Where 100 Congress and 101 Colorado Garage – 100 Congress St. Austin Tx
:
When: 11/28/2022
What: 7 lanes of equipment, 7 gates, 14 Loops, 1 POF, 1 Conduit Run, 7 Umojo cameras
Scope of Work:
-- Existing Equipment: 7 Kiosks, 7 Gates, 1 Cash POF, intercom removal.
Decommission equipment in existing (7) lanes.
o Store in client designated area
Install (3) Smart Stations (1 Entry, 1 Exit, 1 POF)
Install (4) L1 Mini Stations (1 Entry, 3 Exits)
Install (7) Articulating gates, including gate arm assembly and anchor bolts
Install (7) Cameras
o Will need to run cat6 and conduit to camera locations. (about 15-20ft)
Install (7) bollards
Cut/install/seal a total of (14) loops
o Flash to provide loops
18-10 shielded comm wire between the kiosk and gate
o Ethernet cables will need to be run to 100 Congress from the server room at 101
Colorado.
o About 200ft. Will require getting in the ceiling to locate conduit.
We will be putting the mini power supplies in gates
o If there is no room in the conduit we will need to run surface mounted between gates
and kiosks.
Ensure all equipment is level
Caulk/mortar around bases of equipment as needed
Dispose of any trash/debris left from install
Running any Conduit needed within 15ft max.
Shipping will need to be picked up from the warehouse