You are on page 1of 4

thickness

DL

C
Arch Dim.
L (m) = 4.8 t(m) = 0.2 Rise(m) = 0.16 Tread(m)= 0.3

h(story) = 1.8 Land Span 1 θ 25.34618

Material Properties Kn/m3


Tiles 22 Mortar 22 Conc. 25 Fc` = 30
0.02 0.03 Fy = 420
Calculating Load
γ∗((𝑅+𝑇+0.05)/𝑇)∗thick*1m kN/m
Tiles 0.748

kN/m
mortar γ∗((𝑅+𝑇)/𝑇)∗thick*1m 1.012

γ/𝑇∗((𝑅∗𝑇)/2)∗1m kN/m
stair step 2

((γ∗𝑡∗1)/𝑐𝑜𝑠θ) kN/m
Rein. Slab 5.532578

((γ∗𝑡∗1)/𝑐𝑜𝑠θ) kN/m
plaster 0.7303

Loads Sum → 10.02288 KN/m


LL 5 KN/m
Calculating Resultant Stresses
Wu = 1.2DL+1.6LL 20.02745 KN/m

Mu = 57.67907 KN.m Vu = 48.06589 KN


Check Shear
d 162 mm
ØVc = Ø 0.17 (fc)^.5 b d 113.1321 KN

(Ø𝑉𝑐 )/2
> Vu OK Shear

Flexure Design
0.85β.𝑓𝑐/𝑓𝑦.600/ → 7/)𝑓𝑐−28(∗0.85−0.05 0.835714
ρb = (600+𝑓𝑦) β=

ρb = 0.029847 ρmax = 0.022385 ρ = 0.011193

m = 𝑓𝑦/ 16.47059
0.85𝑓𝑐
Ru = ρ.fy.(1-0.5*ρ*m) 4.267591 Mpa

𝑀𝑢/(√
dcal = 122.5452 mm
)(Φ.𝐵.𝑅𝑢)

dcal < d Ok
𝑀𝑢/
Rurev = (0.9∗𝑏∗𝑑^2 ) 2.442 Mpa
𝑚./1
ρrev = (1−√(1−(2.𝑅𝑟𝑒𝑣.𝑚)/𝑓𝑦)) 0.006123

As = ρrev *b*d 991.9326 mm2


Asmin = 0.0018*b*h 360 mm2

N = As/Ab 5 bar

use ɸ 16 mm @ 200

Secondary Reinforcing
Asmin = 0.0018*b*h 360 mm2
N = As/Ab 4 bar

use ɸ 12 mm @ 250

Prepared by Eng. Mohammed Alhijazi Mohammed


Strucutral Engineer