You are on page 1of 2

Technical Service Bulletin

Title: TSB 20200518_EFL Water Purifier Flushing methods


Product/Model: WP – EFL Released Date: 18th May 2020
Prepared by: Mr. Saravanan. R Bulletin No: RESQ/TS/HA/2020 -09
Verified by: Mr. Shrikrishna R Version No: 1.0

Background:
In EFL Water Purifiers Filters flushing is very important during demo & installation other wise
product may damage or shows errors frequretly.

Purpose:
To communicate EFL models flushing methods during demo and installation.

Guideline:

➢ Filter flushing from externally without deassemble the filters. ( sediment / Pre corbon /
membrane & post corbon filters )

Flushing method No:1 ( Only sediment and pre corbon filters )

➢ Unit must be switched off condition


➢ Connect the tube through flushing hole and open the tap
➢ Now sediment and pre corbon filters are flushing out and water will come through flushing
line as per shown below Fig.
➢ Flushing duration > 5 Minuets without fail

Flushing method No:2 ( Only Membrane and post corbon filters )

➢ Unit must be switch on condition


➢ Connect the tube through flushing hole and open the tap
➢ Now membrane and post corbon filters are flushing out and water will come through
flushing line as per shown below Fig.
➢ Flushing duration > 5 Minuets without fail

1|Page Ver1.1
Pre carbon &
Sediment filters
flushing

Flushing
port in unit

Post carbon &


membrane filters
flushing

Note:
This flushing options is applicable for all Eureka Forbes models.
100 % Flushing is required while demo & Installation