ER-223 EMR 4 DS 22000 B1 4 of 25
CENTRIFUGAL PUMP DATASHEET
GENERAL
1 Note APPLICABLE TO: PROPOSAL APPLICABLE NATIONAL / INTERNATIONAL STANDARD : API-610 Rev
2 CLIENT UNIT 22
3 SITE SERVICE Cooling Water Pump
4 1 NO. REQ 1 (Motor) + 2 (Turbine) PUMP SIZE TYPE Centrifugal Horizontal No. STAGES
5 MANUFACTURER MODEL SERIAL NO.
6 EQUIPMENT NUMBER
7 LIQUID CHARACTERISTICS
8 Units @ RATED TEMP @ Normal TEMP @ MINIMUM TEMP @ Maximum TEMP Alternate LIQUID
9 LIQUID TYPE OR NAME : Cooling Water
10 PUMPING TEMPERATURE : °C 23.0 5.0 34 B1
11 VAPOR PRESSURE : bar a 0.053
12 RELATIVE DENSITY (3.1.53) : 0.9960
13 SPECIFIC HEAT : kJ/(kg-K) 4.234
14 VISCOSITY : mPa s 0.930
15
16 OPERATING CONDITIONS (6.1.3)
17 Alt Condition 1 Alt Condition 2 Alt Condition 3 Alt Condition 4
Units Rated Normal
18 {Name 1} {Name 2} {Name 3} {Name 4}
19 NPSHA Datum: C.L. Suction Nozzle
20 PUMPING TEMPERATURE : °C 23
21 FLOW : m³/h 7700.0 7000.0
22 2,3 DISCHARGE PRESSURE (6.3.2) : bar a 9.8 B1
23 2 SUCTION PRESSURE : bar a 1.10
24 2 DIFFERENTIAL PRESSURE : bar 8.70 B1
25 2 DIFFERENTIAL HEAD : m 89.13 B1
26 2 NPSHA : m 8.70 B1
27 2 HYDRAULIC POWER : kW 1810 B1
28 SITE AND UTILITY DATA B1
29 LOCATION: COOLING WATER
30 Under Shelter INLET RETURN DESIGN B1 °C
31 MOUNTED AT : TROPICALISATION REQD TEMP °C 23 MAX B1
32 ELECTRIC AREA CLASSIFICATION: 6.1.22 ZONE PRESS. Barg 7.5 MIN B1
33 GROUP TEMP CLASS SOURCE
34 SITE DATA :
35 ELEVATION (MSL) : 1685 m BAROMETER : 0.83 bara COOLING WATER CHLORIDE CONCENTRATION: <1200 ppm B1
36 RANGE OF AMBIENT TEMPS:MIN / MAX -21 / 43 °C B1
37 RELATIVE HUMIDITY: MIN / MAX 18 / 80 % INSTRUMENT AIR : MAX 6.2 barg Mechanical Design 10.3 barg B1
38 UNUSUAL CONDITIONS: Dust STEAM B1
39 DRIVERS HEATING
40 UTILITY CONDITIONS TEMP °C Max 360 B1
41 ELECTRICITY : DRIVERS HEATING CONTROL SHUTDOWN Min
42 VOLTAGE PRESS. barg Max 42.1 B1
43 PHASE Min 39 B1
44 PHASE
45
46 SERVICE (CONTINUOUS/INTERMITTENT) : CONTINUOUS INSTALLATION LOCATION : OUTDOOR
47 • IF INTERMITTENT, NO. OF STARTS : OUTDOOR, TEMPERATURE: MAX: 43 °C MIN: -21 °C
48 PUMPS OPERATE IN: PARALLEL ELECTRIC AREA CLASSIFICATION (6.1.29): NONHAZARDOUS
49 CORROSION DUE TO : (6.12.1.9) DIVISION Safe ZONE -
50 EROSION DUE TO : (6.12.1.9) GROUP -
51 H2S CONCENTRATION (ppm) : (6.12.1.13) No TEMP CLASS -
52 CHLORIDE CONCENTRATION (ppm) : <1200 PUMP VALVE START POSITION : Partially Open Valve B1
53 PARTICULATE SIZE (DIA IN MICRONS) UNUSUAL CONDITION Dust
54 PARTICULATE CONCENTRATION (ppm)
55 CORROSION ALLOWANCE (6.3.10) :
56 FLUID IS HAZARDOUS OR NOT? No
57 LEAKAGE TO ATMOSPHERE IS ALLOWED OR NOT? Yes
58 IF CONTAMINATION OF FLUID IS ALLOWED OR NOT? No
59 ATMOSPHERIC BOILING POINT?
60 FLUID SOLID @ AMBIENT OR NOT?
61 POUR POINT TEMP? -
62 IF FLUID IS CRYSTALLIZING OR IF THERE IS POSSIBILITY OF COKE FORMATION IN PRESENCE OF OXYGEN? No
63 FLAMMABLE OR NOT? No
64 OTHER
65 PERFORMANCE DRIVER (7.1)
66 PROPOSAL CURVE NO. RPM DRIVER TYPE Steam Turbine(2 Set) + Electrical Motor(1 Set)
67 IMPELLER DIA.: RATED MAX. MIN. mm For Steam HP Steam & For Electrical MV Voltage
68 RATED POWER : 2207.31707 kW EFFICIENCY 82 (%) (Esti.) GEAR B1
69 RATED CURVE BEP FLOW (at rated impeller diameter) (6.1.16) : m³/h VARIABLE SPEED REQUIRED YES NOTE 9 B1
70 MIN FLOW :(Note 6) THERMAL m³/h STABLE m³/h SOURCE OF VARIABLE SPEED
71 PREFERRED OPERATING REGION (6.1.16) to m³/h MANUFACTURER AVL
72 ALLOWABLE OPERATING REGION (6.9.4.1) to m³/h NAMEPLATE POWER : kW Min 1631.55 with API Factor 1.1
73 MAX HEAD @ RATED IMPELLER m NOMINAL RPM As Pump's Requirement
74 MAX POWER @ RATED IMPELLER kW RATED LOAD RPM
75 NPSH3 AT RATED FLOW (6.1.9) : m FRAME
76 CENTERLINE OF PUMP TO NPSHA DATUM m ORIENTATION HORIZONTAL
77 NPSH MARGIN AT RATED FLOW (6.1.10) : m LUBRICATION
78 SPECIFIC SPEED (6.1.17) m3/s, rpm, m BEARING TYPE over 40000Hr Long Life
79 SUCTION SPECIFIC SPEED LIMIT (6.1.11) m3/s, rpm, m 251 RADIAL
80 SUCTION SPECIFIC SPEED (6.1.11) m3/s, rpm, m THRUST
81 MAX. ALLOWABLE SOUND PRESSURE LEVEL (6.1.19) 85 @ 1m (dBA) STARTING METHOD
82 ESTIMATED MAX. SOUND PRESSURE LEVEL (dBA) DRIVER DATASHEET NUMBER Start From Page 9
83 MAX. ALLOWABLE SOUND POWER LEVEL (6.1.19) 85 @ 1m (dB) DRIVE DESIGN STANDARD IEC
84 ESTIMATED MAX SOUND POWER LEVEL (dB)
85
87 DATASHEET No. Rev: SHEET of
Note 1:
Client: Contractor:
Cont. No. : 73-01-1891
2 API PUMP TYPE (Table 1): BB1 VTA (Double Suction) CASING MOUNTING (6.3.14, 9.3.8.3): CENTERLINE
3 CASING TYPE:
8 PRESSURE CASING AUX. CONNECTIONS: (6.4.3) WETTING AGENT REQUIRED FOR HYDROTEST (8.3.2.7) :
9 No. Size Type Facing Rating Posn. HYDROTEST OH PUMP AS ASSEMBLY (8.3.2.14) :
11 DRAIN
12 VENT ROTOR:
17 DRAIN VALVE SUPPLIED BY (7.6.2.5) SUPPLIER ROTATION (VIEWED FROM COUPLING END) :
21 THREADED CONS FOR PIPELINE SERVICE & < 55°C (6.4.3.2) MANUFACTURER As Per AVL
26 RIGID-TYPE
31 MAXIMUM ALLOWABLE TEMPERATURE (3.1.19) °C COUPLING AND SHAFT GUARD STANDARD (7.3)
32 REDUCED-HARDNESS MATERIALS REQ'D (6.12.1.14) IGNITION HAZARD ASSESSMENT PER EN 13463-1 (7.3.2.2; 7.3.3.4)
36 DIFFUSERS
37 IMPELLER :
43 MOUNTING : GROUTED
48 REVIEW AND APPROVE THRUST BEARING SIZE : (9.2.5.2.6) PROVIDE SPACER PLATE UNDER ALL EQUIPMENT FEET (7.4.10)
49 LUBRICATION (6.11.3) (9.3.12.4) : PRESSURE LUBE BOLT OH 3/4/5 PUMP TO PAD / FOUNDATION :
50 PRESSURE LUBE SYSTEM TO API-614, CHAPTER : 3 PROVIDE SOLEPLATE FOR OH 3/4/5 PUMPS (9.1.2) :
39 THESE REFERENCES SHALL BE PROVIDED BY THE PURCHASER. (DEFAULT TO TABLE 11 IF NO PURCHASER PREFERENCE IS STATED)
40 ALTERNATIVE WELDING CODES AND STANDARDS
41 WELDING REQUIREMENT (APPLICABLE CODE OR STANDARD) DEFAULT PER TABLE 11
42 ALTERNATIVE WELDER/OPERATOR QUALIFICATION STANDARD
43 ALTERNATIVE WELDING PROCEDURE QUALIFICATION STANDARD
44 NON-PRESSURE RETAINING STRUCTURAL WELDING STANDARD (BASEPLATES OR SUPPORTS)
45 STANDARD FOR MAGNETIC PARTICLE OR LIQUID PENETRANT EXAMINATION (PLATE EDGES)
46 STANDARD FOR POSTWELD HEAT TREATMENT
47 STANDARD FOR POSTWELD HEAT TREATMENT OF CASING FABRICATION WELDS
48
49 MATERIAL INSPECTION
54 RADIOGRAPHY
55 ULTRASONIC INSPECTION
56 MAGNETIC PARTICLE INSPECTION
57 LIQUID PENETRANT INSPECTION
58 VISUAL INSPECTION (all surfaces)
59
60
DATASHEET No. Rev: SHEET OF
Client: Contractor:
Cont. No. : 73-01-1891
21 SHIPPING & STORAGE CONTAINER SUITABLE FOR RESIDUAL UNBALANCE TEST (J.4.1.2)
22 VERTICAL STORAGE (9.2.8.3) : NOTIFICATION OF SUCCESSFUL PERFORMANCE TEST (8.1.1.3) (8.3.3.4.6) YES
23 N2 PURGE REQUIRED (9.2.8.4) : BASEPLATE (NOZZLE LOAD) TEST (7.4.24)
51 BEARING LIFE CALCULATIONS REQUIRED (6.10.1.11) YES CASING DISASSEMBLY AFTER TEST (8.3.3.9)
52 CASING RETIREMENT THICKNESS DRAWING [L.3.6.1 cc) 7) xiii)] SPARE PARTS TEST (8.3.4.8)
53 CONNECTION BOLTING (7.6.1.7)
54 VENDOR TO KEEP REPAIR AND HT RCDS (8.2.1.1.c) YES
55 VENDOR SUBMIT TEST PROCEDURES (8.3.1.1) YES
56 SUBMIT INSPECTION CHECK LIST (8.1.5) YES
57 ACOUSTIC ANALYSIS OF CROSSOVER PASSAGE (BB3, BB5)(9.2.1.5)
58 API-691 DOCUMENTATION REQUIRED (6.1.3.1)
59
60
NOTES
1 Note # Rev
2 (1) 2 pumps are in operation, 1 motor driven in spare:
3
4 (2) will be finalized later.
5
6 (3) Shut‐off pressure estimated (to be confirmed after pump vendor selection): (6.1.11).
7
8 (4) Suction design condition: Temperature=34°C Pressure=0.91 barg
9
10 (5) Barrel shall have corrosion resistant coating (stainless steel, colmonoy or equal) to facilitate bundle removal.
11
12 (6) Automatic minimum flow protection (Schroder modulating type) to be supplied for each pump. The valve shall have four connections and shall be supplied by the pump vendor.
13
14 (7) The necessity of considering warming up shall be checked and advised by Vendor.
15
16 (8) All instrumentation shall comply with SPECIFICATION FOR INSTRUMENTATION AND CONTROL OF PACKAGES.
17
18 (9) only Turbine Drive Pumps are variable speed B1
19
20 (10) In case of MAWP uo to 19.65 barg, it will be applicable. Otherwise; class300# shall be considered B1
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
2 PROJECT: UNIT: 22
6 OPERATING CONDITIONS
7 SITE DATA: INDOOR OUTDOOR X DUTY: Continuous
8 ALTITUDE: LESS THAN 1000 m OTHER: 1685 [m] SERVICE FACTOR: 105 / 115 %
9 AMBIENT TEMP., MAX/MIN: -21 / 43 [°C] HUMIDITY: 78 % STATOR CONNECTION: STAR / By Vendor
11 VOLTS: 6000±5% [V] PHASE: 3 FREQ.: 50±5% [Hz] SUPPLY PRESSURE: [kg/cm²g] TEMP.: [°C]
13 CLASS: - ZONE: - GAS GROUP: - TEMP. CLASS: - AIR / GAS COOLING (IF REQUIRED):
14 STARTING METHOD: DIRECT ON-LINE DOL X STAR/DELTA SUPPLY PRESSURE: [kg/cm²g] FLOW:
(1)
15 STARTER: VACUUM X OIL AIR ADJUSTABLE FREQUENCY DRIVE :
16 STARTING: OFF LOAD X ON LOAD SPEED RANGE FROM: By Vendor [rpm] TO: By Vendor [rpm]
19 TEMPERATURE RISE: B 80+(25 Margin) [ºC] UP TO: With Ambient 40: 105 [°C]
21 RE-ACCELERATION
22
23 PERFORMANCE
24 NAMEPLATE POWER: By Vendor [kW] RATED POWER: > 1680kW [kW] STARTS PER HOUR: HOT: 2 COLD: 3
25 SPEED, SYNCH: As Selected Motor [rpm] FULL LOAD SPEED: As Pump' need [rpm] STALL TIME (Max): HOT: VTA COLD: VTA
30 LOCKED ROTOR CURRENT: <6x In (Rated Current) [A] HOT: VTA [sec] COLD: VTA [sec]
2
31 NO LOAD CURRENT: By Vendor [A] MOTOR ROTOR INERTIA (GD ): By Vendor [kg.m2]
32 FULL-LOAD TORQUE: By Vendor Above Load Torque [N-m] DRIVEN LOAD INERTIA (GD2): By Vendor [kg.m2]
37 STATOR REACTANCE: By Vendor [ohms] @: [°C] SUB-TRANSIENT (X"d): By Vendor X/R RATIO:
38 ROTOR RESISTANCE AT FULL LOAD: By Vendor [ohms] @: [°C] STEADY STATE (X): By Vendor
39 ROTOR REACTANCE AT FULL LOAD: By Vendor [ohms] @: [°C] ZERO SEQUENCE (X0): By Vendor
40 ROTOR RESISTANCE AT LOCKED ROTOR: By Vendor [ohms] @: [°C] MAGNETIZING (Xm): By Vendor
41 ROTOR REACTANCE AT LOCKED ROTOR: By Vendor [ohms] @: [°C] COOL DOWN TIME: RUNNING: STOPPED: [sec]
43 CONSTRUCTION FEATURES
44 CONSTRUCTION (MOUNTING):
53
55
56
Client: Contractor:
Cont. No. : 73-01-1891
3 VOLTS: 6000 [V] PHASE: 3 FREQ.: 50 [Hz] GROUND CONNECTION: INTERNAL EXTERNAL X
5 SEPARATE TERMINAL BOX FOR SPACE HEATER Required LIFTING HOOK EYE BOLT: REQUIRED NOT REQUIRED
6 BEARING TEMP. DETECTORS, NUMBER/ BEARING: 1 /2 1 for each bearing ALLOWABLE SOUND PRESSURE LEVEL: 85 @ 1Meter [dBA]
8 TYPE: By Vendor LOCATION: By Vendor WEIGHT: NET: By Vendor SHIPPING: By Vendor [kg]
9 SET: @ VTA [°C] FOR ALARM VTA [°C] FOR SHUT DOWN MAX. MAINT. WEIGHT: By Vendor [kg]
10 MATERIAL: By Vendor RESISTANCE: By Vendor [ohms] DIMENSIONS: L: By Vendor W: By Vendor H: By Vendor [m]
11 WINDING TEMPERATURE DETECTORS, NUMBER / PHASE: 2 for each winding BASEPLATE: COMMMON WITH DRIVEN EQUIPMENT
14 SET: @ VTA [°C] FOR ALARM VTA [°C] FOR SHUT DOWN DRAIN PLUG
16 SEPARATE TERMINAL BOX FOR WINDING & BEARING TEMP. MONITORS Required DE/ NDE: Yes
17 MOTOR ARRANGED FOR DIFFERENTIAL PROTECTION (RATING ABOVE 1000KW): Required LUBRICATION: Required / Interval period By Vendor's recommended
19 CT ACCURACY: Class X / 5P20 As VTA CT RATIO: VTA BURDEN: VTA [VA] MANUFACURER: AVL ΔP:
20 TYPE: WINDOW TYPE BUSBAR TYPE HEAT EXCHANGER: By Vendor (If ANY) REQUIRED FLOW:
24 VIBRATION SWITCHES MANUFACTURER: AVL MAIN TERMINAL BOX CABLE ENTRY NO./ THREAD SIZE: By Vendor [mm2]
25 VIBRATION DETECTORS Above 1500kW Required MANUFACTURER: AVL MOTOR MAIN TERMINAL BOX MAX. CABLE SIZE: By Vendor [mm2]
26 MODEL: By Vendor TYPE: VTA SPACE HEATER TB CABLE ENTRY NO./ THREAD SIZE: By Vendor [mm2]
27 NO. PER BEARING: 1 LOCATION: VTA SPACE HEATER TERMINAL BOX MAX. CABLE SIZE: By Vendor [mm2]
28 SET: @ FOR ALARM FOR SHUT DOWN [mm/sec] TEMP. DET. TB CABLE ENTRY NO./ THREAD SIZE: By Vendor [mm2]
29 SEPARATE TERMINAL BOX FOR VIBRATION MONITORS TEMP. DETECTOR TERMINAL BOX MAX. CABLE SIZE: By Vendor [mm2]
30 TERMINAL BOX & CABLE DETAILS: CT CONN. TB CABLE ENTRY NO./ THREAD SIZE: 3 [mm2]
31 TYPE: STEEL CT CONNECTION TERMINAL BOX MAX. CABLE SIZE: 2x10 [mm2]
32 LOCATION FACING DRIVE END: RIGHT X LEFT TOP X VIBRATION MON. TB CABLE ENTRY NO./ THREAD SIZE: 2 [mm2]
33 CABLE CONDUCTOR MATERIAL: COPPER X ALUMINUM VIBRATION MON. TERMINAL BOX MAX. CABLE SIZE: 10 [mm2]
35 ARMORED CABLE X FLEXIBLE CONDUIT WITH LEAD SHEATH TYPE TEST CERTIFICATE REFERENCE: By Vendor
37 MAIN MOTOR LEADS X SPACE HEATER LEADS X COPY OF CERTIFICATE ATTACHED (YES/NO): Yes
42 MOTOR MAIN CABLE ENTRY NO./ THREAD SIZE: 2 / By Vendor [mm] CURVES TO BE PROVIDED: SPEED- TORQUE- CURRENT CURVE X
45 SPACE HEATER CABLE ENTRY NO./ THREAD SIZE: 1 / By Vendor [mm] THERMAL LIMIT CURVE X
55 MOTOR ENCLOSURE MATERIAL: STEEL 3- DIFFERENTIAL PROTECTION (87M) Will Be Considered (Supplied by others). Neutral connection of Windings
56 FAN MATERIAL- NON SPARKING: CORROSION RESISTANT MATERIAL shall be brought out to suitable box.
Client: Contractor:
Cont. No. : 73-01-1891
7 ABSORBED POWER, SPEED, OPERATING POINT/ NO. HAND VALVES STEAM RATE,
8 OPERATING POINT kW RPM STEAM CONDITION OPEN kg/kW-h
NORMAL/NORMAL
9 NORMAL VTA VTA VTA VTA
CERTIFIED STEAM RATE
10 RATED VTA VTA RATED/NORMAL VTA VTA
RATED @ MINIMUM INLET & MAXIMUM
11 OTHER (6.1.4) VTA VTA VTA VTA
EXHAUST
12
OTHER/NORMAL CONDITIONS
13 APPLICATION IS: UNSPARED VTA VTA
14 WIDE SPEED RANGE RAPID START APPLICABLE SPECIFICATION
47 MAX. NOZZLE STEAM FLOW, VTA kg/h MAX. ALLOW. PRESS, kPa g
48 ROTATION FACING GOVERNOR END MAX ALLOW. TEMP, °K
49 HYDRO TEST PRESS., kPa g
50 VERTICAL DRIVEN EQUIPMENT THRUST N
51 VERTICAL TURBINE THRUST CAPACITY N
52 WATER PIPING REQUIRED: VTA REMARKS:
53 FURNISHED BY:
54 OIL PIPING REQUIRED: YES
55 FURNISHED BY: SUPPLIER
56 AUTO DRAIN SYSTEM REQ'D (6.2.9.1): VTA
57 FURNISHED BY: VTA
2
58
Client: Contractor:
MFR. MODEL
39 TURBINE SHAFT FURN. RADIAL PROBES YES NO. OF PROBES/BEARING 2
40 MFR. MODEL
41
MFR. MODEL
42 MOUNTING PLATES FURNISH BEARING METAL TEMP SENSORS FOR:
43 TURBINE MOUNTED ON BASEPLATE RADIAL BEARINGS YES THRUST BEARINGS YES
44 FURN. BY: DRIVEN EQUIPMENT VENDOR MAGNETIC SEISMIC PROBES
45 EQUIPMENT TO BE MOUNTED: PERMANENT SEISMIC PROBES
46 DRIVEN EQUIP + TURBINE&Gear MFR. MODEL
47 TURBINE VENDOR SUPPLIES MONITORS
48 UNGROUTED BASEPLATE AXIAL AND RADIAL PROBES YES
49 BEARING TEMPERATURE SENSORS YES
50 SUBPLATES REQUIRED SEE SEPARATE DATA SHEETS FOR DETAILS
51 REMARKS:
52 GEARBOX 1- Will be finallized later
53 GEARBOX REQUIRED YES
54 FURN. BY: TURBINE VENDOR
55 APPLICABLE SPECIFICATION
56 GEARBOX DATA SHEET NUMBER
57
58
Client: Contractor:
12 GOVERNOR POWER SUPPLY (VTS) EXTERNAL TESTS (8.3) REQ'D. WITN.OBSVD. (8.1.1)
25 ENGINEERING REQUIREMENTS
31 WEIGHTS
43
52
53
54
55
Client: Contractor:
4 2 When not in operation, the turbine shall be able to run at low speed (''prerotation mode'') to permit a quick automatic start‐up; vendor to indicate the steam consumption in ''prerotation mode''.
5
6 3 All instrumentation shall comply with SPECIFICATION FOR INSTRUMENTATION AND CONTROL OF PACKAGES.
7
8 4
9
10 5
11
12 6
13
14 7
15
16
17
18
19
20
21
22
23
24
25
26
27
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
Client: Contractor:
Cont. No. : 73-01-1891
DATA SHEET FOR GENERAL PURPOSE OIL SYSTEM (API 614-1) (Continued) Rev
1 Apply To: Proposal Purchase As Built
2 For Site
4 Supplier Manufacturer
7 Explanations:
11 - Designations in parentheses ( ) are: explained in the cited standard; numbers without a prefix are subclause numbers; those
12 prefixed “T” are text figure numbers; those prefixed “A” are Annex “A” Figure numbers.
13 Applicable documents:
15 Instrument Suppliers (API 614/ISO 10438-1) Pump Drivers (Motor) GENERAL SPECIFICATION FOR LV MOTORS
16 Special Purpose Oil Systems (API 614/ISO 10438-2) Pump Drivers (Turbine)
18 Self-acting Gas Seal Support Modules (API 614/ISO 10438-4) Additional documents
21
27 (Sketch the equipment plot plan with relation to the console location here)
29 Winterize Tropicalize Minimum clearance and access to components required (-2, 4.1.13; -3, 4.2.9) (m)
31
33 Lube oil (-2, 4.1.8; -3, 4.2.7): Normal After trip Seal oil - Range of operating conditions (-2, 4.1.10):
supply pressure
34 (MPa, gauge) (m³/h) (m³/h) (m³/h) (MPa, gauge)
Driven equipment Normal operation /
35
Driven equipment Settling-out pressure /
36
Driven equipment Process relief-valve setting /
37
Prime mover Shop test and field run-in /
38
Gears Startup /
39
Couplings Other /
40
Total: Oil type / viscosity:
41
Control oil (normal) (-2, 4.1.7; -3, 4.2.6)
42
Control oil (transient) Required heat load
43 (kJ/hr)
44
45
46
47
48
49
50
Client: Contractor:
3 Min/max temperature (°C) -21 43 Volts 400 Inlet temperature (°C) Maximum return (°C)
15
16 Location (4.5.2):
18 Outdoor Unheated
23
25 Install new filter elements and tag Spare parts quotation with proposal
26 Include sets of extra filter elements Spare parts quotation after contract
27 Box extra sets with the system Above based on normal supply for months.
31
32
33
36 Domestic
37 Export
38 Extended Storage
39 months
41 Comments:
42
43
44
45
46
47
48
49
50
Client: Contractor:
2 For Site
4 Supplier Manufacturer
8 Pressure gauges
9 Temperature gauges
10 Level gauges
12 Pressure switches
14 Temperature switches
15 Level switches
16 Control valves
20 Pressure transmitter
21 Vibration equipment
22 Tachometer
23 Solenoid valves
24 Annunciator
25 Thermocouples
27 Thermowells
28
29
30
31
32
33
34
35
36
37
39 Comments:
40
41
42
43
44
45
46
47
50
Client: Contractor:
2 For Site
4 Supplier Manufacturer
7 Explanations:
11 - Designations in parentheses ( ) are: explained in the cited standard; numbers without a prefix are subclause numbers; those
12 prefixed “T” are text figure numbers; those prefixed “A” are Annex “A” Figure numbers.
15 Panel identification P P P
16 Supplied by Vendor Vendor Vendor
17 Type: free standing
37 Chassis
43 equipment (6.3.1.3) P P
44 Multipoint instruments permitted (6.3.2.6) No No No
45
Note 1 : Refer to SPECIFICATION FOR INSTRUMENTATION AND CONTROL OF PACKAGES and Specification for Lubrication, Shaft-Sealing, Oil-Control Systems and Auxiliaries.
46
47
48
49
50
Client: Contractor:
2 For Site
4 Supplier Manufacturer
7 Explanations:
11 - Designations in parentheses ( ) are: explained in the cited standard; numbers without a prefix are subclause numbers; those
12 prefixed “T” are text figure numbers; those prefixed “A” are Annex “A” Figure numbers.
13 Use the following code letters for details of panel mounted items:
15 F - Flush mount on front H - Purchaser remote mount (control room) CP - Cutout to purchaser item
16 S - Surface mount on front P - Purchaser supply and mount M - Mount by vendor of purchaser
49 Discharge separator
Client: Contractor:
2 For Site
4 Supplier Manufacturer
7 Explanations:
11 - Designations in parentheses ( ) are: explained in the cited standard; numbers without a prefix are subclause numbers; those
12 prefixed “T” are text figure numbers; those prefixed “A” are Annex “A” Figure numbers.
13 Instrumentation
(See Remark 1)
16 Switches shall be wired to: open (de-energize) or close (energize) to initiate alarms and shutdowns (6.3.2.4)
18 Transmitters shall be provided (6.3.3.1, 6.3.3.2) Output signal type Housing type
22 Sight flow indicators installed in the drain lines of totally enclosed dry coupling guards (6.3.9.2)
23 Restrictive flow indicators installed on in the pressurized inlet line to each continuously lubricated coupling (6.3.9.5)
25 Thermal relief valves provided for components that may be blocked in by isolation valves (6.3.11.5)
26 Electrical Systems
27 Characteristics of electrical power supplies for motors, heater and instruments shall be specified (6.4.2)
28 Instrument and control wiring may be solid conductors in areas not subject to vibration (6.4.6)
30 Conduit drains provided in all conduit low points for indoor installations (6.4.18)
31 Electrical materials, including insulation, shall be corrosion resistant and non-hygroscopic (6.4.11)
33 Any alarm shall initiate: Audible warning Flashing light Both Audible Warning and flashing light [6.2.2.5b)]
34 Any shutdownshall initiate: Audible warning Flashing light Both Audible Warning and flashing light [6.2.2.5c)]
35 Remarks:
37
38
39
40
41
42
43
44
45
46
47
48
49
Client: Contractor:
Cont. No. : 73-01-1891
2 For .
3 Oil System for Cooling Water Pumps
4 Supplier
5 Purchase Order No. Date
6
10 3. Designations in parenthesis ( ) are explained in the cited standard; numbers without a prefix are subclause
11 numbers; those prefixed “T” are text figure numbers; those prefixed “A” are Annex “A” Figure numbers.
13
30 Special provisions necessary for back-up supply of lube oil (4.2.15): Standby pump Rundown tank (VTA)
31 Components: All steel external components (4.2.11)
34 Carbon steel slip-on flanges not allowed (ISO 10438-1, T 1-4) Air
37 Valve heads vented to reservoir Valved vents, drains and piping furnished to permit
44 Model Trim
45 Remarks
46
47
48
49
Client: Contractor:
2 Supplier Manufacturer
3 Purchase Order No. Inquiry no.
4 Date Requisition No.
6 Oil conditioners:
13
17 Electric heater (4.4.7) Removable during operation [4.4.7.c)] Pump type and material:
29 Insulation clips (4.4.8) Motor driven start-up w/shaft drive main (4.5.3)
35 Flanged drain connection (4.4.4.3) IEC1) NEMA Other GENERAL SPECIFICATION FOR LV MOTORS
39 Top mounted components are: Jackscrews provided for pump driver [4.5.19.e)]
40
43
44 1)
Applicable part(s) of IEC 60034.
45 Remarks
46
47
48
49
49
Client: Contractor:
2 Supplier Manufacturer
3 Purchase Order No. Inquiry no.
6 Filters:
13 Filter drains manifolded with cooler drains (4.7.4) Vents piped to reservoir (4.7.5), with flow indicators (4.7.6)
19 Coolers: None required (4.6.1.1) Single Connections only for off-base cooler [4.6.1.2.b)]
20 Type: Shell and tube Fin fan [4.6.1.2.a)] Plate frame [4.6.1.2.a)] Flanged vent & drain nozzles (4.6.1.8)
21 Refer to specification Supplier std. Special sizing criteria [4.6.1.2.f)] Vents piped to reservoir (4.6.1.10)
22 Suitable for use with 150° C (300° F) coolant (4.6.1.6) Cooler drains manifolded with filter clean oil drains (4.6.1.9)
26
31 Fouling factor water/oil side (NOTE 1) Refer to Utility and Site Condition Tube water velocity and capacity (m/s) / (lit)
34 Oil temperature control valve with bypass line (4.6.1.4): Tube sheets and tubes ( 4.6.2.4) S.S. 304
35 Flanged, pneumatically operated [4.6.1.4.b)] Oil side operating pressure less than water side [4.69.2.1.c)]
36 Manual override (4.6.1.6) Removable bundle (4.6.2.1)
39 Austenitic stainless steel tubes [4.6.4.2.b)] High vibration alarm for each fan [4.6.4.2.e)]
40
45 Remarks
46
47
48
49
50
1 Applicable to Proposal Purchase As built Rev.
2 Supplier Manufacturer
3 Purchase Order No. Inquiry no.
7 Condition
14
23 Certified copies of all test logs and data Hydro test assembled system
25 Pipe radiography (5.1.3) Certified copies of all test logs and data
27 Vendor's Data:
29
30 Comments:
31
32
33 NOTE 1: FOR INSTRUMENTATION , PLEASE REFER TO " SPECIFICATION FOR INSTRUMENTATION AND CONTROL OF PACKAGES"
34 NOTE 2: REFERENCE: "Specification for Lubrication, Shaft-Sealing, Oil-Control Systems and Auxiliaries "
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
Client: Contractor:
Cont. No. : 73-01-1891
FOR UNIT
SERVICE EQUIPMENT
SIZE
CONNECTIONS
WITH NON-RETURN VALVE IN BYPASS VALVE MATERIALS CODE SPECIFICATION
CONE
SPRINGS
CORR/EROS DUE TO -
PUMP CURVE
50% m³/h
100% m³/h
H0 m
H50 m
TOTAL H100 m
HEAD H Hq m
H3 m
MAX.DISCHARGE PRESSURE P1
AT MIN. FLOW
BACK PRESSURE P3
ON AUTOM. BRANCH
BACK PRESSURE P4
ON HAND OP. BRANCH
DIFFERENTIAL PRESSURE P1-P3= Pq
AT BYPASS
INSPECTION REQUIREMENTS
NOTES
1- MINIMUM FLOW CHECK VALVE SHOULD BE MOUNTED VERTICALLY