You are on page 1of 3

Annual Production Report produced by Bangun Solar Global

Design 4 Amazana Apartemen, -6.266644, 106.671365


 Report  System Metrics  Project Location

Project Name Amazana Apartemen Design Design 4

Project Description Flate Roof Module DC


11.0 kW
Nameplate
Project Address -6.266644, 106.671365
Inverter AC 10.00 kW
Bangun Solar Global
Nameplate Load Ratio: 1.10
Prepared By
yayat.hidayat@bsg-solar.id
Annual
11.60 MWh
Production

Performance
59.8%
Ratio

kWh/kWp 1,054.8

Weather TMY, 10km Grid, meteonorm/nasa low


Dataset resolution (meteonorm)

Simulator 6bfc17b1e7-63de027079-3ee2ad6370-
Version bf1416b61b

 Monthly Production  Sources of System Loss

1500
AC System:
System: 0.0%
Inverters: 1.9%
Inverters:

Wiring: 0.2%
Wiring:
1000
Shading: 17.8%
Shading:
Mismatch: 13.2%
Mismatch:
kWh

500

Temperature: 7.5%
Temperature: Reflection: 3.4%
Reflection:
0
Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Irradiance: 2.1%
Irradiance: Soiling: 2.0%
Soiling:

© 2023 Aurora Solar 1/3 October 27, 2023


Annual Production Report produced by Bangun Solar Global

 Annual Production  Condition Set


Description Output % Delta Description Condition Set 1
Annual Global Horizontal Irradiance 1,736.3 Weather Dataset TMY, 10km Grid, meteonorm/nasa low resolution (meteonorm)
POA Irradiance 1,762.7 1.5%
Solar Angle Location Meteo Lat/Lng
Irradiance Shaded Irradiance 1,449.2 -17.8%
(kWh/m2) Transposition Model Perez Model
Irradiance after Reflection 1,399.2 -3.4%
Irradiance after Soiling 1,371.3 -2.0% Temperature Model Sandia Model
Total Collector Irradiance 1,367.9 -0.2% Rack Type a b Temperature Delta
Nameplate 15,067.9 Fixed Tilt -3.56 -0.075 3°C
Output at Irradiance Levels 14,753.2 -2.1% Temperature Model
Parameters Flush Mount -2.81 -0.0455 0°C
Output at Cell Temperature Derate 13,651.6 -7.5% East-West -3.56 -0.075 3°C
Energy Output After Mismatch 11,855.0 -13.2% Carport -3.56 -0.075 3°C
(kWh) Optimal DC Output 11,833.3 -0.2%
J F M A M J J A S O N D
Constrained DC Output 11,833.3 0.0% Soiling (%)
2 2 2 2 2 2 2 2 2 2 2 2
Inverter Output 11,608.5 -1.9%
Irradiation Variance 5%
Energy to Grid 11,603.2 0.0%
Temperature Metrics Cell Temperature
4° C
Spread
Avg. Operating Ambient Temp 27.6 °C
Module Binning Range -2.5% to 2.5%
Avg. Operating Cell Temp 36.1 °C
Simulation Metrics AC System Derate 0.50%

Operating Hours 4520 Module Uploaded By Characterization

Solved Hours 4520 Module ISG-


Characterizations ISG-HCP144 (PT. Indonesia Bangun Solar
HCP144.PAN,
Solar Global) Global
PAN
Component Device Uploaded By Characterization
Characterizations SUN2000-10KTL-M1 (Huawei) HelioScope Spec Sheet

 Components  Wiring Zones

Component Name Count Description Combiner Poles String Size Stringing Strategy
1 (10.00 Wiring Zone - 4-21 Along Racking
Inverters SUN2000-10KTL-M1 (Huawei)
kW)
AC Panels 1 input AC Panel 1
 Field Segments
AC Home 1 (11.5
6 mm2 (Copper) Description Racking Orientation Tilt Azimuth Intrarow Spacing Frame Size Frames Modules Power
Runs m)
AC Home 1 (16.5 Field Segment 1 Fixed Tilt Portrait (Vertical) 10° 0° 0.1 m 1x1 25 25 11.0 kW
10 mm2 (Copper)
Runs m)
2 (48.0
Strings 10 AWG (Copper)
m)
PT. Indonesia Solar Global, ISG- 25 (11.0
Module
HCP144 (440W) kW)

© 2023 Aurora Solar 2/3 October 27, 2023


Annual Production Report produced by Bangun Solar Global

 Detailed Layout

© 2023 Aurora Solar 3/3 October 27, 2023

You might also like