You are on page 1of 4

1.

In case of fire: (Level 3)


A. Causing the fast release of a large amount of gas from the special core
material. This gas release very quickly increases the internal pressure to a
set value, makes the pressure-sensitive alarm switch inside the responder
closes
B. Causing the fast release of a large amount of gas from the special core
material. This gas release very quickly decrease the internal pressure to a
set value, makes the pressure-sensitive alarm switch inside the responder
closes
C. Causing the fast release of a large amount of gas from the special core
material. This gas release very quickly increases the internal pressure to a
set value, makes the pressure-sensitive alarm switch inside the responder
open
2. In case of the gas leakage: (Level 2)
A. The subsequent pressure increase, will cause the integrity switch to close,
signaling a fault malfunction to the flight deck
B. The subsequent pressure decrease, will cause the integrity switch to
close, signaling a fault malfunction to the flight deck
C. The subsequent pressure decrease, will cause the integrity switch to
open, signaling a fault malfunction to the flight deck
1. Each of Nacelle Anti-Ice Pressure Regulating Shutoff Valves (NAI PRSOV) can
be deactivated in _______ position according to MEL: (Level 2)
A. closed
B. open
C. either open or closed
1. How is the cross bleed valve controlled and operated? (Level 2)
A. Electrically controlled and pneumatically operated
B. Pneumatically controlled and operated
C. Electrically controlled and operate
2. IAW MEL, the aircraft can be dispatched with the defective High Pressure Valve
(HPV is deactivated in the following position: (Level 2)
A. Open.
B. Close.
C. Open or close depending on ice condition forecast during flight.
3. The OPV is: (Level 2)
A. Pneumatically operated, torque motor controlled and monitored by BMC.
B. Pneumatically operated, solenoid controlled and monitored by BMC.
C. Pneumatically operated.
4. IP Check Valve connect to: (Level 3)
A. HPC Stage HP3.
B. HPC Stage HP6.
C. LPC Stage LP2.

1. What is the purpose of Compressor Intermediate Case (CIC)? (Level 3)


A. Providing a flow path for engine core airflow coming from the LPC to the HPC
B. Providing a flow path for engine core airflow coming from the Fan Intermediate
Case (FIC) to the LPC
C. Neither A nor B
1. Where is P2.5/T2.5 probe locate? (Level 1)
A. On Compressor Intermediate Case at 1:00
B. On Compressor Intermediate Case at 6:00
C. On High-pressure Intermediate Case at 1:00
2. PMA (Permanent Magnet Alternator) is cooled by: (Level 2)
A. Fan air
B. 2.5 bleed air
C. Engine oil
3. Which component divides the fuel to primary and secondary manifold? (Level3)
A. Fuel Metering Valve.
B. Fuel Divider Valve.
C. Pressure Regulating Valve.
1. Is the purpose of the Active Clearance Control (ACC) system? (Level 3)
A. To improve compressor efficiency
B. To improve and maintain engine performance
C. To reduce overall engine thermal growth
2. The VVS (Variable Vanes System) actuators of LPC and HPC are : (Level 2)
A. Electrically controlled by EEC and actuated by servo fuel.
B. Electrically controlled by EEC and actuated by P3 pneumatic motive air.
C. Electrically controlled and actuated by EEC .
3. How to improve engine startup performance by the HPC Air System? (Level 3)
A. By 2.5 bleed air valve
B. By two HPC bleed valves
C. By three HPC bleed valve
4. What is the function of HPC bleed valves? (Level 3)
A. Allow HPC 6th Stage air to bleed directly into the core compartment during
engine start
B. Allow HPC 6th Stage air to bleed directly into fan flow during engine
start
C. Allow HPC 3rd Stage air to bleed directly into the core compartment
during engine start
5. What is the fail-safe mode of the ACC(Active Clearance Control) valve and actuator ?
(Level 3)
A. Closed
B. Full open
C. Partially open
6. The engine inlet cone is anti-iced with (Level 1)
A. Continuous airflow from the 2.5 compressor stage
B. Continuous airflow from the 3 compressor stage
C. Continuous airflow from the 6 compressor stage
7. No.4 bearing compartment is cooled and sealing by: (Level 1)
A. Buffer air (HPC 3rd stage air cooled by 2.5 bleed air)
B. Buffer air (HPC 3rd stage air cooled by fan air)
C. Buffer air (2.5 bleed air cooled by fan air)
1. What is the Fail Safe position of VORV? (Level 3)
A. Fully Open
B. Fully Close
C. 30% open
2. The No. 4 bearing magnetic chip collector is located (Level 1)
A. The lubrication and scavenge oil pump, at the 6 o'clock position..
B. In the No. 4 bearing oil scavenge line.
C. Exist in supply oil.
1. What is fail safe position of Starter Valve? (Level 3)
A. Fully closed.
B. Do not have fail safe position
C. Partition open