Professional Documents
Culture Documents
87
www.hilti.com.au
Company: ARP Engineering Page: 1
Address: Southbank Blvd., Southbank, VIC 3006 Specifier:
Phone I Fax: | E-Mail:
Design: Dual Hoop Date: 11/8/2023
Fastening Point:
Specifier's comments:
1 Input data
Anchor type and size: HIT-RE 500 V4 + HAS-U 5.8 M30
Return period (service life in years): 50
Item number: not available (insert) / 2287553 HIT-RE 500 V4
(mortar)
Hilti Filling Set or any suitable annular gap filling solution
Effective embedment depth: hef,act = 600.0 mm (hef,limit = - mm)
Material: 5.8
Approval No.: ETA 20/0541
Issued I Valid: 9/6/2023 | -
Proof: Design Method AS 5216:2021, Chemical
Stand-off installation: eb = 0.0 mm (no stand-off); t = 50.0 mm
Baseplate :
R lx x ly x t = 600.0 mm x 1,000.0 mm x 50.0 mm; (Recommended plate thickness: not calculated)
Profile: no profile
Base material: 2
cracked concrete, 32MPa, f'c = 32.00 N/mm ; h = 700.0 mm, Temp. short/long: 0/0 °C, User-defined
partial material safety factor gc = 1.500
Installation: Diamond cored hole with roughening, Installation condition: Water saturated
Reinforcement: No reinforcement or Reinforcement spacing >= 150 mm (any Ø) or >= 100 mm (Ø <= 10 mm)
no longitudinal edge reinforcement
Reinforcement to control splitting acc. to AS5216:2021 / SA TS 101:2015, 6.2.5.2 (b) present
R
- The anchor calculation is based on a rigid baseplate assumption.
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
1
Hilti PROFIS Engineering 3.0.87
www.hilti.com.au
Company: ARP Engineering Page: 2
Address: Southbank Blvd., Southbank, VIC 3006 Specifier:
Phone I Fax: | E-Mail:
Design: Dual Hoop Date: 11/8/2023
Fastening Point:
5 6
Anchor reactions [kN]
Tension force: (+Tension, -Compression)
Anchor Tension force Shear force Shear force x Shear force y
1 33.047 46.735 0.000 46.735
2 33.047 46.735 0.000 46.735 3 4 x
3 33.047 46.735 0.000 46.735 Tension
4 33.047 46.735 0.000 46.735
5 33.047 46.735 0.000 46.735
6 33.047 46.735 0.000 46.735
1 2
max. concrete compressive strain: - [‰]
max. concrete compressive stress: - [N/mm ]
2
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
2
Hilti PROFIS Engineering 3.0.87
www.hilti.com.au
Company: ARP Engineering Page: 3
Address: Southbank Blvd., Southbank, VIC 3006 Specifier:
Phone I Fax: | E-Mail:
Design: Dual Hoop Date: 11/8/2023
Fastening Point:
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
3
Hilti PROFIS Engineering 3.0.87
www.hilti.com.au
Company: ARP Engineering Page: 4
Address: Southbank Blvd., Southbank, VIC 3006 Specifier:
Phone I Fax: | E-Mail:
Design: Dual Hoop Date: 11/8/2023
Fastening Point:
Rk,c
³ 1.00 AS 5216:2021, Eq. 6.2.5.5(2)
k3
p · d √hef · fc
'
t Rk,c = · AS 5216:2021, Eq. 6.2.5.5(3)
c
y s,Np = 0.7 + 0.3 · 1.00 AS 5216:2021, Eq. 6.2.3.4
ccr,Np £
1
y ec1,Np = 1.00 AS 5216:2021, Eq. 6.2.3.6
2 · ec1,N £
1+ (scr,Np )
1
y ec2,Np = 1.00 AS 5216:2021, Eq. 6.2.3.6
2 · ec2,N £
1+ (scr,Np )
2 0 2 2 2
Ap,N [mm ] Ap,N [mm ] t Rk,ucr,20 [N/mm ] scr,Np [mm] ccr,Np [mm] cmin [mm] fc,cyl [N/mm ]
1,105,000 671,454 14.00 819.4 409.7 300.0 32.00
0
yc t Rk,cr [N/mm ]
2
k3 t Rk,c [N/mm ]
2
y g,Np y g,Np
1.000 8.50 7.700 11.32 1.506 1.200
Group anchor ID
1-6
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
4
Hilti PROFIS Engineering 3.0.87
www.hilti.com.au
Company: ARP Engineering Page: 5
Address: Southbank Blvd., Southbank, VIC 3006 Specifier:
Phone I Fax: | E-Mail:
Design: Dual Hoop Date: 11/8/2023
Fastening Point:
2 0 2 2
Ac,N [mm ] Ac,N [mm ] ccr,N [mm] scr,N [mm] fc,cyl [N/mm ]
1,105,000 360,000 900.0 1,800.0 32.00
' ' '
hef [mm] ccr,N [mm] scr,N [mm]
200.0 300.0 600.0
Group anchor ID
1-6
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
5
Hilti PROFIS Engineering 3.0.87
www.hilti.com.au
Company: ARP Engineering Page: 6
Address: Southbank Blvd., Southbank, VIC 3006 Specifier:
Phone I Fax: | E-Mail:
Design: Dual Hoop Date: 11/8/2023
Fastening Point:
0
VRk,s [kN] k7 VRk,s [kN] f Ms,V VRd,s [kN] V* [kN]
168.360 1.000 168.360 0.800 134.688 46.735
2 0 2 2
Ac,N [mm ] Ac,N [mm ] ccr,N [mm] scr,N [mm] k8 fc,cyl [N/mm ]
1,105,000 360,000 900.0 1,800.0 2.000 32.00
' ' '
hef [mm] ccr,N [mm] scr,N [mm]
200.0 300.0 600.0
Group anchor ID
1-6
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
6
Hilti PROFIS Engineering 3.0.87
www.hilti.com.au
Company: ARP Engineering Page: 7
Address: Southbank Blvd., Southbank, VIC 3006 Specifier:
Phone I Fax: | E-Mail:
Design: Dual Hoop Date: 11/8/2023
Fastening Point:
= 0.1 · (
c )
d nom
b AS 5216:2021, Eq. 7.2.3.2(3)
1
0 2
Ac,V = 4.5 · c1 AS 5216:2021, Eq. 7.2.3.3
c2
y s,V = 0.7 + 0.3 · 1.00 AS 5216:2021, Eq. 7.2.3.4
1.5 · c1 £
0,5
y h,V = (1.5h· c ) 1
³ 1.00 AS 5216:2021, Eq. 7.2.3.5
1
y ec,V = £ 1.00 AS 5216:2021, Eq. 7.2.3.6
1+ ( 2 · eV
3 · c1 )
y a,V = √(cos a ) + (10.5 · sin a )
V
2
V
2 ³ 1.00 AS 5216:2021, Eq. 7.2.3.7
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
7
Hilti PROFIS Engineering 3.0.87
www.hilti.com.au
Company: ARP Engineering Page: 8
Address: Southbank Blvd., Southbank, VIC 3006 Specifier:
Phone I Fax: | E-Mail:
Design: Dual Hoop Date: 11/8/2023
Fastening Point:
5 Combined tension and shear loads (AS 5216:2021, Section 8.1.1, 8.1.2)
Steel failure
a a
bN + bV £ 1.0
Concrete failure
Comments: Tension displacements are valid with half of the required installation torque moment for uncracked concrete! Shear displacements
are valid without friction between the concrete and the baseplate! The gap due to the drilled hole and clearance hole tolerances are not
included in this calculation!
The acceptable anchor displacements depend on the fastened construction and must be defined by the designer!
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
8
Hilti PROFIS Engineering 3.0.87
www.hilti.com.au
Company: ARP Engineering Page: 9
Address: Southbank Blvd., Southbank, VIC 3006 Specifier:
Phone I Fax: | E-Mail:
Design: Dual Hoop Date: 11/8/2023
Fastening Point:
7 Warnings
• The anchor design methods in PROFIS Engineering require rigid baseplates per current regulations (AS 5216:2021, ETAG 001/Annex C,
EOTA TR029 etc.). This means load re-distribution on the anchors due to elastic deformations of the baseplate are not considered - the
baseplate is assumed to be sufficiently stiff, in order not to be deformed when subjected to the design loading. PROFIS Engineering
calculates the minimum required baseplate thickness with CBFEM to limit the stress of the baseplate based on the assumptions explained
above. The proof if the rigid baseplate assumption is valid is not carried out by PROFIS Engineering. Input data and results must be
checked for agreement with the existing conditions and for plausibility!
• Checking the transfer of loads into the base material is required in accordance with AS 5216:2021, Appendix C!
• The design is only valid if the clearance hole in the fixture is not larger than the value given in Table 4.2.2.1 of AS 5216:2021! For larger
diameters of the clearance hole, see section 2.2 of SA TS 101: 2015!
• The accessory list in this report is for the information of the user only. In any case, the instructions for use provided with the product have to
be followed to ensure a proper installation.
• For the determination of the y re,v (concrete edge failure) the minimum concrete cover defined in the design settings is used as the concrete
cover of the edge reinforcement.
• Characteristic bond resistances depend on short- and long-term temperatures.
• Edge reinforcement is not required to avoid splitting failure
• Design is only valid if hole is filled to remove clearance, clearance as per AS 5216:2021
• Load transfer from supplementary reinforcement to the structural member shall be verified by the responsible structural engineer.
• With supplementary reinforcement and post-installed anchors, please ensure that in the jobsite the rebars are not drilled through.
• The characteristic bond resistances depend on the return period (service life in years): 50
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
9
Hilti PROFIS Engineering 3.0.87
www.hilti.com.au
Company: ARP Engineering Page: 10
Address: Southbank Blvd., Southbank, VIC 3006 Specifier:
Phone I Fax: | E-Mail:
Design: Dual Hoop Date: 11/8/2023
Fastening Point:
8 Installation data
2 2
Baseplate, steel: Grade 350; E = 200,000.00 N/mm ; fyk = 340.00 N/mm Anchor type and size: HIT-RE 500 V4 + HAS-U 5.8 M30
Profile: no profile Item number: not available (insert) / 2287553 HIT-RE 500
V4 (mortar)
Hole diameter in the fixture: df = 33.0 mm Maximum installation torque: 300 Nm
Plate thickness (input): 50.0 mm Hole diameter in the base material: 35.0 mm
Recommended plate thickness: not calculated Hole depth in the base material: 600.0 mm
Drilling method: Core drilled + Roughening tool Minimum thickness of the base material: 670.0 mm
Cleaning: Compressed air cleaning of the drilled hole according to instructions
for use is required
Hilti HAS-U threaded rod with HIT-RE 500 V4 injection mortar with 600 mm embedment h_ef, M30, Steel galvanized, Core drilled (with
Roughening Tool) installation per ETA 20/0541, with annular gaps filled with Hilti Filling Set or any suitable gap solutions
y
300.0 300.0
150.0
5 6
500.0
350.0
3 4
x
350.0
500.0
1 2
150.0
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
10
Hilti PROFIS Engineering 3.0.87
www.hilti.com.au
Company: ARP Engineering Page: 11
Address: Southbank Blvd., Southbank, VIC 3006 Specifier:
Phone I Fax: | E-Mail:
Design: Dual Hoop Date: 11/8/2023
Fastening Point:
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan