You are on page 1of 13

Overburden Pressure on Cooler Foundation

Pipe Support foundation (FD1B) fouling with HP cooler foundation

Foundation FD1B
L = 1.7 m
B = 2 m
Considering 45-degree dispersion =
Dispersion depth = 0.7 m Dispersion size = 3.1 2.7
Dispersion Area = 8.37 m2
Maximum Bearing Pressure from Pipe FDN = 114.74 KN/m2 (Refer calc summary)

Dispersion Pressure = 46.609 KN/m2


Actual Baearing pressure (FD1B) = 114.74 KN/m2
Allowable bearing Pressure(FD1B) = 145 KN/m2

Actual Baearing pressure (F8) = 114.47 KN/m2


Allowable bearing Pressure(F8) = 155 KN/m2

Bearing presssure due to dispursion FD1B+Actual bearing pressure from Mat 3D 161.079

L1

B1

0.7

0.7

0.7
Overburden Pressure on Cooler Foundation

Pipe Support foundation (FD2) fouling with Cooler foundation

Foundation FD2
L = 3 m
B = 2.3 m
Considering 45-degree dispersion =
Dispersion depth = 1.349 m Dispersion size = 5.698 4.998
Dispersion Area = 28.478604 m2
Maximum Bearing Pressure from Pipe FDN = 78.8 KN/m2 (Refer calc summary)

Dispersion Pressure = 19.092 KN/m2

Overlap length ( L1) = 3m


Overlap width (B1) = 1.72 m
Equivalent Point load on Foundation = 19.092 Overlapping Area

= 98.516 KN

B1

L1`

1.35

1.35 3 1.35
5.67
Overburden Pressure on Existing foundation

Pipe Support foundation (FD3B) fouling with Existing foundation

Foundation FD3B
L 1.2 m
B 1.2 m
Considering 45-degree dispersion =
Dispersion depth = 0.2 m Dispersion size = 1.4 1.6
Dispersion Area = 2.24 m²
Maximum Bearing Pressure from Pipe FDN = 44.9 KN/m2 (Refer cal summary)

Dispersion Pressure from Shallow


Foundation F3B = 28.86 kN/m²

Actual Pressure From existing = 104.0 kN/m² Refer Foundation calculation


foundation summary

Allowable Pressure From Existing Refer Foundation calculation


= 187 kN/m² summary
foundation

= Actual Pressure From + Dispersion Pressure from


Actual Pressure From exsting existing foundation Shallow Foundation F3B
foundation

= 104.000 + 28.864

= 132.864 kN/m2

Actual Pressure = 132.864 kN/m² < 187 kN/m² Hence


Hencesafe
Safe.

L1
`
B1

0.2

0.2 1.2 0.2


1.4
Overburden Pressure on Existing foundation

Pipe Support foundation (FD5) fouling with Existing foundation

Foundation FD5
L 3.8 m
B 1 m
Considering 45-degree dispersion =
Dispersion depth = 0.2 m Dispersion size = 4 1.4
Dispersion Area = 5.6 m²
Maximum Bearing Pressure from Pipe FDN = 144 KN/m2 (Refer cal summary)

Dispersion Pressure from Shallow


Foundation F3A = 97.71 kN/m²

Actual Pressure From existing = 104.0 kN/m² Refer Foundation calculation


foundation summary

Allowable Pressure From Existing Refer Foundation calculation


= 187 kN/m² summary
foundation

= Actual Pressure From + Dispersion Pressure from


Actual Pressure From exsting existing foundation Shallow Foundation F3A
foundation

= 104.000 + 97.714

= 201.714 kN/m2

Actual Pressure = 201.714 kN/m² < 187 kN/m² UnHence


safe Safe.

L1
B1
`

0.2

0.2 3.8 0.2


4
Overburden Pressure on Existing foundation

Pipe Support foundation (FD3A) fouling with Existing foundation

Foundation FD3A
L 1.2 m
B 1.2 m
Considering 45-degree dispersion =
Dispersion depth = 0.2 m Dispersion size = 1.4 1.6
Dispersion Area = 2.24 m²
Maximum Bearing Pressure from Pipe FDN = 44.9 KN/m2 (Refer cal summary)

Dispersion Pressure from Shallow


Foundation F3A = 28.86 kN/m²

Actual Pressure From existing = 104.0 kN/m² Refer Foundation calculation


foundation summary

Allowable Pressure From Existing Refer Foundation calculation


= 187 kN/m² summary
foundation

= Actual Pressure From + Dispersion Pressure from


Actual Pressure From exsting existing foundation Shallow Foundation F3A
foundation

= 104.000 + 28.864

= 132.864 kN/m2

Actual Pressure = 132.864 kN/m² < 187 kN/m² Hence


Hencesafe
Safe.
L1

B1

0.2

0.2 1.2 0.2


1.4
Overburden Pressure on Cooler Foundation

Pipe Support foundation (FD3A) fouling with HP cooler foundation

Foundation FD3A
L = 1.2 m
B = 1.2 m
Considering 45-degree dispersion =
Dispersion depth = 0.2 m Dispersion size = 1.6 1.4
Dispersion Area = 2.24 m2
Maximum Bearing Pressure from Pipe FDN = 44.9 KN/m2 (Refer calc summary)

Dispersion Pressure = 28.864 KN/m2


Actual Baearing pressure (FD3A) = 44.9 KN/m2
Allowable bearing Pressure(FD3A) = 160.8 KN/m2

Actual Baearing pressure () = KN/m2


Allowable bearing Pressure() = KN/m2

Bearing presssure due to dispursion FD3A+Actual bearing pressure() 28.864

UNSAFE

L1

B1

0.2

0.2

0.2
Overburden Pressure on Cooler Foundation

Pipe Support foundation (FD5) fouling with HP cooler foundation

Foundation FD5
L = 3.8 m
B = 1 m
Considering 45-degree dispersion =
Dispersion depth = 0.2 m Dispersion size = 4.2 1.4
Dispersion Area = 5.88 m2
Maximum Bearing Pressure from Pipe FDN = 144 KN/m2 (Refer calc summary)

Dispersion Pressure = 93.061 KN/m2


Actual Baearing pressure (FD5) = 144 KN/m2
Allowable bearing Pressure(FD5) = 160.8 KN/m2

Actual Baearing pressure () = KN/m2


Allowable bearing Pressure() = KN/m2

Bearing presssure due to dispursion FD5+Actual bearing pressure() 93.061

UNSAFE

B1

L1

0.2

0.2

0.2

You might also like