INSTRUMENTATION PARTS LIST

POWER CONTROL ROOM – Drilling Unit


1. Main PLC – Siemens 1517F
2. Backup PLC – Siemens 1517F
3. Data Acquisition System PLC – Siemens 1516F
4. Driller Control Cabin PLC - Siemens 1516F
5. AutoDriller PLC - Siemens 1516F
6. Profinet Switch Media Convertor (Qty-2) – Profibus to Fiber Optic
7. Profinet Convertor (Qty-2)
8. Remote I/O

a. Drawworks g. Drilling Unit MCC 4


b. TDS h. Gen Set 1
c. Mud Pump i. Gen Set 2
d. Drilling Unit MCC 1 j. Gen Set 3
e. Drilling Unit MCC 2 k. Gen Set 4
f. Drilling Unit MCC 3 l. Gen Set 5

9. 7” HMI Screen for HVAC


10. 15” HMI Screen (Qty-2)
11. Main Server
12. Engineering Station
13. Backup Server
14. Network Hard Drive
15. Backup Network Hard Drive
16. UPS (Qty-2)
17. PoE Ethernet Switch – for TalkBack
18. TalkBack Station

POWER CONTROL ROOM – Mud Unit


1. Ethernet Switch – Connected to Profibus Convertor in PCR-Drilling Unit
2. Profibus Switch Media Convertor
3. Remote I/O
a. Mud Unit MCC (Qty-6)
b. Mud Pump 1
c. Mud Pump 2
d. Mud Pump 3
4. 15” HMI Screen
5. 7” HMI Screen for HVAC
6. UPS (Qty-2)
7. TalkBack Station
DRILLERS CONTROL CABIN
1. DCC PLC – Siemens 1516F
2. 32” HMI (Qty-2)
3. 22” HMI (Qty-4)
4. 15” HMI (Qty-4)
5. Microbox PC (Qty-10) – One for each HMI
6. Ethernet Switch Media Convertor (Qty-2)
7. IRIS ID
8. Profinet Switch Media Convertor (Qty-2)
9. Talkback Master Station
10. TalkBack Rack Panel – for Monkey Board (Headphone + Wireless)
11. Wiper System
12. ET200MP Module
13. CMS ETD – Related to Mud Pump
14. BOP Control Unit
15. Remote I/O
a. Left Armrest (Qty-2)
b. Right Armrest (Qty-2)
c. Cyber Chair Base (Qty-2)
16. Left + Right Joystick (Qty-2)

DRAWWORKS
1. Encoder
a. Motor A
b. Motor B
c. Anti Collision System
2. Level Switch
a. Lube Oil Min
b. Lube Oil Max
c. Lube Oil Alarm
3. Pressure Switch

a. Motor A Blower c. Intervention Crown-o-matic


b. Motor B Blower d. Lube Oil Filter Clogged

4. Pressure Transducer
a. Lube Oil
b. Related to air (Qty 6)
5. Lube Oil Temp Transducer
6. Vibration Sensor (Qty 15)
TDS
1. Incremental Encoder
2. Oil Temp Transmitter (Qty-2) – Lube and HPU
3. Oil Level Switch HPU
4. Lube Oil Heater Max Temp
5. Brake Thermocouple
6. Pressure Switch

a. Blower e. Lube Oil Filter Clogging


b. Brake Engaged f. Lube Oil Low Pressure
c. Back-up Wrench Open/Close g. Elevator Open/Close
d. High Press Filter Clogging h. Return Filter Clogging

7. Vibration Sensor (Qty-8)

MUD PUMP
1. Pressure Switch

a. Air c. Gearbox Lube Clogged


b. Forced Lube d. Forced Lube Clogged

2. Level Switch

a. Gearbox Lubrication b. Forced Lubrication

3. Flow Switch

a. Lube b. Liner

4. Gearbox Lube Pressure Transducer


5. Gearbox Lube Temperature Transducer
6. Forced Lube Temp Transducer
7. Vibration Sensor (Qty 16)

STINGER / VERTICAL PIPE HANDLER


1. Encoder

a. Motor Winch Up/Down d. Lower Section – Servomotor B


b. Lower Section – e. Upper Section - Servoactuator
Servoactuator f. Upper Section - Servoactuator
c. Lower Section – Servomotor A g. Upper Section - Servomotor

2. Laser Distance Sensor (Qty 3)


3. Position Transducer (Qty 5)
4. Proximity Sensor (Qty 7)
5. Pressure Switch (Qty 9)
6. Temperature Transducer
7. Oil Level
8. Load Cell (Qty 4)
9. VERTICAL PIPE HANDLER CONTROL PANEL -DOG HOUSE
a. Main PLC for Pipe Handler
b. Profinet Switch Media Convertor
c. ET200MP Module

TALKBACK STATION POINTS


1. PCR-Drilling 5. Assembly Point
2. PCR-Mud Unit 6. Utility System
3. Drill Floor 7. Pig House
4. DIC Room

CAMERA LOCATIONS
1. Mud Pump Area 4. Catwalk Area
2. Shale Shaker Area 5. Monkey Board
3. Cellar Pit Area 6. Drill Floor

MUD SYSTEM – Tank Area


1. Remote I/O Station