic® STA ASTM D6222 I S Little Rock, AR
Membranes (APP)
Flintlastic® STA Plus ASTM D6222 I S Little Rock, AR
Flintlastic® STA ASTM D6222 I S Little Rock, AR
Flintlastic® STA Plus ASTM D6222 I S Little Rock, AR
Cap Membranes Flintlastic® GTA ASTM D6222 I G Little Rock, AR1
(APP) Flintlastic® GTA CoolStar® ASTM D6222 I G Little Rock, AR
Flintlastic® GTA-FR ASTM D6222 I G Little Rock, AR1
Flintlastic® GTA-FR CoolStar® ASTM D6222 I G Little Rock, AR

NEMO ETC, LLC Evaluation Report 3520.03.04-R30


Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) FL2533-R29
Flintlastic® Modified Bitumen Roof Systems Revision 30: 01/26/2023
Page 3 of 5
NEMO|etc.
TABLE 1 (CONTINUED): EVALUATED MEMBRANES
MATERIAL STANDARD
TYPE PRODUCT PLANT(S)
REFERENCE TYPE GRADE
Black Diamond® Base Sheet ASTM D1970 N/A N/A Shakopee, MN1
Flintlastic® SA PlyBase ASTM D1970 N/A N/A Little Rock, AR1
Flintlastic® SA Mid Ply ASTM D6163 I S Little Rock, AR1
Base/Ply
Flintlastic® Ultra Glass SA ASTM D6163 I S Little Rock, AR1
Membranes (SBS)
Flintlastic® Base 20 ASTM D6163 I S Little Rock, AR1
Flintlastic® Base 20 T ASTM D6163 I S Little Rock, AR1
Flintlastic® Ultra Poly SMS Base Sheet ASTM D6164 I S Little Rock, AR
Flintlastic® SA Cap FR ASTM D6163 I G Little Rock, AR1
Flintlastic® SA Cap FR CoolStar® ASTM D6163 I G Little Rock, AR
Flintlastic® SA Cap ASTM D6164 I G Little Rock, AR
Flintlastic® SA Cap CoolStar® ASTM D6164 I G Little Rock, AR
Cap Membranes
Flintlastic® FR-P ASTM D6164 I G Little Rock, AR
(SBS)
Flintlastic® FR-P CoolStar® ASTM D6164 I G Little Rock, AR
Flintlastic® GMS ASTM D6164 I G Little Rock, AR
Flintlastic® Premium FR-P ASTM D6164 II G Little Rock, AR
Flintlastic® Premium FR-P CoolStar® ASTM D6164 II G Little Rock, AR
1Indicates membrane/plant combination is Certified by ISO/IEC 17065 Certification Entity; NEMO|cert. to the noted standard. Refer to
www.nemocert.com for details.

5. LIMITATIONS:
5.1 This is a Building Code Evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer
of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting
or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (i.e., Broward and Miami-
Dade Counties).
5.3 This Evaluation Report pertains to above-deck roof components. Roof decks and structural members shall be in
accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1516 for requirements and
limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations
concerning the use of foam plastic insulation.
5.5 This Evaluation Report does not include evaluation of roof edge termination. Refer to FBC 1504.5 for requirements
and limitations regarding edge securement for low-slope roofs.
5.6 Refer to FBC 1511 for requirements and limitations regarding recover installations.
5.6.1 For mechanically attached components over existing roof decks, fasteners shall be tested in the existing deck for
withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum
requirements for the system. Testing shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard
TAS 105.
5.6.2 For bonded insulation or membrane over existing substrates in a re-roof (tear off) or recover installation, the
existing deck or existing roof surface shall be examined for compatibility with the adhesive to be installed. If any
surface conditions exist that bring system performance into question, field uplift testing in accordance with
ANSI/SPRI IA-1, ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124 shall
be conducted on mock-ups of the proposed new roof assembly.
5.6.3 For bonded insulation or membrane over existing substrates in a recover installation, the existing roof system shall
be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having
Jurisdiction, as documented through field uplift testing in accordance with ASTM E907, FM Loss Prevention Data
Sheet 1-52 or Testing Application Standard TAS 124.

NEMO ETC, LLC Evaluation Report 3520.03.04-R30


Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) FL2533-R29
Flintlastic® Modified Bitumen Roof Systems Revision 30: 01/26/2023
Page 4 of 5
NEMO|etc.
5.7 Refer to Appendix 1 for system attachment requirements for wind load resistance.
5.7.1 “MDP” = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads,
and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already
been applied). Refer to FBC 1609 for determination of design wind loads.
5.7.2 For mechanically attached components or partially-bonded insulation, the maximum design pressure for the
selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC Chapter
16. Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the
elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29,
Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an
asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 for Zone 2/3
enhancements.
5.7.3 For assemblies with all components fully bonded in place, the maximum design pressure for the selected assembly
shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16. No rational analysis
is permitted for these systems.
5.8 All components in the roof assembly shall have quality assurance audit in accordance with F.A.C. Rule 61G20-3.
Refer to the Product Approval of the component manufacturer for components listed in Appendix 1 that are
produced by a Product Manufacturer other than the report holder on Page 1 of this Evaluation Report.

6. INSTALLATION:
Flintlastic® Modified Bitumen Roof Systems shall be installed in accordance with CertainTeed, LLC published
installation instructions, subject to the Limitations of Use herein.

7. BUILDING PERMIT REQUIREMENTS:


As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this
product.

8. MANUFACTURING PLANTS:
Contact the named QA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 QA requirements. Refer
to Section 4 herein for products and production locations having met codified material standards.

9. QUALITY ASSURANCE ENTITY:


UL (QUA9625): (360) 817-5512; bsai.inspections@ul.com
- THE 74-PAGES THAT FOLLOW FORM PART OF THIS EVALUATION REPORT -

NEMO ETC, LLC Evaluation Report 3520.03.04-R30


Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) FL2533-R29
Flintlastic® Modified Bitumen Roof Systems Revision 30: 01/26/2023
Page 5 of 5
NEMO|etc.
APPENDIX 1: ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE
TABLE DECK APPLICATION TYPE DESCRIPTION PAGE
1A Wood New or Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 6
1B Wood New or Reroof (Tear-Off) A-2 Mechanically Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 7
1C Wood New, Reroof (Tear-Off) or Recover B-1 Mechanically Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 9
1D Wood New, Reroof (Tear-Off) or Recover C-1 Mechanically Attached Insulation, Bonded Roof Cover 10
1E Wood New, Reroof (Tear-Off) or Recover D-2 Insulated, Mechanically Attached Base Sheet, Bonded Roof Cover 12
1F Wood New, Reroof (Tear-Off) E-2 Non-Insulated, Mechanically Attached Base Sheet, Bonded Roof Cover 14
1G Wood New, Reroof (Tear-Off) or Recover E-2 Non-Insulated, Mechanically Attached Base Sheet, Bonded Roof Cover 17
1H Wood New or Reroof (Tear-Off) F Non-Insulated, Bonded Roof Cover 19
2A Steel or Structural concrete New, Reroof (Tear-Off) or Recover B-1 Mechanically Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 20
2B Steel or Structural concrete New, Reroof (Tear-Off) or Recover C-1 Mechanically Attached Insulation, Bonded Roof Cover 23
2C Steel or Structural concrete New, Reroof (Tear-Off) or Recover D-2 Insulated, Mechanically Attached Base Sheet, Bonded Roof Cover 27
3A Structural concrete New or Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 30
3B Structural concrete New or Reroof (Tear-Off) A-3 Bonded Temp Roof/Vapor Barrier, Bonded Insulation, Bonded Roof Cover 39
3C Structural concrete New or Reroof (Tear-Off) F Non-Insulated, Bonded Roof Cover 40
4A LWIC / steel New or Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 41
4B LWIC / structural concrete New or Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 43
4C LWIC / structural concrete New, Reroof (Tear-Off) A-1 Bonded Vapor Barrier, Bonded Insulation, Bonded Roof Cover 48
4D LWIC / steel New or Reroof (Tear-Off) A-2 Mechanically Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 50
4E LWIC / steel or struct. conc. New or Reroof (Tear-Off) E-2 Non-Insulated, Mechanically Attached Base Sheet, Bonded Roof Cover 53
4F LWIC / steel Reroof (Tear-Off) or Recover E-2 Non-Insulated, Mechanically Attached Base Sheet, Bonded Roof Cover 58
4G LWIC / steel Reroof (Tear-Off) F Non-Insulated, Bonded Roof Cover 58
5A Cementitious wood fiber New or Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 59
5B Cementitious wood fiber New or Reroof (Tear-Off) or Recover A-2 Mechanically Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 61
5C Cementitious wood fiber Reroof (Tear-Off) or Recover C-1 Mechanically Attached Insulation, Bonded Roof Cover 62
5D Cementitious wood fiber New, Reroof (Tear-Off) or Recover E-2 Non-Insulated, Mechanically Attached Base Sheet, Bonded Roof Cover 62
6A Existing gypsum Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 63
6B Existing gypsum Reroof (Tear-Off) A-2 Mechanically Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 65
6C Existing gypsum Reroof (Tear-Off) C-1 Mechanically Attached Insulation, Bonded Roof Cover 66
6D Existing gypsum Reroof (Tear-Off) E-2 Non-Insulated, Mechanically Attached Base Sheet, Bonded Roof Cover 66
7A Various Recover A-1 Bonded Insulation, Bonded Roof Cover 67
7B Various Recover F Non-Insulated, Bonded Roof Cover 74

NEMO ETC, LLC 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Evaluation Report 3520.03.04-R30 for FL2533-R29
Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 30: 01/26/2023
©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 1 of 74
NEMO|etc.
The following notes apply to the systems outlined herein:
1 The roof system evaluation herein pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having
Jurisdiction.
2 Unless otherwise noted, fasteners and stress plates shall be as follows. Fasteners shall be of sufficient length for the following engagements:
FASTENER/PLATE OPTIONS
DECK TYPE BY FBC FILE PARTS MINIMUM ENGAGEMENT
Altenloh, Brinck and Co. U.S., Inc. FL4500 Trufast #14 HD with Trufast 3” Metal Insulation Plates
Minimum ¾-inch plywood penetration or
Wood OMG, Inc. FL699 OMG #14 Roofgrip with AccuTrac Plates or OMG #14 Heavy Duty with OMG 3 in. Galvalume Steel Plate
minimum 1-inch wood plank embedment
SFS Group USA, Inc. FL20311 Dekfast DF-#14-PH3 with Dekfast PLT-H-2-7/8 or Dekfast PLT-R-3.
Altenloh, Brinck and Co. U.S., Inc. FL4500 Trufast #12 DP or Trufast #14 HD with Trufast 3” Metal Insulation Plates
OMG #12 or #14 Roofgrip with AccuTrac Plates or OMG #12 Standard or OMG #14 Heavy Duty with Minimum ¾-inch steel penetration and engage the
Steel OMG, Inc. FL699
OMG 3 in. Galvalume Steel Plate top flute of the steel deck
SFS Group USA, Inc. FL20311 Dekfast DF-#12-PH3 or DF-#14-PH3 with Dekfast PLT-H-2-7/8 or Dekfast PLT-R-3.
Altenloh, Brinck and Co. U.S., Inc. FL4500 Trufast #14 HD or Trufast Fluted Concrete Nail with Trufast 3” Metal Insulation Plates
Minimum 1-inch embedment. Fastener installed
Structural OMG #14 Roofgrip with AccuTrac Plates or OMG #14 Heavy Duty or CD-10 with OMG 3 in. Galvalume
OMG, Inc. FL699 with a pilot hole in accordance with the fastener
Concrete Steel Plate
manufacturer’s published installation instructions
SFS Group USA, Inc. FL20311 Dekfast DF-#14-PH3 with Dekfast PLT-H-2-7/8 or Dekfast PLT-R-3.

3 Unless otherwise noted, insulation may be any one layer or combination of FBC Approved (Local or Statewide) board(s) that meet FBC 1505 and, for foam plastic, FBC Chapter 26, when installed with the roof
cover.
4 Minimum 200 psi, minimum 2-inch FBC Approved lightweight insulating concrete may be substituted for, or installed below, rigid insulation board for System Types B-1, C-1, C-2, D-1 or D-2, whereby fasteners
are installed through the lightweight insulating concrete to engage the structural deck. The structural deck shall be of equal or greater type, thickness and strength to the steel and structural concrete deck
listings. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. This is a wind uplift resistance allowance and does not purport
to address non-wind-uplift-related issues, such as deck venting or moisture levels within the Lightweight Concrete and the potential effect on overlying components.
5 Preliminary insulation attachment for System Type D: Unless otherwise noted, use FBC Approved fasteners and plates and refer to Section 2.2.10.1.3 of FM Loss Prevention Data Sheet 1-29.
6 Unless otherwise noted, insulation adhesive application rates are as follows.
Ribbon or bead width is at the time of application; the ribbons/beads shall expand as noted in the manufacturer’s published instructions.
When multiple layers(s) of insulation and/or coverboard are installed in ribbon-applied adhesive, board joints shall be staggered.
The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing.
INSULATION ADHESIVE REFERENCES
BY FBC ADHESIVE REFERENCE MINIMUM RATE NOTE
DuPont de Nemours, Inc. FL720 Insta Stik Quik Set Insta Stick Continuous 0.75 to 1 inch wide ribbons, 12-inch o.c
Millennium One Step Foamable Adhesive M-OSFA Continuous 0.25 to 0.5-inch wide ribbons, 12-inch o.c.
H.B. Fuller Company FL1800 Millennium PG-1 Pump Grade Adhesive M-PG1 Continuous 0.5 to 0.75-inch wide ribbons, 12-inch o.c.
Millennium PG-1 EF ECO M-PG1-EF-ECO Continuous 1 to 1.5-inch wide ribbons, 12-inch o.c.
FL22256 Polyset Board-Max Polyset BM Continuous 3-inch wide ribbons, 12-inch o.c.
ICP Construction, Inc.
FL1365 Polyset Commercial Roofing Adhesive Polyset CRA Continuous 2.5 to 3-inch wide ribbons, 12-inch o.c. Formerly Polyset CR-20
OMG, Inc. FL1608 OlyBond 500 Adhesive Fastener OB500 Continuous 0.75-inch wide ribbons, 12-inch o.c. PaceCart, SpotShot or Canister dispensing
Generic, ASTM D312, Type If applying hot asphalt to concrete deck, deck shall
N/A hot asphalt N/A Full coverage at 25-30 lbs/square
IV be primed with ASTM D41 primer

NEMO ETC, LLC 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Evaluation Report 3520.03.04-R30 for FL2533-R29
Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 30: 01/26/2023
©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 2 of 74
NEMO|etc.
7 Unless otherwise noted, all insulations are flat-stock or taper board of the minimum thickness noted. Tapered polyisocyanurate at the following thickness limitations may be substituted with the following
Maximum Design Pressure (MDP) limitations. In no case shall these values be used to ‘increase’ the MDP listings in the tables; rather if MDP listing below meets or exceeds that listed for a particular system in
the tables, then the thinner board listed below may be used as a drop-in for the equivalent thicker material listed in the table.
MDP LIMITATIONS FOR TAPERED POLYISOCYANURATE INSULATIONS
INSULATION MIN. TAPERED
ADHESIVE MDP (PSF)
LISTED PRODUCT FBC THICKNESS (IN)
Insta Stik Any polyisocyanurate listed with adhesive herein Various 1.0 -120.0
M-OSFA Any polyisocyanurate listed with adhesive herein Various 1.0 -157.5
M-PG1 Any polyisocyanurate listed with adhesive herein Various 1.0 -157.5
Polyset CRA Any polyisocyanurate listed with adhesive herein Various 1.0 -117.5
OB500 Rmax Multi-Max FA3 FL11207 0.5 -45.0
OB500 Hunter H-Shield FL5968 0.5 -315.0
OB500 Johns Manville ENRGY 3 FL4205 0.5 -315.0
OB500 Atlas Roofing ACFoam II FL17989 0.5 -487.5

8 For adhered roof insulation and board-size: Unless otherwise noted, refer to Section 2.2.10.6.2 of FM Loss Prevention Data Sheet 1-29.
9 For mechanically attached components or partially-bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1 PRIME design pressure determined in
accordance with FBC Chapter 16. Elevated pressure zones shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are
ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk* carry the limitations set forth in
Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 for Zone 2/3 enhancements.
10 For assemblies with all components fully bonded, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16. No
rational analysis is permitted for these systems.
11 For mechanically attached components over existing decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the
minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105.
12 For bonded insulation or membrane over existing substrates in a re-roof (tear off) or recover installation, the existing deck or existing roof surface shall be examined for compatibility with the adhesive to be
installed. If any surface conditions exist that bring system performance into question, field uplift testing shall be conducted on mock-ups of the proposed new roof assembly. For bonded insulation or membrane
over existing substrates in a recover installation, the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as
documented through field uplift testing. Field uplift testing shall be in accordance with ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124.
13 Refer to FBC 1511 for requirements and limitations regarding recover installations. For Structural Concrete Deck or Recover Applications using System Type C-1 the base insulation layer is optional and for System
Type C-2, D-1 or D-2, the insulation is optional. Alternatively, an FBC Approved insulation board or coverboard may be used as a separation layer. Board products shall be preliminarily attached prior to roof
cover installation (Note 5 herein). The separator component shall be documented as meeting FBC 1505 and, for foam plastic, FBC Chapter 26, when installed with the roof cover in Recover applications.
14 Lightweight insulating concrete (LWIC) shall be cast in accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWIC is referenced, refer to current
LWIC Product Approval for specific deck construction and limitations. Unless otherwise noted, for systems where specific LWIC is not referenced, the minimum design mix shall be 300 psi. In all cases, the
minimum top-coat thickness is 2-inches. For LWIC over structural concrete, reference is made to FBC Section 1917.4.1, Point 1. For “pre-existent” LWIC references, listings were established through testing over
lightweight concrete cast using only foaming agent (ASTM C896), water and Portland cement (ASTM C150), with no proprietary additives, in accordance with procedures adopted by Miami-Dade BCCO (FBC
CER1592). Use of these listings in new construction or re-roof (tear-off) applications is at the discretion of the Designer or Record and Authority Having Jurisdiction.

NEMO ETC, LLC 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Evaluation Report 3520.03.04-R30 for FL2533-R29
Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 30: 01/26/2023
©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 3 of 74
NEMO|etc.
15 For bonded membrane applications, unless otherwise noted, refer to the following.
MEMBRANE / ADHESIVE COMBINATIONS
REFERENCE LAYER MATERIAL APPLICATION
Base Ply: Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base
Note: Base ply cures overnight prior to application of the ply or cap ply. Karnak No. 81 Cold Process Modified Bitumen Adhesive Brush Grade
SBS-CA1
Ply: Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base at 1 gal/square
Cap Ply: Flintlastic FR-P, Flintlastic FR-P CoolStar, Flintlastic Premium FR-P, Flintlastic Premium FR-P CoolStar, Flintlastic GMS
BP-CA2 Base Ply: Glasbase Base Sheet, All Weather/Empire Base Sheet, Flintlastic Base 20
Base Ply: Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base
Henry #903 Adhesive at 1.5 gal/square.
SBS-CA2 Ply: Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base
Cap Ply: Flintlastic FR-P, Flintlastic FR-P CoolStar, Flintlastic Premium FR-P, Flintlastic Premium FR-P CoolStar, Flintlastic GMS
BP-CA3 Base Ply: Glasbase Base Sheet, All Weather/Empire Base Sheet, Flintlastic Base 20
Base Ply: Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base HB Fuller “Millennium Hurricane Force Membrane Adhesive”, beads
SBS-CA3 Ply: Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base spaced 6-inch o.c.
Cap Ply: Flintlastic FR-P, Flintlastic FR-P CoolStar, Flintlastic Premium FR-P, Flintlastic Premium FR-P CoolStar, Flintlastic GMS
Base Ply: Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base
Note: Base ply cures overnight prior to application of the ply or cap ply. FlintBond Brush or Tropical Roofing Products #216 Modified
SBS-CA4
Ply: Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Bitumen Adhesive at 1 to 1.5 gal/square.
Cap Ply: Flintlastic FR-P, Flintlastic FR-P CoolStar, Flintlastic Premium FR-P, Flintlastic Premium FR-P CoolStar, Flintlastic GMS
Base Ply: Glasbase Base Sheet, All Weather/Empire Base Sheet, Flintlastic Base 20
BP-AA hot asphalt at 20-40 lbs/square
Ply: One or more Flintglas Ply 4
BP-AA2 Base Ply: Flintglas MS Cap (inverted) hot asphalt in 24-inch diameter spots in 30-inch grid pattern
BP-AA3 Base Ply: Flintglas MS Cap (inverted) hot asphalt in 9-inch diameter spots in grid pattern noted herein.
BP-AA4 Base Ply: Flintglas MS Cap (inverted) hot asphalt in 9-inch wide ribbons spaced as noted herein.
Base Ply: Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base
SBS-AA Ply: One or more Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base hot asphalt at 20-40 lbs/square
Cap Ply: Flintlastic FR-P, Flintlastic FR-P CoolStar, Flintlastic Premium FR-P, Flintlastic Premium FR-P CoolStar, Flintlastic GMS
Base Ply: Flintlastic Ultra Poly SMS Base Sheet, Flintlastic Base 20 T
SBS-TA torch-applied
Ply: One or more Flintlastic Ultra Poly SMS Base Sheet, Flintlastic Base 20 T
Base Ply: One or more Flintlastic APP Base T, Flintlastic STA, Flintlastic STA Plus
APP-TA Flintlastic STA, Flintlastic STA Plus, Flintlastic GTA, Flintlastic GTA CoolStar, Flintlastic GTA-FR, Flintlastic GTA-FR torch-applied
Cap Ply:
CoolStar
SBS-SA-H Base Ply: Black Diamond Base Sheet, Flintlastic Ultra Glass SA self-adhering (activated by overlying membrane)
Base Ply: Flintlastic SA PlyBase, Flintlastic SA Mid Ply
SBS-SA Ply: Flintlastic SA PlyBase, Flintlastic SA Mid Ply self-adhering
Cap Ply: Flintlastic SA Cap, Flintlastic SA Cap CoolStar, Flintlastic SA Cap FR, Flintlastic SA Cap FR CoolStar

NEMO ETC, LLC 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Evaluation Report 3520.03.04-R30 for FL2533-R29
Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 30: 01/26/2023
©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 4 of 74
NEMO|etc.
16 Vapor barrier options for use over structural concrete deck followed by bonded insulation carry the following MDP limitations. The lesser of the MDP listings below vs. that for the selected assembly applies.
VAPOR BARRIER OPTIONS, STRUCTURAL CONCRETE DECK, ADHERED INSULATION
VAPOR BARRIER INSULATION ADHESIVE
OPTION # PRIMER MDP (PSF)
TYPE ATTACH PER TABLE 3A
C-VB-1. FlintPrime QD Flintlastic SA PlyBase Self-adhering OB500, 12-inch o.c. -82.5
All Weather/Empire Base Sheet, 3-inch wide side laps and 6-inch wide end laps are HB Fuller “Millennium Hurricane Force
C-VB-2. None M-OSFA or M-PG1, 12-inch o.c. -82.5
sealed with HB Fuller “HB Fuller “Millennium Hurricane Force Lap and Flashing Adhesive” Membrane Adhesive HS”, max. 6-inch o.c.
Flintlastic Ultra Poly SMS Base Sheet, 3-inch wide side laps and 6-inch wide end laps are
HB Fuller “Millennium Hurricane Force
C-VB-3. None hot-air-welded, torch-welded or sealed with HB Fuller “HB Fuller “Millennium Hurricane M-OSFA or M-PG1, 12-inch o.c. -82.5
Membrane Adhesive HS”, max. 6-inch o.c.
Force Lap and Flashing Adhesive”
C-VB-4. FlintPrime QD Black Diamond Base Sheet, Flintlastic Ultra Glass SA or Flintlastic SA Cap Self-adhering M-OSFA or M-PG1, 12-inch o.c. -97.5
C-VB-5. FlintPrime QD Black Diamond Base Sheet, Flintlastic Ultra Glass SA or Flintlastic SA Cap Self-adhering M-OSFA or M-PG1, 6-inch o.c. -315.0
C-VB-6. FlintPrime QD Flintlastic GTA Torch-applied M-OSFA or M-PG1, 12-inch o.c. -420.0
C-VB-7. FlintPrime QD Flintlastic Base 20 T Torch-applied M-OSFA or M-PG1, 12-inch o.c. -495.0

17 The following products are interchangeable within the scope of this Evaluation Report.
ACCEPTABLE ALTERNATES
SUB-CATEGORY MANUFACTURER FBC LISTED PRODUCT HEREIN ALTERNATE
M-OSFA FlintFast QS Insulation Adhesive
Adhesives H.B. Fuller Company FL1800
M-PG1 FlintFast LV Insulation Adhesive
Trufast #12 DP FlintFast #12 Fastener
Trufast #14 HD FlintFast #14 Fastener
Roofing Altenloh, Brinck and Co. U.S., Trufast #15 EHD FlintFast #15 EHD Fastener
FL4500
Fasteners Inc. Trufast 2” Barbed Metal Seam Plate FlintFast 2” Barbed Seam Plate
Trufast 2.4” Barbed Metal Seam Plate FlintFast 2.4” Barbed Seam Plate
Trufast 3” Metal Insulation Plate FlintFast 3” Insulation Plate
ACFoam II FlintBoard ISO
Atlas Roofing FL17989
ACFoam III FlintBoard ISO Cold
Roofing
H-Shield FlintBoardH ISO
Insulation Hunter Panels FL5968
H-Shield CG FlintBoardH ISO Cold
Georgia-Pacific Gypsum, LLC FL1250 DensDeck Prime DensDeck StormX Prime Roof Board

18 “MDP” = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609 for determination of design wind loads.

NEMO ETC, LLC 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Evaluation Report 3520.03.04-R30 for FL2533-R29
Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 30: 01/26/2023
©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 5 of 74
NEMO|etc.
TABLE 1A: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
Base Insulation Top Insulation Roof Cover (Note 15)
Sys. Deck MDP
Attach Attach Primer
No. (Note 1) Type Type Base Ply Ply Cap Ply (psf)
(Notes 6,7,8) (Notes 6,7,8)
SELF-ADHERING SYSTEMS:
Min. 1.5-inch (Optional) Additional layer(s) of base insulation
Min. 15/32-inch APA rated M-OSFA or M-OSFA or (Optional) SBS-
W-1 ACFoam II or and/or min. 0.25-inch DensDeck Prime or FlintPrime QD SBS-SA SBS-SA -60.0
CDX plywood, 24-inch span M-PG1 M-PG1 SA
H-Shield SECUROCK Gypsum-Fiber Roof Board.
Min. 1.5-inch (Optional) Additional layer(s) of base insulation
Min. 15/32-inch APA rated (Optional) SBS-
W-2 ACFoam II or OB500 and/or min. 0.25-inch SECUROCK Gypsum-Fiber OB500 FlintPrime QD SBS-SA SBS-SA -60.0
CDX plywood, 24-inch span SA
H-Shield Roof Board.
Min. 15/32-inch APA rated Min. 1.5-inch M-OSFA or (Optional) Additional layer(s) of base insulation M-OSFA or
(Optional) SBS-
W-3 CDX plywood, 24-inch span, ACFoam II or M-PG1, 6- and/or min. 0.25-inch DensDeck Prime or M-PG1, 6- FlintPrime QD SBS-SA SBS-SA -97.5
SA
blocked 48-inch o.c. H-Shield inch o.c. SECUROCK Gypsum-Fiber Roof Board. inch o.c.
Min. 15/32-inch APA rated Min. 1.5-inch (Optional) Additional layer(s) of base insulation
OB500, 6- OB500, 6- (Optional) SBS-
W-4 CDX plywood, 24-inch span, ACFoam II or and/or min. 0.25-inch SECUROCK Gypsum-Fiber FlintPrime QD SBS-SA SBS-SA -97.5
inch o.c. inch o.c. SA
blocked 48-inch o.c. H-Shield Roof Board.
HYBRID SYSTEMS:
Min. 1.5-inch (Optional) Additional layer(s) of base insulation (Optional) BP-
Min. 15/32-inch APA rated M-OSFA or M-OSFA or SBS-AA or
W-5 ACFoam II or and/or min. 0.25-inch DensDeck Prime or None SBS-SA-H AA, SBS-AA, SBS- -60.0
CDX plywood, 24-inch span M-PG1 M-PG1 APP-TA
H-Shield SECUROCK Gypsum-Fiber Roof Board. TA or APP-TA
Min. 1.5-inch (Optional) Additional layer(s) of base insulation (Optional) BP-
Min. 15/32-inch APA rated SBS-AA or
W-6 ACFoam II or OB500 and/or min. 0.25-inch SECUROCK Gypsum-Fiber OB500 None SBS-SA-H AA, SBS-AA, SBS- -60.0
CDX plywood, 24-inch span APP-TA
H-Shield Roof Board. TA or APP-TA
Min. 15/32-inch APA rated Min. 1.5-inch M-OSFA or (Optional) Additional layer(s) of base insulation M-OSFA or (Optional) BP-
SBS-AA or
W-7 CDX plywood, 24-inch span, ACFoam II or M-PG1, 6- and/or min. 0.25-inch DensDeck Prime or M-PG1, 6- None SBS-SA-H AA, SBS-AA, SBS- -97.5
APP-TA
blocked 48-inch o.c. H-Shield inch o.c. SECUROCK Gypsum-Fiber Roof Board. inch o.c. TA or APP-TA
Min. 15/32-inch APA rated Min. 1.5-inch (Optional) Additional layer(s) of base insulation (Optional) BP-
OB500, 6- OB500, 6- SBS-AA or
W-8 CDX plywood, 24-inch span, ACFoam II or and/or min. 0.25-inch SECUROCK Gypsum-Fiber None SBS-SA-H AA, SBS-AA, SBS- -97.5
inch o.c. inch o.c. APP-TA
blocked 48-inch o.c. H-Shield Roof Board. TA or APP-TA
CONVENTIONAL SYSTEMS:
Min. 1.5-inch Optional additional layers of base insulation, BP-AA, SBS- (Optional) BP-
Min. 15/32-inch APA rated M-OSFA or M-OSFA or SBS-AA or
W-9 ACFoam II or followed by min. 0.25-inch DensDeck Prime or None AA, SBS-TA AA, SBS-AA, SBS- -60.0
CDX plywood, 24-inch span M-PG1 M-PG1 APP-TA
H-Shield SECUROCK Gypsum-Fiber Roof Board or APP-TA TA or APP-TA
Min. 1.5-inch (Optional) Additional layer(s) of base insulation BP-AA, SBS- (Optional) BP-
Min. 15/32-inch APA rated SBS-AA or
W-10 ACFoam II or OB500 and/or min. 0.25-inch SECUROCK Gypsum-Fiber OB500 None AA, SBS-TA AA, SBS-AA, SBS- -60.0
CDX plywood, 24-inch span APP-TA
H-Shield Roof Board. or APP-TA TA or APP-TA
Min. 15/32-inch APA rated Min. 1.5-inch M-OSFA or Optional additional layers of base insulation, M-OSFA or BP-AA, SBS- (Optional) BP-
SBS-AA or
W-11 CDX plywood, 24-inch span, ACFoam II or M-PG1, 6- followed by min. 0.25-inch DensDeck Prime or M-PG1, 6- None AA, SBS-TA AA, SBS-AA, SBS- -97.5
APP-TA
blocked 48-inch o.c. H-Shield inch o.c. SECUROCK Gypsum-Fiber Roof Board. inch o.c. or APP-TA TA or APP-TA

NEMO ETC, LLC 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Evaluation Report 3520.03.04-R30 for FL2533-R29
Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 30: 01/26/2023
©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 6 of 74
NEMO|etc.
TABLE 1A: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
Base Insulation Top Insulation Roof Cover (Note 15)
Sys. Deck MDP
Attach Attach Primer
No. (Note 1) Type Type Base Ply Ply Cap Ply (psf)
(Notes 6,7,8) (Notes 6,7,8)
Min. 15/32-inch APA rated Min. 1.5-inch (Optional) Additional layer(s) of base insulation BP-AA, SBS- (Optional) BP-
OB500, 6- OB500, 6- SBS-AA or
W-12 CDX plywood, 24-inch span, ACFoam II or and/or min. 0.25-inch SECUROCK Gypsum-Fiber None AA, SBS-TA AA, SBS-AA, SBS- -97.5
inch o.c. inch o.c. APP-TA
blocked 48-inch o.c. H-Shield Roof Board. or APP-TA TA or APP-TA

TABLE 1B: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)


SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER
Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15)
Sys. Deck MDP
Fasten Attach Attach Primer
No. (Note 1) Type Attach Type Type Base Ply Ply Cap Ply (psf)
(Note 11) (Notes 6,7,8) (Notes 6,7,8)
SELF-ADHERING SYSTEMS:
Glasbase Base Sheet,
32 ga., 1-5/8- 9-inch o.c. in 4-
Min. 19/32- All Weather/Empire Min. 1.5-inch
inch dia. tin inch lap and 12-
inch Base Sheet, ACFoam II, Min. 0.25-
caps with 11 inch o.c. in two FlintPrime (Optional)
W-13 plywood, Flintlastic Base 20, ENRGY 3, H- hot asphalt inch hot asphalt SBS-SA SBS-SA -45.0*
ga. annular (2), equally QD SBS-SA
24-inch Poly SMS, Ultra Poly Shield or Multi- DensDeck
ring shank spaced, staggered
span SMS or Flintglas MS Max FA3
nails center rows
Cap (inverted)
32 ga., 1-5/8- 8-inch o.c. in 3- hot asphalt full hot asphalt full
Min. 19/32- Min. 1.5-inch
Glasbase Base Sheet, inch dia. tin inch lap and 8- coverage or M- coverage or M-
inch ACFoam II, Min. 0.25-
All Weather/Empire caps with 11 inch o.c. in three OSFA, Insta Stik, OSFA, Insta Stik, FlintPrime (Optional)
W-14 plywood, ENRGY 3, H- inch SBS-SA SBS-SA -52.5
Base Sheet, Poly SMS ga. annular (3), equally OB500, Polyset OB500, Polyset QD SBS-SA
24-inch Shield or Multi- DensDeck
or Ultra Poly SMS ring shank spaced, staggered BM or Polyset BM or Polyset
span Max FA3
nails center rows CRA, 4-inch o.c. CRA, 6-inch o.c.
32 ga., 1-5/8- 8-inch o.c. in 3-
Min. 19/32- Min. 1.5-inch
inch dia. tin inch lap and 8-
inch ACFoam II, Min. 0.25-
Flintglas MS Cap caps with 11 inch o.c. in three FlintPrime (Optional)
W-15 plywood, ENRGY 3, H- hot asphalt inch hot asphalt SBS-SA SBS-SA -52.5
(inverted) ga. annular (3), equally QD SBS-SA
24-inch Shield or Multi- DensDeck
ring shank spaced, staggered
span Max FA3
nails center rows
32 ga., 1-5/8- 8-inch o.c. in 3- (Optional) Min. hot asphalt full Min. 0.25- hot asphalt full
Min. 19/32-
Glasbase Base Sheet, inch dia. tin inch lap and 8- 1.5-inch coverage or M- inch coverage or M-
inch
All Weather/Empire caps with 11 inch o.c. in three ACFoam II, OSFA, Insta Stik, SECUROCK OSFA, Insta Stik, FlintPrime (Optional)
W-16 plywood, SBS-SA SBS-SA -60.0
Base Sheet, Poly SMS ga. annular (3), equally ENRGY 3, H- OB500, Polyset Gypsum- OB500, Polyset QD SBS-SA
24-inch
or Ultra Poly SMS ring shank spaced, staggered Shield or Multi- BM or Polyset Fiber Roof BM or Polyset
span
nails center rows Max FA3 CRA, 4-inch o.c. Board CRA, 6-inch o.c.

NEMO ETC, LLC 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Evaluation Report 3520.03.04-R30 for FL2533-R29
Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 30: 01/26/2023
©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 7 of 74
NEMO|etc.
TABLE 1B: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER
Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15)
Sys. Deck MDP
Fasten Attach Attach Primer
No. (Note 1) Type Attach Type Type Base Ply Ply Cap Ply (psf)
(Note 11) (Notes 6,7,8) (Notes 6,7,8)
32 ga., 1-5/8- 8-inch o.c. in 3- (Optional) Min. Min. 0.25-
Min. 19/32-
inch dia. tin inch lap and 8- 1.5-inch inch
inch
Flintglas MS Cap caps with 11 inch o.c. in three ACFoam II, SECUROCK FlintPrime (Optional)
W-17 plywood, hot asphalt hot asphalt SBS-SA SBS-SA -60.0
(inverted) ga. annular (3), equally ENRGY 3, H- Gypsum- QD SBS-SA
24-inch
ring shank spaced, staggered Shield or Multi- Fiber Roof
span
nails center rows Max FA3 Board
HYBRID SYSTEMS:
Glasbase Base Sheet,
32 ga., 1-5/8- 9-inch o.c. in 4-
Min. 19/32- All Weather/Empire Min. 1.5-inch
inch dia. tin inch lap and 12- (Optional)
inch Base Sheet, ACFoam II, SBS-AA
caps with 11 inch o.c. in two BP-AA, SBS-
W-18 plywood, Flintlastic Base 20, ENRGY 3, H- hot asphalt None N/A None SBS-SA-H or APP- -45.0*
ga. annular (2), equally AA, SBS-TA
24-inch Poly SMS, Ultra Poly Shield or Multi- TA
ring shank spaced, staggered or APP-TA
span SMS or Flintglas MS Max FA3
nails center rows
Cap (inverted)
32 ga., 1-5/8- 8-inch o.c. in 3-
Min. 19/32- Min. 1.5-inch
inch dia. tin inch lap and 8- (Optional)
inch Glasbase Base Sheet ACFoam II, SBS-AA
caps with 11 inch o.c. in three BP-AA, SBS-
W-19 plywood at or Flintglas MS Cap ENRGY 3, H- hot asphalt None N/A None SBS-SA-H or APP- -60.0
ga. annular (3), equally AA, SBS-TA
max. 24- (inverted) Shield or Multi- TA
ring shank spaced, staggered or APP-TA
inch Max FA3
nails center rows
CONVENTIONAL SYSTEMS:
Glasbase Base Sheet,
32 ga., 1-5/8- 9-inch o.c. in 4-
Min. 19/32- All Weather/Empire Min. 1.5-inch
inch dia. tin inch lap and 12- BP-AA, (Optional)
inch Base Sheet, ACFoam II, Min. 0.25- SBS-AA
caps with 11 inch o.c. in two FlintPrime SBS-AA, BP-AA, SBS-
W-20 plywood, Flintlastic Base 20, ENRGY 3, H- hot asphalt inch hot asphalt or APP- -45.0*
ga. annular (2), equally QD SBS-TA or AA, SBS-TA
24-inch Poly SMS, Ultra Poly Shield or Multi- DensDeck TA
ring shank spaced, staggered APP-TA or APP-TA
span SMS or Flintglas MS Max FA3
nails center rows
Cap (inverted)
32 ga., 1-5/8- 8-inch o.c. in 3- hot asphalt full hot asphalt full
Min. 19/32- Min. 1.5-inch
Glasbase Base Sheet, inch dia. tin inch lap and 8- coverage or M- coverage or M- BP-AA, (Optional)
inch ACFoam II, Min. 0.25- SBS-AA
All Weather/Empire caps with 11 inch o.c. in three OSFA, Insta Stik, OSFA, Insta Stik, FlintPrime SBS-AA, BP-AA, SBS-
W-21 plywood, ENRGY 3, H- inch or APP- -52.5
Base Sheet, Poly SMS ga. annular (3), equally OB500, Polyset OB500, Polyset QD SBS-TA or AA, SBS-TA
24-inch Shield or Multi- DensDeck TA
or Ultra Poly SMS ring shank spaced, staggered BM or Polyset BM or Polyset APP-TA or APP-TA
span Max FA3
nails center rows CRA, 4-inch o.c. CRA, 6-inch o.c.
32 ga., 1-5/8- 8-inch o.c. in 3- (Optional) Min. hot asphalt full Min. 0.25- hot asphalt full
Min. 19/32-
Glasbase Base Sheet, inch dia. tin inch lap and 8- 1.5-inch coverage or M- inch coverage or M- BP-AA, (Optional)
inch SBS-AA
All Weather/Empire caps with 11 inch o.c. in three ACFoam II, OSFA, Insta Stik, SECUROCK OSFA, Insta Stik, SBS-AA, BP-AA, SBS-
W-22 plywood, None or APP- -60.0
Base Sheet, Poly SMS ga. annular (3), equally ENRGY 3, H- OB500, Polyset Gypsum- OB500, Polyset SBS-TA or AA, SBS-TA
24-inch TA
or Ultra Poly SMS ring shank spaced, staggered Shield or Multi- BM or Polyset Fiber Roof BM or Polyset APP-TA or APP-TA
span
nails center rows Max FA3 CRA, 4-inch o.c. Board CRA, 6-inch o.c.

NEMO ETC, LLC 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Evaluation Report 3520.03.04-R30 for FL2533-R29
Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 30: 01/26/2023
©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 8 of 74
NEMO|etc.
TABLE 1C: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER
Base Insulation Layer Top Insulation Layer Roof Cover (Note 15)
System Deck MDP
No. (Note 1)
Attach (psf)
Type Fasten (Note 11) Attach Type Base Ply Ply Cap Ply
(Notes 6,7,8)
SELF-ADHERING SYSTEMS:
Min. 15/32-inch Min. 2-inch
1 per
W-23 plywood, 24- ACFoam II or H- Note 2 Min. 2-inch H-Shield HD Composite M-OSFA or M-PG1 SBS-SA (Optional) SBS-SA SBS-SA -30.0
2.7 ft2
inch span Shield
HYBRID SYSTEMS:
Min. 15/32-inch Min. 2-inch (Optional) BP-AA,
1 per SBS-AA or
W-24 plywood, 24- ACFoam II or H- Note 2 Min. 2-inch H-Shield HD Composite M-OSFA or M-PG1 SBS-SA-H SBS-AA, SBS-TA or -30.0
2.7 ft2 APP-TA
inch span Shield APP-TA
Min. 15/32-inch Min. 1.5-inch Trufast #12 DP or #14 HD hot asphalt, M-OSFA,
1 per
W-25 plywood, 24- ACFoam II or H- with Trufast 3”Metal Min. 1.5-inch ACFoam II or H-Shield M-PG1 Insta Stik, SBS-SA-H (Optional) APP-TA APP-TA -67.5
1.3 ft2
inch span Shield Insulation Plates OB500
CONVENTIONAL SYSTEMS:
Min. 0.5-inch Structodek High
Min. 23/32-inch Min. 1.5-inch (Optional) BP-AA,
1 per Density Fiberboard Roof Insulation, BP-AA or SBS-AA or
W-26 plywood, 24- ACFoam II, ENRGY Note 2 hot asphalt SBS-AA, SBS-TA or -45.0*
2.0 ft2 min. 0.75-inch FescoBoard SBS-AA APP-TA
inch span 3 or H-Shield APP-TA
(homogeneous)
Min. 23/32-inch Min. 1.5-inch Min. 0.25-inch DensDeck, DensDeck BP-AA, SBS- (Optional) BP-AA,
1 per SBS-AA or
W-27 plywood, 24- ACFoam II, ENRGY Note 2 Prime or SECUROCK Gypsum-Fiber hot asphalt AA, SBS-TA SBS-AA, SBS-TA or -45.0*
2.0 ft2 APP-TA
inch span 3 or H-Shield Roof Board or APP-TA APP-TA
Optional additional layer(s) of base
Min. 15/32-inch Min. 1.5-inch Trufast #12 DP or #14 HD hot asphalt, M-OSFA,
1 per insulation followed by Min. 0.25-
W-28 plywood, 24- ACFoam II or H- with Trufast 3”Metal M-PG1, Insta Stik, APP-TA (Optional) APP-TA APP-TA -90.0
1.3 ft2 inch SECUROCK Gypsum-Fiber Roof
inch span Shield Insulation Plates OB500
board
COLD-APPLIED SYSTEMS:
Min. 15/32-inch Min. 2-inch
1 per
W-29 plywood, 24- ACFoam II or H- Note 2 Min. 2-inch H-Shield HD Composite M-OSFA or M-PG1 SBS-CA4 None SBS-CA4 -30.0
2.7 ft2
inch span Shield

NEMO ETC, LLC 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Evaluation Report 3520.03.04-R30 for FL2533-R29
Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 30: 01/26/2023
©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 9 of 74
NEMO|etc.
TABLE 1D: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER
System Deck Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP
Primer
No. (Note 1) (Note 3, Note 13) Type Fasten (Note 11) Attach Base Ply Ply Cap Ply (psf)
SELF-ADHERING SYSTEMS:
Min. 15/32-inch (Optional) One or more Trufast #12 DP or #14 HD
Min. 0.25-inch SECUROCK 1 per (Optional) SBS-
W-30 plywood, 24-inch layers, any combination, with Trufast 3” Metal None SBS-SA SBS-SA -30.0*
Gypsum-Fiber Roof Board 3.2 ft2 SA
span loose laid Insulation Plate
Min. 19/32-inch (Optional) One or more
1 per FlintPrime (Optional) SBS-
W-31 plywood, 24-inch layers, any combination, Min. 0.25-inch DensDeck Note 2 SBS-SA SBS-SA -45.0
1.3 ft2 QD SA
span loose laid
Min. 19/32-inch (Optional) One or more Trufast #12 DP or #14 HD
Min. 3/8-inch SECUROCK 1 per (Optional) SBS-
W-32 plywood, 24-inch layers, any combination, with Trufast 3” Metal None SBS-SA SBS-SA -45.0*
Gypsum-Fiber Roof Board 2.7 ft2 SA
span loose laid Insulation Plate
Min. 19/32-inch (Optional) One or more Min. 1.5-inch ACFoam II, Trufast #12 DP or #14 HD
1 per FlintPrime (Optional) SBS-
W-33 plywood, 24-inch layers, any combination, ENRGY 3, H-Shield or Multi- with Trufast 3” Metal SBS-SA SBS-SA -45.0*
2.0 ft2 QD SA
span loose laid Max FA3 Insulation Plate
Min. 15/32-inch (Optional) One or more
Trufast #14 HD with Trufast 1 per FlintPrime (Optional) SBS-
W-34 plywood, 24-inch layers, any combination, Min. 1.5-inch ACFoam II SBS-SA SBS-SA -52.5
3” Metal Insulation Plate 1.6 ft2 QD SA
span loose laid

Min. 19/32-inch (Optional) One or more Min. 1.5-inch ACFoam II,


1 per FlintPrime (Optional) SBS-
W-35 plywood, 24-inch layers, any combination, ENRGY 3, H-Shield or Multi- Note 2 SBS-SA SBS-SA -60.0
1.45 ft2 QD SA
span loose laid Max FA3

HYBRID SYSTEMS:
(Optional) BP-
Min. 15/32-inch (Optional) One or more Trufast #12 DP or #14 HD
Min. 0.25-inch DensDeck, 1 per SBS-SA- AA, SBS-AA, SBS-AA or
W-36 plywood, 24-inch layers, any combination, with Trufast 3” Metal None -30.0*
DensDeck Prime 2.0 ft2 H SBS-TA or APP- APP-TA
span loose laid Insulation Plate
TA
Min. 15/32-inch (Optional) One or more
Trufast #14 HD with Trufast 1 per SBS-SA- (Optional) SBS-
W-37 plywood, 24-inch layers, any combination, Min. 1.5-inch ACFoam II None APP-TA -52.5
3” Metal Insulation Plate 1.6 ft2 H TA or APP-TA
span loose laid
Min. 15/32-inch (Optional) One or more
Min. 1.5-inch ACFoam II, 1 per SBS-SA- (Optional) BP-
W-38 plywood, 24-inch layers, any combination, Note 2 None SBS-AA -52.5
ENRGY 3 or Multi-Max FA3 1.3 ft2 H AA or SBS-AA
span loose laid
(Optional) BP-
Min. 19/32-inch (Optional) One or more
Min. 1.5-inch ACFoam II or H- 1 per SBS-SA- AA, SBS-AA, SBS-AA or
W-39 plywood, 24-inch layers, any combination, Note 2 None -60.0
Shield 1.45 ft2 H SBS-TA or APP- APP-TA
span loose laid
TA
Min. 15/32-inch (Optional) Min. 1.5-inch, One Trufast #12 DP or #14 HD (Optional) SBS-
Min. 1.5-inch ACFoam II or H- 1 per SBS-SA- SBS-AA or
W-40 plywood, 24-inch or more layers, any with Trufast 3” Metal None AA, SBS-TA or -75.0
Shield 1.3 ft2 H APP-TA
span combination, loose laid Insulation Plate APP-TA

NEMO ETC, LLC 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Evaluation Report 3520.03.04-R30 for FL2533-R29
Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 30: 01/26/2023
©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 10 of 74
NEMO|etc.
TABLE 1D: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER
System Deck Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP
Primer
No. (Note 1) (Note 3, Note 13) Type Fasten (Note 11) Attach Base Ply Ply Cap Ply (psf)
Min. 19/32-inch (Optional) One or more
Min. 1.5-inch ACFoam II, 1 per SBS-SA- (Optional) SBS-
W-41 plywood, 24-inch layers, any combination, Note 2 None APP-TA -82.5
ENRGY 3 or Multi-Max FA3 1.3 ft2 H TA or APP-TA
span loose laid
CONVENTIONAL SYSTEMS:
Min. 0.5-inch Structodek High (Optional) BP-
Min. 23/32-inch (Optional) One or more
Density Fiberboard Roof 1 per BP-AA or AA, SBS-AA, SBS-AA or
W-42 plywood, 24-inch layers, any combination, Note 2 None -45.0*
Insulation, min. 0.75-inch 2.0 ft2 SBS-AA SBS-TA or APP- APP-TA
span loose laid
FescoBoard (homogeneous) TA
BP-AA,
Min. 0.25-inch DensDeck, (Optional) BP-
Min. 15/32-inch (Optional) One or more Trufast #12 DP or #14 HD SBS-AA,
DensDeck Prime or 1 per AA, SBS-AA, SBS-AA or
W-43 plywood, 24-inch layers, any combination, with Trufast 3” Metal None SBS-TA -45.0*
SECUROCK Gypsum-Fiber 2.0 ft2 SBS-TA or APP- APP-TA
span loose laid Insulation Plate or APP-
Roof Board TA
TA
Min. 15/32-inch (Optional for Recover) Min. Trufast #12 DP or #14 HD
Min. 0.25-inch SECUROCK 1 per (Optional) APP-
W-44 plywood, 24-inch 1.5-inch, One or more layers, with Trufast 3” Metal None APP-TA APP-TA -60.0
Gypsum-Fiber Roof Board 1.45 ft2 TA
span any combination, loose laid Insulation Plate
BP-AA,
(Optional) BP-
Min. 19/32-inch Min. 2-inch ACFoam II, Trufast #12 DP or #14 HD SBS-AA,
Min. 0.5-inch SECUROCK 1 per AA, SBS-AA, SBS-AA or
W-45 plywood, 24-inch ENRGY 3 or H-Shield, loose with Trufast 3” Metal None SBS-TA -60.0
Gypsum-Fiber Roof Board 1.8 ft2 SBS-TA or APP- APP-TA
span laid. Insulation Plate or APP-
TA
TA
Min. 15/32-inch (Optional for Recover) Min. Trufast #12 DP or #14 HD
Min. 0.25-inch SECUROCK 1 per (Optional) APP-
W-46 plywood, 24-inch 1.5-inch, One or more layers, with Trufast 3” Metal None APP-TA APP-TA -67.5
Gypsum-Fiber Roof Board 1.3 ft2 TA
span any combination, loose laid Insulation Plate

NEMO ETC, LLC 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Evaluation Report 3520.03.04-R30 for FL2533-R29
Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 30: 01/26/2023
©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 11 of 74
NEMO|etc.
TABLE 1E: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE D-2: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
Insulation Layer(s)
System Deck Base Sheet Roof Cover (Note 15) MDP
(Note 3, Note 13) Primer
No. (Note 1) (psf)
Type Attach Type Fasten (Note 11) Attach Base Ply Cap Ply
SELF-ADHERING SYSTEMS:
8-inch o.c. at min. 3-inch lap
Min. 19/32- Min. 1.5-inch, One FlintPrime
Prelim. and 8-inch o.c. in two (2), (Optional)
W-47 inch plywood, or more layers, Flintlastic SA NailBase Note 2 QD at stress SBS-SA -82.5*
Attach equally spaced, staggered SBS-SA
24-inch span any combination plates
center rows
OMG #14 HD with OMG 3
6-inch o.c. at min. 2-inch lap
Min. 15/32- Min. 1.5-inch, One in. Round Metal Plate or FlintPrime
Prelim. and 6-inch o.c. in three (3), (Optional)
W-48 inch plywood, or more layers, Flintlastic SA NailBase Trufast #12 DP or #14 HD QD at stress SBS-SA -97.5*
Attach equally spaced, staggered SBS-SA
24-inch span any combination with Trufast 3” Metal plates
center rows
Insulation Plate
OMG #14 HD with OMG 3
6-inch o.c. at min. 2-inch lap
Min. 15/32- Min. 1.5-inch, One in. Round Metal Plate or FlintPrime
Prelim. and 6-inch o.c. in four (4), (Optional)
W-49 inch plywood, or more layers, Flintlastic SA NailBase Trufast #12 DP or #14 HD QD at stress SBS-SA -127.5*
Attach equally spaced, staggered SBS-SA
24-inch span any combination with Trufast 3” Metal plates
center rows
Insulation Plate
HYBRID SYSTEMS:
OMG #14 HD with OMG 3
Glasbase Base Sheet, Flintlastic
Min. 15/32- Min. 1.5-inch, One in. Round Metal Plate or 6-inch o.c. at 4-inch lap and 6- FlintPrime
Prelim. Base 20, Flintlastic Poly SMS SBS-AA or
W-50 inch plywood, or more layers, Trufast #12 DP or #14 HD inch o.c. in three (3), equally QD at stress SBS-SA-H -97.5
Attach Base Sheet, Flintlastic Ultra APP-TA
24-inch span any combination with Trufast 3” Metal spaced, staggered center rows plates
Poly SMS Base Sheet
Insulation Plate
Glasbase Base Sheet, Flintlastic
Min. 19/32- Min. 1.5-inch, One 7-inch o.c. at 3-inch lap and 7-
Prelim. Base 20, Flintlastic Poly SMS SBS-AA or
W-51 inch plywood, or more layers, Note 2 inch o.c. in three (3), equally None SBS-SA-H -105.0
Attach Base Sheet, Flintlastic Ultra APP-TA
24-inch span any combination spaced, staggered center rows
Poly SMS Base Sheet
OMG #14 HD with OMG 3
Glasbase Base Sheet, Flintlastic
Min. 15/32- Min. 1.5-inch, One in. Round Metal Plate or 6-inch o.c. at 4-inch lap and 6- FlintPrime
Prelim. Base 20, Flintlastic Poly SMS SBS-AA or
W-52 inch plywood, or more layers, Trufast #12 DP or #14 HD inch o.c. in four (4), equally QD at stress SBS-SA-H -127.5
Attach Base Sheet, Flintlastic Ultra APP-TA
24-inch span any combination with Trufast 3” Metal spaced, staggered center rows plates
Poly SMS Base Sheet
Insulation Plate
CONVENTIONAL SYSTEMS:
Glasbase Base Sheet, All
Min. 23/32- Min. 1.5-inch, One 12-inch o.c. at 4-inch lap and BP-AA, SBS-
Prelim. Weather/Empire Base Sheet, SBS-AA or
W-53 inch plywood, or more layers, Note 2 36-inch o.c. in two (2), equally None AA, SBS-TA -30.0*
Attach Flintlastic Base 20 or Flintglas APP-TA
24-inch span any combination spaced, staggered center rows or APP-TA
MS Cap (inverted)

NEMO ETC, LLC 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Evaluation Report 3520.03.04-R30 for FL2533-R29
Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 30: 01/26/2023
©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 12 of 74
NEMO|etc.
TABLE 1E: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE D-2: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
Insulation Layer(s)
System Deck Base Sheet Roof Cover (Note 15) MDP
(Note 3, Note 13) Primer
No. (Note 1) (psf)
Type Attach Type Fasten (Note 11) Attach Base Ply Cap Ply
Glasbase Base Sheet, All
Min. 23/32- Min. 1.5-inch, One 12-inch o.c. at 4-inch lap and BP-AA, SBS-
Prelim. Weather/Empire Base Sheet, SBS-AA or
W-54 inch plywood, or more layers, Note 2 24-inch o.c. in two (2), equally None AA, SBS-TA -45.0*
Attach Flintlastic Base 20 or Flintglas APP-TA
24-inch span any combination spaced, staggered center rows or APP-TA
MS Cap (inverted)
Min. 23/32- Min. 1.5-inch, One Flintlastic Poly SMS Base 12-inch o.c. at 4-inch lap and BP-AA, SBS-
Prelim. SBS-AA or
W-55 inch plywood, or more layers, Sheet, Flintlastic Ultra Poly Note 2 36-inch o.c. in two (2), equally None AA, SBS-TA -45.0*
Attach APP-TA
24-inch span any combination SMS Base Sheet spaced, staggered center rows or APP-TA
Glasbase Base Sheet, Flintlastic
OMG #14 HD with OMG 3
Base 20, All Weather/Empire (Optional)
Min. 15/32- Min. 1.5-inch, One in. Round Metal Plate or 6-inch o.c. at 4-inch lap and 6-
Prelim. Base Sheet, Flintlastic Poly BP-AA, SBS- SBS-AA or
W-56 inch plywood, or more layers, Trufast #12 DP or #14 HD inch o.c. in three (3), equally None -97.5
Attach SMS Base Sheet, Flintlastic AA, SBS-TA APP-TA
24-inch span any combination with Trufast 3” Metal spaced, staggered center rows.
Ultra Poly SMS Base Sheet or or APP-TA
Insulation Plate
Flintglas MS Cap (inverted)
Min. 15/32- Min. 1.5-inch, One 6-inch o.c. at 4-inch lap and 6-
Prelim. OMG #14 HD with OMG 3
W-57 inch plywood, or more layers, Flintlastic APP Base T inch o.c. in three (3), equally None APP-TA APP-TA -97.5
Attach in. Round Metal Plates
24-inch span any combination spaced, staggered center rows.
Glasbase Base Sheet, Flintlastic
One or more Base 20, All Weather/Empire (Optional)
Min. 15/32- 8-inch o.c. at 4-inch lap and 8-
layers, any Prelim. Base Sheet, Flintlastic Poly Trufast #14 HD with Trufast BP-AA, SBS- SBS-AA or
W-58 inch plywood, inch o.c. at three (3) equally None -97.5
thickness or Attach SMS Base Sheet, Flintlastic 3” Metal Insulation Plate AA, SBS-TA APP-TA
24-inch span spaced, staggered center rows
combination Ultra Poly SMS Base Sheet or or APP-TA
Flintglas MS Cap (inverted)
Glasbase Base Sheet, Flintlastic
Min. 19/32- Min. 1.5-inch, One Base 20, Flintlastic Poly SMS 7-inch o.c. at 3-inch lap and 7- BP-AA, SBS-
Prelim. SBS-AA or
W-59 inch plywood, or more layers, Base Sheet, Flintlastic Ultra Note 2 inch o.c. in three (3), equally None AA, SBS-TA -105.0
Attach APP-TA
24-inch span any combination Poly SMS Base Sheet or spaced, staggered center rows or APP-TA
Flintglas MS Cap (inverted)
Dekfast DF-#14-PH3 with
Min. 19/32- Min. 1.5-inch, One 7-inch o.c. at 3-inch lap and 7-
Prelim. PLT-H-2-7/8 or OMG #14 HD
W-60 inch plywood, or more layers, Flintlastic APP Base T inch o.c. in three (3), equally None APP-TA APP-TA -105.0
Attach with OMG 3 in. Round
24-inch span any combination spaced, staggered center rows
Metal Plate
Glasbase Base Sheet, Flintlastic OMG #14 HD with OMG 3
(Optional)
Min. 15/32- Min. 1.5-inch, One Base 20, Flintlastic Poly SMS in. Round Metal Plate or 6-inch o.c. at 4-inch lap and 6-
Prelim. BP-AA, SBS- SBS-AA or
W-61 inch plywood, or more layers, Base Sheet, Flintlastic Ultra Trufast #12 DP or #14 HD inch o.c. in four (4), equally None -127.5
Attach AA, SBS-TA APP-TA
24-inch span any combination Poly SMS Base Sheet or with Trufast 3” Metal spaced, staggered center rows.
or APP-TA
Flintglas MS Cap (inverted) Insulation Plate

NEMO ETC, LLC 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Evaluation Report 3520.03.04-R30 for FL2533-R29
Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 30: 01/26/2023
©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 13 of 74
NEMO|etc.
TABLE 1E: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE D-2: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
Insulation Layer(s)
System Deck Base Sheet Roof Cover (Note 15) MDP
(Note 3, Note 13) Primer
No. (Note 1) (psf)
Type Attach Type Fasten (Note 11) Attach Base Ply Cap Ply
Min. 15/32- Min. 1.5-inch, One 6-inch o.c. at 4-inch lap and 6-
Prelim. OMG #14 HD with OMG 3
W-62 inch plywood, or more layers, Flintlastic APP Base T inch o.c. in four (4), equally None APP-TA APP-TA -127.5
Attach in. Round Metal Plates
24-inch span any combination spaced, staggered center rows.
COLD-APPLIED SYSTEMS:
Glasbase Base Sheet, Flintlastic
Base 20, All Weather/Empire
Min. 15/32- Min. 1-inch, One Trufast #12 DP or #14 HD 8-inch o.c. at 4-inch lap and 8-
Loose- Base Sheet, Flintlastic Poly (Optional)
W-63 inch plywood, or more layers, with Trufast 3” Metal inch o.c. in three (3), equally None SBS-CA1 -52.5
laid SMS Base Sheet, Flintlastic SBS-CA1
24-inch span any combination Insulation Plate spaced, staggered center rows
Ultra Poly SMS Base Sheet or
Flintglas MS Cap (inverted)

TABLE 1F: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)


SYSTEM TYPE E-2: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
System Deck Base Sheet Roof Cover (Note 15) MDP
Primer
No. (Note 1) Base Fasten (Note 11) Attach Base Ply Cap Ply (psf)
SELF-ADHERING SYSTEMS:
FlintPrime
Min. 15/32-inch 9-inch o.c. at min. 3-inch lap and 12-inch
QD at (Optional)
W-64 plywood, 24-inch Flintlastic SA NailBase Simplex MAXX Cap o.c. in two (2), equally spaced, staggered SBS-SA -45.0*
stress SBS-SA
span center rows
plates
Min. 15/32-inch 6-inch o.c. at min. 2-inch lap and 6-inch
Min. 1-inch long, 12 ga. Simplex (Optional)
W-65 plywood, 24-inch Flintlastic SA NailBase o.c. in four (4), equally spaced, None SBS-SA -52.5
Metal Cap Nails SBS-SA
span staggered center rows
Min. 19/32-inch 32 ga., 1-5/8-inch dia. tin caps 8-inch o.c. at min. 2-inch lap and 8-inch
(Optional)
W-66 plywood, 24-inch Flintlastic SA NailBase with 11 ga. annular ring shank o.c. in three (3), equally spaced, None SBS-SA -52.5
SBS-SA
span nails staggered center rows
APA rated, min. FlintPrime (Optional)
8-inch o.c. at min. 3-inch lap and 8-inch
7/16 CAT, 0.418 QD at Flintlastic SA
W-67 Flintlastic SA NailBase Simplex MAXX Cap o.c. in three (3), equally spaced, SBS-SA -52.5
in., Exposure 1, stress Mid Ply, self-
staggered center rows
OSB, 24-inch span plates adhering
Min. 19/32-inch 32 ga., 1-5/8-inch dia. tin caps 8-inch o.c. at min. 2-inch lap and 8-inch
(Optional)
W-68 plywood, 24-inch Flintlastic SA NailBase with 11 ga. annular ring shank o.c. in three (3), equally spaced, None SBS-SA -60.0
SBS-SA
span nails staggered center rows
FlintPrime
Min. 15/32-inch 8-inch o.c. at min. 3-inch lap and 8-inch
QD at (Optional)
W-69 plywood, 24-inch Flintlastic SA NailBase Simplex MAXX Cap o.c. in three (3), equally spaced, SBS-SA -67.5
stress SBS-SA
span staggered center rows
plates

NEMO ETC, LLC 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Evaluation Report 3520.03.04-R30 for FL2533-R29
Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 30: 01/26/2023
©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 14 of 74
NEMO|etc.
TABLE 1F: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE E-2: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
System Deck Base Sheet Roof Cover (Note 15) MDP
Primer
No. (Note 1) Base Fasten (Note 11) Attach Base Ply Cap Ply (psf)
Min. 19/32-inch 32 ga., 1-5/8-inch dia. tin caps 6-inch o.c. at min. 2-inch lap and 6-inch
(Optional)
W-70 plywood, 24-inch Flintlastic SA NailBase with 11 ga. annular ring shank o.c. in four (4), equally spaced, None SBS-SA -75.0
SBS-SA
span nails staggered center rows
Min. 15/32-inch Cap nails: 1-inch diameter, 0.032- 7-inch o.c. at min. 4-inch laps and 7-inch
(Optional)
W-71 plywood, 24-inch Flintlastic SA NailBase inch metal cap with 0.120" shank o.c. in five (5), equally spaced, staggered None SBS-SA -75.0
SBS-SA
span diameter, annular ring shank nails center rows
Min. 19/32-inch 32 ga., 1-5/8-inch dia. tin caps 4-inch o.c. at min. 2-inch lap and 4-inch
(Optional)
W-72 plywood, 24-inch Flintlastic SA NailBase with 11 ga. annular ring shank o.c. in four (4), equally spaced, None SBS-SA -105.0
SBS-SA
span nails staggered center rows
HYBRID SYSTEMS:
Glasbase Base Sheet, Flintlastic Base 20, All
Min. 19/32-inch 32 ga., 1-5/8-inch dia. tin caps 9-inch o.c. at 4-inch lap and 12-inch o.c.
Weather/Empire Base Sheet, Flintlastic Poly SBS-AA or
W-73 plywood, 24-inch with 11 ga. annular ring shank in two (2), equally spaced, staggered None SBS-SA-H -45.0*
SMS Base Sheet, Flintlastic Ultra Poly SMS APP-TA
span nails center rows
Base Sheet
Glasbase Base Sheet, Flintlastic Base 20, All
Min. 15/32-inch 6-inch o.c. at 3-inch lap and 6-inch o.c. in
Weather/Empire Base Sheet, Flintlastic Poly Min. 1-inch long, 12 ga. Simplex SBS-AA or
W-74 plywood, 24-inch four (4), equally spaced, staggered None SBS-SA-H -52.5
SMS Base Sheet, Flintlastic Ultra Poly SMS Metal Cap Nails APP-TA
span center rows
Base Sheet
Min. 19/32-inch Glasbase Base Sheet, Flintlastic Base 20, 32 ga., 1-5/8-inch dia. tin caps 8-inch o.c. at 4-inch lap and 8-inch o.c. in
SBS-AA or
W-75 plywood, 24-inch Flintlastic Poly SMS Base Sheet, Flintlastic with 11 ga. annular ring shank three (3), equally spaced, staggered None SBS-SA-H -52.5
APP-TA
span Ultra Poly SMS Base Sheet nails center rows
Min. 19/32-inch Glasbase Base Sheet, Flintlastic Base 20, 32 ga., 1-5/8-inch dia. tin caps 8-inch o.c. at 4-inch lap and 8-inch o.c. in
SBS-AA or
W-76 plywood, 24-inch Flintlastic Poly SMS Base Sheet, Flintlastic with 11 ga. annular ring shank three (3), equally spaced, staggered None SBS-SA-H -60.0
APP-TA
span Ultra Poly SMS Base Sheet nails center rows
Min. 19/32-inch Glasbase Base Sheet, Flintlastic Base 20, 32 ga., 1-5/8-inch dia. tin caps 6-inch o.c. at 4-inch lap and 6-inch o.c. in
SBS-AA or
W-77 plywood, 24-inch Flintlastic Poly SMS Base Sheet, Flintlastic with 11 ga. annular ring shank four (4), equally spaced, staggered None SBS-SA-H -82.5
APP-TA
span Ultra Poly SMS Base Sheet nails center rows
Min. 19/32-inch Glasbase Base Sheet, Flintlastic Base 20, 32 ga., 1-5/8-inch dia. tin caps 4-inch o.c. at 3-inch lap and 4-inch o.c. in
SBS-AA or
W-78 plywood, 24-inch Flintlastic Poly SMS Base Sheet, Flintlastic with 11 ga. annular ring shank four (4), equally spaced, staggered None SBS-SA-H -105.0
APP-TA
span Ultra Poly SMS Base Sheet nails center rows
CONVENTIONAL SYSTEMS:
Glasbase Base Sheet, Flintlastic Base 20, All
Min. 19/32-inch 32 ga., 1-5/8-inch dia. tin caps 9-inch o.c. at 4-inch lap and 12-inch o.c. BP-AA, SBS-
Weather/Empire Base Sheet, Flintlastic Poly SBS-AA or
W-79 plywood, 24-inch with 11 ga. annular ring shank in two (2), equally spaced, staggered None AA, SBS-TA or -45.0*
SMS Base Sheet, Flintlastic Ultra Poly SMS APP-TA
span nails center rows APP-TA
Base Sheet or Flintglas MS Cap (inverted)

NEMO ETC, LLC 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Evaluation Report 3520.03.04-R30 for FL2533-R29
Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 30: 01/26/2023
©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 15 of 74
NEMO|etc.
TABLE 1F: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE E-2: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
System Deck Base Sheet Roof Cover (Note 15) MDP
Primer
No. (Note 1) Base Fasten (Note 11) Attach Base Ply Cap Ply (psf)
Glasbase Base Sheet, Flintlastic Base 20, All (Optional) BP-
Min. 15/32-inch 9-inch o.c. at 2-inch lap and 18-inch o.c.
Weather/Empire Base Sheet, Flintlastic Poly AA, SBS-AA, SBS-AA or
W-80 plywood, 24-inch Simplex MAXX Cap in two (2), equally spaced, staggered None -45.0*
SMS Base Sheet or Flintglas MS Cap SBS-TA or APP-TA
span center rows
(inverted) APP-TA
Min. 15/32-inch 9-inch o.c. at 2-inch lap and 18-inch o.c.
(Optional)
W-81 plywood, 24-inch Flintlastic APP Base T Simplex MAXX Cap in two (2), equally spaced, staggered None APP-TA -45.0*
APP-TA
span center rows
Glasbase Base Sheet, Flintlastic Base 20, All (Optional) BP-
Min. 15/32-inch 6-inch o.c. at 3-inch lap and 6-inch o.c. in
Weather/Empire Base Sheet, Flintlastic Poly Min. 1-inch long, 12 ga. Simplex AA, SBS-AA, SBS-AA or
W-82 plywood, 24-inch four (4), equally spaced, staggered None -52.5
SMS Base Sheet, Flintlastic Ultra Poly SMS Metal Cap Nails SBS-TA or APP-TA
span center rows
Base Sheet or Flintglas MS Cap (inverted) APP-TA
Glasbase Base Sheet, Flintlastic Base 20, All
Min. 19/32-inch 32 ga., 1-5/8-inch dia. tin caps 8-inch o.c. at 4-inch lap and 8-inch o.c. in BP-AA, SBS-
Weather/Empire Base Sheet, Flintlastic Poly SBS-AA or
W-83 plywood, 24-inch with 11 ga. annular ring shank three (3), equally spaced, staggered None AA, SBS-TA or -52.5
SMS Base Sheet, Flintlastic Ultra Poly SMS APP-TA
span nails center rows APP-TA
Base Sheet or Flintglas MS Cap (inverted)
Glasbase Base Sheet, Flintlastic Base 20, All (Optional) BP-
Min. 15/32-inch 9-inch o.c. at 2-inch lap and 12-inch o.c.
Weather/Empire Base Sheet, Flintlastic Poly AA, SBS-AA, SBS-AA or
W-84 plywood, 24-inch Simplex MAXX Cap in two (2), equally spaced, staggered None -52.5
SMS Base Sheet or Flintglas MS Cap SBS-TA or APP-TA
span center rows
(inverted) APP-TA
Min. 15/32-inch 9-inch o.c. at 2-inch lap and 12-inch o.c.
(Optional)
W-85 plywood, 24-inch Flintlastic APP Base T Simplex MAXX Cap in two (2), equally spaced, staggered None APP-TA -52.5
APP-TA
span center rows
Glasbase Base Sheet, Flintlastic Base 20, All
Min. 19/32-inch 32 ga., 1-5/8-inch dia. tin caps 8-inch o.c. at 4-inch lap and 8-inch o.c. in BP-AA, SBS-
Weather/Empire Base Sheet, Flintlastic Poly SBS-AA or
W-86 plywood, 24-inch with 11 ga. annular ring shank three (3), equally spaced, staggered None AA, SBS-TA or -60.0
SMS Base Sheet, Flintlastic Ultra Poly SMS APP-TA
span nails center rows APP-TA
Base Sheet or Flintglas MS Cap (inverted)
Glasbase Base Sheet, Flintlastic Base 20, All Cap nails: 1-inch diameter, 0.032-
Min. 15/32-inch 6-inch o.c. at 4-inch lap and 6-inch o.c. (Optional) BP-
Weather/Empire Base Sheet, Flintlastic Poly inch metal cap with 0.120-inch
W-87 plywood, 24-inch at five (5) equally spaced, staggered None AA, SBS-AA or SBS-AA -67.5
SMS Base Sheet, Flintlastic Ultra Poly SMS shank diameter, annular ring
span center rows SBS-TA
Base Sheet or Flintglas MS Cap (inverted) shank nails.
Glasbase Base Sheet, Flintlastic Base 20, All
Min. 19/32-inch 32 ga., 1-5/8-inch dia. tin caps 6-inch o.c. at 4-inch lap and 6-inch o.c. in BP-AA, SBS-
Weather/Empire Base Sheet, Flintlastic Poly SBS-AA or
W-88 plywood, 24-inch with 11 ga. annular ring shank four (4), equally spaced, staggered None AA, SBS-TA or -82.5
SMS Base Sheet, Flintlastic Ultra Poly SMS APP-TA
span nails center rows APP-TA
Base Sheet or Flintglas MS Cap (inverted)
Glasbase Base Sheet, Flintlastic Base 20, All (Optional) BP-
Min. 15/32-inch 6-inch o.c. at 2-inch lap and 6-inch o.c. in
Weather/Empire Base Sheet, Flintlastic Poly AA, SBS-AA, SBS-AA or
W-89 plywood, 24-inch Simplex MAXX Cap two (2), equally spaced, staggered None -90.0
SMS Base Sheet or Flintglas MS Cap SBS-TA or APP-TA
span center rows
(inverted) APP-TA

NEMO ETC, LLC 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Evaluation Report 3520.03.04-R30 for FL2533-R29
Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 30: 01/26/2023
©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 16 of 74
NEMO|etc.
TABLE 1F: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE E-2: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
System Deck Base Sheet Roof Cover (Note 15) MDP
Primer
No. (Note 1) Base Fasten (Note 11) Attach Base Ply Cap Ply (psf)
Min. 15/32-inch 6-inch o.c. at 2-inch lap and 6-inch o.c. in
(Optional)
W-90 plywood, 24-inch Flintlastic APP Base T Simplex MAXX Cap two (2), equally spaced, staggered None APP-TA -90.0
APP-TA
span center rows
Glasbase Base Sheet, Flintlastic Base 20, All
Min. 19/32-inch 32 ga., 1-5/8-inch dia. tin caps 4-inch o.c. at 3-inch lap and 4-inch o.c. in BP-AA, SBS-
Weather/Empire Base Sheet, Flintlastic Poly SBS-AA or
W-91 plywood, 24-inch with 11 ga. annular ring shank four (4), equally spaced, staggered None AA, SBS-TA or -105.0
SMS Base Sheet, Flintlastic Ultra Poly SMS APP-TA
span nails center rows APP-TA
Base Sheet or Flintglas MS Cap (inverted)
Glasbase Base Sheet, Flintlastic Base 20, All (Optional) BP-
Min. 15/32-inch 6-inch o.c. at 2-inch lap and 6-inch o.c. in
Weather/Empire Base Sheet, Flintlastic Poly AA, SBS-AA, SBS-AA or
W-92 plywood, 24-inch Simplex MAXX Cap three (3), equally spaced, staggered None -105.0
SMS Base Sheet or Flintglas MS Cap SBS-TA or APP-TA
span center rows
(inverted) APP-TA
Min. 15/32-inch 6-inch o.c. at 2-inch lap and 6-inch o.c. in
(Optional)
W-93 plywood, 24-inch Flintlastic APP Base T Simplex MAXX Cap three (3), equally spaced, staggered None APP-TA -105.0
APP-TA
span center rows

TABLE 1G: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER


SYSTEM TYPE E-2: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
System Deck Base Sheet Roof Cover (Note 15) MDP
Primer
No. (Note 1) Base Fasten (Note 11) Attach Base Ply Cap Ply (psf)
SELF-ADHERING SYSTEMS:
APA rated, min. (Optional)
9-inch o.c. at min. 3-inch lap and FlintPrime QD
7/16 CAT, 0.418 in., Trufast Versa Fastener & Plates, two (2) Flintlastic SA
Flintlastic SA NailBase 12-inch o.c. in two (2), equally at stress SBS-SA -60.0*
Exposure 1, OSB, screws per plate at 180° from each other* Mid Ply, self-
W-94 spaced, staggered center rows plates
24-inch span adhering
Note: *For re-roof (tear-off) or recover applications, field withdrawal resistance testing (Note 11) shall yield minimum 109 lbf. Additional Versa-Fast Fasteners within each Versa-Fast Plate may
be utilized to produce minimum withdrawal resistance. For recover installations, screws shall be of sufficient length for minimum 1” penetration through OSB sheathing.
Min. 19/32-inch 8-inch o.c. at min. 3-inch lap and FlintPrime QD
(Optional)
W-95 plywood, 24-inch Flintlastic SA NailBase Note 2 8-inch o.c. in two (2), equally at stress SBS-SA -82.5*
SBS-SA
span spaced, staggered center rows plates
Min. 15/32-inch OMG #14 HD with OMG 3 in. Round Metal 6-inch o.c. at min. 2-inch lap and FlintPrime QD
(Optional)
W-96 plywood, 24-inch Flintlastic SA NailBase Plate or Trufast #12 DP or #14 HD with Trufast 6-inch o.c. in three (3), equally at stress SBS-SA -97.5*
SBS-SA
span 3” Metal Insulation Plate spaced, staggered center rows plates
Min. 15/32-inch OMG #14 HD with OMG 3 in. Round Metal 6-inch o.c. at min. 2-inch lap and FlintPrime QD
(Optional)
W-97 plywood, 24-inch Flintlastic SA NailBase Plate or Trufast #12 DP or #14 HD with Trufast 6-inch o.c. in four (4), equally at stress SBS-SA -127.5*
SBS-SA
span 3” Metal Insulation Plate spaced, staggered center rows plates
HYBRID SYSTEMS:

NEMO ETC, LLC 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Evaluation Report 3520.03.04-R30 for FL2533-R29
Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 30: 01/26/2023
©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 17 of 74
NEMO|etc.
TABLE 1G: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE E-2: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
System Deck Base Sheet Roof Cover (Note 15) MDP
Primer
No. (Note 1) Base Fasten (Note 11) Attach Base Ply Cap Ply (psf)
Glasbase Base Sheet, Flintlastic
Min. 15/32-inch OMG #14 HD with OMG 3 in. Round Metal 6-inch o.c. at 4-inch lap and 6- FlintPrime QD
Base 20, Flintlastic Poly SMS Base SBS-AA or
W-98 plywood, 24-inch Plate or Trufast #12 DP or #14 HD with Trufast inch o.c. in three (3), equally at stress SBS-SA-H -97.5
Sheet, Flintlastic Ultra Poly SMS APP-TA
span 3” Metal Insulation Plate spaced, staggered center rows plates
Base Sheet
Glasbase Base Sheet, Flintlastic
Min. 19/32-inch 7-inch o.c. at 3-inch lap and 7-
Base 20, Flintlastic Poly SMS Base SBS-AA or
W-99 plywood, 24-inch Note 2 inch o.c. in three (3), equally None SBS-SA-H -105.0
Sheet, Flintlastic Ultra Poly SMS APP-TA
span spaced, staggered center rows
Base Sheet
Glasbase Base Sheet, Flintlastic
Min. 15/32-inch OMG #14 HD with OMG 3 in. Round Metal 6-inch o.c. at 4-inch lap and 6- FlintPrime QD
Base 20, Flintlastic Poly SMS Base SBS-AA or
W-100 plywood, 24-inch Plate or Trufast #12 DP or #14 HD with Trufast inch o.c. in four (4), equally at stress SBS-SA-H -127.5
Sheet, Flintlastic Ultra Poly SMS APP-TA
span 3” Metal Insulation Plate spaced, staggered center rows plates
Base Sheet
CONVENTIONAL SYSTEMS:
Glasbase Base Sheet, All
Min. 23/32-inch 12-inch o.c. at 4-inch lap and 36- BP-AA, SBS-
Weather/Empire Base Sheet, SBS-AA or
W-101 plywood, 24-inch Note 2 inch o.c. in two (2), equally None AA, SBS-TA -30.0*
Flintlastic Base 20 or Flintglas MS APP-TA
span spaced, staggered center rows or APP-TA
Cap (inverted)
Glasbase Base Sheet, All
Min. 23/32-inch 12-inch o.c. at 4-inch lap and 24- BP-AA, SBS-
Weather/Empire Base Sheet, SBS-AA or
W-102 plywood, 24-inch Note 2 inch o.c. in two (2), equally None AA, SBS-TA -45.0*
Flintlastic Base 20 or Flintglas MS APP-TA
span spaced, staggered center rows or APP-TA
Cap (inverted)
Min. 23/32-inch Flintlastic Poly SMS Base Sheet, 12-inch o.c. at 4-inch lap and 36- BP-AA, SBS-
SBS-AA or
W-103 plywood, 24-inch Flintlastic Ultra Poly SMS Base Note 2 inch o.c. in two (2), equally None AA, SBS-TA -45.0*
APP-TA
span Sheet spaced, staggered center rows or APP-TA
Glasbase Base Sheet, Flintlastic
(Optional)
Min. 15/32-inch Base 20, Flintlastic Poly SMS Base OMG #14 HD with OMG 3 in. Round Metal 6-inch o.c. at 4-inch lap and 6-
BP-AA, SBS- SBS-AA or
W-104 plywood, 24-inch Sheet, Flintlastic Ultra Poly SMS Plate or Trufast #12 DP or #14 HD with Trufast inch o.c. in three (3), equally None -97.5
AA, SBS-TA APP-TA
span Base Sheet or Flintglas MS Cap 3” Metal Insulation Plate spaced, staggered center rows
or APP-TA
(inverted)
Min. 15/32-inch 6-inch o.c. at 4-inch lap and 6-
OMG #14 HD with OMG 3 in. Round Metal
W-105 plywood, 24-inch Flintlastic APP Base T inch o.c. in three (3), equally None APP-TA APP-TA -97.5
Plates
span spaced, staggered center rows.
Glasbase Base Sheet, Flintlastic
Base 20, All Weather/Empire Base
Min. 15/32-inch 8-inch o.c. at 4-inch lap and 8- (Optional)
Sheet, Flintlastic Poly SMS Base Trufast #14 HD with Trufast 3” Metal
W-106 plywood, 24-inch inch o.c. at three (3) equally None BP-AA, SBS- SBS-AA -97.5
Sheet, Flintlastic Ultra Poly SMS Insulation Plate
span spaced, staggered center rows AA or SBS-TA
Base Sheet or Flintglas MS Cap
(inverted)

NEMO ETC, LLC 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Evaluation Report 3520.03.04-R30 for FL2533-R29
Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 30: 01/26/2023
©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 18 of 74
NEMO|etc.
TABLE 1G: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE E-2: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
System Deck Base Sheet Roof Cover (Note 15) MDP
Primer
No. (Note 1) Base Fasten (Note 11) Attach Base Ply Cap Ply (psf)
Glasbase Base Sheet, Flintlastic
Min. 19/32-inch Base 20, Flintlastic Poly SMS Base 7-inch o.c. at 3-inch lap and 7- BP-AA, SBS-
SBS-AA or
W-107 plywood, 24-inch Sheet, Flintlastic Ultra Poly SMS Note 2 inch o.c. in three (3), equally None AA, SBS-TA -105.0
APP-TA
span Base Sheet or Flintglas MS Cap spaced, staggered center rows or APP-TA
(inverted)
Min. 19/32-inch 7-inch o.c. at 3-inch lap and 7-
Dekfast DF-#14-PH3 with PLT-H-2-7/8 or OMG
W-108 plywood, 24-inch Flintlastic APP Base T inch o.c. in three (3), equally None APP-TA APP-TA -105.0
#14 HD with OMG 3 in. Round Metal Plate
span spaced, staggered center rows
Glasbase Base Sheet, Flintlastic
(Optional)
Min. 15/32-inch Base 20, Flintlastic Poly SMS Base OMG #14 HD with OMG 3 in. Round Metal 6-inch o.c. at 4-inch lap and 6-
BP-AA, SBS- SBS-AA or
W-109 plywood, 24-inch Sheet, Flintlastic Ultra Poly SMS Plate or Trufast #12 DP or #14 HD with Trufast inch o.c. in four (4), equally None -127.5
AA, SBS-TA APP-TA
span Base Sheet or Flintglas MS Cap 3” Metal Insulation Plate spaced, staggered center rows
or APP-TA
(inverted)
Min. 15/32-inch 6-inch o.c. at 4-inch lap and 6-
OMG #14 HD with OMG 3 in. Round Metal
W-110 plywood, 24-inch Flintlastic APP Base T inch o.c. in four (4), equally None APP-TA APP-TA -127.5
Plates
span spaced, staggered center rows.
COLD-APPLIED SYSTEMS:
Glasbase Base Sheet, Flintlastic
Base 20, All Weather/Empire Base
Min. 15/32-inch 8-inch o.c. at 4-inch lap and 8-
Sheet, Flintlastic Poly SMS Base Trufast #12 DP or #14 HD with Trufast 3” (Optional)
W-111 plywood, 24-inch inch o.c. in three (3), equally None SBS-CA1 -52.5
Sheet, Flintlastic Ultra Poly SMS Metal Insulation Plate SBS-CA1
span spaced, staggered center rows
Base Sheet or Flintglas MS Cap
(inverted)

TABLE 1H: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)


SYSTEM TYPE F: NON-INSULATED, BONDED ROOF COVER
System Deck Roof Cover (Note 15)
Primer MDP (psf)
No. (Note 1) Base Ply Ply Cap Ply
APA rated, min. 7/16 CAT, 0.418 in., Exposure 1,
W-112 FlintPrime QD Flintlastic SA Mid Ply, self-adhering (Optional) SBS-SA SBS-SA -90.0
OSB sheathing, 24-inch span
W-113 Min. 15/32-inch plywood, 24-inch span FlintPrime QD SBS-SA-H (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -112.5
W-114 Min. 15/32-inch plywood, 24-inch span FlintPrime QD SBS-SA (Optional) SBS-SA SBS-SA -127.5

NEMO ETC, LLC 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Evaluation Report 3520.03.04-R30 for FL2533-R29
Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 30: 01/26/2023
©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 19 of 74
NEMO|etc.
TABLE 2A: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER
Base Insulation Layer Top Insulation Layer Roof Cover (Note 15)
System Deck MDP
No. (Note 1)
Attach (psf)
Type Fasten (Note 11) Attach Type Base Ply Ply Cap Ply
(Notes 6,7,8)
SELF-ADHERING SYSTEMS:
Optional min. 1.5-inch
hot asphalt, M-
Min. 22 ga., type B, Grade Min. 2-inch additional layer(s) base
1 per OSFA, Insta Stik, (Optional) SBS-
S-1 33 steel or min. 2,500 psi ACFoam II, ENRGY Note 2 insulation, followed by min. SBS-SA SBS-SA -37.5*
4.0 ft2 OB500, Polyset SA
structrual concrete 3 or H-Shield 0.25-inch SECUROCK
BM, Polyset CRA
Gypsum-Fiber Roof Board
Optional min. 1.5-inch
hot asphalt, M-
Min. 22 ga., type B, Grade Min. 1.5-inch additional layer(s) base
1 per OSFA, Insta Stik, (Optional) SBS-
S-2 33 steel or min. 2,500 psi ACFoam II, ENRGY Note 2 insulation, followed by min. SBS-SA SBS-SA -45.0*
2.0 ft2 OB500, Polyset SA
structrual concrete 3 or H-Shield 0.25-inch SECUROCK
BM, Polyset CRA
Gypsum-Fiber Roof Board
Min. 22 ga., type B, Grade Min. 2-inch
1 per Min. 2-inch H-Shield HD (Optional) SBS-
S-3 40 steel or min. 2,500 psi ACFoam II or H- Note 2 M-OSFA or M-PG1 SBS-SA SBS-SA -45.0
2.7 ft2 Composite SA
structrual concrete Shield
HYBRID SYSTEMS:
hot asphalt, M-
Min. 22 ga., type B, Grade Min. 1.5-inch Flintlastic (Optional) SBS-
1 per Additional layer(s) base OSFA, Insta Stik, SBS-AA,
S-4 33 steel or min. 2,500 psi ACFoam II, ENRGY Note 2 Ultra Glass AA, SBS-TA, APP- -37.5
1.45 ft2 insulation OB500, Polyset APP-TA
structrual concrete 3 or H-Shield SA TA
BM, Polyset CRA
Min. 22 ga., type B, Grade Min. 2-inch (Optional) BP-
1 per Min. 2-inch H-Shield HD SBS-AA or
S-5 40 steel or min. 2,500 psi ACFoam II or H- Note 2 M-OSFA or M-PG1 SBS-SA-H AA, SBS-AA, SBS- -45.0
2.7 ft2 Composite APP-TA
structrual concrete Shield TA or APP-TA
hot asphalt, M-
Min. 22 ga., type B, Grade Min. 1.5-inch Flintlastic (Optional) SBS-
1 per Min. 0.25-inch SECUROCK OSFA, Insta Stik, SBS-AA,
S-6 33 steel or min. 2,500 psi ACFoam II, ENRGY Note 2 Ultra Glass AA, SBS-TA, APP- -52.5
1.45 ft2 Gypsum-Fiber Roof Board OB500, Polyset APP-TA
structrual concrete 3 or H-Shield SA TA
BM, Polyset CRA
Min. 22 ga., type B, Grade Min. 1.5-inch Trufast #12 DP or #14 HD hot asphalt, M-
1 per Min. 1.5-inch ACFoam II or H- (Optional) APP-
S-7 33 steel or min. 2,500 psi ACFoam II or H- with Trufast 3”Metal OSFA, M-PG1, SBS-SA-H APP-TA -67.5
1.45 ft2 Shield TA
structrual concrete Shield Insulation Plates Insta Stik, OB500
Min. 22 ga., type B, Grade Min. 1.5-inch Trufast #12 DP (steel only)
1 per Min. 0.25-inch SECUROCK M-OSFA, M-PG1, (Optional) SBS-
S-8 40 steel or min. 2,500 psi ACFoam II or H- or #14 HD with Trufast 3” SBS-SA-H APP-TA -75.0
1.6 ft2 Gypsum-Fiber Roof Board Insta Stik, OB500 TA or APP-TA
structrual concrete Shield Metal Insulation Plate
Min. 22 ga., type B, Grade Trufast #12 DP (steel only)
Min. 1.5-inch 1 per Min. 0.5-inch SECUROCK (Optional) SBS-
S-9 33 steel or min. 2,500 psi or #14 HD with Trufast 3” OB500, 4-inch o.c. SBS-SA-H APP-TA -90.0*
ENRGY 3 1.0 ft2 Gypsum-Fiber Roof Board TA or APP-TA
structrual concrete Metal Insulation Plate
CONVENTIONAL SYSTEMS:

NEMO ETC, LLC 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Evaluation Report 3520.03.04-R30 for FL2533-R29
Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 30: 01/26/2023
©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 20 of 74
NEMO|etc.
TABLE 2A: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER
Base Insulation Layer Top Insulation Layer Roof Cover (Note 15)
System Deck MDP
No. (Note 1)
Attach (psf)
Type Fasten (Note 11) Attach Type Base Ply Ply Cap Ply
(Notes 6,7,8)
Optional min. 1.5-inch
hot asphalt, M-
Min. 22 ga., type B, Grade Min. 2-inch additional layer(s) base BP-AA, SBS- (Optional) BP-
1 per OSFA, Insta Stik, SBS-AA or
S-10 33 steel or min. 2,500 psi ACFoam II, ENRGY Note 2 insulation, followed by min. AA, SBS-TA AA, SBS-AA, SBS- -37.5*
4.0 ft2 OB500, Polyset APP-TA
structrual concrete 3 or H-Shield 0.25-inch SECUROCK or APP-TA TA or APP-TA
BM, Polyset CRA
Gypsum-Fiber Roof Board
Optional min. 1.5-inch
additional layer(s) base
Min. 22 ga., type B, Grade Min. 1.5-inch insulation, followed by min. (Optional) BP-
1 per BP-AA or SBS-AA or
S-11 33 steel or min. 2,500 psi ACFoam II, ENRGY Note 2 0.5-inch Structodek High hot asphalt AA, SBS-AA, SBS- -45.0*
2.0 ft2 SBS-AA APP-TA
structrual concrete 3 or H-Shield Density Fiberboard Roof TA or APP-TA
Insulation, min. 0.75-inch
FescoBoard (homogeneous).
Optional min. 1.5-inch
Min. 22 ga., type B, Grade Min. 1.5-inch additional layer(s) base BP-AA, SBS- (Optional) BP-
1 per SBS-AA or
S-12 33 steel or min. 2,500 psi ACFoam II, ENRGY Note 2 insulation, followed by min. hot asphalt AA, SBS-TA AA, SBS-AA, SBS- -45.0*
2.0 ft2 APP-TA
structrual concrete 3 or H-Shield 0.25-inch DensDeck or or APP-TA TA or APP-TA
DensDeck Prime
Optional min. 1.5-inch
hot asphalt, M-
Min. 22 ga., type B, Grade Min. 1.5-inch additional layer(s) base BP-AA, SBS- (Optional) BP-
1 per OSFA, Insta Stik, SBS-AA or
S-13 33 steel or min. 2,500 psi ACFoam II, ENRGY Note 2 insulation, followed by min. AA, SBS-TA AA, SBS-AA, SBS- -45.0*
2.0 ft2 OB500, Polyset APP-TA
structrual concrete 3 or H-Shield 0.25-inch SECUROCK or APP-TA TA or APP-TA
BM, Polyset CRA
Gypsum-Fiber Roof Board
Optional min. 1.5-inch
additional layer(s) base
Min. 22 ga., type B, Grade Min. 2-inch insulation, followed by min. (Optional) BP-
1 per BP-AA or SBS-AA or
S-14 33 steel or min. 2,500 psi ACFoam II, ENRGY Note 2 0.5-inch Structodek High hot asphalt AA, SBS-AA, SBS- -45.0*
3.2 ft2 SBS-AA APP-TA
structrual concrete 3 or H-Shield Density Fiberboard Roof TA or APP-TA
Insulation, min. 0.75-inch
FescoBoard (homogeneous).
Optional min. 1.5-inch
Min. 22 ga., type B, Grade Min. 2-inch additional layer(s) base BP-AA, SBS- (Optional) BP-
1 per SBS-AA or
S-15 33 steel or min. 2,500 psi ACFoam II, ENRGY Note 2 insulation, followed by min. hot asphalt AA, SBS-TA AA, SBS-AA, SBS- -45.0*
3.2 ft2 APP-TA
structrual concrete 3 or H-Shield 0.25-inch DensDeck or or APP-TA TA or APP-TA
DensDeck Prime
Min. 1.5-inch
Min. 22 ga., type B, Grade (Optional) BP-
ACFoam II, ENRGY 1 per Min. 0.75-inch FescoBoard BP-AA or SBS-AA or
S-16 33 steel or min. 2,500 psi Note 2 hot asphalt AA, SBS-AA, SBS- -52.5
3 or Multi-Max 1.3 ft2 (homogeneous) SBS-AA APP-TA
structrual concrete TA or APP-TA
FA3

NEMO ETC, LLC 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Evaluation Report 3520.03.04-R30 for FL2533-R29
Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 30: 01/26/2023
©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 21 of 74
NEMO|etc.
TABLE 2A: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER
Base Insulation Layer Top Insulation Layer Roof Cover (Note 15)
System Deck MDP
No. (Note 1)
Attach (psf)
Type Fasten (Note 11) Attach Type Base Ply Ply Cap Ply
(Notes 6,7,8)
hot asphalt, M-
Min. 22 ga., type B, Grade Min. 2-inch BP-AA, SBS- (Optional) BP-
1 per Min. 0.25-inch SECUROCK OSFA, Insta Stik, SBS-AA or
S-17 33 steel or min. 2,500 psi ACFoam II, ENRGY Note 2 AA, SBS-TA AA, SBS-AA, SBS- -60.0
1.6 ft2 Gypsum-Fiber Roof Board OB500, Polyset APP-TA
structrual concrete 3 or H-Shield or APP-TA TA or APP-TA
BM, Polyset CRA
Min. 1.5-inch
Min. 22 ga., type B, Grade (Optional) BP-
ACFoam II, ENRGY 1 per Min. 0.5-inch Structodek High BP-AA or SBS-AA or
S-18 33 steel or min. 2,500 psi Note 2 hot asphalt AA, SBS-AA, SBS- -67.5
3 or Multi-Max 1.3 ft2 Density Fiberboard SBS-AA APP-TA
structrual concrete TA or APP-TA
FA3
Min. 22 ga., type B, Grade Min. 1.5-inch Trufast #12 DP (steel only) BP-AA, SBS- (Optional) BP-
1 per Min. 0.25-inch SECUROCK M-OSFA, M-PG1, SBS-AA or
S-19 40 steel or min. 2,500 psi ACFoam II or H- or #14 HD with Trufast 3” AA, SBS-TA AA, SBS-AA, SBS- -75.0
1.6 ft2 Gypsum-Fiber Roof Board Insta Stik, OB500 APP-TA
structrual concrete Shield Metal Insulation Plate or APP-TA TA or APP-TA
Min. 22 ga., type B, Grade Trufast #12 DP (steel only) BP-AA, SBS- (Optional) BP-
Min. 1.5-inch 1 per Min. 0.5-inch SECUROCK SBS-AA or
S-20 33 steel or min. 2,500 psi or #14 HD with Trufast 3” OB500, 4-inch o.c. AA, SBS-TA AA, SBS-AA, SBS- -90.0*
ENRGY 3 1.0 ft2 Gypsum-Fiber Roof Board APP-TA
structrual concrete Metal Insulation Plate or APP-TA TA or APP-TA
COLD-APPLIED SYSTEMS:
Min. 22 ga., type B, Grade Min. 2-inch Trufast #12 DP (steel only)
1 per Min. 1.5-inch ACFoam III or OB500 or Polyset
S-21 33 steel or min. 2,500 psi ACFoam II or H- or #14 HD with Trufast 3” SBS-CA1 None SBS-CA1 -45.0*
2.0 ft2 H-Shield CG CRA
structrual concrete Shield Metal Insulation Plate
Optional min. 1.5-inch
Insta Stik, M-
Min. 22 ga., type B, Grade Min. 2-inch Trufast #12 DP (steel only) additional layer(s) base
1 per OSFA, M-PG1,
S-22 33 steel or min. 2,500 psi ACFoam II or H- or #14 HD with Trufast 3” insulation, followed by min. SBS-CA1 None SBS-CA1 -45.0*
2.0 ft2 OB500, Polyset
structrual concrete Shield Metal Insulation Plate 0.25-inch SECUROCK
BM or Polyset CRA
Gypsum-Fiber Roof Board
Optional min. 1.5-inch
Insta Stik, M-
Min. 22 ga., type B, Grade Min. 2-inch Trufast #12 DP (steel only) additional layer(s) base
1 per OSFA, M-PG1,
S-23 33 steel or min. 2,500 psi ACFoam II or H- or #14 HD with Trufast 3” insulation, followed by min. SBS-CA4 None SBS-CA4 -45.0*
2.0 ft2 OB500, Polyset
structrual concrete Shield Metal Insulation Plate 0.25-inch SECUROCK
BM or Polyset CRA
Gypsum-Fiber Roof Board
Min. 22 ga., type B, Grade Min. 2-inch
1 per Min. 2-inch H-Shield HD
S-24 40 steel or min. 2,500 psi ACFoam II or H- Note 2 M-OSFA or M-PG1 SBS-CA4 None SBS-CA4 -45.0
2.7 ft2 Composite
structrual concrete Shield
Min. 22 ga., type B, Grade Min. 1.5-inch Trufast #12 DP (steel only)
1 per Min. 0.25-inch SECUROCK M-OSFA, M-PG1,
S-25 40 steel or min. 2,500 psi ACFoam II or H- or #14 HD with Trufast 3” SBS-CA1 None SBS-CA1 -75.0
1.6 ft2 Gypsum-Fiber Roof Board Insta Stik, OB500
structrual concrete Shield Metal Insulation Plate
Min. 22 ga., type B, Grade Trufast #12 DP (steel only)
Min. 1.5-inch 1 per Min. 0.5-inch SECUROCK
S-26 33 steel or min. 2,500 psi or #14 HD with Trufast 3” OB500, 4-inch o.c. SBS-CA1 None SBS-CA1 -90.0*
ENRGY 3 1.0 ft2 Gypsum-Fiber Roof Board
structrual concrete Metal Insulation Plate

NEMO ETC, LLC 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Evaluation Report 3520.03.04-R30 for FL2533-R29
Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 30: 01/26/2023
©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 22 of 74
NEMO|etc.
TABLE 2B: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER
System Deck Base Insulation Layer(s) Top Insulation Layer Roof Cover (Note 15) MDP
Primer
No. (Note 1) (Note 3, Note 13) Type Fasten (Note 11) Attach Base Ply Ply Cap Ply (psf)
SELF-ADHERING SYSTEMS:
Min. 22 ga., type B, Grade (Optional) One or more
Min. 0.25-inch SECUROCK 1 per (Optional) SBS-
S-27 33 steel or min. 2,500 psi layers, any Note 2 None SBS-SA SBS-SA -30.0*
Gypsum-Fiber Roof Board 3.2 ft2 SA
structrual concrete combination, loose laid
Min. 22 ga., type B, Grade (Optional) One or more Trufast #12 DP (steel only)
Min. 0.25-inch SECUROCK 1 per (Optional) SBS-
S-28 33 steel or min. 2,500 psi layers, any or #14 HD with Trufast 3” None SBS-SA SBS-SA -37.5*
Gypsum-Fiber Roof Board 2.7 ft2 SA
structrual concrete combination, loose laid Metal Insulation Plate
Min. 22 ga., type B, Grade (Optional) One or more
Min. 3/8-inch SECUROCK 1 per (Optional) SBS-
S-29 33 steel or min. 2,500 psi layers, any Note 2 None SBS-SA SBS-SA -45.0*
Gypsum-Fiber Roof Board 2.7 ft2 SA
structrual concrete combination, loose laid
Min. 22 ga., type B, Grade (Optional) One or more
1 per (Optional) SBS-
S-30 33 steel or min. 2,500 psi layers, any Min. 0.25-inch DensDeck Note 2 FlintPrime QD SBS-SA SBS-SA -45.0
1.3 ft2 SA
structrual concrete combination, loose laid
Min. 22 ga., type B, Grade (Optional) One or more Trufast #14 HD with
1 per (Optional) SBS-
S-31 40 steel or min. 2,500 psi layers, any Min. 1.5-inch ACFoam II Trufast 3” Metal Insulation FlintPrime QD SBS-SA SBS-SA -67.5
1.8 ft2 SA
structrual concrete combination, loose laid Plate
Min. 22 ga., type B, Grade (Optional) One or more Trufast #14 HD with
Min. 0.5-inch SECUROCK 1 per (Optional) SBS-
S-32 40 steel or min. 2,500 psi layers, any Trufast 3” Metal Insulation FlintPrime QD SBS-SA SBS-SA -82.5
Gypsum-Fiber Roof Board 1.6 ft2 SA
structrual concrete combination, loose laid Plate
Trufast #15 EHD (steel
Min. 22 ga., type B, Grade (Optional) One or more only) or Trufast #14 HD
Min. 1.5-inch ACFoam II or 1 per (Optional) SBS-
S-33 40 steel or min. 2,500 psi layers, any (concrete only) with FlintPrime QD SBS-SA SBS-SA -97.5
H-Shield 1.0 ft2 SA
structrual concrete combination, loose laid Trufast 3” Metal Insulation
Plate
HYBRID SYSTEMS:
Min. 22 ga., type B, Grade (Optional) One or more (Optional) BP-
Min. 0.25-inch DensDeck, 1 per SBS-SA- SBS-AA or
S-34 33 steel or min. 2,500 psi layers, any Note 2 None AA, SBS-AA, SBS- -30.0*
DensDeck Prime 2.0 ft2 H APP-TA
structrual concrete combination, loose laid TA or APP-TA
Min. 22 ga., type B, Grade (Optional) One or more Trufast #12 DP (steel only) (Optional) BP-
Min. 0.25-inch SECUROCK 1 per SBS-SA- SBS-AA or
S-35 33 steel or min. 2,500 psi layers, any or #14 HD with Trufast 3” None AA, SBS-AA, SBS- -37.5*
Gypsum-Fiber Roof Board 2.7 ft2 H APP-TA
structrual concrete combination, loose laid Metal Insulation Plate TA or APP-TA
Min. 22 ga., type B, Grade (Optional) One or more Trufast #12 DP (steel only) (Optional) BP-
Min. 3/8-inch SECUROCK 1 per SBS-SA- SBS-AA or
S-36 33 steel or min. 2,500 psi layers, any or #14 HD with Trufast 3” None AA, SBS-AA, SBS- -45.0*
Gypsum-Fiber Roof Board 2.7 ft2 H APP-TA
structrual concrete combination, loose laid Metal Insulation Plate TA or APP-TA
Min. 22 ga., type B, Grade (Optional) One or more Trufast #14 HD with
1 per SBS-SA- (Optional) SBS-
S-37 40 steel or min. 2,500 psi layers, any Min. 1.5-inch ACFoam II Trufast 3” Metal Insulation None APP-TA -67.5
1.8 ft2 H TA or APP-TA
structrual concrete combination, loose laid Plate

NEMO ETC, LLC 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Evaluation Report 3520.03.04-R30 for FL2533-R29
Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 30: 01/26/2023
©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 23 of 74
NEMO|etc.
TABLE 2B: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER
System Deck Base Insulation Layer(s) Top Insulation Layer Roof Cover (Note 15) MDP
Primer
No. (Note 1) (Note 3, Note 13) Type Fasten (Note 11) Attach Base Ply Ply Cap Ply (psf)
Trufast #12 DP (steel only)
Min. 22 ga., type B, Grade (Optional) One or more (Optional) SBS-
Min. 1.5-inch ACFoam II or or Trufast #14 HD with 1 per SBS-SA- SBS-AA or
S-38 33 steel or min. 2,500 psi layers, any None AA, SBS-TA or -75.0
H-Shield Trufast 3” Metal Insulation 1.45 ft2 H APP-TA
structrual concrete combination, loose laid APP-TA
Plate
Min. 22 ga., type B, Grade (Optional) One or more Trufast #14 HD with
Min. 0.5-inch SECUROCK 1 per SBS-SA- (Optional) SBS-
S-39 40 steel or min. 2,500 psi layers, any Trufast 3” Metal Insulation None APP-TA -82.5
Gypsum-Fiber Roof Board 1.6 ft2 H TA or APP-TA
structrual concrete combination, loose laid Plate
Min. 22 ga., type B, Grade (Optional) One or more Trufast #12 DP (steel only)
Min. 0.5-inch SECUROCK 1 per SBS-SA- (Optional) SBS-
S-40 33 steel or min. 2,500 psi layers, any or #14 HD with Trufast 3” None APP-TA -82.5
Gypsum-Fiber Roof Board 1.45 ft2 H TA or APP-TA
structrual concrete combination, loose laid Metal Insulation Plate
Min. 22 ga., type B, Grade (Optional) One or more (Optional) SBS-
Min. 1.5-inch ACFoam II, 1 per SBS-SA- SBS-AA or
S-41 33 steel or min. 2,500 psi layers, any Note 2 None AA, SBS-TA or -82.5
ENRGY 3 or Multi-Max FA3 1.3 ft2 H APP-TA
structrual concrete combination, loose laid APP-TA
Trufast #15 EHD (steel
Min. 22 ga., type B, Grade (Optional) One or more only) or Trufast #14 HD (Optional) SBS-
Min. 1.5-inch ACFoam II or 1 per SBS-SA- SBS-AA or
S-42 40 steel or min. 2,500 psi layers, any (concrete only) with None AA, SBS-TA or -97.5
H-Shield 1.0 ft2 H APP-TA
structrual concrete combination, loose laid Trufast 3” Metal Insulation APP-TA
Plate
Min. 22 ga., type B, Grade (Optional) One or more Trufast #12 DP (steel only)
Min. 0.5-inch SECUROCK 1 per SBS-SA- (Optional) SBS-
S-43 33 steel or min. 2,500 psi layers, any or #14 HD with Trufast 3” None APP-TA -135.0
Gypsum-Fiber Roof Board 1.0 ft2 H TA or APP-TA
structrual concrete combination, loose laid Metal Insulation Plate
CONVENTIONAL SYSTEMS:
Min. 22 ga., type B, Grade (Optional) One or more (Optional) BP-
Min. 0.75-inch FescoBoard 1 per BP-AA, SBS-AA or
S-44 33 steel or min. 2,500 psi layers, any Note 2 None AA, SBS-AA, SBS- -30.0*
(homogeneous) 2.7 ft2 SBS-AA APP-TA
structrual concrete combination, loose laid TA or APP-TA
Min. 22 ga., type B, Grade (Optional) One or more Min. 0.5-inch Structodek (Optional) BP-
1 per BP-AA, SBS-AA or
S-45 33 steel or min. 2,500 psi layers, any High Density Fiberboard Note 2 None AA, SBS-AA, SBS- -37.5*
4.0 ft2 SBS-AA APP-TA
structrual concrete combination, loose laid Roof Insulation TA or APP-TA
Min. 22 ga., type B, Grade (Optional) One or more (Optional) BP-
Min. 0.25-inch SECUROCK 1 per BP-AA, SBS-AA or
S-46 33 steel or min. 2,500 psi layers, any Note 2 None AA, SBS-AA, SBS- -37.5*
Gypsum-Fiber Roof Board 4.0 ft2 SBS-AA APP-TA
structrual concrete combination, loose laid TA or APP-TA
BP-AA,
Min. 22 ga., type B, Grade (Optional) One or more SBS-AA, (Optional) BP-
Min. 0.25-inch SECUROCK 1 per SBS-AA or
S-47 33 steel or min. 2,500 psi layers, any Note 2 None SBS-TA AA, SBS-AA, SBS- -45.0*
Gypsum-Fiber Roof Board 4.0 ft2 APP-TA
structrual concrete combination, loose laid or APP- TA or APP-TA
TA

NEMO ETC, LLC 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Evaluation Report 3520.03.04-R30 for FL2533-R29
Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 30: 01/26/2023
©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 24 of 74
NEMO|etc.
TABLE 2B: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER
System Deck Base Insulation Layer(s) Top Insulation Layer Roof Cover (Note 15) MDP
Primer
No. (Note 1) (Note 3, Note 13) Type Fasten (Note 11) Attach Base Ply Ply Cap Ply (psf)
Min. 0.5-inch Structodek
Min. 22 ga., type B, Grade (Optional) One or more High Density Fiberboard (Optional) BP-
1 per BP-AA or SBS-AA or
S-48 33 steel or min. 2,500 psi layers, any Roof Insulation, min. 0.75- Note 2 None AA, SBS-AA, SBS- -45.0*
2.0 ft2 SBS-AA APP-TA
structrual concrete combination, loose laid inch FescoBoard TA or APP-TA
(homogeneous)
BP-AA,
Min. 22 ga., type B, Grade (Optional) One or more SBS-AA, (Optional) BP-
Min. 0.25-inch DensDeck or 1 per SBS-AA or
S-49 33 steel or min. 2,500 psi layers, any Note 2 None SBS-TA AA, SBS-AA, SBS- -45.0*
DensDeck Prime 2.0 ft2 APP-TA
structrual concrete combination, loose laid or APP- TA or APP-TA
TA
Trufast #12 DP (steel only)
Min. 22 ga., type B, Grade Min. 1.5-inch, One or
Min. 0.25-inch SECUROCK or Trufast #14 HD with 1 per (Optional) APP-
S-50 33 steel or min. 2,500 psi more layers, any None APP-TA APP-TA -60.0
Gypsum-Fiber Roof Board Trufast 3” Metal Insulation 1.45 ft2 TA
structrual concrete combination, loose laid
Plate
BP-AA,
Min. 22 ga., type B, Grade Min. 2-inch ACFoam II, SBS-AA, (Optional) BP-
Min. 0.5-inch SECUROCK 1 per SBS-AA or
S-51 33 steel or min. 2,500 psi ENRGY 3 or H-Shield, Note 2 None SBS-TA AA, SBS-AA, SBS- -60.0
Gypsum-Fiber Roof Board 1.8 ft2 APP-TA
structrual concrete loose laid. or APP- TA or APP-TA
TA
BP-AA,
Min. 22 ga., type B, Grade (Optional) One or more Trufast #12 DP (steel only) SBS-AA, (Optional) BP-
Min. 0.5-inch SECUROCK 1 per SBS-AA or
S-52 33 steel or min. 2,500 psi layers, any or #14 HD with Trufast 3” None SBS-TA AA, SBS-AA, SBS- -82.5
Gypsum-Fiber Roof Board 1.45 ft2 APP-TA
structrual concrete combination, loose laid Metal Insulation Plate or APP- TA or APP-TA
TA
Min. 22 ga., type B, Grade Trufast #14 HD with
Min. 1.5-inch ACFoam II Min. 0.5-inch DensDeck 1 per BP-AA, (Optional) BP-
S-53 33 steel or min. 2,500 psi Trufast 3” Metal Insulation None SBS-AA -112.5
or H-Shield Prime 1.3 ft2 SBS-AA AA, SBS-AA
structrual concrete Plate
BP-AA,
Min. 22 ga., type B, Grade (Optional) One or more Trufast #12 DP (steel only) SBS-AA, (Optional) BP-
Min. 0.5-inch SECUROCK 1 per SBS-AA or
S-54 33 steel or min. 2,500 psi layers, any or #14 HD with Trufast 3” None SBS-TA AA, SBS-AA, SBS- -135.0
Gypsum-Fiber Roof Board 1.0 ft2 APP-TA
structrual concrete combination, loose laid Metal Insulation Plate or APP- TA or APP-TA
TA
Min. 22 ga., type B, Grade Trufast #14 HD with
Min. 1.5-inch ACFoam II Min. 0.5-inch SECUROCK 1 per BP-AA, (Optional) BP-
S-55 33 steel or min. 2,500 psi Trufast 3” Metal Insulation None SBS-AA -157.5
or H-Shield Gypsum-Fiber Roof Board 1.3 ft2 SBS-AA AA, SBS-AA
structrual concrete Plate
Min. 22 ga., type B, Grade Trufast #14 HD with
Min. 1.5-inch ACFoam II Min. 0.5-inch DensDeck 1 per BP-AA, (Optional) BP-
S-56 33 steel or min. 2,500 psi Trufast 3” Metal Insulation None SBS-AA -157.5
or H-Shield Prime 1.0 ft2 SBS-AA AA, SBS-AA
structrual concrete Plate

NEMO ETC, LLC 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Evaluation Report 3520.03.04-R30 for FL2533-R29
Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 30: 01/26/2023
©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 25 of 74
NEMO|etc.
TABLE 2B: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER
System Deck Base Insulation Layer(s) Top Insulation Layer Roof Cover (Note 15) MDP
Primer
No. (Note 1) (Note 3, Note 13) Type Fasten (Note 11) Attach Base Ply Ply Cap Ply (psf)
Min. 22 ga., type B, Grade Trufast #14 HD with
Min. 1.5-inch ACFoam II Min. 0.5-inch SECUROCK 1 per BP-AA, (Optional) BP-
S-57 33 steel or min. 2,500 psi Trufast 3” Metal Insulation None SBS-AA -172.5
or H-Shield Gypsum-Fiber Roof Board 1.0 ft2 SBS-AA AA, SBS-AA
structrual concrete Plate
SPOT- OR STRIP-MOPPED SYSTEMS:
Min. 22 ga., type B, Grade (Optional) One or more (Optional) BP-
Min. 2-inch ACFoam II or 1 per SBS-AA or
S-58 33 steel or min. 2,500 psi layers, any Note 2 None BP-AA2 AA, SBS-AA, SBS- -37.5*
ENRGY 3 1.6 ft2 APP-TA
structrual concrete combination, loose laid TA or APP-TA
Min. 22 ga., type B, Grade (Optional) One or more Min. 1-inch FescoBoard (Optional) BP-
1 per SBS-AA or
S-59 33 steel or min. 2,500 psi layers, any (homogeneous) or min. 1.5- Note 2 None BP-AA2 AA, SBS-AA, SBS- -45.0*
1.6 ft2 APP-TA
structrual concrete combination, loose laid inch FescoBoard (laminated) TA or APP-TA
Min. 22 ga., type B, Grade (Optional) One or more (Optional) BP-
Min. 0.5-inch Structodek HD 1 per SBS-AA or
S-60 33 steel or min. 2,500 psi layers, any Note 2 None BP-AA2 AA, SBS-AA, SBS- -45.0*
with Primed Red Coating 2.0 ft2 APP-TA
structrual concrete combination, loose laid TA or APP-TA
Min. 22 ga., type B, Grade (Optional) One or more BP-AA3,
1 per (Optional) BP-AA
S-61 33 steel or min. 2,500 psi layers, any Min. 1.5-inch ACFoam II Note 2 None 24-inch SBS-AA -52.5
1.45 ft2 or SBS-AA
structrual concrete combination, loose laid grid
Min. 22 ga., type B, Grade (Optional) One or more BP-AA3,
1 per
S-62 33 steel or min. 2,500 psi layers, any Min. 1.5-inch ACFoam II Note 2 None 24-inch BP-AA or SBS-AA SBS-TA -52.5
1.45 ft2
structrual concrete combination, loose laid grid
COLD-APPLIED SYSTEMS:
Min. 22 ga., type B, Grade (Optional) One or more Trufast #12 DP (steel only)
Min. 0.25-inch SECUROCK 1 per
S-63 33 steel or min. 2,500 psi layers, any or #14 HD with Trufast 3” None SBS-CA1 None SBS-CA1 -37.5*
Gypsum-Fiber Roof Board 2.7 ft2
structrual concrete combination, loose laid Metal Insulation Plate
Min. 22 ga., type B, Grade (Optional) One or more Trufast #12 DP (steel only)
Min. 0.25-inch SECUROCK 1 per
S-64 33 steel or min. 2,500 psi layers, any or #14 HD with Trufast 3” None SBS-CA4 None SBS-CA4 -37.5*
Gypsum-Fiber Roof Board 2.7 ft2
structrual concrete combination, loose laid Metal Insulation Plate
Min. 22 ga., type B, Grade (Optional) One or more Trufast #12 DP (steel only)
Min. 1.5-inch ACFoam III or 1 per
S-65 33 steel or min. 2,500 psi layers, any or #14 HD with Trufast 3” None SBS-CA1 None SBS-CA1 -45.0*
H-Shield CG 2.0 ft2
structrual concrete combination, loose laid Metal Insulation Plate
Min. 22 ga., type B, Grade (Optional) One or more Trufast #12 DP (steel only)
Min. 3/8-inch SECUROCK 1 per
S-66 33 steel or min. 2,500 psi layers, any or #14 HD with Trufast 3” None SBS-CA1 None SBS-CA1 -45.0*
Gypsum-Fiber Roof Board 2.7 ft2
structrual concrete combination, loose laid Metal Insulation Plate
Min. 22 ga., type B, Grade (Optional) One or more Trufast #12 DP (steel only)
Min. 3/8-inch SECUROCK 1 per
S-67 33 steel or min. 2,500 psi layers, any or #14 HD with Trufast 3” None SBS-CA4 None SBS-CA4 -45.0*
Gypsum-Fiber Roof Board 2.7 ft2
structrual concrete combination, loose laid Metal Insulation Plate
Min. 22 ga., type B, Grade (Optional) One or more Trufast #12 DP (steel only)
Min. 0.5-inch SECUROCK 1 per
S-68 33 steel or min. 2,500 psi layers, any or #14 HD with Trufast 3” None SBS-CA1 None SBS-CA1 -82.5*
Gypsum-Fiber Roof Board 1.45 ft2
structrual concrete combination, loose laid Metal Insulation Plate

NEMO ETC, LLC 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Evaluation Report 3520.03.04-R30 for FL2533-R29
Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 30: 01/26/2023
©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 26 of 74
NEMO|etc.
TABLE 2C: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE D-2: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
Insulation Layer(s)
System Deck Base Sheet Roof Cover (Note 15) MDP
(Note 3, Note 13)
No. (Note 1) (psf)
Type Attach Type Fasten (Note 11) Attach Base Ply Cap Ply
SELF-ADHERING SYSTEMS:
Min. 22 ga., type B, Grade Min. 1.5-inch, One 9-inch o.c. at min. 2-inch lap and
Prelim. (Optional) SBS-
S-69 33 steel or min. 2,500 psi or more layers, any Flintlastic SA NailBase Note 2 18-inch o.c. in two (2), equally SBS-SA -45.0*
Attached SA
structrual concrete combination spaced, staggered center rows
Min. 22 ga., type B, Grade Min. 1.5-inch, One 12-inch o.c. at min. 2-inch lap and
Prelim. (Optional) SBS-
S-70 33 steel or min. 2,500 psi or more layers, any Flintlastic SA NailBase Note 2 12-inch o.c. in two (2), equally SBS-SA -52.5*
Attached SA
structrual concrete combination spaced, staggered center rows
Min. 22 ga., type B, Grade Min. 1.5-inch, One 12-inch o.c. at min. 4-inch lap and
Prelim. (Optional) SBS-
S-71 33 steel or min. 2,500 psi or more layers, any Flintlastic SA NailBase Note 2 12-inch o.c. in two (2), equally SBS-SA -60.0*
Attached SA
structrual concrete combination spaced, staggered center rows
8-inch o.c. at min. 4-inch lap and 8-
Min. 22 ga., type B, Grade Min. 1.5-inch, One
Prelim. Flintlastic SA NailBase (laid inch o.c. in two (2), equally spaced, (Optional) SBS-
S-72 33 steel or min. 2,500 psi or more layers, any Note 2 SBS-SA -82.5*
Attached parallel to deck flutes) staggered center rows, FlintPrime SA
structrual concrete combination
QD at stress plates
CONVENTIONAL SYSTEMS:
Glasbase Base Sheet, All
Min. 22 ga., type B, Grade Min. 1.5-inch, One 12-inch o.c. at 4-inch lap and 36- BP-AA, SBS-AA,
Prelim. Weather/Empire Base SBS-AA or
S-73 33 steel or min. 2,500 psi or more layers, any Note 2 inch o.c. in two (2), equally spaced, SBS-TA or APP- -30.0*
Attached Sheet, Flintlastic Base 20 or APP-TA
structrual concrete combination staggered center rows TA
Flintglas MS Cap (inverted)
Glasbase Base Sheet, All
Min. 22 ga., type B, Grade Min. 1.5-inch, One 12-inch o.c. at 4-inch lap and 24- BP-AA, SBS-AA,
Prelim. Weather/Empire Base SBS-AA or
S-74 33 steel or min. 2,500 psi or more layers, any Note 2 inch o.c. in two (2), equally spaced, SBS-TA or APP- -45.0*
Attached Sheet, Flintlastic Base 20 or APP-TA
structrual concrete combination staggered center rows TA
Flintglas MS Cap (inverted)
Min. 22 ga., type B, Grade Min. 1.5-inch, One Flintlastic Poly SMS Base 12-inch o.c. at 4-inch lap and 36- BP-AA, SBS-AA,
Prelim. SBS-AA or
S-75 33 steel or min. 2,500 psi or more layers, any Sheet, Flintlastic Ultra Poly Note 2 inch o.c. in two (2), equally spaced, SBS-TA or APP- -45.0*
Attached APP-TA
structrual concrete combination SMS Base Sheet staggered center rows TA
Min. 22 ga., type B, Grade Min. 1.5-inch, One Flintlastic Poly SMS Base 18-inch o.c. at 4-inch lap and 18- BP-AA, SBS-AA,
Prelim. SBS-AA or
S-76 33 steel or min. 2,500 psi or more layers, any Sheet, Flintlastic Ultra Poly Note 2 inch o.c. in one (1) staggered SBS-TA or APP- -45.0*
Attached APP-TA
structrual concrete combination SMS Base Sheet center row TA
Min. 22 ga., type B, Grade Min. 1.5-inch, One Flintlastic Poly SMS Base
Prelim. Dekfast DF-#14-PH3 12-inch o.c. within the min. 4-inch SBS-AA, SBS-TA SBS-AA or
S-77 33 steel or min. 2,500 psi or more layers, any Sheet, Flintlastic Ultra Poly -45.0*
Attached with PLT-R-2-4B wide, heat-welded side lap or APP-TA APP-TA
structrual concrete combination SMS Base Sheet

NEMO ETC, LLC 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Evaluation Report 3520.03.04-R30 for FL2533-R29
Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 30: 01/26/2023
©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 27 of 74
NEMO|etc.
TABLE 2C: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE D-2: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
Insulation Layer(s)
System Deck Base Sheet Roof Cover (Note 15) MDP
(Note 3, Note 13)
No. (Note 1) (psf)
Type Attach Type Fasten (Note 11) Attach Base Ply Cap Ply
Glasbase Base Sheet,
Flintlastic Base 20, All
Min. 22 ga., type B, Grade Min. 1.5-inch, One 12-inch o.c. at 3-inch lap and 12- BP-AA, SBS-AA,
Prelim. Weather/Empire Base SBS-AA or
S-78 33 steel or min. 2,500 psi or more layers, any Note 2 inch o.c. in two (2), equally spaced, SBS-TA or APP- -52.5
Attached Sheet, Flintlastic Poly SMS APP-TA
structrual concrete combination staggered center rows TA
Base Sheet or Flintglas MS
Cap (inverted)
Trufast #15 EHD (steel
Min. 22 ga., type B, 40 ksi Min. 2-inch, One or only) or Trufast #14 HD
Prelim. Flintlastic Ultra Poly SMS 12-inch o.c. within the min. 4-inch (Optional) SBS-
S-79 steel or min. 2,500 psi more layers, any (concrete only) with APP-TA -52.5
Attached Base Sheet wide, heat-welded side lap TA or APP-TA
structrual concrete combination Trufast 2” Barbed Metal
Seam Plate
Trufast #15 EHD (steel
Min. 22 ga., type B, Grade Min. 1.5-inch, One only) or Trufast #14 HD
Prelim. Flintlastic Ultra Poly SMS 12-inch o.c. within the min. 4-inch (Optional) SBS-
S-80 80 steel or min. 2,500 psi or more layers, any (concrete only) with APP-TA -60.0
Attached Base Sheet wide, heat-welded side lap TA or APP-TA
structrual concrete combination Trufast 2.4” Barbed
Metal Seam Plate
Trufast #15 EHD (steel
Min. 22 ga., type B, 40 ksi Min. 2-inch, One or only) or Trufast #14 HD
Prelim. Flintlastic Ultra Poly SMS 12-inch o.c. within the min. 4-inch (Optional) SBS-
S-81 steel or min. 2,500 psi more layers, any (concrete only) with APP-TA -67.5
Attached Base Sheet wide, heat-welded side lap TA or APP-TA
structrual concrete combination Trufast 2.4” Scoop Seam
Plate
Min. 22 ga., type B, Grade Min. 1.5-inch, One OMG #14 HD with OMG 6-inch o.c. at 4-inch lap and 6-inch BP-AA, SBS-AA,
Prelim. Glasbase Base Sheet or SBS-AA or
S-82 33 steel or min. 2,500 psi or more layers, any Flat Bottom Plates o.c. in two (2), equally spaced, SBS-TA or APP- -67.5
Attached Flintglas MS Cap (inverted) APP-TA
structrual concrete combination (AccuTrac) staggered center rows TA
Min. 22 ga., type B, Grade Min. 1.5-inch, One 6-inch o.c. at 4-inch lap and 6-inch BP-AA, SBS-AA,
Prelim. Flintlastic Base 20 or SBS-AA or
S-83 33 steel or min. 2,500 psi or more layers, any Note 2 o.c. in two (2), equally spaced, SBS-TA or APP- -67.5
Attached Flintglas MS Cap (inverted) APP-TA
structrual concrete combination staggered center rows TA
Glasbase Base Sheet,
Flintlastic Base 20, All
Min. 22 ga., type B, Grade Min. 1.5-inch, One Weather/Empire Base Trufast #14 HD with 6-inch o.c. at 4-inch lap and 6-inch (Optional) BP-
Prelim.
S-84 33 steel or min. 2,500 psi or more layers, any Sheet, Flintlastic Poly SMS Trufast 3” Metal o.c. at three (3) equally spaced, AA, SBS-AA or SBS-AA -97.5
Attach
structrual concrete combination Base Sheet, Flintlastic Ultra Insulation Plate staggered center rows SBS-TA
Poly SMS Base Sheet or
Flintglas MS Cap (inverted)
Trufast #15 EHD (steel
Min. 22 ga., type B, 40 ksi Min. 2-inch, One or only) or Trufast #14 HD
Prelim. Flintlastic Ultra Poly SMS 6-inch o.c. within the min. 4-inch (Optional) SBS-
S-85 steel or min. 2,500 psi more layers, any (concrete only) with APP-TA -112.5
Attached Base Sheet wide, heat-welded side lap TA or APP-TA
structrual concrete combination Trufast 2.4” Scoop Seam
Plate
NEMO ETC, LLC 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Evaluation Report 3520.03.04-R30 for FL2533-R29
Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 30: 01/26/2023
©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 28 of 74
NEMO|etc.
TABLE 2C: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE D-2: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
Insulation Layer(s)
System Deck Base Sheet Roof Cover (Note 15) MDP
(Note 3, Note 13)
No. (Note 1) (psf)
Type Attach Type Fasten (Note 11) Attach Base Ply Cap Ply
Min. 22 ga., type B, Grade Min. 1.5-inch, One Flintlastic Poly SMS Base 12-inch o.c. at 4-inch lap and 12-
Prelim. SBS-TA or APP-
S-86 80 steel or min. 2,500 psi or more layers, any Sheet, Flintlastic Ultra Poly Note 2 inch o.c. in two (2), equally spaced, APP-TA -112.5
Attached TA
structrual concrete combination SMS Base Sheet staggered center rows
Min. 22 ga., type B, Grade Min. 1.5-inch, One Flintlastic Poly SMS Base 12-inch o.c. at 4-inch lap and 12-
Prelim.
S-87 80 steel or min. 2,500 psi or more layers, any Sheet, Flintlastic Ultra Poly Note 2 inch o.c. in two (2), equally spaced, SBS-AA SBS-AA -120.0
Attached
structrual concrete combination SMS Base Sheet staggered center rows
6-inch o.c. within the min. 4-inch
Trufast #15 EHD (steel wide, heat-welded side laps and 6-
Min. 22 ga., type B, 40 ksi Min. 2-inch, One or only) or Trufast #14 HD inch o.c. in one (1) center row,
Prelim. Flintlastic Ultra Poly SMS (Optional) SBS-
S-88 steel or min. 2,500 psi more layers, any (concrete only) with stripped-in with 6-inch side strips APP-TA -165.0
Attached Base Sheet TA or APP-TA
structrual concrete combination Trufast 2.4” Scoop Seam of torch-applied Flintlastic Poly
Plate SMS Base Sheet or Flintlastic Ultra
Poly SMS Base Sheet.
COLD-APPLIED SYSTEMS:
Min. 22 ga., type B, Grade Min. 1.5-inch, One Glasbase Base Sheet, All 6-inch o.c. at 4-inch lap and 12-
Prelim.
S-89 33 steel or min. 2,500 psi or more layers, any Weather/Empire Base Note 2 inch o.c. in two (2), equally spaced, SBS-CA1 SBS-CA1 -45.0*
Attached
structrual concrete combination Sheet, Flintlastic Base 20 staggered center rows
Glasbase Base Sheet,
Flintlastic Base 20, All
Min. 22 ga., type B, Grade Min. 1-inch, One or Trufast #14 HD with 6-inch o.c. at 4-inch lap and 12-
Weather/Empire Base (Optional) SBS-
S-90 40 steel or min. 2,500 psi more layers, any Loose-laid Trufast 3” Metal inch o.c. in three (3), equally SBS-CA1 -75.0
Sheet, Flintlastic Poly SMS CA1
structrual concrete combination Insulation Plate spaced, staggered center rows
Base Sheet, Flintlastic Ultra
Poly SMS Base Sheet

NEMO ETC, LLC 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Evaluation Report 3520.03.04-R30 for FL2533-R29
Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 30: 01/26/2023
©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 29 of 74
NEMO|etc.
TABLE 3A: STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
REFER TO NOTE 16 FOR VAPOR BARRIER OPTIONS
Base Insulation Layer Top Insulation Layer Roof Cover (Note 15)
Sys. Deck MDP
Primer Attach Attach Primer
No. (Note 1) Type Type Base Ply Ply Cap Ply (psf)
(Notes 6,7,8) (Notes 6,7,8)
SELF-ADHERING SYSTEMS:
Structural FlintPrime Min. 1.5-inch ACFoam II, ENRGY Min. 0.25-inch SECUROCK (Optional) SBS-
C-1. hot asphalt hot asphalt None SBS-SA SBS-SA -172.5
concrete QD 3 or H-Shield Gypsum-Fiber Roof Board SA
Structural FlintPrime Min. 1.5-inch ACFoam II, ENRGY FlintPrime (Optional) SBS-
C-2. hot asphalt Min. 0.25-inch DensDeck hot asphalt SBS-SA SBS-SA -192.5
concrete QD 3 or Multi-Max FA3 QD SA
Structural (Optional) Min. 1.5-inch M-OSFA or M- Min. 0.5-inch ACFoam-HD M-OSFA or M- FlintPrime (Optional) SBS-
C-3. None SBS-SA SBS-SA -97.5
concrete ACFoam II or H-Shield PG1 CoverBoard or H-Shield HD PG1 QD SA
Structural (Optional) Min. 1.5-inch M-OSFA or M- Min. 2-inch H-Shield HD M-OSFA or M- (Optional) SBS-
C-4. None None SBS-SA SBS-SA -142.5
concrete ACFoam II or H-Shield PG1 Composite CG PG1 SA
Structural Min. 1.5-inch ACFoam II, ENRGY M-OSFA or M- Min. 0.25-inch SECUROCK M-OSFA or M- (Optional) SBS-
C-5. None None SBS-SA SBS-SA -172.5
concrete 3 or H-Shield PG1 Gypsum-Fiber Roof Board PG1 SA
Structural Min. 1.5-inch ACFoam II, ENRGY M-OSFA or M- M-OSFA or M- FlintPrime (Optional) SBS-
C-6. None Min. 0.25-inch DensDeck SBS-SA SBS-SA -192.5
concrete 3 or Multi-Max FA3 PG1 PG1 QD SA
Structural (Optional) Min. 1.5-inch M-OSFA or M- Min. 0.25-inch SECUROCK M-OSFA or M- FlintPrime (Optional) SBS-
C-7. None SBS-SA SBS-SA -315.0
concrete ACFoam II or H-Shield PG1, 6-inch o.c. Gypsum-Fiber Roof Board PG1, 6-inch o.c. QD SA
Structural (Optional) Min. 1.5-inch M-OSFA or M- Min. 0.5-inch ACFoam-HD M-OSFA or M- FlintPrime (Optional) SBS-
C-8. None SBS-SA SBS-SA -315.0
concrete ACFoam II or H-Shield PG1, 6-inch o.c. CoverBoard or H-Shield HD PG1, 6-inch o.c. QD SA
Structural (Optional) Min. 1.5-inch M-OSFA or M- Min. 2-inch H-Shield HD M-OSFA or M- (Optional) SBS-
C-9. None None SBS-SA SBS-SA -342.5
concrete ACFoam II or H-Shield PG1, 6-inch o.c. Composite CG PG1, 6-inch o.c. SA
Structural (Optional) Min. 1.5-inch FlintPrime (Optional) SBS-
C-10. None M-PG1-EF-ECO Min. 0.5-inch H-Shield HD M-PG1-EF-ECO SBS-SA SBS-SA -97.5
concrete ACFoam II or H-Shield QD SA
Structural (Optional) Min. 1.5-inch Min. 2-inch H-Shield HD (Optional) SBS-
C-11. None M-PG1-EF-ECO M-PG1-EF-ECO None SBS-SA SBS-SA -142.5
concrete ACFoam II or H-Shield Composite CG SA
Structural Min. 1.5-inch ACFoam II, ENRGY Min. 0.25-inch SECUROCK (Optional) SBS-
C-12. None M-PG1-EF-ECO M-PG1-EF-ECO None SBS-SA SBS-SA -172.5
concrete 3 or H-Shield Gypsum-Fiber Roof Board SA
(Optional)
Structural FlintPrime (Optional) SBS-
C-13. FlintPrime Min. 1.5-inch Multi-Max FA Insta Stik Min. 0.25-inch DensDeck Insta Stik SBS-SA SBS-SA -67.5
concrete QD SA
QD
(Optional)
Structural FlintPrime (Optional) SBS-
C-14. FlintPrime Min. 1.5-inch ENRGY 3 Insta Stik Min. 0.25-inch DensDeck Insta Stik SBS-SA SBS-SA -112.5
concrete QD SA
QD
(Optional)
Structural FlintPrime (Optional) SBS-
C-15. FlintPrime Min. 1.5-inch ACFoam II Insta Stik Min. 0.25-inch DensDeck Insta Stik SBS-SA SBS-SA -120.0
concrete QD SA
QD

NEMO ETC, LLC 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Evaluation Report 3520.03.04-R30 for FL2533-R29
Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 30: 01/26/2023
©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 30 of 74
NEMO|etc.
TABLE 3A: STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
REFER TO NOTE 16 FOR VAPOR BARRIER OPTIONS
Base Insulation Layer Top Insulation Layer Roof Cover (Note 15)
Sys. Deck MDP
Primer Attach Attach Primer
No. (Note 1) Type Type Base Ply Ply Cap Ply (psf)
(Notes 6,7,8) (Notes 6,7,8)
Structural Min. 1.5-inch ACFoam II, ENRGY Min. 0.25-inch SECUROCK (Optional) SBS-
C-16. None Insta Stik Insta Stik None SBS-SA SBS-SA -172.5
concrete 3 or H-Shield Gypsum-Fiber Roof Board SA
Structural FlintPrime Min. 1.5-inch ACFoam II or FlintPrime (Optional) SBS-
C-17. OB500 Min. 0.25-inch DensDeck OB500 SBS-SA SBS-SA -120.0
concrete QD ENRGY 3 QD SA
Structural Min. 1.5-inch ACFoam II or FlintPrime (Optional) SBS-
C-18. None OB500 Min. 0.25-inch DensDeck OB500 SBS-SA SBS-SA -150.0
concrete ENRGY 3 QD SA
Structural Min. 1.5-inch ACFoam II, ENRGY Min. 0.25-inch SECUROCK (Optional) SBS-
C-19. None OB500 OB500 None SBS-SA SBS-SA -172.5
concrete 3 or H-Shield Gypsum-Fiber Roof Board SA
Min. 1-inch ENRGY 3, H-Shield
Structural Polyset BM or Min. 0.25-inch SECUROCK Polyset BM or (Optional) SBS-
C-20. None or H-Shield CG or min. 1.5-inch None SBS-SA SBS-SA -172.5
concrete Polyset CRA Gypsum-Fiber Roof Board Polyset CRA SA
Multi-Max FA3 or Ultra-Max
Min. 1-inch ENRGY 3, H-Shield
Structural Polyset BM or Polyset BM or FlintPrime (Optional) SBS-
C-21. None or H-Shield CG or min. 1.5-inch Min. 0.25-inch DensDeck SBS-SA SBS-SA -192.5
concrete Polyset CRA Polyset CRA QD SA
Multi-Max FA3 or Ultra-Max
HYBRID SYSTEMS:
(Optional) SBS-
Structural FlintPrime Min. 1.5-inch ACFoam II or H- (Optional) Additional Flintlastic Ultra SBS-AA,
C-22. hot asphalt hot asphalt None AA, SBS-TA, APP- -322.5
concrete QD Shield layer(s) base insulation Glass SA APP-TA
TA
(Optional) SBS-
Structural FlintPrime Min. 1.5-inch ACFoam II or H- (Optional) Additional Black Diamond SBS-AA,
C-23. hot asphalt hot asphalt None AA, SBS-TA, APP- -375.0
concrete QD Shield layer(s) base insulation Base Sheet APP-TA
TA
(Optional) SBS-
Structural (Optional) Min. 1.5-inch M-OSFA or M- Min. 0.5-inch ACFoam-HD M-OSFA or M- SBS-AA,
C-24. None None SBS-SA-H AA, SBS-TA, APP- -97.5
concrete ACFoam II or H-Shield PG1 CoverBoard or H-Shield HD PG1 APP-TA
TA
(Optional) SBS-
Structural (Optional) Min. 1.5-inch M-OSFA or M- Min. 2-inch H-Shield HD M-OSFA or M- SBS-AA,
C-25. None None SBS-SA-H AA, SBS-TA, APP- -142.5
concrete ACFoam II or H-Shield PG1 Composite CG PG1 APP-TA
TA
(Optional) SBS-
Structural Min. 1.5-inch ACFoam II or H- (Optional) Additional SBS-AA,
C-26. None M-OSFA M-OSFA None SBS-SA-H AA, SBS-TA, APP- -232.5
concrete Shield layer(s) base insulation APP-TA
TA
(Optional) SBS-
Structural Min. 1.5-inch ACFoam II or H- Min. 0.25-inch SECUROCK SBS-AA,
C-27. None M-OSFA M-OSFA None SBS-SA-H AA, SBS-TA, APP- -217.5
concrete Shield Gypsum-Fiber Roof Board APP-TA
TA
(Optional) SBS-
Structural Min. 1-inch Styrofoam Brand M-OSFA or M- Min. 0.25-inch SECUROCK M-OSFA or M- SBS-AA,
C-28. None None SBS-SA-H AA, SBS-TA, APP- -210.0
concrete Roofmate PG1 Gypsum-Fiber Roof Board PG1 APP-TA
TA
NEMO ETC, LLC 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Evaluation Report 3520.03.04-R30 for FL2533-R29
Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 30: 01/26/2023
©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 31 of 74
NEMO|etc.
TABLE 3A: STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
REFER TO NOTE 16 FOR VAPOR BARRIER OPTIONS
Base Insulation Layer Top Insulation Layer Roof Cover (Note 15)
Sys. Deck MDP
Primer Attach Attach Primer
No. (Note 1) Type Type Base Ply Ply Cap Ply (psf)
(Notes 6,7,8) (Notes 6,7,8)
(Optional) SBS-
Structural Min. 0.25-inch SECUROCK SBS-AA,
C-29. None M-OSFA None N/A None SBS-SA-H AA, SBS-TA, APP- -195.0
concrete Gypsum-Fiber Roof Board APP-TA
TA
(Optional) SBS-
Structural Min. 1.5-inch ACFoam II or H- (Optional) Additional SBS-AA,
C-30. None M-PG1 M-PG1 None SBS-SA-H AA, SBS-TA, APP- -270.0
concrete Shield layer(s) base insulation APP-TA
TA
(Optional) SBS-
Structural Min. 1.5-inch ACFoam II or H- Min. 0.25-inch SECUROCK SBS-AA,
C-31. None M-PG1 M-PG1 None SBS-SA-H AA, SBS-TA, APP- -217.5
concrete Shield Gypsum-Fiber Roof Board APP-TA
TA
(Optional) SBS-
Structural Min. 0.25-inch SECUROCK SBS-AA,
C-32. None M-PG1 None N/A None SBS-SA-H AA, SBS-TA, APP- -195.0
concrete Gypsum-Fiber Roof Board APP-TA
TA
Min. 0.25-inch DensDeck
Prime or SECUROCK
(Optional) SBS-
Structural (Optional) Min. 1.5-inch M-OSFA or M- Gypsum-Fiber Roof Board M-OSFA or M- SBS-AA,
C-33. None None SBS-SA-H AA, SBS-TA, APP- -315.0
concrete ACFoam II or H-Shield PG1, 6-inch o.c. or min. 0.5-inch ACFoam- PG1, 6-inch o.c. APP-TA
TA
HD CoverBoard or H-Shield
HD
(Optional) SBS-
Structural (Optional) Min. 1.5-inch M-OSFA or M- Min. 2-inch H-Shield HD M-OSFA or M- SBS-AA,
C-34. None None SBS-SA-H AA, SBS-TA, APP- -342.5
concrete ACFoam II or H-Shield PG1, 6-inch o.c. Composite CG PG1, 6-inch o.c. APP-TA
TA
(Optional) SBS-
Structural (Optional) Min. 1.5-inch SBS-AA,
C-35. None M-PG1-EF-ECO Min. 0.5-inch H-Shield HD M-PG1-EF-ECO None SBS-SA-H AA, SBS-TA, APP- -97.5
concrete ACFoam II or H-Shield APP-TA
TA
(Optional) SBS-
Structural (Optional) Min. 1.5-inch Min. 2-inch H-Shield HD SBS-AA,
C-36. None M-PG1-EF-ECO M-PG1-EF-ECO None SBS-SA-H AA, SBS-TA, APP- -142.5
concrete ACFoam II or H-Shield Composite CG APP-TA
TA
(Optional) SBS-
Structural Min. 0.25-inch SECUROCK SBS-AA,
C-37. None M-PG1-EF-ECO None N/A None SBS-SA-H AA, SBS-TA, APP- -195.0
concrete Gypsum-Fiber Roof Board APP-TA
TA
(Optional) SBS-
Structural Min. 1.5-inch ACFoam II or H- Min. 0.25-inch SECUROCK SBS-AA,
C-38. None M-PG1-EF-ECO M-PG1-EF-ECO None SBS-SA-H AA, SBS-TA, APP- -217.5
concrete Shield Gypsum-Fiber Roof Board APP-TA
TA
(Optional) SBS-
Structural Min. 1.5-inch ACFoam II or H- (Optional) Additional SBS-AA,
C-39. None M-PG1-EF-ECO M-PG1-EF-ECO None SBS-SA-H AA, SBS-TA, APP- -247.5
concrete Shield layer(s) base insulation APP-TA
TA

NEMO ETC, LLC 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Evaluation Report 3520.03.04-R30 for FL2533-R29
Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 30: 01/26/2023
©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 32 of 74
NEMO|etc.
TABLE 3A: STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
REFER TO NOTE 16 FOR VAPOR BARRIER OPTIONS
Base Insulation Layer Top Insulation Layer Roof Cover (Note 15)
Sys. Deck MDP
Primer Attach Attach Primer
No. (Note 1) Type Type Base Ply Ply Cap Ply (psf)
(Notes 6,7,8) (Notes 6,7,8)
(Optional) SBS-
Structural Min. 1.5-inch ACFoam II or H- (Optional) Additional SBS-AA,
C-40. None Insta Stik Insta Stik None SBS-SA-H AA, SBS-TA, APP- -135.0
concrete Shield layer(s) base insulation APP-TA
TA
(Optional) SBS-
Structural Min. 1.5-inch ACFoam II or H- Min. 0.25-inch SECUROCK SBS-AA,
C-41. None Insta Stik Insta Stik None SBS-SA-H AA, SBS-TA, APP- -217.5
concrete Shield Gypsum-Fiber Roof Board APP-TA
TA
(Optional) SBS-
Structural Min. 0.25-inch SECUROCK SBS-AA,
C-42. None Insta Stik None N/A None SBS-SA-H AA, SBS-TA, APP- -195.0
concrete Gypsum-Fiber Roof Board APP-TA
TA
(Optional) SBS-
Structural Min. 1.5-inch ACFoam II or H- (Optional) Additional SBS-AA,
C-43. None OB500 OB500 None SBS-SA-H AA, SBS-TA, APP- -135.0
concrete Shield layer(s) base insulation APP-TA
TA
(Optional) SBS-
Structural Min. 1.5-inch ACFoam II or H- Min. 0.25-inch SECUROCK SBS-AA,
C-44. None OB500 OB500 None SBS-SA-H AA, SBS-TA, APP- -217.5
concrete Shield Gypsum-Fiber Roof Board APP-TA
TA
(Optional) SBS-
Structural Min. 0.25-inch SECUROCK SBS-AA,
C-45. None OB500 None N/A None SBS-SA-H AA, SBS-TA, APP- -195.0
concrete Gypsum-Fiber Roof Board APP-TA
TA
(Optional) SBS-
Structural Min. 1.5-inch ACFoam II or H- Polyset BM or (Optional) Additional Polyset BM or SBS-AA,
C-46. None None SBS-SA-H AA, SBS-TA, APP- -270.0
concrete Shield Polyset CRA layer(s) base insulation Polyset CRA APP-TA
TA
(Optional) SBS-
Structural Min. 1.5-inch ACFoam II or H- Polyset BM or Min. 0.25-inch SECUROCK Polyset BM or SBS-AA,
C-47. None None SBS-SA-H AA, SBS-TA, APP- -217.5
concrete Shield Polyset CRA Gypsum-Fiber Roof Board Polyset CRA APP-TA
TA
(Optional) SBS-
Structural Min. 1.5-inch, min. 1.5 pcf Min. 0.25-inch SECUROCK SBS-AA,
C-48. None Polyset CRA Polyset CRA None SBS-SA-H AA, SBS-TA, APP- -180.0
concrete Insulfoam II Roofing EPS Gypsum-Fiber Roof Board APP-TA
TA
(Optional) SBS-
Structural Min. 1.5-inch, min. 2.0 pcf Min. 0.25-inch SECUROCK SBS-AA,
C-49. None Polyset CRA Polyset CRA None SBS-SA-H AA, SBS-TA, APP- -217.5
concrete Insulfoam IX Roofing EPS Gypsum-Fiber Roof Board APP-TA
TA
(Optional) SBS-
Structural Min. 1.5-inch Styrofoam Brand Min. 0.25-inch SECUROCK SBS-AA,
C-50. None Polyset CRA Polyset CRA None SBS-SA-H AA, SBS-TA, APP- -217.5
concrete Roofmate Gypsum-Fiber Roof Board APP-TA
TA
(Optional) SBS-
Structural Min. 0.25-inch SECUROCK Polyset BM or SBS-AA,
C-51. None None N/A None SBS-SA-H AA, SBS-TA, APP- -195.0
concrete Gypsum-Fiber Roof Board Polyset CRA APP-TA
TA

NEMO ETC, LLC 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Evaluation Report 3520.03.04-R30 for FL2533-R29
Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 30: 01/26/2023
©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 33 of 74
NEMO|etc.
TABLE 3A: STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
REFER TO NOTE 16 FOR VAPOR BARRIER OPTIONS
Base Insulation Layer Top Insulation Layer Roof Cover (Note 15)
Sys. Deck MDP
Primer Attach Attach Primer
No. (Note 1) Type Type Base Ply Ply Cap Ply (psf)
(Notes 6,7,8) (Notes 6,7,8)
CONVENTIONAL SYSTEMS:
Structural FlintPrime Min. 0.25-inch DensDeck, (Optional) SBS-
C-52. Min. 1.5-inch ACFoam II hot asphalt hot asphalt None SBS-TA SBS-TA -180.0
concrete QD DensDeck Prime TA
BP-AA, SBS-AA, (Optional) BP-
Structural FlintPrime (Optional) Min. 1.5-inch Min. 0.25-inch SECUROCK SBS-AA or
C-53. hot asphalt hot asphalt None SBS-TA or APP- AA, SBS-AA, SBS- -180.0
concrete QD ACFoam II Gypsum-Fiber Roof Board APP-TA
TA TA or APP-TA
(Optional) BP-
Structural FlintPrime (Optional) Min. 2-inch ACFoam Min. 0.25-inch SECUROCK BP-AA or SBS- SBS-AA or
C-54. hot asphalt hot asphalt None AA, SBS-AA, SBS- -225.0
concrete QD II, ENRGY 3 or H-Shield Gypsum-Fiber Roof Board AA APP-TA
TA or APP-TA
Structural FlintPrime (Optional) Min. 1.5-inch Min. 0.25-inch SECUROCK (Optional) APP-
C-55. hot asphalt hot asphalt None APP-TA APP-TA -252.5
concrete QD ACFoam II or H-Shield Gypsum-Fiber Roof Board TA
(Optional) BP-
Structural FlintPrime Min. 1.5-inch ACFoam II, ENRGY Min. 0.5-inch Structodek BP-AA or SBS- SBS-AA or
C-56. hot asphalt hot asphalt None AA, SBS-AA, SBS- -227.0
concrete QD 3 or H-Shield High Density Fiberboard AA APP-TA
TA or APP-TA
Structural FlintPrime (Optional) Min. 2-inch ACFoam Min. 0.25-inch SECUROCK SBS-TA or APP- (Optional) SBS-
C-57. hot asphalt hot asphalt None APP-TA -232.5
concrete QD II, ENRGY 3 or H-Shield Gypsum-Fiber Roof Board TA TA or APP-TA
(Optional) BP-
Structural FlintPrime Min. 1.5-inch ACFoam II, ENRGY BP-AA or SBS- SBS-AA or
C-58. hot asphalt Min. 0.25-inch DensDeck hot asphalt None AA, SBS-AA, SBS- -240.0
concrete QD 3 or H-Shield AA APP-TA
TA or APP-TA
(Optional) BP-
Structural FlintPrime Min. 0.75-inch FescoBoard BP-AA or SBS- SBS-AA or
C-59. Min. 1.5-inch ACFoam II hot asphalt hot asphalt None AA, SBS-AA, SBS- -412.0
concrete QD (homogeneous) AA APP-TA
TA or APP-TA
(Optional) BP-
Structural FlintPrime Min. 0.5-inch DuraBoard BP-AA or SBS- SBS-AA or
C-60. Min. 1.5-inch ACFoam II hot asphalt hot asphalt None AA, SBS-AA, SBS- -430.0
concrete QD (homogeneous) AA APP-TA
TA or APP-TA
0.5-inch Structodek High
Structural FlintPrime Density Fiberboard or min. 0.75- (Optional) BP-AA
C-61. hot asphalt None N/A None BP-AA SBS-AA -437.5
concrete QD inch Fesco Board or SBS-AA
(homogeneous)
0.25-inch DensDeck, DensDeck
Structural FlintPrime (Optional) SBS-
C-62. Prime or SECUROCK Gypsum- hot asphalt None N/A None SBS-TA SBS-AA -302.5
concrete QD AA or SBS-TA
Fiber Roof Board
0.25-inch DensDeck, DensDeck
Structural FlintPrime (Optional) BP-AA
C-63. Prime or SECUROCK Gypsum- hot asphalt None N/A None BP-AA SBS-AA -537.5
concrete QD or SBS-AA
Fiber Roof Board

NEMO ETC, LLC 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Evaluation Report 3520.03.04-R30 for FL2533-R29
Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 30: 01/26/2023
©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 34 of 74
NEMO|etc.
TABLE 3A: STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
REFER TO NOTE 16 FOR VAPOR BARRIER OPTIONS
Base Insulation Layer Top Insulation Layer Roof Cover (Note 15)
Sys. Deck MDP
Primer Attach Attach Primer
No. (Note 1) Type Type Base Ply Ply Cap Ply (psf)
(Notes 6,7,8) (Notes 6,7,8)
(Optional) BP-
Structural Min. 1.5-inch ACFoam II, ENRGY Min. 0.5-inch Structodek BP-AA or SBS- SBS-AA or
C-64. None M-OSFA M-OSFA None AA, SBS-AA, SBS- -127.5
concrete 3 or H-Shield High Density Fiberboard AA APP-TA
TA or APP-TA
(Optional) BP-
Structural Min. 1.5-inch ACFoam II, ENRGY Min. 0.5-inch Structodek BP-AA or SBS- SBS-AA or
C-65. None M-PG1 M-PG1 None AA, SBS-AA, SBS- -180.0
concrete 3 or H-Shield High Density Fiberboard AA APP-TA
TA or APP-TA
(Optional) BP-
Structural Min. 1.5-inch ACFoam II, ENRGY BP-AA or SBS- SBS-AA or
C-66. None M-OSFA Min. 0.25-inch DensDeck M-OSFA None AA, SBS-AA, SBS- -232.5
concrete 3 or H-Shield AA APP-TA
TA or APP-TA
(Optional) BP-
Structural Min. 1.5-inch ACFoam II, ENRGY BP-AA or SBS- SBS-AA or
C-67. None M-PG1 Min. 0.25-inch DensDeck M-PG1 None AA, SBS-AA, SBS- -240.0
concrete 3 or H-Shield AA APP-TA
TA or APP-TA
(Optional) BP-
Structural Min. 1.5-inch ACFoam II or H- Min. 0.25-inch DensDeck
C-68. None M-PG1 M-PG1 None BP-AA, SBS-AA AA, SBS-AA or SBS-AA -297.5
concrete Shield Prime
SBS-TA
(Optional) BP-
Structural Min. 2-inch ACFoam II, ENRGY 3 M-OSFA or M- Min. 0.25-inch SECUROCK M-OSFA or M- BP-AA or SBS- SBS-AA or
C-69. None None AA, SBS-AA, SBS- -225.0
concrete or H-Shield PG1 Gypsum-Fiber Roof Board PG1 AA APP-TA
TA or APP-TA
Structural Min. 2-inch ACFoam II, ENRGY 3 M-OSFA or M- Min. 0.25-inch SECUROCK M-OSFA or M- SBS-TA or APP- (Optional) SBS-
C-70. None None APP-TA -232.5
concrete or H-Shield PG1 Gypsum-Fiber Roof Board PG1 TA TA or APP-TA
Structural Min. 1.5-inch ACFoam II or H- M-OSFA or M- Min. 0.25-inch SECUROCK M-OSFA or M- (Optional) APP-
C-71. None None APP-TA APP-TA -252.5
concrete Shield PG1 Gypsum-Fiber Roof Board PG1 TA
(Optional) BP-
Structural Min. 1.5-inch ACFoam II or H- M-OSFA or M- Min. 0.25-inch SECUROCK M-OSFA or M- BP-AA, SBS-AA
C-72. None None AA, SBS-AA or SBS-AA -297.5
concrete Shield PG1 Gypsum-Fiber Roof Board PG1 or SBS-TA
SBS-TA
(Optional) BP-
Structural 0.5-inch Structodek High SBS-AA or
C-73. None M-PG1 None N/A None BP-AA, SBS-AA AA, SBS-AA, SBS- -195.0
concrete Density Fiberboard APP-TA
TA or APP-TA
Min. 0.25-inch DensDeck Prime BP-AA, SBS-AA, (Optional) BP-
Structural SBS-AA or
C-74. None or SECUROCK Gypsum-Fiber M-PG1 None N/A None SBS-TA or APP- AA, SBS-AA, SBS- -195.0
concrete APP-TA
Roof Board TA TA or APP-TA
Min. 0.25-inch DensDeck
Structural (Optional) Min. 1.5-inch M-OSFA or M- M-OSFA or M- SBS-AA or SBS- (Optional) SBS-
C-75. None Prime or SECUROCK None SBS-AA -315.0
concrete ACFoam II or H-Shield PG1, 6-inch o.c. PG1, 6-inch o.c. TA AA or SBS-TA
Gypsum-Fiber Roof Board

NEMO ETC, LLC 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Evaluation Report 3520.03.04-R30 for FL2533-R29
Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 30: 01/26/2023
©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 35 of 74
NEMO|etc.
TABLE 3A: STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
REFER TO NOTE 16 FOR VAPOR BARRIER OPTIONS
Base Insulation Layer Top Insulation Layer Roof Cover (Note 15)
Sys. Deck MDP
Primer Attach Attach Primer
No. (Note 1) Type Type Base Ply Ply Cap Ply (psf)
(Notes 6,7,8) (Notes 6,7,8)
Min. 0.25-inch DensDeck Flintlastic STA
Structural (Optional) Min. 1.5-inch M-OSFA or M- M-OSFA or M- (Optional) APP-
C-76. None Prime or SECUROCK None or Flintlastic APP-TA -315.0
concrete ACFoam II or H-Shield PG1, 6-inch o.c. PG1, 6-inch o.c. TA
Gypsum-Fiber Roof Board STA Plus
Min. 0.25-inch DensDeck Prime BP-AA, SBS-AA, (Optional) BP-
Structural SBS-AA or
C-77. None or SECUROCK Gypsum-Fiber M-PG1-EF-ECO None N/A None SBS-TA or APP- AA, SBS-AA, SBS- -195.0
concrete APP-TA
Roof Board TA TA or APP-TA
(Optional) BP-
Structural Min. 1.5-inch ACFoam II or H- Min. 0.25-inch DensDeck
C-78. None M-PG1-EF-ECO M-PG1-EF-ECO None BP-AA, SBS-AA AA, SBS-AA or SBS-AA -247.5
concrete Shield Prime
SBS-TA
BP-AA, SBS-AA, (Optional) BP-
Structural Min. 1.5-inch ACFoam II or H- Min. 0.25-inch SECUROCK SBS-AA or
C-79. None M-PG1-EF-ECO M-PG1-EF-ECO None SBS-TA or APP- AA, SBS-AA, SBS- -247.5
concrete Shield Gypsum-Fiber Roof Board APP-TA
TA TA or APP-TA
(Optional) BP-
Structural Min. 1.5-inch ACFoam II or H- Min. 0.25-inch DensDeck
C-80. None Insta Stik Insta Stik None BP-AA, SBS-AA AA, SBS-AA or SBS-AA -297.5
concrete Shield Prime
SBS-TA
(Optional) BP-
Structural Min. 2-inch ACFoam II, ENRGY 3 Min. 0.25-inch SECUROCK BP-AA or SBS- SBS-AA or
C-81. None Insta Stik Insta Stik None AA, SBS-AA, SBS- -225.0
concrete or H-Shield Gypsum-Fiber Roof Board AA APP-TA
TA or APP-TA
Structural Min. 2-inch ACFoam II, ENRGY 3 Min. 0.25-inch SECUROCK SBS-TA or APP- (Optional) SBS-
C-82. None Insta Stik Insta Stik None APP-TA -232.5
concrete or H-Shield Gypsum-Fiber Roof Board TA TA or APP-TA
Structural Min. 1.5-inch ACFoam II or H- Min. 0.25-inch SECUROCK (Optional) APP-
C-83. None Insta Stik Insta Stik None APP-TA APP-TA -252.5
concrete Shield Gypsum-Fiber Roof Board TA
(Optional) BP-
Structural Min. 1.5-inch ACFoam II or H- Min. 0.25-inch SECUROCK BP-AA, SBS-AA
C-84. None Insta Stik Insta Stik None AA, SBS-AA or SBS-AA -297.5
concrete Shield Gypsum-Fiber Roof Board or SBS-TA
SBS-TA
(Optional) BP-
Structural 0.5-inch Structodek High SBS-AA or
C-85. None Insta Stik None N/A None BP-AA, SBS-AA AA, SBS-AA, SBS- -195.0
concrete Density Fiberboard APP-TA
TA or APP-TA
BP-AA, SBS-AA, (Optional) BP-
Structural Min. 0.25-inch SECUROCK SBS-AA or
C-86. None Insta Stik None N/A None SBS-TA or APP- AA, SBS-AA, SBS- -195.0
concrete Gypsum-Fiber Roof Board APP-TA
TA TA or APP-TA
(Optional) BP-
Structural Min. 1.5-inch ACFoam II, ENRGY Min. 0.5-inch Structodek BP-AA or SBS- SBS-AA or
C-87. None OB500 OB500 None AA, SBS-AA, SBS- -120.0
concrete 3 or H-Shield High Density Fiberboard AA APP-TA
TA or APP-TA

NEMO ETC, LLC 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Evaluation Report 3520.03.04-R30 for FL2533-R29
Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 30: 01/26/2023
©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 36 of 74
NEMO|etc.
TABLE 3A: STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
REFER TO NOTE 16 FOR VAPOR BARRIER OPTIONS
Base Insulation Layer Top Insulation Layer Roof Cover (Note 15)
Sys. Deck MDP
Primer Attach Attach Primer
No. (Note 1) Type Type Base Ply Ply Cap Ply (psf)
(Notes 6,7,8) (Notes 6,7,8)
BP-AA, SBS-AA, (Optional) BP-
Structural Min. 0.25-inch DensDeck SBS-AA or
C-88. None Min. 1.5-inch ACFoam II OB500 OB500 None SBS-TA or APP- AA, SBS-AA, SBS- -150.0
concrete or DensDeck Prime APP-TA
TA TA or APP-TA
(Optional) BP-
Structural Min. 1.5-inch ACFoam II or H- Min. 0.25-inch DensDeck BP-AA, SBS-AA
C-89. None OB500 OB500 None AA, SBS-AA or SBS-AA -297.5
concrete Shield Prime or SBS-TA
SBS-TA
(Optional) BP-
Structural Min. 2-inch ACFoam II, ENRGY 3 Min. 0.25-inch SECUROCK BP-AA or SBS- SBS-AA or
C-90. None OB500 OB500 None AA, SBS-AA, SBS- -225.0
concrete or H-Shield Gypsum-Fiber Roof Board AA APP-TA
TA or APP-TA
Structural Min. 2-inch ACFoam II, ENRGY 3 Min. 0.25-inch SECUROCK SBS-TA or APP- (Optional) SBS-
C-91. None OB500 OB500 None APP-TA -232.5
concrete or H-Shield Gypsum-Fiber Roof Board TA TA or APP-TA
Structural Min. 1.5-inch ACFoam II or H- Min. 0.25-inch SECUROCK (Optional) APP-
C-92. None OB500 OB500 None APP-TA APP-TA -252.5
concrete Shield Gypsum-Fiber Roof Board TA
(Optional) BP-
Structural Min. 1.5-inch ACFoam II or H- Min. 0.25-inch SECUROCK BP-AA, SBS-AA
C-93. None OB500 OB500 None AA, SBS-AA or SBS-AA -297.5
concrete Shield Gypsum-Fiber Roof Board or SBS-TA
SBS-TA
(Optional) BP-
Structural 0.5-inch Structodek High SBS-AA or
C-94. None OB500 None N/A None BP-AA, SBS-AA AA, SBS-AA, SBS- -195.0
concrete Density Fiberboard APP-TA
TA or APP-TA
BP-AA, SBS-AA, (Optional) BP-
Structural Min. 0.25-inch SECUROCK SBS-AA or
C-95. None OB500 None N/A None SBS-TA or APP- AA, SBS-AA, SBS- -195.0
concrete Gypsum-Fiber Roof Board APP-TA
TA TA or APP-TA
Min. 1-inch ENRGY 3, H-Shield (Optional) BP-
Structural Polyset BM or Min. 0.5-inch Structodek BP-AA or SBS- SBS-AA or
C-96. None or H-Shield CG or min. 1.5-inch Polyset CRA None AA, SBS-AA, SBS- -180.0
concrete Polyset CRA High Density Fiberboard AA APP-TA
Multi-Max FA3 or Ultra-Max TA or APP-TA
Min. 1-inch ENRGY 3, H-Shield,
(Optional) BP-
Structural or H-Shield CG, min. 1.3-inch Polyset BM or Min. 0.25-inch SECUROCK Polyset BM or BP-AA or SBS- SBS-AA or
C-97. None None AA, SBS-AA, SBS- -225.0
concrete ACFoam III or min. 1.5-inch Polyset CRA Gypsum-Fiber Roof Board Polyset CRA AA APP-TA
TA or APP-TA
Multi-Max FA3 or Ultra-Max
Min. 1-inch ENRGY 3, H-Shield
Structural Polyset BM or Min. 0.25-inch SECUROCK Polyset BM or SBS-TA or APP- (Optional) SBS-
C-98. None or H-Shield CG or min. 1.5-inch None APP-TA -232.5
concrete Polyset CRA Gypsum-Fiber Roof Board Polyset CRA TA TA or APP-TA
Multi-Max FA3 or Ultra-Max
Min. 1-inch ENRGY 3, H-Shield (Optional) BP-
Structural Polyset BM or Polyset BM or BP-AA or SBS- SBS-AA or
C-99. None or H-Shield CG or min. 1.5-inch Min. 0.25-inch DensDeck None AA, SBS-AA, SBS- -240.0
concrete Polyset CRA Polyset CRA AA APP-TA
Multi-Max FA3 or Ultra-Max TA or APP-TA

NEMO ETC, LLC 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Evaluation Report 3520.03.04-R30 for FL2533-R29
Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 30: 01/26/2023
©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 37 of 74
NEMO|etc.
TABLE 3A: STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
REFER TO NOTE 16 FOR VAPOR BARRIER OPTIONS
Base Insulation Layer Top Insulation Layer Roof Cover (Note 15)
Sys. Deck MDP
Primer Attach Attach Primer
No. (Note 1) Type Type Base Ply Ply Cap Ply (psf)
(Notes 6,7,8) (Notes 6,7,8)
(Optional) BP-
Structural 0.5-inch Structodek High Polyset BM or SBS-AA or
C-100. None None N/A None BP-AA, SBS-AA AA, SBS-AA, SBS- -195.0
concrete Density Fiberboard Polyset CRA APP-TA
TA or APP-TA
BP-AA, SBS-AA, (Optional) BP-
Structural Min. 0.25-inch SECUROCK Polyset BM or SBS-AA or
C-101. None None N/A None SBS-TA or APP- AA, SBS-AA, SBS- -195.0
concrete Gypsum-Fiber Roof Board Polyset CRA APP-TA
TA TA or APP-TA
SPOT- OR STRIP-MOPPED SYSTEMS:
Structural FlintPrime Min. 1.5-inch ACFoam II, ENRGY (Optional) Additional BP-AA3, 24- (Optional) BP-
C-102. hot asphalt hot asphalt None SBS-AA -37.5
concrete QD 3 or H-Shield layer(s) of base insulation inch grid AA, SBS-AA
COLD-APPLIED SYSTEMS:
(Optional)
Flintlastic Poly
Structural (Optional) Min. 1.5-inch M-OSFA or M- Min. 0.25-inch DEXcell FA M-OSFA or M- Flintlastic Poly
C-103. None None SMS Base Sheet SBS-CA1 -90.0
concrete ACFoam II or H-Shield PG1 Glass Mat Roof Board PG1 SMS Base Sheet
in Karnak #81
in Karnak #81
Structural (Optional) Min. 1.5-inch M-OSFA or M- Min. 0.5-inch ACFoam-HD M-OSFA or M-
C-104. None None SBS-CA1 None SBS-CA1 -97.5
concrete ACFoam II or H-Shield PG1 CoverBoard or H-Shield HD PG1
Structural (Optional) Min. 1.5-inch M-OSFA or M- Min. 0.5-inch ACFoam-HD M-OSFA or M-
C-105. None None SBS-CA4 None SBS-CA4 -97.5
concrete ACFoam II or H-Shield PG1 CoverBoard or H-Shield HD PG1
Structural (Optional) Min. 1.5-inch M-OSFA or M- Min. 2-inch H-Shield HD M-OSFA or M-
C-106. None None SBS-CA4 None SBS-CA4 -97.5
concrete ACFoam II or H-Shield PG1 Composite CG PG1
Structural Min. 0.5-inch ACFoam II or H- M-OSFA or M- Min. 0.25-inch SECUROCK M-OSFA or M-
C-107. None None SBS-CA1 None SBS-CA1 -105.0
concrete Shield PG1 Gypsum-Fiber Roof Board PG1
Structural Min. 0.5-inch ACFoam II or H- M-OSFA or M- Min. 0.25-inch SECUROCK M-OSFA or M-
C-108. None None SBS-CA4 None SBS-CA4 -105.0
concrete Shield PG1 Gypsum-Fiber Roof Board PG1
(Optional)
Flintlastic Poly
Structural (Optional) Min. 1.5-inch M-OSFA or M- Min. 0.25-inch DEXcell FA M-OSFA or M- Flintlastic Poly
C-109. None None SMS Base Sheet SBS-CA1 -112.5
concrete ACFoam II or H-Shield PG1, 6-inch o.c. Glass Mat Roof Board PG1, 6-inch o.c. SMS Base Sheet
in Karnak #81
in Karnak #81
Structural (Optional) Min. 1.5-inch
C-110. None M-PG1-EF-ECO Min. 0.5-inch H-Shield HD M-PG1-EF-ECO None SBS-CA1 None SBS-CA1 -97.5
concrete ACFoam II or H-Shield
Structural (Optional) Min. 1.5-inch
C-111. None M-PG1-EF-ECO Min. 0.5-inch H-Shield HD M-PG1-EF-ECO None SBS-CA4 None SBS-CA4 -97.5
concrete ACFoam II or H-Shield
Structural (Optional) Min. 1.5-inch Min. 2-inch H-Shield HD -97.5
C-112. None M-PG1-EF-ECO M-PG1-EF-ECO None SBS-CA4 None SBS-CA4
concrete ACFoam II or H-Shield Composite CG CTR-A12

NEMO ETC, LLC 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Evaluation Report 3520.03.04-R30 for FL2533-R29
Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 30: 01/26/2023
©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 38 of 74
NEMO|etc.
TABLE 3A: STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
REFER TO NOTE 16 FOR VAPOR BARRIER OPTIONS
Base Insulation Layer Top Insulation Layer Roof Cover (Note 15)
Sys. Deck MDP
Primer Attach Attach Primer
No. (Note 1) Type Type Base Ply Ply Cap Ply (psf)
(Notes 6,7,8) (Notes 6,7,8)
Structural Min. 0.5-inch ACFoam II or H- Min. 0.25-inch SECUROCK
C-113. None M-PG1-EF-ECO M-PG1-EF-ECO None SBS-CA1 None SBS-CA1 -105.0
concrete Shield Gypsum-Fiber Roof Board
Structural Min. 0.5-inch ACFoam II or H- Min. 0.25-inch SECUROCK
C-114. None M-PG1-EF-ECO M-PG1-EF-ECO None SBS-CA4 None SBS-CA4 -105.0
concrete Shield Gypsum-Fiber Roof Board
Structural (Optional) Min. 0.5-inch Min. 1.5-inch ACFoam III
C-115. None OB500 OB500 None SBS-CA1 None SBS-CA1 -82.5
concrete ACFoam II or H-Shield or H-Shield CG
Structural Min. 0.5-inch ACFoam II or H- Min. 0.25-inch SECUROCK
C-116. None OB500 OB500 None SBS-CA1 None SBS-CA1 -105.0
concrete Shield Gypsum-Fiber Roof Board
Structural Min. 0.5-inch ACFoam II or H- Min. 0.25-inch SECUROCK
C-117. None OB500 OB500 None SBS-CA4 None SBS-CA4 -105.0
concrete Shield Gypsum-Fiber Roof Board
Structural (Optional) Min. 0.5-inch Polyset BM or Min. 1.5-inch ACFoam III Polyset BM or
C-118. None None SBS-CA1 None SBS-CA1 -82.5
concrete ACFoam II or H-Shield Polyset CRA or H-Shield CG Polyset CRA
Structural Min. 0.5-inch ACFoam II or H- Polyset BM or Min. 0.25-inch SECUROCK Polyset BM or
C-119. None None SBS-CA1 None SBS-CA1 -105.0
concrete Shield Polyset CRA Gypsum-Fiber Roof Board Polyset CRA
Structural Min. 0.5-inch ACFoam II or H- Polyset BM or Min. 0.25-inch SECUROCK Polyset BM or
C-120. None None SBS-CA4 None SBS-CA4 -105.0
concrete Shield Polyset CRA Gypsum-Fiber Roof Board Polyset CRA

TABLE 3B: STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)


SYSTEM TYPE A-3: BONDED TEMP ROOF, BONDED INSULATION, BONDED ROOF COVER
Base Insulation Layer Top Insulation Layer Roof Cover (Note 15)
System Deck
Primer Temp Roof Attach Attach MDP (psf)
No. (Note 1) Type Type Base Ply Ply Cap Ply
(Notes 6,7,8) (Notes 6,7,8)
COLD-APPLIED SYSTEMS:
Structural FlintPrime Flintlastic SA PlyBase, (Optional) Min. 0.5-inch Min. 1.5-inch ACFoam III or H-
C-121. OB500 OB500 SBS-CA1 None SBS-CA1 -82.5
concrete QD self-adhered ACFoam II or H-Shield Shield CG
Structural FlintPrime Flintlastic SA PlyBase, Min. 0.5-inch ACFoam II or H- Min. 0.25-inch SECUROCK
C-122. OB500 OB500 SBS-CA1 None SBS-CA1 -82.5
concrete QD self-adhered Shield Gypsum-Fiber Roof Board
Structural FlintPrime Flintlastic SA PlyBase, Min. 0.5-inch ACFoam II or H- Min. 0.25-inch SECUROCK
C-123. OB500 OB500 SBS-CA4 None SBS-CA4 -82.5
concrete QD self-adhered Shield Gypsum-Fiber Roof Board

NEMO ETC, LLC 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Evaluation Report 3520.03.04-R30 for FL2533-R29
Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 30: 01/26/2023
©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 39 of 74
NEMO|etc.
TABLE 3C: STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE F: NON-INSULATED, BONDED ROOF COVER
System Deck Roof Cover (Note 15) MDP
Primer
No. (Note 1) Base Ply Ply Cap Ply (psf)
SELF-ADHERING SYSTEMS:
C-124. Structural concrete FlintPrime QD SBS-SA (Optional) SBS-SA SBS-SA -630.0
HYBRID SYSTEMS:
C-125. Structural concrete FlintPrime QD Flintlastic Ultra Glass SA (Optional) SBS-AA SBS-AA -135.0
C-126. Structural concrete FlintPrime QD SBS-SA-H (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -150.0
C-127. Structural concrete FlintPrime QD Flintlastic Ultra Glass SA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -322.5
C-128. Structural concrete FlintPrime QD SBS-SA-H (Optional) BP-AA, SBS-AA SBS-AA -240.0
C-129. Structural concrete FlintPrime QD BP-AA, SBS-AA SBS-SA-H SBS-AA, SBS-TA, APP-TA -635.0
CONVENTIONAL SYSTEMS:
C-130. Structural concrete FlintPrime QD APP-TA (Optional) APP-TA APP-TA -420.0
C-131. Structural concrete FlintPrime QD BP-AA, SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -635.0
COLD-APPLIED SYSTEMS:
C-132. Structural concrete FlintPrime QD SBS-CA1 (Optional) SBS-CA1 SBS-CA1 -262.5

NEMO ETC, LLC 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Evaluation Report 3520.03.04-R30 for FL2533-R29
Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 30: 01/26/2023
©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 40 of 74
NEMO|etc.
TABLE 4A: LIGHTWEIGHT CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
Base Insulation Layer Coverboard Roof Cover (Note 15)
System Deck Lightweight Concrete MDP
No. (Note 1) (Note 14)
Attach Attach (psf)
Type Type Base Ply Ply Cap Ply
(Notes 6,7,8) (Notes 6,7,8)
CELCORE (FL2037):
SELF-ADHERING SYSTEMS:
Min. 22 ga.,
Min. 300 psi Celcore MF Cellular One or more layer(s), min. Min. 0.25-inch
Type BV, Grade (Optional) SBS-
LWC-1 Concrete with Celcore HS 1.5-inch ACFoam II, ACFoam M-OSFA SECUROCK Gypsum- M-OSFA SBS-SA SBS-SA -52.5
33 steel, 6 ft SA
Rheology Modifying Admixture III, H-Shield or H-Shield CG Fiber Roof Board
span
Min. 22 ga.,
Min. 300 psi Celcore MF Cellular One or more layer(s), min. Min. 0.25-inch
Type BV, Grade (Optional) SBS-
LWC-2 Concrete with Celcore HS 1.5-inch ACFoam II, ACFoam M-PG1 SECUROCK Gypsum- M-PG1 SBS-SA SBS-SA -52.5
33 steel, 6 ft SA
Rheology Modifying Admixture III, H-Shield or H-Shield CG Fiber Roof Board
span
Min. 22 ga.,
Min. 300 psi Celcore MF Cellular One or more layer(s), min. Min. 0.25-inch
Type BV, Grade (Optional) SBS-
LWC-3 Concrete with Celcore HS 1.5-inch ACFoam II, ACFoam OB500 SECUROCK Gypsum- OB500 SBS-SA SBS-SA -52.5
33 steel, 6 ft SA
Rheology Modifying Admixture III, H-Shield or H-Shield CG Fiber Roof Board
span
Min. 22 ga.,
Min. 300 psi Celcore MF Cellular One or more layer(s), min. Min. 0.25-inch
Type BV, Grade (Optional) SBS-
LWC-4 Concrete with Celcore HS 1.5-inch ACFoam II, ACFoam Polyset BM SECUROCK Gypsum- Polyset BM SBS-SA SBS-SA -52.5
33 steel, 6 ft SA
Rheology Modifying Admixture III, H-Shield or H-Shield CG Fiber Roof Board
span
Min. 22 ga.,
Min. 300 psi Celcore MF Cellular One or more layer(s), min. Min. 0.25-inch
Type BV, Grade (Optional) SBS-
LWC-5 Concrete with Celcore HS 1.5-inch ACFoam II, ACFoam Polyset CRA SECUROCK Gypsum- Polyset CRA SBS-SA SBS-SA -52.5
33 steel, 6 ft SA
Rheology Modifying Admixture III, H-Shield or H-Shield CG Fiber Roof Board
span
HYBRID SYSTEMS:
M-OSFA,
Min. 22 ga., (Optional) Min. 0.25- M-OSFA, M-
Min. 300 psi Celcore MF Cellular One or more layer(s), min. M-PG1, (Optional) SBS-
Type BV, Grade inch SECUROCK PG1, OB500, SBS-AA or
LWC-6 Concrete with Celcore HS 1.5-inch ACFoam II, ACFoam OB500, SBS-SA-H AA, SBS-TA or -52.5
33 steel, 6 ft Gypsum-Fiber Roof Polyset BM, APP-TA
Rheology Modifying Admixture III, H-Shield or H-Shield CG Polyset BM, APP-TA
span Board Polyset CRA
Polyset CRA
CONVENTIONAL SYSTEMS:
Min. 22 ga.,
Min. 300 psi Celcore MF Cellular One or more layer(s), min. Min. 0.25-inch BP-AA or (Optional) BP-
Type BV, Grade SBS-AA or
LWC-7 Concrete with Celcore HS 1.5-inch ACFoam II, ACFoam M-OSFA SECUROCK Gypsum- M-OSFA SBS-AA, SBS- AA, SBS-AA, SBS- -52.5
33 steel, 6 ft APP-TA
Rheology Modifying Admixture III, H-Shield or H-Shield CG Fiber Roof Board TA or APP-TA TA or APP-TA
span
Min. 22 ga.,
Min. 300 psi Celcore MF Cellular One or more layer(s), min. Min. 0.25-inch BP-AA or (Optional) BP-
Type BV, Grade SBS-AA or
LWC-8 Concrete with Celcore HS 1.5-inch ACFoam II, ACFoam M-PG1 SECUROCK Gypsum- M-PG1 SBS-AA, SBS- AA, SBS-AA, SBS- -52.5
33 steel, 6 ft APP-TA
Rheology Modifying Admixture III, H-Shield or H-Shield CG Fiber Roof Board TA or APP-TA TA or APP-TA
span

NEMO ETC, LLC 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Evaluation Report 3520.03.04-R30 for FL2533-R29
Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 30: 01/26/2023
©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 41 of 74
NEMO|etc.
TABLE 4A: LIGHTWEIGHT CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
Base Insulation Layer Coverboard Roof Cover (Note 15)
System Deck Lightweight Concrete MDP
No. (Note 1) (Note 14)
Attach Attach (psf)
Type Type Base Ply Ply Cap Ply
(Notes 6,7,8) (Notes 6,7,8)
Min. 22 ga.,
Min. 300 psi Celcore MF Cellular One or more layer(s), min. Min. 0.25-inch BP-AA or (Optional) BP-
Type BV, Grade SBS-AA or
LWC-9 Concrete with Celcore HS 1.5-inch ACFoam II, ACFoam OB500 SECUROCK Gypsum- OB500 SBS-AA, SBS- AA, SBS-AA, SBS- -52.5
33 steel, 6 ft APP-TA
Rheology Modifying Admixture III, H-Shield or H-Shield CG Fiber Roof Board TA or APP-TA TA or APP-TA
span
Min. 22 ga.,
Min. 300 psi Celcore MF Cellular One or more layer(s), min. Min. 0.25-inch BP-AA or (Optional) BP-
Type BV, Grade SBS-AA or
LWC-10 Concrete with Celcore HS 1.5-inch ACFoam II, ACFoam Polyset BM SECUROCK Gypsum- Polyset BM SBS-AA, SBS- AA, SBS-AA, SBS- -52.5
33 steel, 6 ft APP-TA
Rheology Modifying Admixture III, H-Shield or H-Shield CG Fiber Roof Board TA or APP-TA TA or APP-TA
span
Min. 22 ga.,
Min. 300 psi Celcore MF Cellular One or more layer(s), min. Min. 0.25-inch BP-AA or (Optional) BP-
Type BV, Grade SBS-AA or
LWC-11 Concrete with Celcore HS 1.5-inch ACFoam II, ACFoam Polyset CRA SECUROCK Gypsum- Polyset CRA SBS-AA, SBS- AA, SBS-AA, SBS- -52.5
33 steel, 6 ft APP-TA
Rheology Modifying Admixture III, H-Shield or H-Shield CG Fiber Roof Board TA or APP-TA TA or APP-TA
span
ELASTIZELL (FL4994):
COLD APPLIED SYSTEMS:
Min. 22 ga.,
(Optional) Additional
Type BV, Grade Min. 350 psi, min 2-inch Range II OB500, 6- OB500, 6-inch BP-CA3 or (Optional) BP-
LWC-12 Min. 1.5-inch H-Shield CG layers of base SBS-CA3 -60.0
33 steel, 5 ft Elastizell with Zell-Crete Fibers. inch o.c. o.c. SBS-CA3 CA3 or SBS-CA3
insulation
span
Min. 350 psi, min 2-inch Range II
Min. 22 ga., Elastizell with Zell-Crete Fibers.
(Optional) Additional
Type BV, Grade When walkable, attach LWC with OB500, 6- OB500, 6-inch BP-CA3 or (Optional) BP-
LWC-13 Min. 1.5-inch H-Shield CG layers of base SBS-CA3 -67.5
33 steel, 5 ft Trufast #14 HD with Trufast 3” inch o.c. o.c. SBS-CA3 CA3 or SBS-CA3
insulation
span Metal Insulation Plates at 1 per 8
ft2 through to the structural deck.

NEMO ETC, LLC 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Evaluation Report 3520.03.04-R30 for FL2533-R29
Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 30: 01/26/2023
©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 42 of 74
NEMO|etc.
TABLE 4B: LIGHTWEIGHT CONCRETE OVER STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
Base Insulation Layer Coverboard Roof Cover (Note 15)
System Deck Lightweight Concrete MDP
No. (Note 1) (Note 14)
Attach Attach (psf)
Type Type Primer Base Ply Ply Cap Ply
(Notes 6,7,8) (Notes 6,7,8)
CELCORE (FL2037):
SELF-ADHERING SYSTEMS:
Min. 300 psi, min. 2-inch Celcore MF One or more layer(s), min.
Cellular Concrete with Celcore HS
Structural 1.5-inch ACFoam II, FlintPrime (Optional)
LWC-14 Rheology Modifying Admixture; M-OSFA Min. 0.25-inch DensDeck M-OSFA SBS-SA SBS-SA -90.0
concrete treated with Celcore PVA Curing ACFoam III, H-Shield or H- QD SBS-SA
Compound Shield CG
Min. 300 psi, min. 2-inch Celcore MF One or more layer(s), min.
Cellular Concrete with Celcore HS Min. 0.25-inch
Structural 1.5-inch ACFoam II, (Optional)
LWC-15 Rheology Modifying Admixture; M-OSFA SECUROCK Gypsum-Fiber M-OSFA None SBS-SA SBS-SA -90.0
concrete treated with Celcore PVA Curing ACFoam III, H-Shield or H- SBS-SA
Roof Board
Compound Shield CG
Min. 300 psi, min. 2-inch Celcore MF
Cellular Concrete with Celcore HS One or more layer(s), min.
Min. 0.25-inch
Structural Rheology Modifying Admixture; 1.5-inch ACFoam II, (Optional)
LWC-16 treated with Celcore PVA Curing
M-OSFA SECUROCK Gypsum-Fiber M-OSFA None SBS-SA SBS-SA -172.5
concrete ACFoam III, H-Shield or H- SBS-SA
Compound and surfaced with Celcore Roof Board
Shield CG
Sanded Bonding Surface (SBS)
Min. 300 psi, min. 2-inch Celcore MF
Cellular Concrete with Celcore HS One or more layer(s), min.
Structural Rheology Modifying Admixture; 1.5-inch ACFoam II, FlintPrime (Optional)
LWC-17 treated with Celcore PVA Curing
M-OSFA Min. 0.25-inch DensDeck M-OSFA SBS-SA SBS-SA -192.5
concrete ACFoam III, H-Shield or H- QD SBS-SA
Compound and surfaced with Celcore Shield CG
Sanded Bonding Surface (SBS)
Min. 300 psi, min. 2-inch Celcore MF
Cellular Concrete with Celcore HS One or more layer(s), min.
Min. 0.25-inch
Structural Rheology Modifying Admixture; 1.5-inch ACFoam II, FlintPrime (Optional)
LWC-18 treated with Celcore PVA Curing
M-OSFA SECUROCK Gypsum-Fiber M-OSFA SBS-SA SBS-SA -217.5
concrete ACFoam III, H-Shield or H- QD SBS-SA
Compound and surfaced with Celcore Roof Board
Shield CG
Sanded Bonding Surface (SBS)
Min. 300 psi, min. 2-inch Celcore MF One or more layer(s), min.
Cellular Concrete with Celcore HS Min. 0.25-inch
Structural 1.5-inch ACFoam II, (Optional)
LWC-19 Rheology Modifying Admixture; M-PG1 SECUROCK Gypsum-Fiber M-PG1 None SBS-SA SBS-SA -172.5
concrete treated with Celcore PVA Curing ACFoam III, H-Shield or H- SBS-SA
Roof Board
Compound Shield CG
Min. 300 psi, min. 2-inch Celcore MF
Cellular Concrete with Celcore HS One or more layer(s), min.
Min. 0.25-inch
Structural Rheology Modifying Admixture; 1.5-inch ACFoam II, (Optional)
LWC-20 treated with Celcore PVA Curing
M-PG1 SECUROCK Gypsum-Fiber M-PG1 None SBS-SA SBS-SA -172.5
concrete ACFoam III, H-Shield or H- SBS-SA
Compound and surfaced with Celcore Roof Board
Shield CG
Sanded Bonding Surface (SBS)

NEMO ETC, LLC 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Evaluation Report 3520.03.04-R30 for FL2533-R29
Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 30: 01/26/2023
©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 43 of 74
NEMO|etc.
TABLE 4B: LIGHTWEIGHT CONCRETE OVER STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
Base Insulation Layer Coverboard Roof Cover (Note 15)
System Deck Lightweight Concrete MDP
No. (Note 1) (Note 14)
Attach Attach (psf)
Type Type Primer Base Ply Ply Cap Ply
(Notes 6,7,8) (Notes 6,7,8)
Min. 300 psi, min. 2-inch Celcore MF One or more layer(s), min.
Cellular Concrete with Celcore HS
Structural 1.5-inch ACFoam II, FlintPrime (Optional)
LWC-21 Rheology Modifying Admixture; M-PG1 Min. 0.25-inch DensDeck M-PG1 SBS-SA SBS-SA -192.5
concrete treated with Celcore PVA Curing ACFoam III, H-Shield or H- QD SBS-SA
Compound Shield CG
Min. 300 psi, min. 2-inch Celcore MF
Cellular Concrete with Celcore HS One or more layer(s), min.
Structural Rheology Modifying Admixture; 1.5-inch ACFoam II, FlintPrime (Optional)
LWC-22 treated with Celcore PVA Curing
M-PG1 Min. 0.25-inch DensDeck M-PG1 SBS-SA SBS-SA -192.5
concrete ACFoam III, H-Shield or H- QD SBS-SA
Compound and surfaced with Celcore Shield CG
Sanded Bonding Surface (SBS)
Min. 300 psi, min. 2-inch Celcore MF One or more layer(s), min.
Cellular Concrete with Celcore HS Min. 0.25-inch
Structural 1.5-inch ACFoam II, FlintPrime (Optional)
LWC-23 Rheology Modifying Admixture; M-PG1 SECUROCK Gypsum-Fiber M-PG1 SBS-SA SBS-SA -240.0
concrete treated with Celcore PVA Curing ACFoam III, H-Shield or H- QD SBS-SA
Roof Board
Compound Shield CG
Min. 300 psi, min. 2-inch Celcore MF
Cellular Concrete with Celcore HS One or more layer(s), min.
Min. 0.25-inch
Structural Rheology Modifying Admixture; 1.5-inch ACFoam II, FlintPrime (Optional)
LWC-24 treated with Celcore PVA Curing
M-PG1 SECUROCK Gypsum-Fiber M-PG1 SBS-SA SBS-SA -232.5
concrete ACFoam III, H-Shield or H- QD SBS-SA
Compound and surfaced with Celcore Roof Board
Shield CG
Sanded Bonding Surface (SBS)
One or more layer(s), min.
Min. 300 psi Celcore MF Cellular Min. 0.25-inch
Structural 1.5-inch ACFoam II, (Optional)
LWC-25 Concrete with Celcore HS Rheology OB500 SECUROCK Gypsum-Fiber OB500 None SBS-SA SBS-SA -172.5
concrete Modifying Admixture ACFoam III, H-Shield or H- SBS-SA
Roof Board
Shield CG
Min. 1-inch ENRGY 3, H-
Min. 0.25-inch
Structural Min. 200 psi, min. 2-inch Celcore Shield or H-Shield CG or (Optional)
LWC-26 Cellular Concrete
Polyset CRA SECUROCK Gypsum-Fiber Polyset CRA None SBS-SA SBS-SA -172.5
concrete min. 1.5-inch Multi-Max SBS-SA
Roof Board
FA3 or Ultra-Max
One or more layer(s), min.
Min. 300 psi Celcore MF Cellular Min. 0.25-inch
Structural 1.5-inch ACFoam II, (Optional)
LWC-27 Concrete with Celcore HS Rheology Polyset CRA SECUROCK Gypsum-Fiber Polyset CRA None SBS-SA SBS-SA -172.5
concrete Modifying Admixture ACFoam III, H-Shield or H- SBS-SA
Roof Board
Shield CG
Min. 1-inch ENRGY 3, H-
Structural Min. 200 psi, min. 2-inch Celcore Shield or H-Shield CG or FlintPrime (Optional)
LWC-28 Cellular Concrete
Polyset CRA Min. 0.25-inch DensDeck Polyset CRA SBS-SA SBS-SA -180.0
concrete min. 1.5-inch Multi-Max QD SBS-SA
FA3 or Ultra-Max
HYBRID SYSTEMS:

NEMO ETC, LLC 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Evaluation Report 3520.03.04-R30 for FL2533-R29
Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 30: 01/26/2023
©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 44 of 74
NEMO|etc.
TABLE 4B: LIGHTWEIGHT CONCRETE OVER STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
Base Insulation Layer Coverboard Roof Cover (Note 15)
System Deck Lightweight Concrete MDP
No. (Note 1) (Note 14)
Attach Attach (psf)
Type Type Primer Base Ply Ply Cap Ply
(Notes 6,7,8) (Notes 6,7,8)
Min. 300 psi, min. 2-inch Celcore MF (Optional) Min. 0.25-inch
Cellular Concrete with Celcore HS One or more layer(s), min. (Optional) SBS-AA,
Structural DensDeck Prime or
LWC-29 Rheology Modifying Admixture; 1.5-inch ACFoam II or H- M-OSFA M-OSFA None SBS-SA-H SBS-AA, SBS- SBS-TA, -90.0
concrete treated with Celcore PVA Curing SECUROCK Gypsum-Fiber
Shield TA, APP-TA APP-TA
Compound Roof Board
Min. 300 psi, min. 2-inch Celcore MF
Cellular Concrete with Celcore HS (Optional) Min. 0.25-inch
One or more layer(s), min. (Optional) SBS-AA,
Structural Rheology Modifying Admixture; DensDeck Prime or
LWC-30 treated with Celcore PVA Curing
1.5-inch ACFoam II or H- M-OSFA M-OSFA None SBS-SA-H SBS-AA, SBS- SBS-TA, -217.5
concrete SECUROCK Gypsum-Fiber
Compound and surfaced with Celcore Shield TA, APP-TA APP-TA
Roof Board
Sanded Bonding Surface (SBS)
Min. 300 psi, min. 2-inch Celcore MF
Cellular Concrete with Celcore HS (Optional) Min. 0.25-inch
One or more layer(s), min. (Optional) SBS-AA,
Structural Rheology Modifying Admixture; DensDeck Prime or
LWC-31 treated with Celcore PVA Curing
1.5-inch ACFoam II or H- M-PG1 M-PG1 None SBS-SA-H SBS-AA, SBS- SBS-TA, -232.5
concrete SECUROCK Gypsum-Fiber
Compound and surfaced with Celcore Shield TA, APP-TA APP-TA
Roof Board
Sanded Bonding Surface (SBS)
Min. 300 psi, min. 2-inch Celcore MF (Optional) Min. 0.25-inch
Cellular Concrete with Celcore HS One or more layer(s), min. (Optional) SBS-AA,
Structural DensDeck Prime or
LWC-32 Rheology Modifying Admixture; 1.5-inch ACFoam II or H- M-PG1 M-PG1 None SBS-SA-H SBS-AA, SBS- SBS-TA, -240.0
concrete treated with Celcore PVA Curing SECUROCK Gypsum-Fiber
Shield TA, APP-TA APP-TA
Compound Roof Board
One or more layer(s), min.
Min. 300 psi Celcore MF Cellular (Optional) Min. 0.25-inch (Optional) SBS-AA
Structural 1.5-inch ACFoam II,
LWC-33 Concrete with Celcore HS Rheology OB500 SECUROCK Gypsum-Fiber OB500 None SBS-SA-H SBS-AA, SBS- or APP- -215.0
concrete Modifying Admixture ACFoam III, H-Shield or H-
Roof Board TA or APP-TA TA
Shield CG
One or more layer(s), min.
Min. 300 psi Celcore MF Cellular Polyset BM (Optional) Min. 0.25-inch (Optional) SBS-AA
Structural 1.5-inch ACFoam II, Polyset BM or
LWC-34 Concrete with Celcore HS Rheology or Polyset SECUROCK Gypsum-Fiber None SBS-SA-H SBS-AA, SBS- or APP- -215.0
concrete Modifying Admixture
ACFoam III, H-Shield or H- Polyset CRA
CRA Roof Board TA or APP-TA TA
Shield CG
CONVENTIONAL SYSTEMS:
Min. 300 psi, min. 2-inch Celcore MF One or more layer(s), min. Min. 0.25-inch DensDeck (Optional)
Cellular Concrete with Celcore HS BP-AA, SBS- SBS-AA
Structural 1.5-inch ACFoam II, Prime or SECUROCK BP-AA, SBS-
LWC-35 Rheology Modifying Admixture; M-OSFA M-OSFA None AA, SBS-TA or APP- -90.0
concrete treated with Celcore PVA Curing ACFoam III, H-Shield or H- Gypsum-Fiber Roof AA, SBS-TA
or APP-TA TA
Compound Shield CG Board or APP-TA
Min. 300 psi, min. 2-inch Celcore MF
Cellular Concrete with Celcore HS One or more layer(s), min. Min. 0.25-inch DensDeck (Optional)
BP-AA, SBS- SBS-AA
Structural Rheology Modifying Admixture; 1.5-inch ACFoam II, Prime or SECUROCK BP-AA, SBS-
LWC-36 treated with Celcore PVA Curing
M-OSFA M-OSFA None AA, SBS-TA or APP- -217.5
concrete ACFoam III, H-Shield or H- Gypsum-Fiber Roof AA, SBS-TA
Compound and surfaced with Celcore or APP-TA TA
Shield CG Board or APP-TA
Sanded Bonding Surface (SBS)

NEMO ETC, LLC 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Evaluation Report 3520.03.04-R30 for FL2533-R29
Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 30: 01/26/2023
©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 45 of 74
NEMO|etc.
TABLE 4B: LIGHTWEIGHT CONCRETE OVER STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
Base Insulation Layer Coverboard Roof Cover (Note 15)
System Deck Lightweight Concrete MDP
No. (Note 1) (Note 14)
Attach Attach (psf)
Type Type Primer Base Ply Ply Cap Ply
(Notes 6,7,8) (Notes 6,7,8)
Min. 300 psi, min. 2-inch Celcore MF One or more layer(s), min. Min. 0.25-inch DensDeck (Optional)
Cellular Concrete with Celcore HS BP-AA, SBS- SBS-AA
Structural 1.5-inch ACFoam II, Prime or SECUROCK BP-AA, SBS-
LWC-37 Rheology Modifying Admixture; M-PG1 M-PG1 None AA, SBS-TA or APP- -240.0
concrete treated with Celcore PVA Curing ACFoam III, H-Shield or H- Gypsum-Fiber Roof AA, SBS-TA
or APP-TA TA
Compound Shield CG Board or APP-TA
Min. 300 psi, min. 2-inch Celcore MF
Cellular Concrete with Celcore HS One or more layer(s), min. Min. 0.25-inch DensDeck (Optional)
BP-AA, SBS- SBS-AA
Structural Rheology Modifying Admixture; 1.5-inch ACFoam II, Prime or SECUROCK BP-AA, SBS-
LWC-38 treated with Celcore PVA Curing
M-PG1 M-PG1 None AA, SBS-TA or APP- -232.5
concrete ACFoam III, H-Shield or H- Gypsum-Fiber Roof AA, SBS-TA
Compound and surfaced with Celcore or APP-TA TA
Shield CG Board or APP-TA
Sanded Bonding Surface (SBS)
One or more layer(s), min. BP-AA, (Optional)
Min. 300 psi Celcore MF Cellular Min. 0.25-inch SBS-AA
Structural 1.5-inch ACFoam II, SBS-AA, BP-AA, SBS-
LWC-39 Concrete with Celcore HS Rheology OB500 SECUROCK Gypsum-Fiber OB500 None or APP- -215.0
concrete Modifying Admixture ACFoam III, H-Shield or H- SBS-TA or AA, SBS-TA
Roof Board TA
Shield CG APP-TA or APP-TA
One or more layer(s), min. BP-AA, (Optional)
Min. 300 psi Celcore MF Cellular Min. 0.25-inch SBS-AA
Structural 1.5-inch ACFoam II, SBS-AA, BP-AA, SBS-
LWC-40 Concrete with Celcore HS Rheology Polyset BM SECUROCK Gypsum-Fiber Polyset BM None or APP- -215.0
concrete Modifying Admixture
ACFoam III, H-Shield or H- SBS-TA or AA, SBS-TA
Roof Board TA
Shield CG APP-TA or APP-TA
Min. 1-inch ENRGY 3, H- (Optional)
SBS-AA
Structural Min. 200 psi, min. 2-inch Celcore Shield or H-Shield CG or Min. 0.5-inch Structodek BP-AA or BP-AA, SBS-
LWC-41 Polyset CRA Polyset CRA None or APP- -180.0
concrete Cellular Concrete min. 1.5-inch Multi-Max High Density Fiberboard SBS-AA AA, SBS-TA
TA
FA3 or Ultra-Max or APP-TA
Min. 1-inch ENRGY 3, H- Min. 0.25-inch (Optional)
BP-AA, SBS- SBS-AA
Structural Min. 200 psi, min. 2-inch Celcore Shield or H-Shield CG or SECUROCK Gypsum-Fiber BP-AA, SBS-
LWC-42 Polyset CRA Polyset CRA None AA, SBS-TA or APP- -180.0
concrete Cellular Concrete min. 1.5-inch Multi-Max Roof Board or DensDeck AA, SBS-TA
or APP-TA TA
FA3 or Ultra-Max or DensDeck Prime or APP-TA
One or more layer(s), min. BP-AA, (Optional)
Min. 300 psi Celcore MF Cellular Min. 0.25-inch SBS-AA
Structural 1.5-inch ACFoam II, SBS-AA, BP-AA, SBS-
LWC-43 Concrete with Celcore HS Rheology Polyset CRA SECUROCK Gypsum-Fiber Polyset CRA None or APP- -215.0
concrete Modifying Admixture ACFoam III, H-Shield or H- SBS-TA or AA, SBS-TA
Roof Board TA
Shield CG APP-TA or APP-TA
ELASTIZELL (FL4994):
SELF-ADHERING SYSTEMS:
Structural Min. 200 psi, min. 2-inch Min. 1.5-inch ACFoam II or FlintPrime (Optional)
LWC-44 OB500 Min. 0.25-inch DensDeck OB500 SBS-SA SBS-SA -150.0
concrete Elastizell ENRGY 3 QD SBS-SA
Min. 0.25-inch
Structural Min. 200 psi, min. 2-inch Min. 1.5-inch ACFoam II, (Optional)
LWC-45 OB500 SECUROCK Gypsum-Fiber OB500 None SBS-SA SBS-SA -172.5
concrete Elastizell ENRGY 3 or H-Shield SBS-SA
Roof Board

NEMO ETC, LLC 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Evaluation Report 3520.03.04-R30 for FL2533-R29
Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 30: 01/26/2023
©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 46 of 74
NEMO|etc.
TABLE 4B: LIGHTWEIGHT CONCRETE OVER STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
Base Insulation Layer Coverboard Roof Cover (Note 15)
System Deck Lightweight Concrete MDP
No. (Note 1) (Note 14)
Attach Attach (psf)
Type Type Primer Base Ply Ply Cap Ply
(Notes 6,7,8) (Notes 6,7,8)
Min. 1-inch ENRGY 3, H-
Min. 0.25-inch
Structural Min. 200 psi, min. 2-inch Shield or H-Shield CG or (Optional)
LWC-46 Polyset CRA SECUROCK Gypsum-Fiber Polyset CRA None SBS-SA SBS-SA -172.5
concrete Elastizell min. 1.5-inch Multi-Max SBS-SA
Roof Board
FA3 or Ultra-Max
Min. 1-inch ENRGY 3, H-
Structural Min. 200 psi, min. 2-inch Shield or H-Shield CG or FlintPrime (Optional)
LWC-47 Polyset CRA Min. 0.25-inch DensDeck Polyset CRA SBS-SA SBS-SA -180.0
concrete Elastizell min. 1.5-inch Multi-Max QD SBS-SA
FA3 or Ultra-Max
CONVENTIONAL SYSTEMS:
(Optional)
BP-AA, SBS- SBS-AA
Structural Min. 200 psi, min. 2-inch Min. 0.25-inch DensDeck BP-AA, SBS-
LWC-48 Min. 1.5-inch ACFoam II OB500 OB500 None AA, SBS-TA or APP- -150.0
concrete Elastizell or DensDeck Prime AA, SBS-TA
or APP-TA TA
or APP-TA
BP-AA, (Optional)
Min. 0.25-inch SBS-AA
Structural Min. 200 psi, min. 2-inch Min. 2-inch ACFoam II, SBS-AA, BP-AA, SBS-
LWC-49 OB500 SECUROCK Gypsum-Fiber OB500 None or APP- -225.0
concrete Elastizell ENRGY 3 or H-Shield SBS-TA or AA, SBS-TA
Roof Board TA
APP-TA or APP-TA
Min. 1-inch ENRGY 3, H- (Optional)
SBS-AA
Structural Min. 200 psi, min. 2-inch Shield or H-Shield CG or Min. 0.5-inch Structodek BP-AA or BP-AA, SBS-
LWC-50 Polyset CRA Polyset CRA None or APP- -180.0
concrete Elastizell min. 1.5-inch Multi-Max High Density Fiberboard SBS-AA AA, SBS-TA
TA
FA3 or Ultra-Max or APP-TA
Min. 1-inch ENRGY 3, H- Min. 0.25-inch (Optional)
BP-AA, SBS- SBS-AA
Structural Min. 200 psi, min. 2-inch Shield or H-Shield CG or SECUROCK Gypsum-Fiber BP-AA, SBS-
LWC-51 Polyset CRA Polyset CRA None AA, SBS-TA or APP- -180.0
concrete Elastizell min. 1.5-inch Multi-Max Roof Board or DensDeck AA, SBS-TA
or APP-TA TA
FA3 or Ultra-Max or DensDeck Prime or APP-TA
COLD APPLIED SYSTEMS:
(Optional)
Structural Min. 350 psi, min 2-inch Elastizell OB500, 6- (Optional) Additional OB500, 6-inch BP-CA3 or
LWC-52 Min. 1.5-inch H-Shield CG None BP-CA3 or SBS-CA3 -60.0
concrete with Zell-Crete Fibers. inch o.c. layers of base insulation o.c. SBS-CA3
SBS-CA3
Min. 350 psi, min 2-inch Range II
Elastizell with Zell-Crete Fibers. When
(Optional)
Structural walkable, attach LWC with Trufast OB500, 6- (Optional) Additional OB500, 6-inch BP-CA3 or
LWC-53 #14HD with Trufast 3” Metal
Min. 1.5-inch H-Shield CG None BP-CA3 or SBS-CA3 -67.5
concrete inch o.c. layers of base insulation o.c. SBS-CA3
Insulation Plates at 1 per 8 ft2 through SBS-CA3
to the structural deck.

NEMO ETC, LLC 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Evaluation Report 3520.03.04-R30 for FL2533-R29
Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 30: 01/26/2023
©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 47 of 74
NEMO|etc.
TABLE 4C: LIGHTWEIGHT INSULATING CONCRETE OVER STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: LWC TO DECK, BONDED VAPOR BARRIER, BONDED INSULATION, BONDED ROOF COVER
Lightweight Base Insulation Layer Coverboard Roof Cover (Note 15)
System Deck MDP
Concrete Vapor Barrier Attach Attach Primer
No. (Note 1) Type Type Base Ply Ply Cap Ply (psf)
(Note 14) (Notes 6,7,8) (Notes 6,7,8)
PRE-EXISTENT CELLULAR LWC:
SELF-ADHERING SYSTEMS:
Flintlastic Ultra Poly SMS Base Sheet
Min. 400 psi, Min. 2- (Optional) 0.5-
applied in HB Fuller “Millennium
Min. 22 inch, pre-existent in. DensDeck
Hurricane Force Membrane Adhesive One or more layers,
cellular lightweight
ga., Type HS”, ribbons max. 6-inch o.c. 3-inch wide M-OSFA Prime or M-OSFA FlintPrime (Optional)
LWC-54 concrete, Repair
side laps and 6-inch wide end laps are
min. 2-inch ACFoam SBS-SA SBS-SA -67.5
BV, Grade LWC spalls with or M-PG1 SECUROCK or M-PG1 QD SBS-SA
hot-air-welded, torch-welded or sealed II or H-Shield
40 steel Celcore SBS (Sanded Gypsum-Fiber
with HB Fuller “Millennium Hurricane
Bonding Surface) Roof Board
Force Lap and Flashing Adhesive”
HYBRID SYSTEMS:
Flintlastic Ultra Poly SMS Base Sheet
Min. 400 psi, Min. 2- 0.5-in.
applied in HB Fuller “Millennium
Min. 22 inch, pre-existent DensDeck
Hurricane Force Membrane Adhesive One or more layers, (Optional) (Optional)
cellular lightweight
ga., Type HS”, ribbons max. 6-inch o.c. 3-inch wide M-OSFA Prime or M-OSFA
LWC-55 concrete, Repair
side laps and 6-inch wide end laps are
min. 2-inch ACFoam FlintPrime SBS-SA-H SBS-TA or APP-TA -67.5
BV, Grade LWC spalls with or M-PG1 SECUROCK or M-PG1
hot-air-welded, torch-welded or sealed II or H-Shield QD APP-TA
40 steel Celcore SBS (Sanded Gypsum-Fiber
with HB Fuller “Millennium Hurricane
Bonding Surface) Roof Board
Force Lap and Flashing Adhesive”
CONVENTIONAL SYSTEMS:
Flintlastic Ultra Poly SMS Base Sheet
Min. 400 psi, Min. 2- 0.5-in.
applied in HB Fuller “Millennium
Min. 22 inch, pre-existent DensDeck
Hurricane Force Membrane Adhesive One or more layers, (Optional) (Optional)
cellular lightweight
ga., Type HS”, ribbons max. 6-inch o.c. 3-inch wide M-OSFA Prime or M-OSFA SBS-TA or
LWC-56 concrete, Repair
side laps and 6-inch wide end laps are
min. 2-inch ACFoam FlintPrime SBS-TA or APP-TA -67.5
BV, Grade LWC spalls with or M-PG1 SECUROCK or M-PG1 APP-TA
hot-air-welded, torch-welded or sealed II or H-Shield QD APP-TA
40 steel Celcore SBS (Sanded Gypsum-Fiber
with HB Fuller “Millennium Hurricane
Bonding Surface) Roof Board
Force Lap and Flashing Adhesive”
ELASTIZELL (FL4994):
SELF-ADHERING SYSTEMS:
All Weather/Empire Base Sheet or
Flintglas MS Cap (inverted) applied in HB (Optional) 0.5-
Fuller “Millennium Hurricane Force in. DensDeck
One or more layers,
Structural Min. 420 psi, min. Membrane Adhesive HS”, ribbons max. 6- M-OSFA Prime or M-OSFA FlintPrime (Optional)
LWC-57 inch o.c., 3-inch wide side laps and 6-inch
min. 2-inch ACFoam SBS-SA SBS-SA -67.5
Concrete 2-inch Elastizell or M-PG1 SECUROCK or M-PG1 QD SBS-SA
wide end laps are sealed with HB Fuller II or H-Shield
Gypsum-Fiber
“Millennium Hurricane Force Lap and
Roof Board
Flashing Adhesive”

NEMO ETC, LLC 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Evaluation Report 3520.03.04-R30 for FL2533-R29
Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 30: 01/26/2023
©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 48 of 74
NEMO|etc.
TABLE 4C: LIGHTWEIGHT INSULATING CONCRETE OVER STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: LWC TO DECK, BONDED VAPOR BARRIER, BONDED INSULATION, BONDED ROOF COVER
Lightweight Base Insulation Layer Coverboard Roof Cover (Note 15)
System Deck MDP
Concrete Vapor Barrier Attach Attach Primer
No. (Note 1) Type Type Base Ply Ply Cap Ply (psf)
(Note 14) (Notes 6,7,8) (Notes 6,7,8)
Flintlastic Ultra Poly SMS Base Sheet
applied in HB Fuller “Millennium (Optional) 0.5-
Hurricane Force Membrane Adhesive in. DensDeck
One or more layers,
Structural Min. 420 psi, min. HS”, ribbons max. 6-inch o.c., 3-inch wide M-OSFA Prime or M-OSFA FlintPrime (Optional)
LWC-58 side laps and 6-inch wide end laps are
min. 2-inch ACFoam SBS-SA SBS-SA -67.5
Concrete 2-inch Elastizell or M-PG1 SECUROCK or M-PG1 QD SBS-SA
hot-air-welded, torch-welded or sealed II or H-Shield
Gypsum-Fiber
with HB Fuller “Millennium Hurricane
Roof Board
Force Lap and Flashing Adhesive”
HYBRID SYSTEMS:
All Weather/Empire Base Sheet or
Flintglas MS Cap (inverted) applied in HB 0.5-in.
Fuller “Millennium Hurricane Force DensDeck
One or more layers, (Optional) (Optional)
Structural Min. 420 psi, min. Membrane Adhesive HS”, ribbons max. 6- M-OSFA Prime or M-OSFA
LWC-59 inch o.c., 3-inch wide side laps and 6-inch
min. 2-inch ACFoam FlintPrime SBS-SA-H SBS-TA or APP-TA -67.5
Concrete 2-inch Elastizell or M-PG1 SECUROCK or M-PG1
wide end laps are sealed with HB Fuller II or H-Shield QD APP-TA
Gypsum-Fiber
“Millennium Hurricane Force Lap and
Roof Board
Flashing Adhesive”
Flintlastic Ultra Poly SMS Base Sheet
applied in HB Fuller “Millennium 0.5-in.
Hurricane Force Membrane Adhesive DensDeck
One or more layers, (Optional) (Optional)
Structural Min. 420 psi, min. HS”, ribbons max. 6-inch o.c., 3-inch wide M-OSFA Prime or M-OSFA
LWC-60 side laps and 6-inch wide end laps are
min. 2-inch ACFoam FlintPrime SBS-SA-H SBS-TA or APP-TA -67.5
Concrete 2-inch Elastizell or M-PG1 SECUROCK or M-PG1
hot-air-welded, torch-welded or sealed II or H-Shield QD APP-TA
Gypsum-Fiber
with HB Fuller “Millennium Hurricane
Roof Board
Force Lap and Flashing Adhesive”
CONVENTIONAL SYSTEMS:
All Weather/Empire Base Sheet or
Flintglas MS Cap (inverted) applied in HB 0.5-in.
Fuller “Millennium Hurricane Force DensDeck
One or more layers, (Optional) (Optional)
Structural Min. 420 psi, min. Membrane Adhesive HS”, ribbons max. 6- M-OSFA Prime or M-OSFA SBS-TA or
LWC-61 inch o.c., 3-inch wide side laps and 6-inch
min. 2-inch ACFoam FlintPrime SBS-TA or APP-TA -67.5
Concrete 2-inch Elastizell or M-PG1 SECUROCK or M-PG1 APP-TA
wide end laps are sealed with HB Fuller II or H-Shield QD APP-TA
Gypsum-Fiber
“Millennium Hurricane Force Lap and Roof Board
Flashing Adhesive”
Flintlastic Ultra Poly SMS Base Sheet
applied in HB Fuller “Millennium 0.5-in.
Hurricane Force Membrane Adhesive DensDeck
One or more layers, (Optional) (Optional)
Structural Min. 420 psi, min. HS”, ribbons max. 6-inch o.c., 3-inch wide M-OSFA Prime or M-OSFA SBS-TA or
LWC-62 side laps and 6-inch wide end laps are
min. 2-inch ACFoam FlintPrime SBS-TA or APP-TA -67.5
Concrete 2-inch Elastizell or M-PG1 SECUROCK or M-PG1 APP-TA
hot-air-welded, torch-welded or sealed II or H-Shield QD APP-TA
Gypsum-Fiber
with HB Fuller “Millennium Hurricane
Roof Board
Force Lap and Flashing Adhesive”

NEMO ETC, LLC 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Evaluation Report 3520.03.04-R30 for FL2533-R29
Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 30: 01/26/2023
©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 49 of 74
NEMO|etc.
TABLE 4D: LIGHTWEIGHT CONCRETE OVER STEEL DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER
Lightweight Concrete (Note 14) Anchor Sheet Insulation Roof Cover (Note 15)
System Deck MDP
Deck Surface Fasten
No. (Note 1) Type Type Attach Base Top Attach Base Ply Ply Cap Ply (psf)
Treatment Treatment (Note 11)
PRE-EXISTENT CELLULAR LWC:
SPOT- OR STRIP-MOPPED SYSTEMS:
9-inch o.c. at the
4-inch side lap
Min. 22 ga.
Min 350 psi, and 9-inch o.c. at
steel or Min. 1.5- BP-AA4, (Optional)
min 2-inch pre- Flintglas MS Cap Trufast Twin- two, equally (Optional) Additional Hot
structural None None inch 18-inch BP-AA, SBS- SBS-AA -60.0
LWC-63 existent (inverted) Loc Nails spaced, layers base insulation asphalt
concrete ACFoam II o.c. AA
cellular LWIC staggered rows in
deck.
the center of the
sheet
Note: To qualify the LWIC under this assembly, the subject fastener shall achieve an average withdrawal of 88 lbf when tested per ANSI/SPRI FX-1 or TAS 105.
CELCORE (FL2037):
SELF-ADHERING SYSTEMS:
Min. 470 psi,
min. 2-inch All 7-inch o.c. at the (Optional) Min. 0.25-
Min. 22 ga., Celcore MF Weather/Empire min. 4-inch side inch DensDeck Prime
Trufast FM-
type BV, Celcore S-1 Cellular Celcore PVA Base Sheet, laps and 7-inch or SECUROCK Gypsum-
90 Base Min. 1.5" hot (Optional)
LWC-64 Grade 40 Deck Concrete with Curing Glasbase Base o.c. at two, Fiber Roof Board. Top SBA-SA SBS-SA -60.0
Sheet ACFoam II asphalt SBS-SA
steel, 6 ft Preparation Celcore HS Compound Sheet or Flintlastic equally spaced, surface shall be
Fastener
span Rheology Base 20 or Flintglas staggered center primed with FlintPrime
Modifying MS Cap (inverted) rows QD.
Admixture
HYBRID SYSTEMS:
(Optional) Min. 0.125-
Min. 470 psi,
inch STURDY-DEK
min. 2-inch All 7-inch o.c. at the
Asphaltic Cover Board
Min. 22 ga., Celcore MF Weather/Empire min. 4-inch side
Trufast FM- or min. 0.25-inch (Optional)
type BV, Celcore S-1 Cellular Celcore PVA Base Sheet, laps and 7-inch SBS-AA
90 Base Min. 1.5" DensDeck Prime or hot SBS-AA,
LWC-65 Grade 40 Deck Concrete with Curing Glasbase Base o.c. at two, SBS-SA-H or APP- -60.0
Sheet ACFoam II SECUROCK Gypsum- asphalt SBS-TA or
steel, 6 ft Preparation Celcore HS Compound Sheet or Flintlastic equally spaced, TA
Fastener Fiber Roof Board. Top APP-TA
span Rheology Base 20 or Flintglas staggered center
surface may be
Modifying MS Cap (inverted) rows
optionally primed with
Admixture
FlintPrime QD.
CONVENTIONAL SYSTEMS:

NEMO ETC, LLC 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Evaluation Report 3520.03.04-R30 for FL2533-R29
Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 30: 01/26/2023
©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 50 of 74
NEMO|etc.
TABLE 4D: LIGHTWEIGHT CONCRETE OVER STEEL DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER
Lightweight Concrete (Note 14) Anchor Sheet Insulation Roof Cover (Note 15)
System Deck MDP
Deck Surface Fasten
No. (Note 1) Type Type Attach Base Top Attach Base Ply Ply Cap Ply (psf)
Treatment Treatment (Note 11)
Min. 0.125-inch
STURDY-DEK Asphaltic
Min. 470 psi,
Cover Board, min.
min. 2-inch All 7-inch o.c. at the
0.25-inch DensDeck
Min. 22 ga., Celcore MF Weather/Empire min. 4-inch side
Trufast FM- Prime or SECUROCK (Optional)
type BV, Celcore S-1 Cellular Celcore PVA Base Sheet, laps and 7-inch SBS-AA
90 Base Min. 1.5" Gypsum-Fiber Roof hot BP-AA or SBS-AA,
LWC-66 Grade 40 Deck Concrete with Curing Glasbase Base o.c. at two, or APP- -60.0
Sheet ACFoam II Board, min. 0.5-inch asphalt SBS-AA SBS-TA or
steel, 6 ft Preparation Celcore HS Compound Sheet or Flintlastic equally spaced, TA
Fastener Structodek High APP-TA
span Rheology Base 20 or Flintglas staggered center
Density Fiberboard
Modifying MS Cap (inverted) rows
Roof Insulation or min.
Admixture
0.75-inch Fesco Board
(homogeneous)
Min. 0.125-inch
Min. 470 psi,
STURDY-DEK Asphaltic
min. 2-inch All 7-inch o.c. at the
Cover Board or min.
Min. 22 ga., Celcore MF Weather/Empire min. 4-inch side
Trufast FM- 0.25-inch DensDeck
type BV, Celcore S-1 Cellular Celcore PVA Base Sheet, laps and 7-inch (Optional)
90 Base Min. 1.5" Prime or SECUROCK hot SBS-TA or
LWC-67 Grade 40 Deck Concrete with Curing Glasbase Base o.c. at two, SBS-TA or APP-TA -60.0
Sheet ACFoam II Gypsum-Fiber Roof asphalt APP-TA
steel, 6 ft Preparation Celcore HS Compound Sheet or Flintlastic equally spaced, APP-TA
Fastener Board. Top surface
span Rheology Base 20 or Flintglas staggered center
may be optionally
Modifying MS Cap (inverted) rows
primed with FlintPrime
Admixture
QD.
ELASTIZELL (FL4994):
SELF-ADHERING SYSTEMS:
All 7-inch o.c. at the (Optional) Min. 0.25-
Min. 22 ga., Min. 490 psi, Weather/Empire min. 4-inch side inch DensDeck Prime
Trufast FM-
type BV, min. 2-inch Base Sheet, laps and 7-inch or SECUROCK Gypsum-
90 Base Min. 1.5" hot (Optional)
LWC-68 Grade 40 None Elastizell with None Glasbase Base o.c. at two, Fiber Roof Board. Top SBA-SA SBS-SA -67.5
Sheet ACFoam II asphalt SBS-SA
steel, 6 ft Zell-Crete Sheet or Flintlastic equally spaced, surface shall be
Fastener
span Fibers Base 20 or Flintglas staggered center primed with FlintPrime
MS Cap (inverted) rows QD.
HYBRID SYSTEMS:
(Optional) Min. 0.125-
inch STURDY-DEK
All 7-inch o.c. at the
Asphaltic Cover Board
Min. 22 ga., Min. 490 psi, Weather/Empire min. 4-inch side
Trufast FM- or min. 0.25-inch (Optional)
type BV, min. 2-inch Base Sheet, laps and 7-inch SBS-AA
90 Base Min. 1.5" DensDeck Prime or hot SBS-AA,
LWC-69 Grade 40 None Elastizell with None Glasbase Base o.c. at two, SBS-SA-H or APP- -67.5
Sheet ACFoam II SECUROCK Gypsum- asphalt SBS-TA or
steel, 6 ft Zell-Crete Sheet or Flintlastic equally spaced, TA
Fastener Fiber Roof Board. Top APP-TA
span Fibers Base 20 or Flintglas staggered center
surface may be
MS Cap (inverted) rows
optionally primed with
FlintPrime QD.
CONVENTIONAL SYSTEMS:

NEMO ETC, LLC 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Evaluation Report 3520.03.04-R30 for FL2533-R29
Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 30: 01/26/2023
©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 51 of 74
NEMO|etc.
TABLE 4D: LIGHTWEIGHT CONCRETE OVER STEEL DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER
Lightweight Concrete (Note 14) Anchor Sheet Insulation Roof Cover (Note 15)
System Deck MDP
Deck Surface Fasten
No. (Note 1) Type Type Attach Base Top Attach Base Ply Ply Cap Ply (psf)
Treatment Treatment (Note 11)
Min. 0.125-inch
STURDY-DEK Asphaltic
Cover Board, min.
All 7-inch o.c. at the
0.25-inch DensDeck
Min. 22 ga., Min. 490 psi, Weather/Empire min. 4-inch side
Trufast FM- Prime or SECUROCK (Optional)
type BV, min. 2-inch Base Sheet, laps and 7-inch SBS-AA
90 Base Min. 1.5" Gypsum-Fiber Roof hot BP-AA or SBS-AA,
LWC-70 Grade 40 None Elastizell with None Glasbase Base o.c. at two, or APP- -67.5
Sheet ACFoam II Board, min. 0.5-inch asphalt SBS-AA SBS-TA or
steel, 6 ft Zell-Crete Sheet or Flintlastic equally spaced, TA
Fastener Structodek High APP-TA
span Fibers Base 20 or Flintglas staggered center
Density Fiberboard
MS Cap (inverted) rows
Roof Insulation or min.
0.75-inch Fesco Board
(homogeneous)
Min. 0.125-inch
STURDY-DEK Asphaltic
All 7-inch o.c. at the
Cover Board or min.
Min. 22 ga., Min. 490 psi, Weather/Empire min. 4-inch side
Trufast FM- 0.25-inch DensDeck
type BV, min. 2-inch Base Sheet, laps and 7-inch (Optional)
90 Base Min. 1.5" Prime or SECUROCK hot SBS-TA or
LWC-71 Grade 40 None Elastizell with None Glasbase Base o.c. at two, SBS-TA or APP-TA -67.5
Sheet ACFoam II Gypsum-Fiber Roof asphalt APP-TA
steel, 6 ft Zell-Crete Sheet or Flintlastic equally spaced, APP-TA
Fastener Board. Top surface
span Fibers Base 20 or Flintglas staggered center
may be optionally
MS Cap (inverted) rows
primed with FlintPrime
QD.
SPOT- OR STRIP-MOPPED SYSTEMS:
7-inch o.c. at the
4-inch side lap
Min. 22 ga.
Min 350 psi, and 7-inch o.c. at
steel or Trufast FM- Min. 1.5- BP-AA3, (Optional)
min 2-inch Flintglas MS Cap two, equally (Optional) Additional Hot
LWC-72 structural None None 90 Base Ply inch 18-inch BP-AA, SBS- SBS-AA -37.5*
Elastizell (inverted) spaced, layers base insulation asphalt
concrete Fastener ACFoam II grid AA
cellular LWIC staggered rows in
deck.
the center of the
sheet

NEMO ETC, LLC 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Evaluation Report 3520.03.04-R30 for FL2533-R29
Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 30: 01/26/2023
©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 52 of 74
NEMO|etc.
TABLE 4E: LIGHTWEIGHT CONCRETE DECKS OVER STEEL OR STRUCTURAL CONCRETE DECK – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE E-2: MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
Lightweight Concrete (Note 14) Base Sheet Roof Cover (Note 15)
System Deck MDP
No. (Note 1)
Deck Surface (psf)
LWC Type Fasten (Note 11) Attach Base Ply Cap Ply
Treatment Treatment
PRE-EXISTENT CELLULAR LIGHTWEIGHT CONCRETE:
SELF-ADHERING SYSTEMS:
Min. 22 ga., Type
Min. 300 psi, min. 2- 7-inch o.c. at the min. 2-inch lap and
BV, Grade 33 Trufast Twin Loc-
inch pre-existent 7-inch o.c. in two (2), equally
steel, 5 ft span or None None Flintlastic SA NailBase Nail Assembled SBS-SA SBS-SA -60.0
LWC-73 cellular lightweight spaced, staggered center rows,
structural Fastener (min. 1.8”)
insulating concrete. FlintPrime QD at stress plates
concrete
Note: To qualify the LWIC under this assembly, a 1.8-inch Trufast Twin Loc-Nail Assembled Fastener shall achieve an average withdrawal of 73 lbf when tested per ANSI/SPRI FX-1 or TAS 105
Min. 22 ga., Type
Min. 300 psi, min. 2- 9-inch o.c. at the min. 2-inch lap and
BV, Grade 33 Trufast Twin Loc-
inch pre-existent 9-inch o.c. in two (2), equally
steel, 5 ft span or None None Flintlastic SA NailBase Nail Assembled SBS-SA SBS-SA -60.0
LWC-74 cellular lightweight spaced, staggered center rows,
structural Fastener (min. 1.8”)
insulating concrete. FlintPrime QD at stress plates
concrete
Note: To qualify the LWIC under this assembly, a 1.8-inch Trufast Twin Loc-Nail Assembled Fastener shall achieve an average withdrawal of 93 lbf when tested per ANSI/SPRI FX-1 or TAS 105
HYBRID SYSTEMS:
Min. 22 ga., Type
Min. 300 psi, min. 2- Glasbase Base Sheet,
BV, Grade 33 Trufast Twin Loc- 9-inch o.c. at the 4-inch lap and 9- SBS-AA
inch pre-existent Flintlastic Base 20, All
steel, 5 ft span or None None Nail Assembled inch o.c. in two (2), equally spaced, SBS-SA-H or APP- -60.0
LWC-75 cellular lightweight Weather/Empire Base
structural Fastener (min. 1.8”) staggered center rows TA
insulating concrete. Sheet
concrete
Note: To qualify the LWIC under this assembly, a 1.8-inch Trufast Twin Loc-Nail Assembled Fastener shall achieve an average withdrawal of 88 lbf when tested per ANSI/SPRI FX-1 or TAS 105
Min. 22 ga., Type
Min. 350 psi, min. 3-
BV, Grade 33 Flintlastic Base 20 or 7-inch o.c. at the 4-inch lap and 10- SBS-AA
inch pre-existent Trufast FM-90 Base
steel, 5 ft span or None None Flintlastic Poly SMS Base inch o.c. in two (2), equally spaced, SBS-SA-H or APP- -67.5
LWC-76 cellular lightweight Sheet Fastener
structural Sheet staggered center rows TA
insulating concrete.
concrete
Note: To qualify the LWIC under this assembly, a 1.8-inch Trufast Twin Loc-Nail Assembled Fastener shall achieve an average withdrawal of 97 lbf when tested per ANSI/SPRI FX-1 or TAS 105
Min. 22 ga., Type
Min. 300 psi, min. 2-
BV, Grade 33 Flintlastic Poly SMS Base Trufast Twin Loc- 9-inch o.c. at the 4-inch lap and 9- SBS-AA
inch pre-existent
steel, 5 ft span or None None Sheet, Flintlastic Ultra Poly Nail Assembled inch o.c. in two (2), equally spaced, SBS-SA-H or APP- -75.0
LWC-77 cellular lightweight
structural SMS Base Sheet Fastener (min. 1.8”) staggered center rows TA
insulating concrete.
concrete
Note: To qualify the LWIC under this assembly, a 1.8-inch Trufast Twin Loc-Nail Assembled Fastener shall achieve an average withdrawal of 110 lbf when tested per ANSI/SPRI FX-1 or TAS 105
CONVENTIONAL SYSTEMS:

NEMO ETC, LLC 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Evaluation Report 3520.03.04-R30 for FL2533-R29
Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 30: 01/26/2023
©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 53 of 74
NEMO|etc.
TABLE 4E: LIGHTWEIGHT CONCRETE DECKS OVER STEEL OR STRUCTURAL CONCRETE DECK – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE E-2: MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
Lightweight Concrete (Note 14) Base Sheet Roof Cover (Note 15)
System Deck MDP
No. (Note 1)
Deck Surface (psf)
LWC Type Fasten (Note 11) Attach Base Ply Cap Ply
Treatment Treatment
Min. 22 ga., Type Glasbase Base Sheet,
Min. 300 psi, min. 2- (Optional)
BV, Grade 33 Flintlastic Base 20, All Trufast Twin Loc- 9-inch o.c. at the 4-inch lap and 9- SBS-AA
inch pre-existent BP-AA, SBS-
steel, 5 ft span or None None Weather/Empire Base Nail Assembled inch o.c. in two (2), equally spaced, or APP- -60.0
LWC-78 cellular lightweight AA, SBS-TA
structural Sheet or Flintglas MS Cap Fastener (min. 1.8”) staggered center rows TA
insulating concrete. or APP-TA
concrete (inverted)
Note: To qualify the LWIC under this assembly, a 1.8-inch Trufast Twin Loc-Nail Assembled Fastener shall achieve an average withdrawal of 88 lbf when tested per ANSI/SPRI FX-1 or TAS 105
Min. 22 ga., Type Glasbase Base Sheet,
Min. 300 psi, min. 2-
BV, Grade 33 Flintlastic Base 20, All Trufast Twin Loc- 7-inch o.c. at the 4-inch lap and 7- SBS-AA
inch pre-existent BP-AA or
steel, 5 ft span or None None Weather/Empire Base Nail Assembled inch o.c. in two (2), equally spaced, or APP- -67.5
LWC-79 cellular lightweight SBS-AA
structural Sheet or Flintglas MS Cap Fastener (min. 1.8”) staggered center rows TA
insulating concrete.
concrete (inverted)
Note: To qualify the LWIC under this assembly, a 1.8-inch Trufast Twin Loc-Nail Assembled Fastener shall achieve an average withdrawal of 77 lbf when tested per ANSI/SPRI FX-1 or TAS 105
Min. 22 ga., Type
Min. 350 psi, min. 3- Flintlastic Base 20,
BV, Grade 33 7-inch o.c. at the 4-inch lap and 10- BP-AA, SBS- SBS-AA
inch pre-existent Flintlastic Poly SMS Base Trufast FM-90 Base
steel, 5 ft span or None None inch o.c. in two (2), equally spaced, AA, SBS-TA or APP- -67.5
LWC-80 cellular lightweight Sheet or Flintglas MS Cap Sheet Fastener
structural staggered center rows or APP-TA TA
insulating concrete. (inverted)
concrete
Note: To qualify the LWIC under this assembly, a 1.8-inch Trufast Twin Loc-Nail Assembled Fastener shall achieve an average withdrawal of 97 lbf when tested per ANSI/SPRI FX-1 or TAS 105
Min. 22 ga., Type
Min. 300 psi, min. 2-
BV, Grade 33 Flintlastic Poly SMS Base Trufast Twin Loc- 9-inch o.c. at the 4-inch lap and 9- BP-AA, SBS- SBS-AA
inch pre-existent
steel, 5 ft span or None None Sheet, Flintlastic Ultra Poly Nail Assembled inch o.c. in two (2), equally spaced, AA, SBS-TA or APP- -75.0
LWC-81 cellular lightweight
structural SMS Base Sheet Fastener (min. 1.8”) staggered center rows or APP-TA TA
insulating concrete.
concrete
Note: To qualify the LWIC under this assembly, a 1.8-inch Trufast Twin Loc-Nail Assembled Fastener shall achieve an average withdrawal of 110 lbf when tested per ANSI/SPRI FX-1 or TAS 105
CELCORE (FL2037):
SELF-ADHERING SYSTEMS:
Min. 470 psi, min. 2-
Min. 22 ga., type Celcore S-1 inch Celcore MF Celcore 7-inch o.c. at the min. 4-inch side
Trufast FM-90 Base
LWC-82 BV, Grade 40 Deck Cellular Concrete with PVA Curing Flintlastic SA NailBase laps and 7-inch o.c. at two, equally SBS-SA SBS-SA -45.0
Sheet Fastener
steel, 6 ft span Preparation Celcore HS Rheology Compound spaced, staggered center rows
Modifying Admixture
HYBRID SYSTEMS:
Min. 470 psi, min. 2-
Min. 22 ga., type Celcore S-1 inch Celcore MF Celcore All Weather/Empire Base 7-inch o.c. at the min. 4-inch side SBS-AA
Trufast FM-90 Base
LWC-83 BV, Grade 40 Deck Cellular Concrete with PVA Curing Sheet, Glasbase Base Sheet laps and 7-inch o.c. at two, equally SBS-SA-H or APP- -45.0
Sheet Fastener
steel, 6 ft span Preparation Celcore HS Rheology Compound or Flintlastic Base 20 spaced, staggered center rows TA
Modifying Admixture

NEMO ETC, LLC 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Evaluation Report 3520.03.04-R30 for FL2533-R29
Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 30: 01/26/2023
©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 54 of 74
NEMO|etc.
TABLE 4E: LIGHTWEIGHT CONCRETE DECKS OVER STEEL OR STRUCTURAL CONCRETE DECK – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE E-2: MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
Lightweight Concrete (Note 14) Base Sheet Roof Cover (Note 15)
System Deck MDP
No. (Note 1)
Deck Surface (psf)
LWC Type Fasten (Note 11) Attach Base Ply Cap Ply
Treatment Treatment
Min. 470 psi, min. 2-
Min. 22 ga., type Celcore S-1 inch Celcore MF Celcore 7-inch o.c. at the min. 4-inch side SBS-AA
Flintglas MS Cap (inverted) Trufast FM-90 Base
LWC-84 BV, Grade 40 Deck Cellular Concrete with PVA Curing laps and 7-inch o.c. at two, equally SBS-SA-H or APP- -45.0
primed with FlintPrime QD Sheet Fastener
steel, 6 ft span Preparation Celcore HS Rheology Compound spaced, staggered center rows TA
Modifying Admixture
CONVENTIONAL SYSTEMS:
Min. 470 psi, min. 2-
All Weather/Empire Base (Optional)
Min. 22 ga., type Celcore S-1 inch Celcore MF Celcore 7-inch o.c. at the min. 4-inch side SBS-AA
Sheet, Glasbase Base Sheet Trufast FM-90 Base BP-AA, SBS-
LWC-85 BV, Grade 40 Deck Cellular Concrete with PVA Curing laps and 7-inch o.c. at two, equally or APP- -45.0
or Flintlastic Base 20 or Sheet Fastener AA, SBS-TA
steel, 6 ft span Preparation Celcore HS Rheology Compound spaced, staggered center rows TA
Flintglas MS Cap (inverted) or APP-TA
Modifying Admixture
Min. 22 ga., type Min. 300 psi, min 2-
All Weather/Empire Base (Optional)
B steel at max. 5 inch Celcore MF Celcore 9-inch o.c. at 4-inch laps and 12-inch
Sheet, Flintlastic Base 20, Trufast FM-90 Base BP-AA, SBS-
LWC-86 ft spans None Cellular Concrete with PVA Curing o.c. in two (2), equally spaced, SBS-AA -60.0
Flintlastic Poly SMS Base Sheet Fastener AA or SBS-
structural Celcore HS Rheology Compound staggered center rows
Sheet TA
concrete Modifying Admixture.
Glasbase Base Sheet,
Min. 22 ga., Type
Flintlastic Base 20, All
BV, Grade 33 Min. 300 psi, min 2- Celcore 7-inch o.c. at the 3-inch lap and 7- SBS-AA
Weather/Empire Base Trufast FM-90 Base BP-AA or
LWC-87 steel, 5 ft span or None inch Celcore Cellular PVA Curing inch o.c. in two (2), equally spaced, or APP- -75.0
Sheet, Flintlastic Poly SMS Sheet Fastener SBS-AA
structural Concrete. Compound staggered center rows TA
Base Sheet or Flintglas MS
concrete
Cap (inverted)
CONCRECEL (FL5584 & FL10500):
CONVENTIONAL SYSTEMS:
Glasbase Base Sheet,
Min. 22 ga., Type
Flintlastic Base 20, All
BV, Grade 33 Concrecel Min. 300 psi, min 2¼- Concrecel 7-inch o.c. at the 3-inch lap and 7- (Optional) SBS-AA
Weather/Empire Base OMG CR Base Ply
LWC-88 steel, 5 ft span or Bonding inch Concrecel Curing inch o.c. in two (2), equally spaced, BP-AA or or APP- -52.5
Sheet, Flintlastic Poly SMS Fastener (1.7)
structural Agent Concrete. Compound staggered center rows SBS-AA TA
Base Sheet or Flintglas MS
concrete
Cap (inverted)
ELASTIZELL (FL4994):
SELF-ADHERING SYSTEMS:
Min. 22 ga., type Min. 490 psi, min. 2- 7-inch o.c. at the min. 4-inch side
Trufast FM-90 Base
LWC-89 BV, Grade 40 None inch Elastizell with None Flintlastic SA NailBase laps and 7-inch o.c. at two, equally SBS-SA SBS-SA -45.0
Sheet Fastener
steel, 6 ft span Zell-Crete Fibers spaced, staggered center rows
HYBRID SYSTEMS:

NEMO ETC, LLC 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Evaluation Report 3520.03.04-R30 for FL2533-R29
Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 30: 01/26/2023
©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 55 of 74
NEMO|etc.
TABLE 4E: LIGHTWEIGHT CONCRETE DECKS OVER STEEL OR STRUCTURAL CONCRETE DECK – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE E-2: MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
Lightweight Concrete (Note 14) Base Sheet Roof Cover (Note 15)
System Deck MDP
No. (Note 1)
Deck Surface (psf)
LWC Type Fasten (Note 11) Attach Base Ply Cap Ply
Treatment Treatment
Glasbase Base Sheet, Trufast FM-90 Base
Min. 26 ga. steel
Flintlastic Base 20, All Sheet Fastener or 7½-inch o.c. at the 4-inch lap and SBS-AA
at max 5 ft spans Min. 200 psi, min 2-
LWC-90 None None Weather/Empire Base Trufast Twin Loc-Nail 7½-inch o.c. in two (2), equally SBS-SA-H or APP- -30.0
or structural inch Elastizell. Assembled Fastener
Sheet or Flintlastic Poly spaced, staggered center rows TA
concrete (1.8 inch)
SMS Base Sheet
Min. 22 ga., Type Glasbase Base Sheet, Trufast FM-90 Base
BV, Grade 33 Flintlastic Base 20, All Sheet Fastener or 7-inch o.c. at the 4-inch lap and 7- SBS-AA
Min. 200 psi, min 2-
LWC-91 steel, 5 ft span or None None Weather/Empire Base Trufast Twin Loc-Nail inch o.c. in two (2), equally spaced, SBS-SA-H or APP- -45.0
inch Elastizell. Assembled Fastener
structural Sheet or Flintlastic Poly staggered center rows TA
concrete SMS Base Sheet (1.8 inch)

Min. 22 ga., type Min. 490 psi, min. 2- All Weather/Empire Base 7-inch o.c. at the min. 4-inch side SBS-AA
Trufast FM-90 Base
LWC-92 BV, Grade 40 None inch Elastizell with None Sheet, Glasbase Base Sheet laps and 7-inch o.c. at two, equally SBS-SA-H or APP- -45.0
Sheet Fastener
steel, 6 ft span Zell-Crete Fibers or Flintlastic Base 20 spaced, staggered center rows TA
Min. 22 ga., type Min. 490 psi, min. 2- 7-inch o.c. at the min. 4-inch side SBS-AA
Flintglas MS Cap (inverted) Trufast FM-90 Base
LWC-93 BV, Grade 40 None inch Elastizell with None laps and 7-inch o.c. at two, equally SBS-SA-H or APP- -45.0
primed with FlintPrime QD Sheet Fastener
steel, 6 ft span Zell-Crete Fibers spaced, staggered center rows TA
CONVENTIONAL SYSTEMS:
Glasbase Base Sheet,
Min. 26 ga. steel Flintlastic Base 20, All Trufast FM-90 Base (Optional)
Sheet Fastener or 7½-inch o.c. at the 4-inch lap and SBS-AA
at max 5 ft spans Min. 200 psi, min 2- Weather/Empire Base BP-AA, SBS-
LWC-94 None None Trufast Twin Loc-Nail 7½-inch o.c. in two (2), equally or APP- -30.0
or structural inch Elastizell. Sheet, Flintlastic Poly SMS Assembled Fastener AA, SBS-TA
spaced, staggered center rows TA
concrete Base Sheet or Flintglas MS (1.8 inch) or APP-TA
Cap (inverted)
Min. 26 ga. steel
7½-inch o.c. at the 4-inch lap and
at max 5 ft spans Min. 200 psi, min 2- Trufast FM-90 Base (Optional)
LWC-95 None None Flintlastic APP Base T 7½-inch o.c. in two (2), equally APP-TA -30.0
or structural inch Elastizell. Sheet Fastener APP-TA
spaced, staggered center rows
concrete
All Weather/Empire Base (Optional)
Min. 22 ga., type Min. 490 psi, min. 2- 7-inch o.c. at the min. 4-inch side SBS-AA
Sheet, Glasbase Base Sheet Trufast FM-90 Base BP-AA, SBS-
LWC-96 BV, Grade 40 None inch Elastizell with None laps and 7-inch o.c. at two, equally or APP- -45.0
or Flintlastic Base 20 or Sheet Fastener AA, SBS-TA
steel, 6 ft span Zell-Crete Fibers spaced, staggered center rows TA
Flintglas MS Cap (inverted) or APP-TA
Glasbase Base Sheet,
Min. 22 ga., Type Trufast FM-90 Base
Flintlastic Base 20, All (Optional)
BV, Grade 33 Sheet Fastener or 7-inch o.c. at the 4-inch lap and 7- SBS-AA
Min. 200 psi, min 2- Weather/Empire Base BP-AA, SBS-
LWC-97 steel, 5 ft span or None None Trufast Twin Loc-Nail inch o.c. in two (2), equally spaced, or APP- -45.0
inch Elastizell. Sheet, Flintlastic Poly SMS Assembled Fastener AA, SBS-TA
structural staggered center rows TA
Base Sheet or Flintglas MS (1.8 inch) or APP-TA
concrete
Cap (inverted)

NEMO ETC, LLC 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Evaluation Report 3520.03.04-R30 for FL2533-R29
Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 30: 01/26/2023
©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 56 of 74
NEMO|etc.
TABLE 4E: LIGHTWEIGHT CONCRETE DECKS OVER STEEL OR STRUCTURAL CONCRETE DECK – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE E-2: MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
Lightweight Concrete (Note 14) Base Sheet Roof Cover (Note 15)
System Deck MDP
No. (Note 1)
Deck Surface (psf)
LWC Type Fasten (Note 11) Attach Base Ply Cap Ply
Treatment Treatment
Min. 22 ga., Type
BV, Grade 33 7-inch o.c. at the 4-inch lap and 7-
Min. 200 psi, min 2- Trufast FM-90 Base (Optional)
LWC-98 steel, 5 ft span or None None Flintlastic APP Base T inch o.c. in two (2), equally spaced, APP-TA -45.0
inch Elastizell. Sheet Fastener APP-TA
structural staggered center rows
concrete
COLD APPLIED SYSTEMS:
Min. 22 ga., Type
BV, Grade 33 Min. 350 psi, min 2- Flintlastic Base 20, 7-inch o.c. at the 4-inch lap and 7- (Optional)
Trufast FM-90 Base
LWC-99 steel, 5 ft span or None inch Range II Elastizell None Flintlastic Poly SMS Base inch o.c. in two (2), equally spaced, BP-CA2 or SBS-CA2 -45.0
Sheet Fastener
structural with Zell-Crete Fibers. Sheet staggered center rows SBS-CA2
concrete
Min. 22 ga., Type Min. 350 psi, min 2- Glasbase Base Sheet, 7-inch o.c. at the 4-inch lap and 7- (Optional)
Trufast FM-90 Base
LWC-100 BV, Grade 33 None inch Range II Elastizell None Flintlastic Poly SMS Base inch o.c. in two (2), equally spaced, BP-CA3 or SBS-CA3 -52.5
Sheet Fastener
steel, 5 ft span with Zell-Crete Fibers. Sheet staggered center rows SBS-CA3
Min. 350 psi, min 2- Glasbase Base Sheet, 7-inch o.c. at the 4-inch lap and 7- (Optional)
Structural Trufast FM-90 Base
LWC-101 None inch Range II Elastizell None Flintlastic Poly SMS Base inch o.c. in two (2), equally spaced, BP-CA3 or SBS-CA3 -60.0
concrete Sheet Fastener
with Zell-Crete Fibers. Sheet staggered center rows SBS-CA3
MEARLCRETE (FL13492):
CONVENTIONAL SYSTEMS:
Glasbase Base Sheet,
Min. 22 ga., Type
Flintlastic Base 20, All
BV, Grade 33 7-inch o.c. at the 4-inch lap and 7- (Optional) SBS-AA
Min. 250 psi, min 2- Weather/Empire Base OMG CR Base Ply
LWC-102 steel, 5 ft span or None None inch o.c. in two (2), equally spaced, BP-AA or or APP- -45.0
inch Mearlcrete. Sheet, Flintlastic Poly SMS Fastener (1.7)
structural staggered center rows SBS-AA TA
Base Sheet or Flintglas MS
concrete
Cap (inverted)
Min. 22 ga., Type
BV, Grade 33 7-inch o.c. at the 4-inch lap and 7- (Optional) SBS-AA
Min. 250 psi, min 2- Flintlastic Poly SMS Base OMG CR Base Ply
LWC-103 steel, 5 ft span or None None inch o.c. in two (2), equally spaced, BP-AA or or APP- -52.5
inch Mearlcrete. Sheet Fastener (1.7)
structural staggered center rows SBS-AA TA
concrete
Glasbase Base Sheet,
Min. 22 ga., Type
Flintlastic Base 20, All
BV, Grade 33 7-inch o.c. at the 4-inch lap and 7- (Optional) SBS-AA
Min. 300 psi, min 2- Weather/Empire Base OMG CR Base Ply
LWC-104 steel, 5 ft span or None None inch o.c. in two (2), equally spaced, BP-AA or or APP- -52.5
inch Mearlcrete. Sheet, Flintlastic Poly SMS Fastener (1.7)
structural staggered center rows SBS-AA TA
Base Sheet or Flintglas MS
concrete
Cap (inverted)

NEMO ETC, LLC 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Evaluation Report 3520.03.04-R30 for FL2533-R29
Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 30: 01/26/2023
©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 57 of 74
NEMO|etc.
TABLE 4F: LIGHTWEIGHT CONCRETE DECKS – REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE E: MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
System Lightweight Concrete (Note 14) Base Sheet Roof Cover (Note 15) MDP
Deck (Note 1)
No. Type Surfacing Base Fasten (Note 11) Spacing Base Ply Cap Ply (psf)
PRE-EXISTENT CELLULAR LWC:
Min. 470 psi, Min. 2- Trufast Versa Fastener
Min. 22 ga., For reroof (tear-off), repair Flintlastic Ultra 9-inch o.c. within the min. 5-
inch, pre-existent (min. 2.25”) & Plates, two (Optional) SBS-TA
Type BV, LWC spalls with Celcore SBS Poly SMS Base inch wide, heat-welded side APP-TA -75.0
cellular lightweight (2) screws per plate at or APP-TA
LWC-105 Grade 40 steel concrete
(Sanded Bonding Surface) Sheet
180° from each other*
laps

Note: *Field withdrawal resistance testing (Note 11) shall yield minimum 322 lbf. Additional Versa-Fast Fasteners within each Versa-Fast Plate may be utilized to produce minimum withdrawal
resistance. For recover installations, screws shall be of sufficient length for minimum 2.25” embedment into the existing LWC assembly.

TABLE 4G: LIGHTWEIGHT CONCRETE DECKS – REROOF (TEAR-OFF)


SYSTEM TYPE F: NON-INSULATED, BONDED ROOF COVER
System Lightweight Concrete (Note 14) Roof Cover (Note 15) MDP
Deck (Note 1)
No. Type Surfacing Base Ply Cap Ply (psf)
PRE-EXISTENT CELLULAR LWC:
Flintlastic Ultra Poly SMS Base Sheet applied in HB
Min. 400 psi, Min. 2- Repair LWC spalls Fuller “Millennium Hurricane Force Membrane
Min. 22 ga.,
inch, pre-existent with Celcore SBS Adhesive HS”, ribbons max. 6-inch o.c. 3-inch wide
LWC-106 Type BV, SBS-CA1 or SBS-CA4 -75.0
cellular lightweight (Sanded Bonding side laps and 6-inch wide end laps are hot-air-welded,
Grade 40 steel
concrete Surface) torch-welded or sealed with HB Fuller “Millennium
Hurricane Force Lap and Flashing Adhesive”
Flintlastic Ultra Poly SMS Base Sheet applied in HB Flintlastic FR-P, Flintlastic FR-P CoolStar, Flintlastic Premium FR-P, Flintlastic
Min. 400 psi, Min. 2- Repair LWC spalls Fuller “Millennium Hurricane Force Membrane Premium FR-P CoolStar, or Flintlastic GMS, applied in HB Fuller “Millennium
Min. 22 ga.,
inch, pre-existent with Celcore SBS Adhesive HS”, ribbons max. 6-inch o.c. 3-inch wide Hurricane Force Membrane Adhesive HS”, continuous ribbons maximum 6-
LWC-107 Type BV, -97.5
cellular lightweight (Sanded Bonding side laps and 6-inch wide end laps are hot-air-welded, inch o.c. 3-inch wide side laps and 6-inch wide end laps are hot-air-welded,
Grade 40 steel
concrete Surface) torch-welded or sealed with HB Fuller “Millennium torch-welded or sealed with HB Fuller “Millennium Hurricane Force Lap and
Hurricane Force Lap and Flashing Adhesive” Flashing Adhesive”

NEMO ETC, LLC 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Evaluation Report 3520.03.04-R30 for FL2533-R29
Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 30: 01/26/2023
©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 58 of 74
NEMO|etc.
TABLE 5A: CEMENTITIOUS WOOD FIBER DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
Base Insulation Layer Top Insulation Layer Roof Cover (Note 15)
System Deck MDP
Attach Attach Primer
No. (Notes 1, Note 12) Type Type Base Ply Ply Cap Ply (psf)
(Notes 6,7,8) (Notes 6,7,8)
SELF-ADHERING SYSTEMS:
(Optional) Additional layer(s) of base
Min. 1.5-inch ACFoam II or H- insulation and/or min. 0.25-inch DensDeck FlintPrime (Optional) SBS-
CWF-1. Tectum M-OSFA M-OSFA SBS-SA SBS-SA -60.0
Shield Prime or SECUROCK Gypsum-Fiber Roof QD SA
Board.
(Optional) Additional layer(s) of base
Min. 1.5-inch ACFoam II or H- M-OSFA, 6- insulation and/or min. 0.25-inch DensDeck M-OSFA, 6- FlintPrime (Optional) SBS-
CWF-2. Tectum SBS-SA SBS-SA -90.0
Shield inch o.c. Prime or SECUROCK Gypsum-Fiber Roof inch o.c. QD SA
Board.
Existing
Min. 1.5-inch ACFoam II, FlintPrime (Optional) SBS-
CWF-3. Tectum (re- OB500 Min. 0.25-inch DensDeck OB500 SBS-SA SBS-SA -45.0*
ENRGY 3 or Multi-Max FA3 QD SA
roof only)
Existing
Min. 1.5-inch ACFoam II, Min. 0.25-inch SECUROCK Gypsum-Fiber (Optional) SBS-
CWF-4. Tectum (re- OB500 OB500 None SBS-SA SBS-SA -45.0*
ENRGY 3 or Multi-Max FA3 Roof Board SA
roof only)
Min. 1-inch ENRGY 3, H-Shield Polyset BM
Polyset BM or FlintPrime (Optional) SBS-
CWF-5. Tectum or H-Shield CG or min. 1.5-inch Min. 0.25-inch DensDeck or Polyset SBS-SA SBS-SA -52.5
Polyset CRA QD SA
Multi-Max FA3 or Ultra-Max CRA
Min. 1-inch ENRGY 3, H-Shield Polyset BM
Polyset BM or Min. 0.25-inch SECUROCK Gypsum-Fiber (Optional) SBS-
CWF-6. Tectum or H-Shield CG or min. 1.5-inch or Polyset None SBS-SA SBS-SA -52.5
Polyset CRA Roof Board SA
Multi-Max FA3 or Ultra-Max CRA
HYBRID SYSTEMS:
(Optional) Additional layer(s) of base
(Optional) BP-
Min. 1.5-inch ACFoam II or H- insulation and/or min. 0.25-inch DensDeck SBS-AA or
CWF-7. Tectum M-OSFA M-OSFA None SBS-SA-H AA, SBS-AA, SBS- -60.0
Shield Prime or SECUROCK Gypsum-Fiber Roof APP-TA
TA or APP-TA
Board.
(Optional) Additional layer(s) of base
(Optional) BP-
Min. 1.5-inch ACFoam II or H- M-OSFA, 6- insulation and/or min. 0.25-inch DensDeck M-OSFA, 6- SBS-AA or
CWF-8. Tectum None SBS-SA-H AA, SBS-AA, SBS- -90.0
Shield inch o.c. Prime or SECUROCK Gypsum-Fiber Roof inch o.c. APP-TA
TA or APP-TA
Board.
CONVENTIONAL SYSTEMS:
Optional additional layers of base insulation, BP-AA, SBS- (Optional) BP-
Min. 1.5-inch ACFoam II or H- SBS-AA or
CWF-9. Tectum M-OSFA followed by min. 0.25-inch DensDeck Prime M-OSFA None AA, SBS-TA AA, SBS-AA, SBS- -60.0
Shield APP-TA
or SECUROCK Gypsum-Fiber Roof Board or APP-TA TA or APP-TA
Optional additional layers of base insulation, BP-AA, SBS- (Optional) BP-
Min. 1.5-inch ACFoam II or H- M-OSFA, 6- M-OSFA, 6- SBS-AA or
CWF-10. Tectum followed by min. 0.25-inch DensDeck Prime None AA, SBS-TA AA, SBS-AA, SBS- -90.0
Shield inch o.c. inch o.c. APP-TA
or SECUROCK Gypsum-Fiber Roof Board. or APP-TA TA or APP-TA

NEMO ETC, LLC 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Evaluation Report 3520.03.04-R30 for FL2533-R29
Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 30: 01/26/2023
©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 59 of 74
NEMO|etc.
TABLE 5A: CEMENTITIOUS WOOD FIBER DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
Base Insulation Layer Top Insulation Layer Roof Cover (Note 15)
System Deck MDP
Attach Attach Primer
No. (Notes 1, Note 12) Type Type Base Ply Ply Cap Ply (psf)
(Notes 6,7,8) (Notes 6,7,8)
Existing (Optional) BP-
Min. 1.5-inch ACFoam II, Min. 0.5-inch Structodek High Density BP-AA or SBS-AA or
CWF-11. Tectum (re- OB500 OB500 None AA, SBS-AA, SBS- -45.0*
ENRGY 3 or Multi-Max FA3 Fiberboard SBS-AA APP-TA
roof only) TA or APP-TA
Existing BP-AA, SBS- (Optional) BP-
Min. 1.5-inch ACFoam II, Min. 0.25-inch SECUROCK Gypsum-Fiber SBS-AA or
CWF-12. Tectum (re- OB500 OB500 None AA, SBS-TA AA, SBS-AA, SBS- -45.0*
ENRGY 3 or Multi-Max FA3 Roof Board or DensDeck or DensDeck Prime APP-TA
roof only) or APP-TA TA or APP-TA
Min. 1-inch ENRGY 3, H-Shield,
(Optional) BP-
or H-Shield CG, min. 1.3-inch Polyset BM or Min. 0.5-inch Structodek High Density BP-AA or SBS-AA or
CWF-13. Tectum Polyset CRA None AA, SBS-AA, SBS- -52.5
ACFoam III or min. 1.5-inch Polyset CRA Fiberboard SBS-AA APP-TA
TA or APP-TA
Multi-Max FA3 or Ultra-Max
Min. 1-inch ENRGY 3, H-Shield Polyset BM BP-AA, SBS- (Optional) BP-
Polyset BM or Min. 0.25-inch SECUROCK Gypsum-Fiber SBS-AA or
CWF-14. Tectum or H-Shield CG or min. 1.5-inch or Polyset None AA, SBS-TA AA, SBS-AA, SBS- -52.5
Polyset CRA Roof Board or DensDeck or DensDeck Prime APP-TA
Multi-Max FA3 or Ultra-Max CRA or APP-TA TA or APP-TA

NEMO ETC, LLC 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Evaluation Report 3520.03.04-R30 for FL2533-R29
Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 30: 01/26/2023
©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 60 of 74
NEMO|etc.
TABLE 5B: CEMENTITIOUS WOOF FIBER DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER
Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15)
System Deck Attach Attach MDP
No. (Note 1)
Fasten (psf)
Type Attach Type (Notes Type (Notes Base Ply Ply Cap Ply
(Note 11)
6,7,8) 6,7,8)
HYBRID SYSTEMS:
Glasbase Base Sheet, Trufast Twin 6-inch o.c. at the 4-
Min. 1.5-inch (Optional) Min. 0.25- (Optional)
Flintlastic Base 20, All Loc-Nail inch lap and 10-inch
ACFoam II, ENRGY hot inch SECUROCK hot SBS-AA, SBS-AA or
CWF-15. Tectum Weather/Empire Base Assembled o.c. in two (2), equally SBS-SA-H -60.0
3 or Multi-Max asphalt Gypsum-Fiber Roof asphalt SBS-TA or APP-TA
Sheet or Flintglas MS Fastener (Field spaced, staggered
FA3 Board APP-TA
Cap (inverted) W/D > 80 lbf) center rows
Glasbase Base Sheet, Trufast Twin 7-inch o.c. at the 4-
Min. 1.5-inch (Optional) Min. 0.25- (Optional)
Flintlastic Base 20, All Loc-Nail inch lap and 7-inch
ACFoam II, ENRGY hot inch SECUROCK hot SBS-AA, SBS-AA or
CWF-16. Tectum Weather/Empire Base Assembled o.c. in two (2), equally SBS-SA-H -60.0
3 or Multi-Max asphalt Gypsum-Fiber Roof asphalt SBS-TA or APP-TA
Sheet or Flintglas MS Fastener (Field spaced, staggered
FA3 Board APP-TA
Cap (inverted) W/D > 69 lbf) center rows
CONVENTIONAL SYSTEMS:
Glasbase Base Sheet, Trufast Twin 6-inch o.c. at the 4- Min. 0.75-inch
Min. 1.5-inch
Flintlastic Base 20, All Loc-Nail inch lap and 10-inch FescoBoard (Optional)
Existing ACFoam II, ENRGY hot hot BP-AA or SBS-AA or
CWF-17. Weather/Empire Base Assembled o.c. in two (2), equally (homogeneous) or min. BP-AA or -60.0
Tectum 3 or Multi-Max asphalt asphalt SBS-AA APP-TA
Sheet or Flintglas MS Fastener (Field spaced, staggered 0.5-inch Structodek SBS-AA
FA3
Cap (inverted) W/D > 80 lbf) center rows High Density Fiberboard
Glasbase Base Sheet, Trufast Twin 7-inch o.c. at the 4- Min. 0.75-inch
Min. 1.5-inch
Flintlastic Base 20, All Loc-Nail inch lap and 7-inch FescoBoard (Optional)
Existing ACFoam II, ENRGY hot hot BP-AA or SBS-AA or
CWF-18. Weather/Empire Base Assembled o.c. in two (2), equally (homogeneous) or min. BP-AA or -60.0
Tectum 3 or Multi-Max asphalt asphalt SBS-AA APP-TA
Sheet or Flintglas MS Fastener (Field spaced, staggered 0.5-inch Structodek SBS-AA
FA3
Cap (inverted) W/D > 69 lbf) center rows High Density Fiberboard

NEMO ETC, LLC 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Evaluation Report 3520.03.04-R30 for FL2533-R29
Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 30: 01/26/2023
©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 61 of 74
NEMO|etc.
TABLE 5C: CEMENTITIOUS WOOD FIBER DECKS – REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER
System Deck Base Insulation Layer(s) Top Insulation Layer Roof Cover (Note 15) MDP
No. (Note 1) (Note 3, Note 13) Type Fasten (Note 11) Attach Base Ply Ply Cap Ply (psf)
Min. 0.5-inch Structodek High OMG Polymer GypTec
Existing (Optional) One or more layers, 1 per 2.0 (Optional) BP-AA, SBS-AA, SBS-AA or
CWF-19. Density Fiberboard Roof with 3” GypTec Plate BP-AA or SBS-AA -45.0*
Tectum any combination, loose laid ft2 SBS-TA or APP-TA APP-TA
Insulation (Field W/D > 180 lbf)
OMG Polymer GypTec
Existing (Optional) One or more layers, Min. 0.25-inch DensDeck or 1 per 1.8 BP-AA, SBS-AA, SBS- (Optional) BP-AA, SBS-AA, SBS-AA or
CWF-20. with 3” GypTec Plate -45.0*
Tectum any combination, loose laid DensDeck Prime ft2 TA or APP-TA SBS-TA or APP-TA APP-TA
(Field W/D > 160 lbf)
Min. 0.5-inch Structodek High Trufast Twin Loc-Nail
Existing (Optional) One or more layers, 1 per 2.0 (Optional) BP-AA, SBS-AA, SBS-AA or
CWF-21. Density Fiberboard Roof Assembled Fastener (Field BP-AA or SBS-AA -45.0*
Tectum any combination, loose laid ft2 SBS-TA or APP-TA APP-TA
Insulation W/D > 180 lbf)
Min. 0.25-inch DensDeck or
Trufast Twin Loc-Nail
Existing (Optional) One or more layers, DensDeck Prime or 1 per 2.0 BP-AA, SBS-AA, SBS- (Optional) BP-AA, SBS-AA, SBS-AA or
CWF-22. Assembled Fastener (Field -45.0*
Tectum any combination, loose laid SECUROCK Gypsum-Fiber ft2 TA or APP-TA SBS-TA or APP-TA APP-TA
W/D > 180 lbf)
Roof Board

TABLE 5D: CEMENTITOUS WOOD FIBER DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) OR REROOF
SYSTEM TYPE E-2: MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
System Deck Base Sheet Roof Cover (Note 15) MDP
No. (Note 1) Base Fasten (Note 11) Attach Base Ply Cap Ply (psf)
SELF-ADHERING SYSTEMS:
Trufast Twin Loc-Nail Assembled 6-inch o.c. at the 4-inch lap and 10-inch o.c. in two
CWF-23. Tectum Flintlastic SA NailBase SBS-SA SBS-SA -60.0
Fastener (Field W/D > 80 lbf) (2), equally spaced, staggered center rows
Trufast Twin Loc-Nail Assembled 7-inch o.c. at the 4-inch lap and 7-inch o.c. in two
CWF-24. Tectum Flintlastic SA NailBase SBS-SA SBS-SA -60.0
Fastener (Field W/D > 69 lbf) (2), equally spaced, staggered center rows
CONVENTIONAL SYSTEMS:
Existing Trufast Insuldeck Loc-Nail Base
All Weather/Empire Base Sheet or Flintglas 9-inch o.c. at the 4-inch lap and 12-inch o.c. in two
CWF-25. Tectum Sheet Fastener (Field W/D > 53 BP-AA or SBS-AA SBS-AA -30.0*
MS Cap (inverted) (2), equally spaced, staggered center rows
(reroof only) lbf)
Existing Trufast Insuldeck Loc-Nail Base
All Weather/Empire Base Sheet or Flintglas 7½-inch o.c. at the 4-inch lap and 7½-inch o.c. in
CWF-26. Tectum Sheet Fastener (Field W/D > 55 BP-AA or SBS-AA SBS-AA -45.0*
MS Cap (inverted) two (2), equally spaced, staggered center rows
(reroof only) lbf)
Glasbase Base Sheet, Flintlastic Base 20, All
Trufast Twin Loc-Nail Assembled 6-inch o.c. at the 4-inch lap and 10-inch o.c. in two SBS-AA or APP-
CWF-27. Tectum Weather/Empire Base Sheet or Flintglas MS BP-AA or SBS-AA -60.0
Fastener (Field W/D > 80 lbf) (2), equally spaced, staggered center rows TA
Cap (inverted)
Glasbase Base Sheet, Flintlastic Base 20 or
Trufast Twin Loc-Nail Assembled 7-inch o.c. at the 4-inch lap and 7-inch o.c. in two SBS-AA or APP-
CWF-28. Tectum All Weather/Empire Base Sheet or Flintglas BP-AA or SBS-AA -67.5
Fastener (Field W/D > 77 lbf) (2), equally spaced, staggered center rows TA
MS Cap (inverted)

NEMO ETC, LLC 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Evaluation Report 3520.03.04-R30 for FL2533-R29
Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 30: 01/26/2023
©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 62 of 74
NEMO|etc.
TABLE 6A: GYPSUM DECKS – REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
Base Insulation Layer Top Insulation Layer Roof Cover (Note 15)
System Deck MDP
No. (Note 1, Note 12)
Attach Attach (psf)
Type Type Base Ply Ply Cap Ply
(Notes 6,7,8) (Notes 6,7,8)
SELF-ADHERING SYSTEMS:
Existing sound gypsum Min. 1.5-inch ACFoam II, ACFoam III, Min. 0.25-inch SECUROCK
G-1. M-OSFA M-OSFA SBS-SA (Optional) SBS-SA SBS-SA -172.5
or gypsum plank ENRGY 3, H-Shield or H-Shield CG Gypsum-Fiber Roof Board
Existing sound gypsum Min. 1.5-inch ACFoam II, ENRGY 3 or Min. 0.25-inch DensDeck
G-2. M-OSFA M-OSFA SBS-SA (Optional) SBS-SA SBS-SA -192.5
or gypsum plank Multi-Max FA3 primed with FlintPrime QD
One or more layer(s), min. 1.5-inch
Existing sound gypsum Min. 0.25-inch SECUROCK
G-3. ACFoam II, ACFoam III, H-Shield or H- M-PG1 M-PG1 SBS-SA (Optional) SBS-SA SBS-SA -172.5
or gypsum plank Gypsum-Fiber Roof Board
Shield CG
Existing sound gypsum Min. 0.25-inch DensDeck
G-4. Min. 1.5-inch ACFoam II or ENRGY 3 OB500 OB500 SBS-SA (Optional) SBS-SA SBS-SA -135.0
or gypsum plank primed with FlintPrime QD
One or more layer(s), min. 1.5-inch
Existing sound gypsum Min. 0.25-inch SECUROCK
G-5. ACFoam II, ACFoam III, H-Shield or H- OB500 OB500 SBS-SA (Optional) SBS-SA SBS-SA -172.5
or gypsum plank Gypsum-Fiber Roof Board
Shield CG
One or more layer(s), min. 1.5-inch
Existing sound gypsum Min. 0.25-inch SECUROCK
G-6. ACFoam II, ACFoam III, H-Shield or H- Polyset BM Polyset BM SBS-SA (Optional) SBS-SA SBS-SA -172.5
or gypsum plank Gypsum-Fiber Roof Board
Shield CG
One or more layer(s), min. 1-inch H-
Existing sound gypsum Shield or ENRGY 3, min. 1.3-inch Min. 0.25-inch SECUROCK
G-7. Polyset CRA Polyset CRA SBS-SA (Optional) SBS-SA SBS-SA -172.5
or gypsum plank ACFoam III or min. 1.5-inch ACFoam II, Gypsum-Fiber Roof Board
Multi-Max FA3 or Ultra-Max
min. 1-inch H-Shield or ENRGY 3, min.
Existing sound gypsum 1.3-inch ACFoam III or min. 1.5-inch Min. 0.25-inch DensDeck
G-8. Polyset CRA Polyset CRA SBS-SA (Optional) SBS-SA SBS-SA -192.5
or gypsum plank ACFoam II, Multi-Max FA3 or Ultra- primed with FlintPrime QD
Max
HYBRID SYSTEMS:
M-OSFA, M- M-OSFA, M-
One or more layer(s), min. 1.5-inch (Optional) Min. 0.25-inch
Existing sound gypsum PG1, OB500, PG1, OB500, (Optional) SBS-AA, SBS-AA or
G-9. ACFoam II, ACFoam III, H-Shield or H- SECUROCK Gypsum-Fiber SBS-SA-H -187.5
or gypsum plank Polyset BM, Polyset BM, SBS-TA or APP-TA APP-TA
Shield CG Roof Board
Polyset CRA Polyset CRA
CONVENTIONAL SYSTEMS:
(Optional) BP-AA,
Existing sound gypsum Min. 1.5-inch ACFoam II, ENRGY 3 or Min. 0.5-inch Structodek BP-AA or SBS- SBS-AA or
G-10. M-OSFA M-OSFA SBS-AA, SBS-TA or -127.5
or gypsum plank H-Shield High Density Fiberboard AA APP-TA
APP-TA
One or more layer(s), min. 1.5-inch BP-AA or SBS- (Optional) BP-AA,
Existing sound gypsum Min. 0.25-inch SECUROCK SBS-AA or
G-11. ACFoam II, ACFoam III, H-Shield or H- M-OSFA M-OSFA AA, SBS-TA or SBS-AA, SBS-TA or -187.5
or gypsum plank Gypsum-Fiber Roof Board APP-TA
Shield CG APP-TA APP-TA

NEMO ETC, LLC 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Evaluation Report 3520.03.04-R30 for FL2533-R29
Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 30: 01/26/2023
©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 63 of 74
NEMO|etc.
TABLE 6A: GYPSUM DECKS – REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
Base Insulation Layer Top Insulation Layer Roof Cover (Note 15)
System Deck MDP
No. (Note 1, Note 12)
Attach Attach (psf)
Type Type Base Ply Ply Cap Ply
(Notes 6,7,8) (Notes 6,7,8)
(Optional) BP-AA,
Existing sound gypsum Min. 1.5-inch ACFoam II, ENRGY 3 or BP-AA or SBS- SBS-AA or
G-12. M-OSFA Min. 0.25-inch DensDeck M-OSFA SBS-AA, SBS-TA or -232.5
or gypsum plank H-Shield AA APP-TA
APP-TA
BP-AA or SBS- (Optional) BP-AA,
Existing sound gypsum Min. 2-inch ACFoam II, ENRGY 3 or H- Min. 0.25-inch SECUROCK SBS-AA or
G-13. M-OSFA M-OSFA AA, SBS-TA or SBS-AA, SBS-TA or -202.5
or gypsum plank Shield Gypsum-Fiber Roof Board APP-TA
APP-TA APP-TA
One or more layer(s), min. 1.5-inch BP-AA or SBS- (Optional) BP-AA,
Existing sound gypsum Min. 0.25-inch SECUROCK SBS-AA or
G-14. ACFoam II, ACFoam III, H-Shield or H- M-PG1 M-PG1 AA, SBS-TA or SBS-AA, SBS-TA or -187.5
or gypsum plank Gypsum-Fiber Roof Board APP-TA
Shield CG APP-TA APP-TA
(Optional) BP-AA,
Existing sound gypsum Min. 1.5-inch ACFoam II, ENRGY 3 or Min. 0.5-inch Structodek BP-AA or SBS- SBS-AA or
G-15. OB500 OB500 SBS-AA, SBS-TA or -120.0
or gypsum plank H-Shield High Density Fiberboard AA APP-TA
APP-TA
Min. 0.25-inch DensDeck,
BP-AA, SBS- (Optional) BP-AA,
Existing sound gypsum Min. 1.5-inch ACFoam II, ENRGY 3 or DensDeck Prime or SBS-AA or
G-16. OB500 OB500 AA, SBS-TA or SBS-AA, SBS-TA or -135.0
or gypsum plank H-Shield SECUROCK Gypsum-Fiber APP-TA
APP-TA APP-TA
Roof Board
One or more layer(s), min. 1.5-inch BP-AA, SBS- (Optional) BP-AA,
Existing sound gypsum Min. 0.25-inch SECUROCK SBS-AA or
G-17. ACFoam II, ACFoam III, H-Shield or H- OB500 OB500 AA, SBS-TA or SBS-AA, SBS-TA or -187.5
or gypsum plank Gypsum-Fiber Roof Board APP-TA
Shield CG APP-TA APP-TA
One or more layer(s), min. 1.5-inch BP-AA, SBS- (Optional) BP-AA,
Existing sound gypsum Min. 0.25-inch SECUROCK SBS-AA or
G-18. ACFoam II, ACFoam III, H-Shield or H- Polyset BM Polyset BM AA, SBS-TA or SBS-AA, SBS-TA or -187.5
or gypsum plank Gypsum-Fiber Roof Board APP-TA
Shield CG APP-TA APP-TA
Min. 1-inch ENRGY 3, H-Shield or H- (Optional) BP-AA,
Existing sound gypsum Min. 0.5-inch Structodek BP-AA or SBS- SBS-AA or
G-19. Shield CG or min. 1.5-inch Multi-Max Polyset CRA Polyset CRA SBS-AA, SBS-TA or -180.0
or gypsum plank High Density Fiberboard AA APP-TA
FA3 or Ultra-Max APP-TA
One or more layer(s), min. 1.5-inch BP-AA, SBS- (Optional) BP-AA,
Existing sound gypsum Min. 0.25-inch SECUROCK SBS-AA or
G-20. ACFoam II, ACFoam III, H-Shield or H- Polyset CRA Polyset CRA AA, SBS-TA or SBS-AA, SBS-TA or -187.5
or gypsum plank Gypsum-Fiber Roof Board APP-TA
Shield CG APP-TA APP-TA
Min. 1-inch ENRGY 3, H-Shield or H- (Optional) BP-AA,
Existing sound gypsum Min. 0.25-inch SECUROCK BP-AA or SBS- SBS-AA or
G-21. Shield CG or min. 1.5-inch Multi-Max Polyset CRA Polyset CRA SBS-AA, SBS-TA or -225.0
or gypsum plank Gypsum-Fiber Roof Board AA APP-TA
FA3 or Ultra-Max APP-TA
Min. 1-inch ENRGY 3, H-Shield or H-
Existing sound gypsum Min. 0.25-inch SECUROCK SBS-TA or (Optional) SBS-TA
G-22. Shield CG or min. 1.5-inch Multi-Max Polyset CRA Polyset CRA APP-TA -232.5
or gypsum plank Gypsum-Fiber Roof Board APP-TA or APP-TA
FA3 or Ultra-Max
Min. 1-inch ENRGY 3, H-Shield or H- (Optional) BP-AA,
Existing sound gypsum BP-AA or SBS- SBS-AA or
G-23. Shield CG or min. 1.5-inch Multi-Max Polyset CRA Min. 0.25-inch DensDeck Polyset CRA SBS-AA, SBS-TA or -240.0
or gypsum plank AA APP-TA
FA3 or Ultra-Max APP-TA

NEMO ETC, LLC 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Evaluation Report 3520.03.04-R30 for FL2533-R29
Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 30: 01/26/2023
©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 64 of 74
NEMO|etc.
TABLE 6B: GYPSUM DECKS – REROOF (TEAR-OFF)
SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER
Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15)
System Deck Attach Attach MDP
No. (Note 1) Type Fasten (Note 11) Attach Type (Notes Type (Notes Base Ply Ply Cap Ply (psf)
6,7,8) 6,7,8)
HYBRID SYSTEMS:
Glasbase Base
6-inch o.c. at the
Sheet, Flintlastic
Trufast Twin Loc- 4-inch lap and 10- (Optional)
Existing sound Base 20, All Min. 1.5-inch
Nail Assembled inch o.c. in two (2), hot SBS-SA- SBS-AA, SBS-AA or
G-24. gypsum or Weather/Empire ACFoam II, ENRGY 3 None N/A -60.0
Fastener (Field equally spaced, asphalt H SBS-TA or APP-TA
gypsum plank Base Sheet or or Multi-Max FA3
W/D > 80 lbf) staggered center APP-TA
Flintglas MS Cap
rows
(inverted)
Glasbase Base
7-inch o.c. at the
Sheet, Flintlastic
Trufast Twin Loc- 4-inch lap and 7- (Optional)
Existing sound Base 20, All Min. 1.5-inch
Nail Assembled inch o.c. in two (2), hot SBS-SA- SBS-AA, SBS-AA or
G-25. gypsum or Weather/Empire ACFoam II, ENRGY 3 None N/A -60.0
Fastener (Field equally spaced, asphalt H SBS-TA or APP-TA
gypsum plank Base Sheet or or Multi-Max FA3
W/D > 69 lbf) staggered center APP-TA
Flintglas MS Cap
rows
(inverted)
CONVENTIONAL SYSTEMS:
Trufast FM-75 or 9-inch o.c. at the
Min. 0.75-inch
All Weather/Empire FM-90 Base Sheet 4-inch lap and 18- (Optional) Min. 1.5-
Existing sound FescoBoard (Optional)
Base Sheet or Fastener or Twin inch o.c. in two (2), inch ACFoam II, hot hot BP-AA or SBS-AA or
G-26. gypsum or (homogeneous) or min. BP-AA or -45.0*
Flintglas MS Cap Loc-Nail Assembled equally spaced, ENRGY 3 or Multi- asphalt asphalt SBS-AA APP-TA
gypsum plank 0.5-inch Structodek SBS-AA
(inverted) Fastener (Field staggered center Max FA3
High Density Fiberboard
W/D > 100 lbf) rows
Glasbase Base
6-inch o.c. at the
Sheet, Flintlastic Min. 0.75-inch
Trufast Twin Loc- 4-inch lap and 10-
Existing sound Base 20, All Min. 1.5-inch FescoBoard (Optional)
Nail Assembled inch o.c. in two (2), hot hot BP-AA or SBS-AA or
G-27. gypsum or Weather/Empire ACFoam II, ENRGY 3 (homogeneous) or min. BP-AA or -60.0
Fastener (Field equally spaced, asphalt asphalt SBS-AA APP-TA
gypsum plank Base Sheet or or Multi-Max FA3 0.5-inch Structodek SBS-AA
W/D > 80 lbf) staggered center
Flintglas MS Cap High Density Fiberboard
rows
(inverted)
Glasbase Base
7-inch o.c. at the
Sheet, Flintlastic Min. 0.75-inch
Trufast Twin Loc- 4-inch lap and 7-
Existing sound Base 20, All Min. 1.5-inch FescoBoard (Optional)
Nail Assembled inch o.c. in two (2), hot hot BP-AA or SBS-AA or
G-28. gypsum or Weather/Empire ACFoam II, ENRGY 3 (homogeneous) or min. BP-AA or -60.0
Fastener (Field equally spaced, asphalt asphalt SBS-AA APP-TA
gypsum plank Base Sheet or or Multi-Max FA3 0.5-inch Structodek SBS-AA
W/D > 69 lbf) staggered center
Flintglas MS Cap High Density Fiberboard
rows
(inverted)

NEMO ETC, LLC 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Evaluation Report 3520.03.04-R30 for FL2533-R29
Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 30: 01/26/2023
©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 65 of 74
NEMO|etc.
TABLE 6C: GYPSUM DECKS – REROOF (TEAR-OFF)
SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER
System Deck Base Insulation Layer(s) Top Insulation Layer Roof Cover (Note 15)
MDP (psf)
No. (Note 1) (Note 3, Note 13) Type Fasten (Note 11) Attach Base Ply Ply Cap Ply
Existing sound (Optional) One or more Min. 0.5-inch Structodek (Optional) BP-AA,
OMG Polymer GypTec with 3” BP-AA or SBS- SBS-AA or
G-29. gypsum or layers, any combination, High Density Fiberboard 1 per 2.0 ft2 SBS-AA, SBS-TA or -45.0*
GypTec Plate (Field W/D > 180 lbf) AA APP-TA
gypsum plank loose laid Roof Insulation APP-TA
Existing sound (Optional) One or more BP-AA, SBS- (Optional) BP-AA,
Min. 0.25-inch DensDeck or OMG Polymer GypTec with 3” SBS-AA or
G-30. gypsum or layers, any combination, 1 per 1.8 ft2 AA, SBS-TA or SBS-AA, SBS-TA or -45.0*
DensDeck Prime GypTec Plate (Field W/D > 160 lbf) APP-TA
gypsum plank loose laid APP-TA APP-TA
Existing sound (Optional) One or more Min. 0.5-inch Structodek (Optional) BP-AA,
Trufast Twin Loc-Nail Assembled BP-AA or SBS- SBS-AA or
G-31. gypsum or layers, any combination, High Density Fiberboard 1 per 2.0 ft2 SBS-AA, SBS-TA or -45.0*
Fastener (Field W/D > 180 lbf) AA APP-TA
gypsum plank loose laid Roof Insulation APP-TA
Min. 0.25-inch DensDeck or
Existing sound (Optional) One or more BP-AA, SBS- (Optional) BP-AA,
DensDeck Prime or Trufast Twin Loc-Nail Assembled SBS-AA or
G-32. gypsum or layers, any combination, 1 per 2.0 ft2 AA, SBS-TA or SBS-AA, SBS-TA or -45.0*
SECUROCK Gypsum-Fiber Fastener (Field W/D > 180 lbf) APP-TA
gypsum plank loose laid APP-TA APP-TA
Roof Board

TABLE 6D: GYPSUM DECKS – REROOF (TEAR-OFF)


SYSTEM TYPE E-2: MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
System Deck Base Sheet Roof Cover (Note 15) MDP
No. (Note 1) Base Fasten (Note 11) Attach Base Ply Cap Ply (psf)
SELF-ADHERING SYSTEMS:
Existing sound gypsum Trufast Twin Loc-Nail Assembled 6-inch o.c. at the 4-inch lap and 10-inch o.c. in two (2),
G-33. Flintlastic SA NailBase SBS-SA SBS-SA -60.0
or gypsum plank Fastener (Field W/D > 80 lbf) equally spaced, staggered center rows
Existing sound gypsum Trufast Twin Loc-Nail Assembled 9-inch o.c. at the 4-inch lap and 9-inch o.c. in two (2),
G-34. Flintlastic SA NailBase SBS-SA SBS-SA -60.0
or gypsum plank Fastener (Field W/D > 88 lbf) equally spaced, staggered center rows
CONVENTIONAL SYSTEMS:
Trufast FM-75 or FM-90 Base
Existing sound gypsum All Weather/Empire Base Sheet or Sheet Fastener or Twin Loc-Nail 9-inch o.c. at the 4-inch lap and 18-inch o.c. in two (2), BP-AA or SBS-
G-35. SBS-AA -45.0*
or gypsum plank Flintglas MS Cap (inverted) Assembled Fastener (Field W/D > equally spaced, staggered center rows AA
100 lbf)
Glasbase Base Sheet, Flintlastic
Existing sound gypsum Base 20, All Weather/Empire Base Trufast Twin Loc-Nail Assembled 6-inch o.c. at the 4-inch lap and 10-inch o.c. in two (2), BP-AA or SBS- SBS-AA or
G-36. -60.0
or gypsum plank Sheet or Flintglas MS Cap Fastener (Field W/D > 80 lbf) equally spaced, staggered center rows AA APP-TA
(inverted)
Glasbase Base Sheet, Flintlastic
Existing sound gypsum Base 20, All Weather/Empire Base Trufast Twin Loc-Nail Assembled 9-inch o.c. at the 4-inch lap and 9-inch o.c. in two (2), BP-AA or SBS- SBS-AA or
G-37. -67.5
or gypsum plank Sheet or Flintglas MS Cap Fastener (Field W/D > 100 lbf) equally spaced, staggered center rows AA APP-TA
(inverted)

NEMO ETC, LLC 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Evaluation Report 3520.03.04-R30 for FL2533-R29
Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 30: 01/26/2023
©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 66 of 74
NEMO|etc.
TABLE 7A: RECOVER APPLICATIONS
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
A
The reported MDP documents the allowable maximum design pressure of the new insulation and roof cover when installed atop the substrate, irrespective of the deck type (See Note 1) or performance of the substrate
(See Note 12). The deck and substrate shall be capable of resisting the project design pressure requirements, not to exceed the noted MDP, to the satisfaction of the Authority Having Jurisdiction.
Base Insulation Layer Top Insulation Layer Roof Cover (Note 15)
System MDP
Substrate (Note 1, Note 12) Attach Attach Primer
No. Type Type Base Ply Ply Cap Ply (psf)A
(Notes 6,7,8) (Notes 6,7,8)
SELF-ADHERING SYSTEMS:
(Optional) Min. 1.5-inch
Existing fully bonded BUR or modified FlintPrime (Optional)
R-1 ACFoam II, ENRGY 3, H- hot asphalt Min. 0.25-inch DensDeck hot asphalt SBS-SA SBS-SA -105.0
bitumen roof cover QD SBS-SA
Shield or Multi-Max FA3
(Optional) Min. 1.5-inch
Existing fully bonded BUR or modified Min. 0.25-inch SECUROCK (Optional)
R-2 ACFoam II, ENRGY 3, H- hot asphalt hot asphalt None SBS-SA SBS-SA -105.0
bitumen roof cover Gypsum-Fiber Roof Board SBS-SA
Shield or Multi-Max FA3
Existing fully-bonded smooth- or granule-
(Optional) Min. 1.5-inch M-OSFA or M- Min. 0.5-inch ACFoam-HD M-OSFA or FlintPrime (Optional)
R-3 surface asphalt BUR or SBS modified bitumen SBS-SA SBS-SA -97.5
ACFoam II or H-Shield PG1 Coverboard or H-Shield HD M-PG1 QD SBS-SA
or granule-surface APP modified bitumen
Existing fully-bonded smooth- or granule-
(Optional) Min. 1.5-inch M-OSFA or M- Min. 2-inch H-Shield HD M-OSFA or (Optional)
R-4 surface asphalt BUR or SBS modified bitumen None SBS-SA SBS-SA -142.5
ACFoam II or H-Shield PG1 Composite CG M-PG1 SBS-SA
or granule-surface APP modified bitumen
Existing fully-bonded smooth- or granule- (Optional) Min. 1.5-inch
M-OSFA or M- Min. 0.25-inch SECUROCK M-OSFA or (Optional)
R-5 surface asphalt BUR or SBS modified bitumen ACFoam II, ENRGY 3 or None SBS-SA SBS-SA -172.5
PG1 Gypsum-Fiber Roof Board M-PG1 SBS-SA
or granule-surface APP modified bitumen H-Shield
Existing fully-bonded smooth- or granule- (Optional) Min. 1.5-inch
M-OSFA or M- M-OSFA or FlintPrime (Optional)
R-6 surface asphalt BUR or SBS modified bitumen ACFoam II, ENRGY 3 or Min. 0.25-inch DensDeck SBS-SA SBS-SA -192.5
PG1 M-PG1 QD SBS-SA
or granule-surface APP modified bitumen Multi-Max FA3
Existing fully-bonded smooth- or granule- M-OSFA or M- M-OSFA or
(Optional) Min. 1.5-inch Min. 0.5-inch ACFoam-HD FlintPrime (Optional)
R-7 surface asphalt BUR or SBS modified bitumen PG1, 6-inch M-PG1, 6- SBS-SA SBS-SA -315.0
ACFoam II or H-Shield Coverboard or H-Shield HD QD SBS-SA
or granule-surface APP modified bitumen o.c. inch o.c.
Existing fully-bonded smooth- or granule- M-OSFA or M- M-OSFA or
(Optional) Min. 1.5-inch Min. 2-inch H-Shield HD (Optional)
R-8 surface asphalt BUR or SBS modified bitumen PG1, 6-inch M-PG1, 6- None SBS-SA SBS-SA -315.0
ACFoam II or H-Shield Composite CG SBS-SA
or granule-surface APP modified bitumen o.c. inch o.c.
Existing fully-bonded smooth- or granule- M-OSFA or M- M-OSFA or
(Optional) Min. 1.5-inch Min. 0.25-inch SECUROCK FlintPrime (Optional)
R-9 surface asphalt BUR or SBS modified bitumen PG1, 6-inch M-PG1, 6- SBS-SA SBS-SA -315.0
ACFoam II or H-Shield Gypsum-Fiber Roof Board QD SBS-SA
or granule-surface APP modified bitumen o.c. inch o.c.
Existing fully-bonded smooth- or granule-
(Optional) Min. 1.5-inch M-PG1-EF- M-PG1-EF- FlintPrime (Optional)
R-10 surface asphalt BUR or SBS modified bitumen Min. 0.5-inch H-Shield HD SBS-SA SBS-SA -97.5
ACFoam II or H-Shield ECO ECO QD SBS-SA
or granule-surface APP modified bitumen
Existing fully-bonded smooth- or granule-
(Optional) Min. 1.5-inch M-PG1-EF- Min. 2-inch H-Shield HD M-PG1-EF- (Optional)
R-11 surface asphalt BUR or SBS modified bitumen None SBS-SA SBS-SA -142.5
ACFoam II or H-Shield ECO Composite CG ECO SBS-SA
or granule-surface APP modified bitumen

NEMO ETC, LLC 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Evaluation Report 3520.03.04-R30 for FL2533-R29
Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 30: 01/26/2023
©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 67 of 74
NEMO|etc.
TABLE 7A: RECOVER APPLICATIONS
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
A
The reported MDP documents the allowable maximum design pressure of the new insulation and roof cover when installed atop the substrate, irrespective of the deck type (See Note 1) or performance of the substrate
(See Note 12). The deck and substrate shall be capable of resisting the project design pressure requirements, not to exceed the noted MDP, to the satisfaction of the Authority Having Jurisdiction.
Base Insulation Layer Top Insulation Layer Roof Cover (Note 15)
System MDP
Substrate (Note 1, Note 12) Attach Attach Primer
No. Type Type Base Ply Ply Cap Ply (psf)A
(Notes 6,7,8) (Notes 6,7,8)
Existing fully-bonded smooth- or granule- (Optional) Min. 1.5-inch
M-PG1-EF- Min. 0.25-inch SECUROCK M-PG1-EF- (Optional)
R-12 surface asphalt BUR or SBS modified bitumen ACFoam II, ENRGY 3 or None SBS-SA SBS-SA -172.5
ECO Gypsum-Fiber Roof Board ECO SBS-SA
or granule-surface APP modified bitumen H-Shield
Existing fully bonded BUR or modified (Optional) Min. 1.5-inch FlintPrime (Optional)
R-13 OB500 Min. 0.25-inch DensDeck OB500 SBS-SA SBS-SA -120.0
bitumen roof cover ACFoam II or ENRGY 3 QD SBS-SA
Existing fully bonded BUR or modified (Optional) Min. 1.5-inch Min. 0.25-inch SECUROCK (Optional)
R-14 OB500 OB500 None SBS-SA SBS-SA -120.0
bitumen roof cover ACFoam II or ENRGY 3 Gypsum-Fiber Roof Board SBS-SA
Existing fully-bonded smooth- or granule-
(Optional) Min. 1.5-inch Min. 0.25-inch SECUROCK (Optional)
R-15 surface asphalt BUR or granule-surface Polyset BM Polyset BM None SBS-SA SBS-SA -172.5
ACFoam II or H-Shield Gypsum-Fiber Roof Board SBS-SA
modified bitumen
Existing fully-bonded smooth- or granule-
(Optional) Min. 1.5-inch FlintPrime (Optional)
R-16 surface asphalt BUR or granule-surface Polyset BM Min. 0.25-inch DensDeck Polyset BM SBS-SA SBS-SA -192.5
ACFoam II or H-Shield QD SBS-SA
modified bitumen
Existing fully-bonded smooth- or granule-
(Optional) Min. 1.5-inch Min. 0.25-inch SECUROCK (Optional)
R-17 surface asphalt BUR or SBS modified bitumen Polyset CRA Polyset CRA None SBS-SA SBS-SA -172.5
ACFoam II or H-Shield Gypsum-Fiber Roof Board SBS-SA
or granule-surface APP modified bitumen
Existing fully-bonded smooth- or granule-
(Optional) Min. 1.5-inch FlintPrime (Optional)
R-18 surface asphalt BUR or SBS modified bitumen Polyset CRA Min. 0.25-inch DensDeck Polyset CRA SBS-SA SBS-SA -192.5
ACFoam II or H-Shield QD SBS-SA
or granule-surface APP modified bitumen
HYBRID SYSTEMS:
(Optional)
(Optional) Min. 1.5-inch SBS-AA,
Existing fully bonded BUR or modified Min. 0.25-inch SECUROCK SBS-AA,
R-19 ACFoam II, ENRGY 3, H- hot asphalt hot asphalt None SBS-SA-H SBS-TA, -105.0
bitumen roof cover Gypsum-Fiber Roof Board SBS-TA,
Shield or Multi-Max FA3 APP-TA
APP-TA
(Optional)
Existing fully-bonded smooth- or granule- SBS-AA,
(Optional) Min. 1.5-inch M-OSFA or M- Min. 0.5-inch ACFoam-HD M-OSFA or SBS-AA,
R-20 surface asphalt BUR or SBS modified bitumen None SBS-SA-H SBS-TA, -97.5
ACFoam II or H-Shield PG1 CoverBoard or H-Shield HD M-PG1 SBS-TA,
or granule-surface APP modified bitumen APP-TA
APP-TA
(Optional)
Existing fully-bonded smooth- or granule- SBS-AA,
(Optional) Min. 1.5-inch M-OSFA or M- Min. 2-inch H-Shield HD M-OSFA or SBS-AA,
R-21 surface asphalt BUR or SBS modified bitumen None SBS-SA-H SBS-TA, -142.5
ACFoam II or H-Shield PG1 Composite CG M-PG1 SBS-TA,
or granule-surface APP modified bitumen APP-TA
APP-TA

NEMO ETC, LLC 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Evaluation Report 3520.03.04-R30 for FL2533-R29
Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 30: 01/26/2023
©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 68 of 74
NEMO|etc.
TABLE 7A: RECOVER APPLICATIONS
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
A
The reported MDP documents the allowable maximum design pressure of the new insulation and roof cover when installed atop the substrate, irrespective of the deck type (See Note 1) or performance of the substrate
(See Note 12). The deck and substrate shall be capable of resisting the project design pressure requirements, not to exceed the noted MDP, to the satisfaction of the Authority Having Jurisdiction.
Base Insulation Layer Top Insulation Layer Roof Cover (Note 15)
System MDP
Substrate (Note 1, Note 12) Attach Attach Primer
No. Type Type Base Ply Ply Cap Ply (psf)A
(Notes 6,7,8) (Notes 6,7,8)
(Optional)
Existing fully-bonded smooth- or granule- SBS-AA,
(Optional) Min. 1.5-inch M-OSFA or M- (Optional) Additional M-OSFA or SBS-AA,
R-22 surface asphalt BUR or SBS modified bitumen None SBS-SA-H SBS-TA, -210.0
ACFoam II or H-Shield PG1 layer(s) base insulation M-PG1 SBS-TA,
or granule-surface APP modified bitumen APP-TA
APP-TA
(Optional)
Existing fully-bonded smooth- or granule- SBS-AA,
(Optional) Min. 1.5-inch M-OSFA or M- Min. 0.25-inch SECUROCK M-OSFA or SBS-AA,
R-23 surface asphalt BUR or SBS modified bitumen None SBS-SA-H SBS-TA, -210.0
ACFoam II or H-Shield PG1 Gypsum-Fiber Roof Board M-PG1 SBS-TA,
or granule-surface APP modified bitumen APP-TA
APP-TA
Min. 0.25-inch DensDeck
Prime or SECUROCK (Optional)
Existing fully-bonded smooth- or granule- M-OSFA or M- M-OSFA or SBS-AA,
(Optional) Min. 1.5-inch Gypsum-Fiber Roof Board SBS-AA,
R-24 surface asphalt BUR or SBS modified bitumen PG1, 6-inch M-PG1, 6- None SBS-SA-H SBS-TA, -315.0
ACFoam II or H-Shield or min. 0.5-inch ACFoam- SBS-TA,
or granule-surface APP modified bitumen o.c. inch o.c. APP-TA
HD CoverBoard or H-Shield APP-TA
HD
(Optional)
Existing fully-bonded smooth- or granule- M-OSFA or M- M-OSFA or SBS-AA,
(Optional) Min. 1.5-inch Min. 2-inch H-Shield HD SBS-AA,
R-25 surface asphalt BUR or SBS modified bitumen PG1, 6-inch M-PG1, 6- None SBS-SA-H SBS-TA, -315.0
ACFoam II or H-Shield Composite CG SBS-TA,
or granule-surface APP modified bitumen o.c. inch o.c. APP-TA
APP-TA
(Optional)
Existing fully-bonded smooth- or granule- SBS-AA,
(Optional) Min. 1.5-inch M-PG1-EF- M-PG1-EF- SBS-AA,
R-26 surface asphalt BUR or SBS modified bitumen Min. 0.5-inch H-Shield HD None SBS-SA-H SBS-TA, -97.5
ACFoam II or H-Shield ECO ECO SBS-TA,
or granule-surface APP modified bitumen APP-TA
APP-TA
(Optional)
Existing fully-bonded smooth- or granule- SBS-AA,
(Optional) Min. 1.5-inch M-PG1-EF- Min. 2-inch H-Shield HD M-PG1-EF- SBS-AA,
R-27 surface asphalt BUR or SBS modified bitumen None SBS-SA-H SBS-TA, -142.5
ACFoam II or H-Shield ECO Composite CG ECO SBS-TA,
or granule-surface APP modified bitumen APP-TA
APP-TA
(Optional)
Existing fully-bonded smooth- or granule- SBS-AA,
(Optional) Min. 1.5-inch M-PG1-EF- (Optional) Additional M-PG1-EF- SBS-AA,
R-28 surface asphalt BUR or SBS modified bitumen None SBS-SA-H SBS-TA, -210.0
ACFoam II or H-Shield ECO layer(s) base insulation ECO SBS-TA,
or granule-surface APP modified bitumen APP-TA
APP-TA
(Optional)
Existing fully-bonded smooth- or granule- SBS-AA,
(Optional) Min. 1.5-inch M-PG1-EF- Min. 0.25-inch SECUROCK M-PG1-EF- SBS-AA,
R-29 surface asphalt BUR or SBS modified bitumen None SBS-SA-H SBS-TA, -210.0
ACFoam II or H-Shield ECO Gypsum-Fiber Roof Board ECO SBS-TA,
or granule-surface APP modified bitumen APP-TA
APP-TA

NEMO ETC, LLC 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Evaluation Report 3520.03.04-R30 for FL2533-R29
Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 30: 01/26/2023
©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 69 of 74
NEMO|etc.
TABLE 7A: RECOVER APPLICATIONS
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
A
The reported MDP documents the allowable maximum design pressure of the new insulation and roof cover when installed atop the substrate, irrespective of the deck type (See Note 1) or performance of the substrate
(See Note 12). The deck and substrate shall be capable of resisting the project design pressure requirements, not to exceed the noted MDP, to the satisfaction of the Authority Having Jurisdiction.
Base Insulation Layer Top Insulation Layer Roof Cover (Note 15)
System MDP
Substrate (Note 1, Note 12) Attach Attach Primer
No. Type Type Base Ply Ply Cap Ply (psf)A
(Notes 6,7,8) (Notes 6,7,8)
(Optional)
SBS-AA,
Existing fully bonded, smooth- or granule- (Optional) Min. 1.5-inch Min. 0.25-inch SECUROCK SBS-AA,
R-30 OB500 OB500 None SBS-SA-H SBS-TA, -120.0
surface BUR or modified bitumen ACFoam II or ENRGY 3 Gypsum-Fiber Roof Board SBS-TA,
APP-TA
APP-TA
(Optional)
Existing fully-bonded smooth- or granule- SBS-AA,
(Optional) Min. 1.5-inch (Optional) Additional SBS-AA,
R-31 surface asphalt BUR or granule-surface Polyset BM Polyset BM None SBS-SA-H SBS-TA, -195.0
ACFoam II or H-Shield layer(s) base insulation SBS-TA,
modified bitumen APP-TA
APP-TA
(Optional)
Existing fully-bonded smooth- or granule- (Optional0 Min. 1.5- SBS-AA,
Min. 0.25-inch SECUROCK SBS-AA,
R-32 surface asphalt BUR or granule-surface inch ACFoam II or H- Polyset BM Polyset BM None SBS-SA-H SBS-TA, -195.0
Gypsum-Fiber Roof Board SBS-TA,
modified bitumen Shield APP-TA
APP-TA
(Optional)
Existing fully-bonded smooth- or granule- SBS-AA,
Min. 1.5-inch ACFoam II (Optional) Additional SBS-AA,
R-33 surface asphalt BUR or SBS modified bitumen Polyset CRA Polyset CRA None SBS-SA-H SBS-TA, -222.5
or H-Shield layer(s) base insulation SBS-TA,
or granule-surface APP modified bitumen APP-TA
APP-TA
(Optional)
Existing fully-bonded smooth- or granule- SBS-AA,
(Optional) Min. 1.5-inch Min. 0.25-inch SECUROCK SBS-AA,
R-34 surface asphalt BUR or SBS modified bitumen Polyset CRA Polyset CRA None SBS-SA-H SBS-TA, -217.5
ACFoam II or H-Shield Gypsum-Fiber Roof Board SBS-TA,
or granule-surface APP modified bitumen APP-TA
APP-TA
CONVENTIONAL SYSTEMS:
Min. 0.5-inch Structodek
High Density Fiberboard, (Optional)
(Optional) Min. 1.5-inch
Existing fully bonded BUR or modified Min. 0.75-inch FescoBoard BP-AA or BP-AA, SBS- SBS-AA or
R-35 ACFoam II, ENRGY 3, H- hot asphalt hot asphalt None -105.0
bitumen roof cover (homogeneous) or Min. SBS-AA AA, SBS-TA APP-TA
Shield or Multi-Max FA3
0.5-inch DuraBoard or APP-TA
(homogeneous)
0.25-inch DensDeck, BP-AA, (Optional)
(Optional) Min. 1.5-inch
Existing fully bonded BUR or modified DensDeck Prime or SBS-AA, BP-AA, SBS- SBS-AA or
R-36 ACFoam II, ENRGY 3, H- hot asphalt hot asphalt None -105.0
bitumen roof cover SECUROCK Gypsum-Fiber SBS-TA or AA, SBS-TA APP-TA
Shield or Multi-Max FA3
Roof Board APP-TA or APP-TA
(Optional)
Existing fully-bonded smooth- or granule- (Optional) Min. 1.5-inch
M-OSFA or M- Min. 0.5-inch Structodek M-OSFA or BP-AA or BP-AA, SBS- SBS-AA or
R-37 surface asphalt BUR or SBS modified bitumen ACFoam II, ENRGY 3 or None -165.0
PG1 High Density Fiberboard M-PG1 SBS-AA AA, SBS-TA APP-TA
or granule-surface APP modified bitumen H-Shield
or APP-TA

NEMO ETC, LLC 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Evaluation Report 3520.03.04-R30 for FL2533-R29
Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 30: 01/26/2023
©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 70 of 74
NEMO|etc.
TABLE 7A: RECOVER APPLICATIONS
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
A
The reported MDP documents the allowable maximum design pressure of the new insulation and roof cover when installed atop the substrate, irrespective of the deck type (See Note 1) or performance of the substrate
(See Note 12). The deck and substrate shall be capable of resisting the project design pressure requirements, not to exceed the noted MDP, to the satisfaction of the Authority Having Jurisdiction.
Base Insulation Layer Top Insulation Layer Roof Cover (Note 15)
System MDP
Substrate (Note 1, Note 12) Attach Attach Primer
No. Type Type Base Ply Ply Cap Ply (psf)A
(Notes 6,7,8) (Notes 6,7,8)
(Optional)
Existing fully-bonded smooth- or granule- (Optional) Min. 1.5-inch
M-OSFA or M- M-OSFA or BP-AA or BP-AA, SBS- SBS-AA or
R-38 surface asphalt BUR or SBS modified bitumen ACFoam II, ENRGY 3 or Min. 0.25-inch DensDeck None -210.0
PG1 M-PG1 SBS-AA AA, SBS-TA APP-TA
or granule-surface APP modified bitumen H-Shield
or APP-TA
(Optional)
Existing fully-bonded smooth- or granule- BP-AA,
(Optional) Min. 1.5-inch M-OSFA or M- Min. 0.25-inch DensDeck M-OSFA or BP-AA, SBS-
R-39 surface asphalt BUR or SBS modified bitumen None SBS-AA, SBS-AA -210.0
ACFoam II or H-Shield PG1 Prime M-PG1 AA or SBS-
or granule-surface APP modified bitumen SBS-TA
TA
BP-AA, (Optional)
Existing fully-bonded smooth- or granule- (Optional) Min. 2-inch
M-OSFA or M- Min. 0.25-inch SECUROCK M-OSFA or SBS-AA, BP-AA, SBS- SBS-AA or
R-40 surface asphalt BUR or SBS modified bitumen ACFoam II, ENRGY 3 or None -210.0
PG1 Gypsum-Fiber Roof Board M-PG1 SBS-TA or AA, SBS-TA APP-TA
or granule-surface APP modified bitumen H-Shield
APP-TA or APP-TA
Existing fully-bonded smooth- or granule- M-OSFA or M- Min. 0.25-inch DensDeck M-OSFA or (Optional)
(Optional) Min. 1.5-inch SBS-AA or
R-41 surface asphalt BUR or SBS modified bitumen PG1, 6-inch Prime or SECUROCK M-PG1, 6- None SBS-AA or SBS-AA -315.0
ACFoam II or H-Shield SBS-TA
or granule-surface APP modified bitumen o.c. Gypsum-Fiber Roof Board inch o.c. SBS-TA
Flintlastic
Existing fully-bonded smooth- or granule- M-OSFA or M- Min. 0.25-inch DensDeck M-OSFA or
(Optional) Min. 1.5-inch STA or (Optional)
R-42 surface asphalt BUR or SBS modified bitumen PG1, 6-inch Prime or SECUROCK M-PG1, 6- None APP-TA -315.0
ACFoam II or H-Shield Flintlastic APP-TA
or granule-surface APP modified bitumen o.c. Gypsum-Fiber Roof Board inch o.c.
STA Plus
(Optional)
Existing fully-bonded smooth- or granule- BP-AA,
(Optional) Min. 1.5-inch M-PG1-EF- Min. 0.25-inch DensDeck M-PG1-EF- BP-AA, SBS-
R-43 surface asphalt BUR or SBS modified bitumen None SBS-AA, SBS-AA -210.0
ACFoam II or H-Shield ECO Prime ECO AA or SBS-
or granule-surface APP modified bitumen SBS-TA
TA
BP-AA, (Optional)
Existing fully-bonded smooth- or granule- (Optional) Min. 2-inch
M-PG1-EF- Min. 0.25-inch SECUROCK M-PG1-EF- SBS-AA, BP-AA, SBS- SBS-AA or
R-44 surface asphalt BUR or SBS modified bitumen ACFoam II, ENRGY 3 or None -210.0
ECO Gypsum-Fiber Roof Board ECO SBS-TA or AA, SBS-TA APP-TA
or granule-surface APP modified bitumen H-Shield
APP-TA or APP-TA
(Optional)
(Optional) Min. 1.5-inch
Existing fully bonded BUR or modified Min. 0.5-inch Structodek BP-AA or BP-AA, SBS- SBS-AA or
R-45 ACFoam II, ENRGY 3 or OB500 OB500 None -120.0
bitumen roof cover High Density Fiberboard SBS-AA AA, SBS-TA APP-TA
H-Shield
or APP-TA
Min. 0.25-inch DensDeck, BP-AA, (Optional)
(Optional) Min. 1.5-inch
Existing fully bonded BUR or modified DensDeck Prime or SBS-AA, BP-AA, SBS- SBS-AA or
R-46 ACFoam II, ENRGY 3 or OB500 OB500 None -120.0
bitumen roof cover SECUROCK Gypsum-Fiber SBS-TA or AA, SBS-TA APP-TA
H-Shield
Roof Board APP-TA or APP-TA

NEMO ETC, LLC 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Evaluation Report 3520.03.04-R30 for FL2533-R29
Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 30: 01/26/2023
©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 71 of 74
NEMO|etc.
TABLE 7A: RECOVER APPLICATIONS
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
A
The reported MDP documents the allowable maximum design pressure of the new insulation and roof cover when installed atop the substrate, irrespective of the deck type (See Note 1) or performance of the substrate
(See Note 12). The deck and substrate shall be capable of resisting the project design pressure requirements, not to exceed the noted MDP, to the satisfaction of the Authority Having Jurisdiction.
Base Insulation Layer Top Insulation Layer Roof Cover (Note 15)
System MDP
Substrate (Note 1, Note 12) Attach Attach Primer
No. Type Type Base Ply Ply Cap Ply (psf)A
(Notes 6,7,8) (Notes 6,7,8)
(Optional)
Existing fully-bonded smooth- or granule-
(Optional) Min. 1.5-inch BP-AA or BP-AA, SBS- SBS-AA or
R-47 surface asphalt BUR or granule-surface Polyset BM Min. 0.25-inch DensDeck Polyset BM None -195.0
ACFoam II or H-Shield SBS-AA AA, SBS-TA APP-TA
modified bitumen
or APP-TA
BP-AA, (Optional)
Existing fully-bonded smooth- or granule-
(Optional) Min. 1.5-inch Min. 0.25-inch SECUROCK SBS-AA, BP-AA, SBS- SBS-AA or
R-48 surface asphalt BUR or granule-surface Polyset BM Polyset BM None -195.0
ACFoam II or H-Shield Gypsum-Fiber Roof Board SBS-TA or AA, SBS-TA APP-TA
modified bitumen
APP-TA or APP-TA
(Optional)
Existing fully-bonded smooth- or granule-
Min. 1.5-inch ACFoam II Min. 0.5-inch Structodek BP-AA or BP-AA, SBS- SBS-AA or
R-49 surface asphalt BUR or SBS modified bitumen Polyset CRA Polyset CRA None -180.0
or H-Shield High Density Fiberboard SBS-AA AA, SBS-TA APP-TA
or granule-surface APP modified bitumen
or APP-TA
(Optional)
Existing fully-bonded smooth- or granule-
(Optional) Min. 1.5-inch BP-AA or BP-AA, SBS- SBS-AA or
R-50 surface asphalt BUR or SBS modified bitumen Polyset CRA Min. 0.25-inch DensDeck Polyset CRA None -222.5
ACFoam II or H-Shield SBS-AA AA, SBS-TA APP-TA
or granule-surface APP modified bitumen
or APP-TA
BP-AA, (Optional)
Existing fully-bonded smooth- or granule-
(Optional) Min. 1.5-inch Min. 0.25-inch SECUROCK SBS-AA, BP-AA, SBS- SBS-AA or
R-51 surface asphalt BUR or SBS modified bitumen Polyset CRA Polyset CRA None -222.5
ACFoam II or H-Shield Gypsum-Fiber Roof Board SBS-TA or AA, SBS-TA APP-TA
or granule-surface APP modified bitumen
APP-TA or APP-TA
COLD-APPLIED SYSTEMS:
Existing fully-bonded smooth- or granule-
(Optional) Min. 1.5-inch M-OSFA or M- Min. 0.5-inch ACFoam-HD M-OSFA or
R-52 surface asphalt BUR or SBS modified bitumen None SBS-CA1 None SBS-CA1 -97.5
ACFoam II or H-Shield PG1 CoverBoard or H-Shield HD M-PG1
or granule-surface APP modified bitumen
Existing fully-bonded smooth- or granule-
(Optional) Min. 1.5-inch M-OSFA or M- Min. 0.5-inch ACFoam-HD M-OSFA or
R-53 surface asphalt BUR or SBS modified bitumen None SBS-CA4 None SBS-CA4 -97.5
ACFoam II or H-Shield PG1 CoverBoard or H-Shield HD M-PG1
or granule-surface APP modified bitumen
Existing fully-bonded smooth- or granule-
(Optional) Min. 1.5-inch M-OSFA or M- Min. 2-inch H-Shield HD M-OSFA or
R-54 surface asphalt BUR or SBS modified bitumen None SBS-CA4 None SBS-CA4 -97.5
ACFoam II or H-Shield PG1 Composite CG M-PG1
or granule-surface APP modified bitumen
Existing fully-bonded smooth- or granule-
(Optional) Min. 0.5-inch M-OSFA or M- Min. 0.25-inch SECUROCK M-OSFA or
R-55 surface asphalt BUR or SBS modified bitumen None SBS-CA1 None SBS-CA1 -105.0
ACFoam II or H-Shield PG1 Gypsum-Fiber Roof Board M-PG1
or granule-surface APP modified bitumen
Existing fully-bonded smooth- or granule-
(Optional) Min. 0.5-inch M-OSFA or M- Min. 0.25-inch SECUROCK M-OSFA or
R-56 surface asphalt BUR or SBS modified bitumen None SBS-CA4 None SBS-CA4 -105.0
ACFoam II or H-Shield PG1 Gypsum-Fiber Roof Board M-PG1
or granule-surface APP modified bitumen
NEMO ETC, LLC 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Evaluation Report 3520.03.04-R30 for FL2533-R29
Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 30: 01/26/2023
©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 72 of 74
NEMO|etc.
TABLE 7A: RECOVER APPLICATIONS
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
A
The reported MDP documents the allowable maximum design pressure of the new insulation and roof cover when installed atop the substrate, irrespective of the deck type (See Note 1) or performance of the substrate
(See Note 12). The deck and substrate shall be capable of resisting the project design pressure requirements, not to exceed the noted MDP, to the satisfaction of the Authority Having Jurisdiction.
Base Insulation Layer Top Insulation Layer Roof Cover (Note 15)
System MDP
Substrate (Note 1, Note 12) Attach Attach Primer
No. Type Type Base Ply Ply Cap Ply (psf)A
(Notes 6,7,8) (Notes 6,7,8)
Existing fully-bonded smooth- or granule-
(Optional) Min. 1.5-inch M-PG1-EF- M-PG1-EF-
R-57 surface asphalt BUR or SBS modified bitumen Min. 0.5-inch H-Shield HD None SBS-CA1 None SBS-CA1 -97.5
ACFoam II or H-Shield ECO ECO
or granule-surface APP modified bitumen
Existing fully-bonded smooth- or granule-
(Optional) Min. 1.5-inch M-PG1-EF- M-PG1-EF-
R-58 surface asphalt BUR or SBS modified bitumen Min. 0.5-inch H-Shield HD None SBS-CA4 None SBS-CA4 -97.5
ACFoam II or H-Shield ECO ECO
or granule-surface APP modified bitumen
Existing fully-bonded smooth- or granule-
(Optional) Min. 1.5-inch M-PG1-EF- Min. 2-inch H-Shield HD M-PG1-EF-
R-59 surface asphalt BUR or SBS modified bitumen None SBS-CA4 None SBS-CA4 -97.5
ACFoam II or H-Shield ECO Composite CG ECO
or granule-surface APP modified bitumen
Existing fully-bonded smooth- or granule-
(Optional) Min. 0.5-inch M-PG1-EF- Min. 0.25-inch SECUROCK M-PG1-EF-
R-60 surface asphalt BUR or SBS modified bitumen None SBS-CA1 None SBS-CA1 -105.0
ACFoam II or H-Shield ECO Gypsum-Fiber Roof Board ECO
or granule-surface APP modified bitumen
Existing fully-bonded smooth- or granule-
(Optional) Min. 0.5-inch M-PG1-EF- Min. 0.25-inch SECUROCK M-PG1-EF-
R-61 surface asphalt BUR or SBS modified bitumen None SBS-CA4 None SBS-CA4 -105.0
ACFoam II or H-Shield ECO Gypsum-Fiber Roof Board ECO
or granule-surface APP modified bitumen
Existing fully bonded BUR or modified (Optional) Min. 0.5-inch Min. 1.5-inch ACFoam III
R-62 OB500 OB500 None SBS-CA1 None SBS-CA1 -82.5
bitumen roof cover ACFoam II or H-Shield or H-Shield CG
Existing fully bonded, smooth- or granule- (Optional) Min. 0.5-inch Min. 0.25-inch SECUROCK
R-63 OB500 OB500 None SBS-CA1 None SBS-CA1 -105.0
surface BUR or modified bitumen ACFoam II or H-Shield Gypsum-Fiber Roof Board
Existing fully bonded, smooth- or granule- (Optional) Min. 0.5-inch Min. 0.25-inch SECUROCK
R-64 OB500 OB500 None SBS-CA4 None SBS-CA4 -105.0
surface BUR or modified bitumen ACFoam II or H-Shield Gypsum-Fiber Roof Board
Existing fully-bonded smooth- or granule-
(Optional) Min. 0.5-inch
R-65 surface asphalt BUR or granule-surface Polyset BM Min. 1.5-inch ACFoam III Polyset BM None SBS-CA1 None SBS-CA1 -82.5
ACFoam II or H-Shield
modified bitumen
Existing fully-bonded smooth- or granule-
(Optional) Min. 0.5-inch Min. 0.25-inch SECUROCK
R-66 surface asphalt BUR or granule-surface Polyset BM Polyset BM None SBS-CA1 None SBS-CA1 -105.0
ACFoam II or H-Shield Gypsum-Fiber Roof Board
modified bitumen
Existing fully-bonded smooth- or granule-
(Optional) Min. 0.5-inch Min. 0.25-inch SECUROCK
R-67 surface asphalt BUR or granule-surface Polyset BM Polyset BM None SBS-CA4 None SBS-CA4 -105.0
ACFoam II or H-Shield Gypsum-Fiber Roof Board
modified bitumen
Existing fully-bonded smooth- or granule-
(Optional) Min. 0.5-inch Min. 1.5-inch ACFoam III
R-68 surface asphalt BUR or SBS modified bitumen Polyset CRA Polyset CRA None SBS-CA1 None SBS-CA1 -82.5
ACFoam II or H-Shield or H-Shield CG
or granule-surface APP modified bitumen

NEMO ETC, LLC 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Evaluation Report 3520.03.04-R30 for FL2533-R29
Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 30: 01/26/2023
©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 73 of 74
NEMO|etc.
TABLE 7A: RECOVER APPLICATIONS
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
A
The reported MDP documents the allowable maximum design pressure of the new insulation and roof cover when installed atop the substrate, irrespective of the deck type (See Note 1) or performance of the substrate
(See Note 12). The deck and substrate shall be capable of resisting the project design pressure requirements, not to exceed the noted MDP, to the satisfaction of the Authority Having Jurisdiction.
Base Insulation Layer Top Insulation Layer Roof Cover (Note 15)
System MDP
Substrate (Note 1, Note 12) Attach Attach Primer
No. Type Type Base Ply Ply Cap Ply (psf)A
(Notes 6,7,8) (Notes 6,7,8)
Existing fully-bonded smooth- or granule-
(Optional) Min. 0.5-inch Min. 0.25-inch SECUROCK
R-69 surface asphalt BUR or SBS modified bitumen Polyset CRA Polyset CRA None SBS-CA1 None SBS-CA1 -105.0
ACFoam II or H-Shield Gypsum-Fiber Roof Board
or granule-surface APP modified bitumen
Existing fully-bonded smooth- or granule-
(Optional) Min. 0.5-inch Min. 0.25-inch SECUROCK
R-70 surface asphalt BUR or SBS modified bitumen Polyset CRA Polyset CRA None SBS-CA4 None SBS-CA4 -105.0
ACFoam II or H-Shield Gypsum-Fiber Roof Board
or granule-surface APP modified bitumen

TABLE 7B: RECOVER APPLICATIONS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)


SYSTEM TYPE F: NON-INSULATED, BONDED ROOF COVER
A
The reported MDP documents the allowable maximum design pressure of the new roof cover when installed atop the substrate, irrespective of the deck type (See Note 1) or performance of the substrate (See Note 12).
The deck and substrate shall be capable of resisting the project design pressure requirements, not to exceed the noted MDP, to the satisfaction of the Authority Having Jurisdiction.
System Substrate Roof Cover (Note 15) MDP
Primer
No. (Note 1, Note 12) Base Ply Ply Cap Ply (psf)A
R-71 Existing fully bonded asphalt built-up roof (BUR) (Optional) FlintPrime QD SBS-CA1 None SBS-CA1 -187.5

NEMO ETC, LLC 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Evaluation Report 3520.03.04-R30 for FL2533-R29
Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 30: 01/26/2023
©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 74 of 74