You are on page 1of 2

SPECIFICATION FLUE GAS DESULFURIZATION (FGD)

PLTU CELUKAN BAWANG

QUANTITY
NO EQUIPMENT NAME SPECIFICATION
#1 #2 #3 COMMON TOTAL

-Type : Electric Double Sealed type


(with sealed air , 100% sealed
-Dimensions : 6m (width) x 3.94m
#1 FGD (Entrance Barrier Door) (height)
#2 FGD (Entrance Barrier Door) -The Baffle door is installed on
#3 FGD (Entrance Barrier Door) horizontal flue
1 -The actuator is at a height of 3.94m 1 1 1 - 3
-The actuator power is 0.8kW
-Voltage power : 380VAC

#1 #2 #3 FGD INLET DAMPER Electric Uniaxial double damper


(with100%sealed),Size:
6m×3.94m×0.4m

-Type : Electric Double Sealed type


#1 FGD (Exit Baffle Door) (with sealed air , 100% sealed
#2 FGD (Exit Baffle Door) -Dimensions : 3.2m (width) x 5m
#3 FGD (Exit Baffle Door) (height)
-The Baffle door is installed on
2 horizontal flue 1 1 1 - 3
-The actuator is at a height of 5m
-The actuator power is 0.8kW
-Voltage power : 380VAC

Electric Uniaxial double damper


#1/#2/#3 FGD OUTLET DAMPER with100%sealed),
Size: 3.2m×5m×0.4m

Electric double louver sealed type


#1 Bypass flue baffle door (with sealed air, 100% sealed).
#2 Bypass flue baffle door Dimensions: 3.2m (width) × 5m
#3 Bypass flue baffle door (height), the baffle door is installed on
the horizontal flue, the actuator is at a
3 height of 5m, the actuator power is 1 1 1 - 3
0.8kW , voltage 380V

#1/#2/#3 BYPASS DAMPER Electric Uniaxial double


damper(with100%sealed),
Size: 3.2m×5m×0.4m
Centrifugaltype,flow
7766~9500m3/h,staticpressure
DAMPERS EAL AIRBLOWER 6.5~7.2KPa,Motormodel Y-200L-
4 2 2 2 6
#1A/#1B/ #2A/#2B/#3A/#3B 2,Voltage380V,power 30KW;
speed2900r/min,Motor protection
class IP56, F class

5 #1 #2 #3 SEAL AIR ELECTRIC HEATER Voltage380V,power: 160KW , 1 1 1 3


protection classIP56

Non-metal, 4500mm (width) ×


3600mm (height), installation length
300mm, design pressure ±10KPa,
design temperature 300℃, axial
6 compensation ±50mm, radial 1 1 1 3
Original Flue Expansion Joint compensation ±30mm, welded
1A/ 2A/ 3A connection, no anti-corrosion

Size:4500mm×3600mm(H),
RAW GAS DUCT COMPENSATOR Theaxialexpansion: ±
1A/2A/3A 50mm,radialexpansion ± 30mm
Non-metal, Φ4500mm, installation
Original Flue Expansion Joint length 300mm, design pressure
1B/3B ±10KPa, design temperature 300℃,
7 axial compensation ±50mm, radial 1 1 2
compensation ±30mm, welded
connection, no anti-corrosion
RAW GAS DUCT COMPENSATOR Size: Φ4500mm,Theaxial expansion: ±
1B/ 3B 50mm,radial expansion ± 30mm

Non-metal, 6000mm (width) ×


Original Flue Expansion Joint 3940mm (height), design pressure
1C/3C ±10KPa, design temperature 300℃,
axial compensation ±60mm, radial
8 compensation ±30mm, welded 1 1 2
connection, no anti-corrosion

RAW GAS DUCT COMPENSATOR Size:6000mm×3940mm(H),


1C/ 3C Theaxialexpansion: ±
60mm,radialexpansion ± 30mm

Non-metal, 6000mm (width) ×


3940mm (height), design pressure ±
1#/2#/3# Absorption Tower Import 10KPa, design temperature 300°C, axial
Expansion Joint compensation amount ± 50mm, radial
9 compensation amount ± 30mm, 1 1 1 3
welded + flange connection, anti-
corrosion, with drain port DN100

1#/2#/3# ABSORBER INLET Size:6000mm×3940mm(H),Theaxiale


COMPENSATOR xpansion: ±50mm,radialexpansion
±30mm ,With outlet DN100

Non-metal, 3200mm (width) ×


1#/2#/3# Absorption Tower Outlet 5000mm (height), design pressure
Expansion Joint ±10KPa, design temperature 300℃,
axial compensation ±50mm, radial
10 compensation ±30mm, welding + 1 1 1 3
flange connection, anti-corrosion

1#/2#/3# ABSORBER OUTLET Size:3200mm×5000mm(H),


COMPENSATOR Theaxialexpansion: ±
50mm,radialexpansion ± 30mm

Non-metal, 3600mm (length) ×


4500mm (width), design pressure
Bypass flue expansion joint 1A/3A
±10KPa, design temperature 300℃,
axial compensation ±50mm, radial
11 compensation ±70mm, welded 1 1 2
connection, no anti-corrosion

BYPASS GAS DUCT COMPENSATOR 1A/3A Size:3600mm×4500mm(H),


Theaxialexpansion: ±
50mm,radialexpansion ± 70mm
Non-metal, 3600mm (length) ×
4500mm (width), design pressure
Bypass flue expansion joint 2A ±10KPa, design temperature 300℃,
axial compensation ±50mm, radial
12 compensation ±70mm, welded 1 1
connection, no anti-corrosion
Size:3600mm×4500mm(H),
BYPASS GAS DUCT COMPENSATOR 2A Theaxialexpansion: ±
50mm,radialexpansion ± 70mm

Non-metal, 3200mm (width) ×


Bypass Flue Expansion Joint 5000mm (height), design pressure
1B/2B/3B ±10KPa, design temperature 300℃,
axial compensation ±50mm, radial
13 compensation ±30mm, welded 1 1 1 3
connection, no anti-corrosion

BYPASS GAS DUCT COMPENSATOR Size:3200mm×5000mm(H),


1B/2B/3B Theaxialexpansion: ±
50mm,radialexpansion ± 30mm

Non-metal, 2600mm (width) ×


6000mm (height), design pressure ±
1#/2#/3# Chimney Entrance is Swollen 10KPa, design temperature 300°C, axial
compensation amount ± 50mm, radial
14 compensation amount ±150mm, 1 1 1 3
welding + flange connection, anti-
corrosion
Size:2600mm×6000mm(H),
1#/2#/3#STACK INLET COMPENSATOR Theaxialexpansion: ±
50mm,radialexpansion ± 150mm