You are on page 1of 2

FORM NO.

: VFCRELF0009B
FCVN Lab
TEST LAB. REPORT
Application Based Reliability Test
REGION & MODEL NO. US & FH68010V TEST REQUESTED BY Daniel Pham Ngoc Dai
PROJECT NAME CW058 Power Scrub 2 Vietnam TEST REQUEST NO. FCVN-TR2210-016
SAMPLE CATEGORY Wet Extractor TESTED BY Jay Nguyen Nhat Minh
TEST QUANTITY 3 pcs TEST DATE 31-Oct-22
SAMPLE BUILD STAGE PP1 CHECKED BY Nguyen Si Duy
Mft Location/ OEM YDC VN Mfg. DATE CODE 2022 - 42th week - Thu
1. PURPOSE
1.1 To evaluate vacuum cleaner on an accellerated manner, reflicating normal use condition in average household.
1.2 As reference for improvement in Design, component reliability & production Assembly.
2. TEST PROCEDURE/ Other Test Descriptions or Special Instructions
FCTP-0500r : Application Based Reliability test for vacuum cleaner.
3. ACCEPTANCE CRITERIA
No Safety, reliability or functional issue during and after test. @Req'd. Test Flrs : 100 Floor 25 hrs
4. TEST SAMPLES DESCRIPTION/S
3 PP1 samples from YDC VN
5. TEST RESULTS
PASS MARGINAL PASS W/ Remarks>>
(With issues, could be a potential customer complaint )
FAIL REF. ONLY

6. TEST EQUIPMENT USED


Stop watch AC power supply Water Heater
Equipment/ ID#
FCVNLAB-0030 FCVNLAB-0027 FCVNLAB-0029

7. TEST CONSUMABLES

Item Test Materials/ Floor Qty Item Test Materials/ Floor Qty
1 Washed Play Sand 25 gms 8 Human Hair 0.12 gms
2 Potting Soil 10 gms 9 Dog Hair 0.12 gms
3 Banking Soda 25 gms 10 Polyfill 0.2 gms
TYPES OF FLOOR: - Plush Carpet - High Pile Shag - Level Loop/ Berber - Vinyl Floor - Ceramic Tile - HardFloor

8.Test conditions/power source


o
ROOM TEMP. & HUMIDITY : 25.0 C RH: 61.0 % POWER SOURCE : 120 V 60 Hz Power Supply
9. TEST DATA
A. DURING / AFTER ABR TEST
Carpet No.of Flrs.
Sample ID# Item Issue Desciption/ Observations Pictures
Type Found
High Pile 7,38,53,54,58 Pic.1
1 Water overflows into the motor air line Shag/ Vinyl ,62
Floor/ Level
#S1026221 Loop
Water leak in clean water tank Vinyl Floor 50 Pic.2
2
Change new water tank and continue testing
3 Stopped the test, No other issue. 100
High Pile 4,12,24,38,43 Refer to Pic.1
Shag/ Vinyl ,51,55,59
1 Water overflows into the motor air line
#S1026221 Floor/ Plush
Carpet
2 Stopped the test, No other issue. 100
Vinyl Floor/ 12,19,27,32,3 Refer to Pic.1
1 Water overflows into the motor air line
#S1026221 Level Loop 5,48,64
2 Stopped the test, No other issue. 100
B. DURING TEARDOWN
Sample ID# Item Issue List Description/ Observations Picture
1 Accumulation of debris/dust inside body housing Pic.3
2 Oxidized/rusted Suction Motor housing Pic.4
#S1026221
Motor function is normal
3
Motor: 29.39mm x 29.42mm
1 Accumulation of debris/dust inside body housing Refer to Pic.3
2 Oxidized/rusted Suction Motor housing Refer to Pic.4
#S1026222
Motor function is normal
3
Motor: 29.40mm x 29.43mm
1 Accumulation of debris/dust inside body housing Refer to Pic.3
Oxidized/rusted Suction Motor housing Pic.5
2
#S1026223 Debris Accumulated at the Motor Base area
Motor function is normal
3
Motor: 29.44mm x 29.42mm

10. PICTURE ILLUSTRATION

Pic.1 Pic.2 N/A

N/A

Pic.3

Pic.4 Pic.5

You might also like