ECENTincrease in power system loads has led such Sk =S k −S k (1)
power system to operate near, even violate, its
acceptable limits. In a short span of operating time horizon, The amount of load shedding per iteration may move
an emergency action is commonly adopted to bring power towards both positive and negative directions. To
system to a secure operating condition. One example of such accommodate this nature, load shedding variable is
emergency action is load shedding where a certain amount of represented by two additional slack variables for both positive
load is required to be shed from the system to improve the and negative directions during iteration process. Therefore
overall performance of the power system. total amount of load shedding at each bus of current iteration
In terms of time horizon, load shedding can be used to is updated by the following equation:
improve both transient (as an emergency action of a special
protection system) and steady state security. As for power shed
−¿ ¿
+¿−Sk ¿
system variables, load shedding is usually carried out in the
Sk =Sk (2)
case of under frequency or under voltage occurs. Examples of
utilizing load shedding for mitigating under frequency Please note that in this work, load power factor remains
conditions are provided in [1], [2]. For mitigating under constant as specified in the input data. In order to maintain
voltage problems, load shedding is utilized in [3]-[9]. power factor at bus k, relationship between active power and
Congestion management is also a class of problem to solve reactive power load held by the following relationship:
using load shedding. Such work was reported in [10].
ρk =tan ( cos ( Pk / √ P 2k + Q2k ))
In this work, voltage at all buses must be within the ±5% −1
(3)
voltage variations from the nominal voltage. In order to
achieve it, a minimum amount of load must be shed from the
system if current loading condition results in under voltage Due to additional slack variables of load shedding,
situation. Therefore, a linear programming-based optimal complex power mismatch equation per iteration in equation
power flow method is utilized to find the location where (4) can be modified by accommodating equation (2) and
minimum load shedding can be carried out to bring bus results in equation (5):
voltage to be within the ±5% limits. This work extends our
previous works as reported in [11], [12] by utilizing polar ∆ S=S scheduled −S calculated (4)
representation of the bus complex voltage. In [12], linear
1
Department of Electrical Engineering, Faculty of Engineering , Universitas Lampung, Bandar Lampung, 35145, Indonesia (e-mail:
plgsekip@eng.unila.ac.id )
2
Department of Electrical Engineering, Faculty of Engineering , Universitas Lampung, Bandar Lampung, 35145, Indonesia (e-mail:
plgsekip@eng.unila.ac.id )
3
Department of Electrical Engineering, Faculty of Engineering , Universitas Lampung, Bandar Lampung, 35145, Indonesia (e-mail:
plgsekip@eng.unila.ac.id )
4
Department of Electrical Engineering, Faculty of Engineering , Universitas Lampung, Bandar Lampung, 35145, Indonesia (e-mail:
plgsekip@eng.unila.ac.id )
spec
−¿=S gen−Sload−Scalculated ¿
+¿+Sload ¿
∆ S−S load (5)
Objective function:
−¿
−¿∙ P ¿
min . ∑ C
+¿+ C k k
¿
+¿ ∙ Pk ¿
k ¿
k ∈K (6)
Subject to:
V =V + ∆ V (8)
θ=θ+∆ θ (9)
Fig. 1. Voltage profile of base case scenario of IEEE 57-bus
REFERENCES
Das, K., Nitsas, A., Altin, M., Hansen, A.D., Sorensen, P.E., “Improved load
Fig. 3. Voltage profile of modified loading scenario of IEEE 57-bus
shedding scheme considering distributed generation,” IEEE Trans. on Power
Delivery, vol. 32, no. 1, Feb. 2017, pp. 515-524.
[1] Hirodontis, S., Crossley, P.A., “Load shedding in a distribution
network,” Proc. of 2009 Int’l Conf. on SUPERGEN, Nanjing, 6-7 April
2009
[2] Pushpendra Singh, Titare, L.S., Arya, L.D., Choube, S.C., “Strategy to
Optimize the Load Shedding Amount Based on Static Voltage Stability
using SFLA,” Proc. of 2016 Biennial Int’l. Conf. on PESTSE,
Bangalore, 21-23 Jan. 2016
[3] Echavarren, F.M., Lobato, E., Rouco, L., “A corrective load shedding
scheme to mitigate voltage collapse,” Int’l Journal of Electrical Power
and Energy Systems, vol. 28, no. 1, 2006, pp. 58-64
[4] Perumal, N., Amran, A.C., “Automatic load shedding in power
system,” Proc. of 2003 Power Engineering Conference, Bangi, 15-16
Dec. 2003.
[5] Wang, Y., Pordanjani, I.R., Li, W., Xu, W., Vaahedi, E., “Strategy to
minimize the load shedding amount for voltage collapse prevention,”
IET Gen. Trans. & Dist., vol. 5, no. 3, March 2011, pp. 307-313.
[6] Aziah, K., Shareef, H., Mohamed, A., “Islanding detection and load
Fig. 4. Voltage profile of modified loading scenario of IEEE 57-bus after shedding scheme for radial distribution systems integrated with
dispersed generations,” IET Gen. Trans. & Dist., vol. 9, no. 15, Nov.
load shedding
2015, pp. 2261-2275.
[7] Kaffashan, I., Amraee, T.,”Probabilistic undervoltage load shedding
using point estimate method,” IET Gen. Trans. & Dist., vol. 9, no. 15,
Nov. 2015, pp. 2234-2244.
TABLE 1. LOCATION AND AMOUNT OF LOAD SHEDDING REQUIRED
[8] Dehghan, S., Darafshian-Maram, M., Shayanfar, H.A., Kazemi, A.,
“Optimal load shedding to enhance voltage stability and voltage profile
Active Power Load based on a multi-objective optimization technique,” Proc. of 2011 IEEE
Bus # Reactive Power Load Shedding
Shedding PowerTech, Trondheim, 19-23 June 2011.
31 5.24 MW 2.62 MVAr [9] Surender Reddy, S., “Multi-objective based Congestion Management
33 2.39 MW 1.19 MVAr using Generation Rescheduling and Load Shedding,” IEEE Trans. on
42 0.25 MW 0.16 MVAr Power Systems, vol. 32, no. 2, May 2016, pp. 852-863.
57 3.73 MW 1.11 MVAr [10] Hakim, L., Wahidi, M., Handoko, T., Gusmedi, H., Soedjarwanto, N.,
Milano, F.,”Development of a power flow software for distribution
system analysis based on rectangular voltage using python software
package,” Proc. of 2014 ICITEE, Yogyakarta, 7-8 Oct. 2014.
[11] Hakim, L., Murdika, U., Gusmedi, H., Zaini, S., “A study on reactive
power allocation for electrical power distribution system with low
IV. CONCLUSIONS voltage profile,” ARPN Journal of Engineering and Applied Sciences,
System suffers from low voltage magnitude profile or vol. 11, no. 7, April 2016, pp. 4767-4771.
[12] Dabbagchi, I., Christie, R., ”Power System Test Case Archive: 57 Bus
experiences under voltage condition, requires an emergency Power Flow Test Case,” University of Washington Electrical
action to bring such system to an acceptable operating region. Engineering, Washington, August 1993 [Online]. Available:
In this work, load shedding is proposed as the control action https://www2.ee.washington.edu/research/pstca/pf57/pg_tca57bus.htm