PER DWG.
SI.NO DESCRIPTION QTY I/U STATUS REMARKS
REQ. CODE
Ø 150 MM 1 EA
Ø 300 MM 1 EA
Ø 450 MM 1 EA
NOTES : 1. CONSTRUCTION CONTRACTOR SHALL VERIFY AND PROVIDE ALL QUANTITIES OF CONTRACTOR SUPPLIED MATERIAL REQUIRED
TO PERFORM THE WORK, AS DETAILED, ON THE CONSTRUCTION DRAWINGS. CONTRACTOR DRAWING NUMBER
SA016-01-5001-EN-1001
PER DWG.
SI.NO DESCRIPTION QTY I/U STATUS REMARKS
REQ. CODE
SHEET METAL, GALVANIZED: 0.55 MM THK. (GA.24) 1250 MM X 2500 MM LG, ASTM
13 A653M, COLD ROLLED, HOT-DIP-ZINC-COATED CHROMATED, OR CHEMICALLY 4.9 SM
PASSIVATED, NOT PHOSPATED, FLAT
SHEET METAL, STAINLESS STEEL: 0.02 MM THK., ASTM A653M, COLD ROLLED, HOT-
14 DIP-ZINC-COATED CHROMATED, OR CHEMICALLY PASSIVATED, NOT PHOSPATED, 10.77 SM
FLAT
SHEET METAL, GALVANIZED: 0.55 MM THK. (GA.24) 1250 MM X 2500 MM LG, ASTM
15 A653M, COLD ROLLED, HOT-DIP-ZINC-COATED CHROMATED, OR CHEMICALLY 152.15 SM
PASSIVATED, NOT PHOSPATED, FLAT
SHEET METAL, STAINLESS STEEL: 0.02 MM THK., ASTM A653M, COLD ROLLED, HOT-
16 DIP-ZINC-COATED CHROMATED, OR CHEMICALLY PASSIVATED, NOT PHOSPATED, 3.25 SM
FLAT
SHEET METAL, GALVANIZED: 0.70 MM THK. (GA.22) 1250 MM X 2500 MM LG, ASTM
17 A653M, COLD ROLLED, HOT-DIP-ZINC-COATED CHROMATED, OR CHEMICALLY 59.28 SM
PASSIVATED, NOT PHOSPATED, FLAT
INSULATION: FLEXIBLE BLANKET/ ROLL, 1.2M. WIDTH x 25MM THK. FIBERGLASS, 24
KG/M3 DENSITY, SURFACE BURNING CHARACTERISTICS, WHEN TESTED AS PER
18 ASTM 84/ NFPA 255/ UL 723 THE MAX. FLAME SPREAD INDEX/ SMOKE DEVELOPED 113.22 SM
INDEX RATING IS NOT MORE THAN 25/50 WITH REINFORCED ALUMINUM FOIL
VAPOR BARRIER
INSULATION: FLEXIBLE BLANKET/ ROLL, 1.2M. WIDTH x 50MM THK. FIBERGLASS, 48
KG/M3 DENSITY, SURFACE BURNING CHARACTERISTICS, WHEN TESTED AS PER
19 ASTM 84/ NFPA 255/ UL 723 THE MAX. FLAME SPREAD INDEX/ SMOKE DEVELOPED 108.06 SM
INDEX RATING IS NOT MORE THAN 25/50 WITH REINFORCED ALUMINUM FOIL
VAPOR BARRIER
AIR DUCT CLADDING: ALUMINUM SHEET, 0.4 MM THK, 900MM WIDTH x 2400MM
20 LENGTH, GR ALLOY 3003, ASTM - B209, NON-HEAT TREATABLE MODERATE 108.06 SM
STRENGTH, WELD ABLE AND HIGH CORROSION RESISTANT. (FOR OUTSIDE)
COPPER PIPES, TYPE "L" WITH 25MM THK,ARMAFLEX INSULATION AND DENSO
TAPE WRAPPING.
21 196 LM
7/8" DIA.-HOT GAS LINE
5/8" DIA.-LIQUID LINE
DRAIN PIPE : Ø 20 MM (3/4" Ø) SCH 40 PVC PIPE OR RTR PIPE WITH P-TRAP &
22 10 LM
ACCESSORIES FOR 01SAB90AH401 & 01SAB90AH402
DRAIN PIPE : Ø 25 MM (1" Ø) SCH 40 PVC PIPE OR RTR PIPE WITH P-TRAP &
23 1.6 LM
ACCESSORIES FOR 01SAB90AH301 & 01SAB90AH302
ANTI VIBRATION PAD: MOLDED IN NATURAL RUBBER FOR MAX. RESILIENCE AND
24 VIBRATION ISOLATION, STD. NEOPRENE FOR LONGER LIFE CROSS-RIBBED, STD. 12 EA
SIZE MODEL: USWP-300MM X 300MM X 19MM THK.
'ROD, THREADED: 10 MM (3/8 IN DIA), 1.8 M (6 FT) LG, STEEL BODY, GALV.
25 62 EA
FINISH, 20 THREAD /INCH HANGER WITH CONTINUOS THREAD
29 STRAPPING BAND: 0.51 MM (0.020 IN) THK, 19.1 MM (3/4 IN) WD, PVC, 31M / ROLL 1 LS
NOTES : 1. CONSTRUCTION CONTRACTOR SHALL VERIFY AND PROVIDE ALL QUANTITIES OF CONTRACTOR SUPPLIED MATERIAL REQUIRED
TO PERFORM THE WORK, AS DETAILED, ON THE CONSTRUCTION DRAWINGS. CONTRACTOR DRAWING NUMBER
SA016-01-5001-EN-1001