SPECIFICATIONS: OFFICE OF THE BUILDING OFFICIAL

1. ALL PLUMBING WORKS INCLUDED HEREIN SHALL BE EXECUTED ACCORDING TO THE


PROVIDING OF THE BUILDING CODE AND THE RULES AND REGULATIONS. 1/2"Ø COLD WATER
PIPE LINE RISER
1 2 3 4 5 6
2. COORDINATE THE DRAWINGS WITH THE OTHER RELATED DRAWINGS 7 SPECIFICATIONS.
THE ARCHITECT/ ENGINEER SHALL BE NOTIFIED IMMEDIATELY OF ANY DISCREPANCY.
3. PIPES SHALL BE INSTALLED AS SHOWN ON PLAN, ANY RELOCATION REQUIRED FOR
PROPER EXECUTION OF OTHER TRADES SHALL BE WITH PRIOR APPROVAL OF THE
ARCHITECT OR ENGINEER.
4. PROPOSED SANITARY UTILITIES SHALL CONFORM THE ACTUAL LOCATION DEPTH &
INVERT ELEVATIONS OF THE PIPES & STRUCTURE.
5. ALL SLOPES FOR SEWER HORIZONTAL BRANCHES SHALL MAINTAIN 2% UNLESS
OTHERWISE NOTED.
W1 W1 W1
6. ALL FIXTURES & TRAPS MUST BE PROVIDED WITH INDIVIDUAL/ CIRCUIT VENTS UNLESS
OTHERWISE INDICATED THERE SHALL BE REQUIRED VENTILATION & LIGHTING SYSTEM FOR 1/2"Ø COLD WATER PIPE LINE
TOILET & BATHROOMS.
7. ALL SLEEVES SHALL BE PROVIDED IN ALL WALLS, COLUMNS, OE SLABS GREATER THAN
THE ACTUAL LINES PASSING THROUGH WALLS & UNDER SLABS TO PROTECT PIPES FROM
BREAKAGE.
8. ALL SEWER LINES 7 WASTE PIPES) & VENT PIPING SYSTEMS SHALL BE UNPLASTICISED
POLYVINYL CHLORIDE PIPES (PVC) CONFORMING TO ASST. 2728 OR ISO.
9. ALL WATER DISTRIBUTION LINES (COLD WATER LINES) SHOULD BE UNPLASTICISED POLYVINYL
CHLORIDE PIPES MANUFACTURED ACCORDING TO ISO-R-161. D2
D2 D3
10. STORM DRAINAGE PIPE SHALL BE CONCRETE FOR SIZES cc% ABOVE CONFORMING TO ASTM
76 CLASS II RESPECTIVELY. D3 3"Ø WASTE PIPE LINE
11. ALL PVC PIPES SIZES FOR WATER & SEWER LINES ARE IN NOMINAL OUTSIDE DIAMETER 4"Ø SOIL PIPE RISER D2
(ISO STANDARD). 15
12. ALL EXPOSES AND MAIN WATER SUPPLY LINE SHALL BE G.I. PIPES SCHEDULE 40. 3"Ø WASTE PIPE LINE 14

13. ALL PLUMBING WORKS SHALL BE DONE BY AN EXPERIENCED PLUMBER UNDER THE DIRECT D2
13

SUPERVISION OF A COMPETENT SANITARY ENGINEER. D2 12


11
10
93"Ø WASTE PIPE RISER

D3
8
4"Ø SOIL PIPE RISER 7
D3 6
5
4
3
2
1
W1 W1 W2

SYMBOLS: W1

CO -CLEAN OUT CB -CATCH BASIN


DS -DOWN SPOUT
3"Ø WASTE PIPE RISER
WC -WATER CLOSET
LAV. -LAVATORY
-CHECK VALVE
FD -FLOOR DRAIN
-FOOT BATH COLD WATER PIPE LINE
FB
SOIL PIPE LINE
F -FAUSET

S
VTR
-SHOWER
-VENT TRHU ROOF

-SEPTIC VAULT
WASTE PIPE LINE
DRAINAGE PIPE LINE
SECOND FLOOR
PLUMBING LAYOUT
SV -GATE VALVE
SCALE: 1:80 MTR

CERTIFIED BY: PRC NO. D R Y S E A L APPROVED BY: CAD BY: CF REVISIONS : SHEET CONTENTS :

PTR NO. PROPOSED 3-STOREY RESIDENTIAL BUILDING


WITH ROOF DECK AND RETAILER
CHECKED BY:
DESIGNED BY:
1.
2.
P
DATE ISSUED. DATE START 3.

TIN. NO.
LOCATION OF CONSTRUCTION:

OWNER'S SIGNATURE
OWNER
DATE FINISHED
REFERENCE:
4.
1 4