Professional Documents
Culture Documents
* ALL INSTALLATION HEREIN SHALL CONFORM WITH THE RULES & REGULATION
1 2 3 4 5 6
OFFICE OF THE BUILDING OFFICIAL
CATCHMENT TANK
OF THE NATIONAL PLUMBING CODE AND LOCAL ORDINANCES.
* PVC PIPES & FITTING FOR SANITARY PIPE LINES EXCEPT FOR WASTE 7
CORRESPONDING VENT SHERE GALVANIZED MAY BE USED. A
* GALVANIZED IRON PIPES 7 FITTINGS FOR ALL WATER SUPPLY & DISTRUBUTION 3"Ø WASTE PIPE LINE
PIPE SYSTEM THREADED UNITS. D1
* NO PIPES SMALLER THAN S40 GA SHALL BE USED. B
* ALL INSTALLATION HERIN SHALL BE UNDER THE DIRECT SUPERVISION OF A
DULY LICENSED SANITARY ENGINEER OR MASTER PLUMBER.
1. ALL PLUMBING WORKS INCLUDED HEREIN SHALL BE EXECUTED ACCORDING TO THE
PROVIDING OF THE BUILDING CODE AND THE RULES AND REGULATIONS.
2. COORDINATE THE DRAWINGS WITH THE OTHER RELATED DRAWINGS 7 SPECIFICATIONS.
THE ARCHITECT/ ENGINEER SHALL BE NOTIFIED IMMEDIATELY OF ANY DISCREPANCY.
3. PIPES SHALL BE INSTALLED AS SHOWN ON PLAN, ANY RELOCATION REQUIRED FOR
PROPER EXECUTION OF OTHER TRADES SHALL BE WITH PRIOR APPROVAL OF THE
ARCHITECT OR ENGINEER.
LINE
4. PROPOSED SANITARY UTILITIES SHALL CONFORM THE ACTUAL LOCATION DEPTH &
INVERT ELEVATIONS OF THE PIPES & STRUCTURE. C
WASTE PIPE
5. ALL SLOPES FOR SEWER HORIZONTAL BRANCHES SHALL MAINTAIN 2% UNLESS
OTHERWISE NOTED.
6. ALL FIXTURES & TRAPS MUST BE PROVIDED WITH INDIVIDUAL/ CIRCUIT VENTS UNLESS
OTHERWISE INDICATED THERE SHALL BE REQUIRED VENTILATION & LIGHTING SYSTEM FOR D
3"Ø
TOILET & BATHROOMS.
7. ALL SLEEVES SHALL BE PROVIDED IN ALL WALLS, COLUMNS, OE SLABS GREATER THAN
THE ACTUAL LINES PASSING THROUGH WALLS & UNDER SLABS TO PROTECT PIPES FROM
BREAKAGE.
8. ALL SEWER LINES 7 WASTE PIPES) & VENT PIPING SYSTEMS SHALL BE UNPLASTICISED
PIPE LINE
POLYVINYL CHLORIDE PIPES (PVC) CONFORMING TO ASST. 2728 OR ISO.
9. ALL WATER DISTRIBUTION LINES (COLD WATER LINES) SHOULD BE UNPLASTICISED POLYVINYL
CHLORIDE PIPES MANUFACTURED ACCORDING TO ISO-R-161.
10. STORM DRAINAGE PIPE SHALL BE CONCRETE FOR SIZES cc% ABOVE CONFORMING TO ASTM
76 CLASS II RESPECTIVELY.
PIPE LINE
E
SOIL
11. ALL PVC PIPES SIZES FOR WATER & SEWER LINES ARE IN NOMINAL OUTSIDE DIAMETER
LINE
(ISO STANDARD).
4"Ø
12. ALL EXPOSES AND MAIN WATER SUPPLY LINE SHALL BE G.I. PIPES SCHEDULE 40.
WASTE PIPE
13. ALL PLUMBING WORKS SHALL BE DONE BY AN EXPERIENCED PLUMBER UNDER THE DIRECT
SUPERVISION OF A COMPETENT SANITARY ENGINEER.
SOIL
F
1/2"Ø COLD WATER PIPE LINE
3"Ø
4"Ø
4"Ø SOIL PIPE LINE
WC -WATER CLOSET
LAV. -LAVATORY TO MAIN WATER
-CHECK VALVE
FD -FLOOR DRAIN SOURCE
-FOOT BATH COLD WATER PIPE LINE
FB
SOIL PIPE LINE
F -FAUSET
WASTE PIPE LINE
S -SHOWER
VTR -VENT TRHU ROOF DRAINAGE PIPE LINE
CERTIFIED BY: PRC NO. D R Y S E A L APPROVED BY: CAD BY: CF REVISIONS : SHEET CONTENTS :
TIN. NO.
LOCATION OF CONSTRUCTION:
OWNER'S SIGNATURE
OWNER
DATE FINISHED
REFERENCE:
4.
2 4