Design and Optimization of Unified Power Flow

Controller (UPFC) based on IEEE 9 Bus System


2022 6th International Conference on Electrical, Telecommunication and Computer Engineering (ELTICOM) | 979-8-3503-2071-8/22/$31.00 ©2022 IEEE | DOI: 10.1109/ELTICOM57747.2022.10037889

Surya Hardi, Ph.D Suherman, Ph.D Rahmat Ridho


Department of Electrical Engineering Department of Electrical Engineering Department of Electrical Engineering
Universitas Sumatera Utara Universitas Sumatera Utara Universitas Sumatera Utara
Medan, Indonesia Medan, Indonesia Medan, Indonesia
surya.hardi@usu.ac.id suherman@usu.ac.id rahmatridho393@gmail.com

Abstract— In a modern electrical system network, synchronism which in turn can cause the power system to fail
congestion can occur due to lack of coordination between supply or collapse (collapse). If this happens, the operation of
and demand to increase the burden of current transmission electrical energy will be disrupted, especially when peak loads
users. The system no longer works inside its warm breaking occur. Thus, it is necessary to evaluate by adding tools to the
point. Unified Power Flow Controller (UPFC) assumes a vital electric power system to maintain the stability of the electric
part in the power system to upgrade the exhibition of existing power system[2].
lines as well as to work on the security of the framework. UPFC
ought to be found ideally because of high capital venture. In this In order to improve the stability of the power system, an
paper, the optimization of UPFC is gotten by awareness based effective technology is needed to optimize the stability of the
approach as far as change in active power flow sensitivity in system when operating. One technology to improve the
order to improve the framework execution with IEEE 9 stability of the current system is the Flexible AC Transmission
bussystem and the validation of the framework is approved by System (FACTS). The FACTS device is a device designed for
Power World Test Simulator Software 19.0. flexible and high-accuracy control and regulation of
transmission systems.
Keywords—Flexible AC Transmission Systems (FACTS), UPFC,
Voltage Stability, Power World One of the FACTS devices that are often used is the UPFC
(Unified Power Flow Controller) which is the third generation
I. INTRODUCTION of FACTS technology. This UPFC is an integration of the
The process of growing electricity users over time will previous generation of FACTS devices, namely Static
increase the demand for electrical energy [1]. According to Synchronous Compensator (STATCOM) and Static
data from the 2021-2030 Electric Power Supply Business Plan Synchronous Series Compensator (SSSC) [3]. STATCOM is
(RUPTL), the realization of the number of customers during usually used to maintain voltage stability, with additional
2011-2020 has increased from 45.6 million to 78.7 million or equipment can also be used to improve dynamic performance
an average of 3.7 million annually. The largest addition of [3].
customers still occurred in the household sector, which was an SSSC is basically a serialized version of STATCOM.
average of 3.3 million per year, followed by the business These devices are connected in series and can control the flow
sector with an average of 215 thousand subscribers per year, of power from the desired line and can be used to increase the
the public sector with an average of 116 thousand subscribers attenuation of the system. UPFC as a Flexible AC
per year, and the industrial sector on average of 9 thousand Transmission System (FACTS) device is able to provide
consumer per year. voltage regulation, phase shift, series compensation and shunt
This makes the manager of electric energy plants have to compensation functions that can be performed simultaneously
increase the number of generating units and the number of and in real-time [4]. This study plans to place the UPFC
transmission lines. In an electrical system that has a high location on the 9 bus system and simulate the power flow
complexity, the process of distributing electrical energy from system using applications from Power World.
the generator to the consumer must have good system
stability. II. MODELLING OF UPFC
The static modelling of UPFC is developed for steadystate
The North Sumatra interconnection system is supplied by
condition. UPFC is a combination of series and
PLN, Independent Power Producer (IPP), and swap energy
with PT. Inalum as well as some excess power to help meet shuntconverters. UPFC has three control parameter, voltage
peak load needs. The highest peak load of North Sumatra in (VS), series insertion angle (Φs) and shunt current component
2020 is 1,883 MW. Therefore, in maintaining the stability of (Iq) is in quadrature with voltage Vi at UPFC ith bus [5].
the electric power system in the transmission network, it is The equivalent circuit of line including UPFC is as shown
planned to build 170-kilometer circuits (kms) in 2022 for 150 in fig 1.The apparent powers of a line including UPFC are
KV transmission in North Sumatra [1]. given
The stability of the electric power system is a characteristic as
of the power system that allows the engine to move Pis = -Vs2gi j – 2ViVsgi j cos (Øs–δi)
synchronously in the system in normal operation and can + Vj Vs [gij cos (Øs – δj)
return to a balanced state after a disturbance. Instability of the + bij sin(Øs - δj)] (1)
system can cause the generator at the power plant to lose

979-8-3503-2071-8/22/$31.00 ©2022 IEEE


ELTICOM 2022 66
Authorized licensed use limited to: Universidad de la Frontera. Downloaded on October 24,2023 at 00:39:06 UTC from IEEE Xplore. Restrictions apply.
III. ACTIVE POWER FLOW SENSITIVITY INDEX APPROACH
The genuine power stream awareness record (PI)
reliesupon the presentation of the line under typical
andpossibility conditions. The way of behaving of
theloadability of the organization condition can be made
senseof by a functioning power stream awareness record (PI)
Fig. 1. Injection model of FACTS controller [7],strategy.

PI = ∑
Qis = ViIq+ViVs[gi j sin (Øs – δi) + bijcos(Øs– δi) (2)
(5)
Pjs = VjVs [gi j cos (Øs – δj) - bij sin(Øs - δj)] (3)
Were,
Qjs = -VjVs[gi j sin (Øs – δj) + bijcos(Øs– δj)] (4) Nl = Total number of lines in the system
Wm = Real nonnegative weighting coefficient = 1
A. Power Flow Model of UPFC in Power World Pmax = Maximum loading capacity of the line
SimulatorSoftware Plm = Actual power flow in the line
A Comprehensive model is designed based on the n = exponant = 2
controlparameters such as real power, reactive power as well
asvoltages at bus must be simultaneously control [6]. A The seriousness in light of the stacking states of the
uniquesolution can be provided for the security of the organization under the consistent state and possibility cases.
network forthat purpose the active power or one of reactive The framework execution is examine in light of awareness
power orvoltage of every bus should be known. Power flow approach. During consistent state condition the PI esteem is
solutionwould be constant if the connected element to the little and it is worked inside its warm cut off[8].
desired busact as neutral to bus parameters.UPFC is Meanwhile, when the over-loading condition reaches the
connected in thelinealways maintained the voltage (VEt ) in value of the increase in PI. The resulting record for dynamic
sending bus i andinject PBt- QBt at receiving bus j as shown in power flow responsiveness was determined considering the
Fig.2. conditions above regarding the size of the series inclusion
voltage as the UPFC control limit which is placed on each
channel in turn due to cost feasibility [9].
It ought to be found ideally. For concluding the portion of
UPFC, the most regrettable responsiveness file line is the
appropriate designation for UPFC situation for further
developing the framework execution and one more measures
can likewise be utilized for UPFC while concluding the
distribution isn't be put with producing transformer despite
Fig. 2. Network control by UPFC the fact that the most bad awareness record[10].

Expecting misfortune free UPFC, the infused and retained IV. SIMULATION RESULTS
influence values to transport I and j would be equivalent as
displayed in fig .3. The PEt (P-Exciter) and Vet (V-Exciter) In elaborating on the proposed strategy for confident
are the known upsides of the UPFC sending end. execution of the UPFC ideally examined on a customized
IEEE 9 system bus in Power World programming. Transport
1 is taken as concession transportation. Based on the power
flow investigation data, the authors observe that channels 4-
6 are abusing their hot disconnects.
Efforts made to reduce overload for framework safety
edge without rescheduling age or changing organization
geography to find valid UPFC designation by PI file
considering original power flow was specified regarding
steady state surcharge as UPFC control limit set in each
respective line in turn for a similar working state. UPFC
related PI response files are introduced in Table I.
Fig. 3. Static Model of UPFC
From Table I, the sensitivity index with respect to Vs
In power world test system programming, as per UPFC forline 5-7 is having most negative sensitivity index and it
model an extra transport to be included the organization when isindicated in bold. So, it is suitable for the placement
UPFC is executed at the sending or at the less than desirable ofUPFCin line 5-7 to alleviate the overloading and
finish of the transmission network [6]. On the off chance that alsoenhance the system performance. The results are
UPFC is introduced at the center of the line, two transports to Validated byusing Power world simulator software 1.0.
be included the organization.

ELTICOM 2022 67
Authorized licensed use limited to: Universidad de la Frontera. Downloaded on October 24,2023 at 00:39:06 UTC from IEEE Xplore. Restrictions apply.
TABLE I. SENSITIVITY INDEX FOR UPFC ON IEEE BUS
SYSTEM WHEN LINE 4-6 IS IN OVERLOAD SITUATION

S.No Line No. ə


=
ə
1 1-3 -1.153189506
2 2-4 -1.020868964
3 2-5 -3.681277585
4 2-6 -3.881693115
5 3-4 -0.668768017
6 5-7 -8.508273958

Fig.4 shows the framework is in blockage state under


consistent state condition. Fig.5 shows that when an UPFC Fig. 5. UPFC implemented in line 1-3 on 9 bus system
set in line 1-3 it lessens the over-burdening in line 4-6 from
104% to 101%. Fig .6 shows after execution of UPFC in line
2-4 , the line stacking cutoff to 101% . Comparable outcome
is acquired when UPFC is associated in line 2-5 as displayed
in Fig. 7.
Fig. 8 shows the line stacking is diminishes to 101%
subsequent to carrying out UPFC in line 3-4. Fig 10
demonstrates that it decreases the over-burdening in line 4-6
from 104% to 97% and the power stream demonstrated in
green variety bolts implies it works inside its warm breaking
point. In this way, line 5-7 is the best area of UPFC position
as per awareness record and it is approved by power world
test system programming for upgrading the framework
execution. From Table II, it shows that the prior to
introducing UPFC and subsequent to introducing the over-
burdening circumstance. Fig. 6. UPFC placed in line 2-4 on 9 bus system

TABLE II. OVERLOADING SITUATION BEFORE AND AFTER


PLACINGUPFC
Loading after
Line Overloading Before
Fig No. installing UPFC
No. placing UPFC (%)
(%)
4-6 Fig 4. 104 % -
1-3 Fig 5. 104 % 101 %
2-4 Fig 6. 104 % 101 %
2-5 Fig 7. 104 % 100 %
3-4 Fig 8. 104 % 101 %
5-7 Fig 9. 104 % 97 %

Fig. 7. line 2-5 with UPFC

Fig. 4. Modified IEEE 9 bus system with line 4-6 overload condition

Fig. 8. line 3-4 having UPFC

ELTICOM 2022 68
Authorized licensed use limited to: Universidad de la Frontera. Downloaded on October 24,2023 at 00:39:06 UTC from IEEE Xplore. Restrictions apply.
Bayesian approach”, Global energy interconnection, pp. 217-266,
2020.
[3] R. Gianto, “Application of STATCOM in Improving Dynamic
Performance of Interconnected Electric Power System,” IPASJ
International Journal of Electrical Engineering, vol. 5, no. 6, pp. 1-8,
2017.
[4] Qi Wanchun, Yang Lin, Song Pengcheng, “UPFC system control
strategy research in Nanjing western power grid”, Power Systems
Technology, vol. 40, no.1, pp.92-96, 2016.K. Elissa, “Title of paper if
known,” unpublished.
[5] J. G. Singh, S. N. Singh, S. C. Srivastava, “Optimal Placement
ofUnified Power Flow Controller Based on System
LoadingDistribution Factors.”, Electric Power Components and
Systems,37:4, pp.441-463.
[6] A. Kazemi, A. Esmaielie, M. T. Hassanzade, and R. Rezaiepour,
“Acomprehensive load flow model for UPFC and its combination
withESS,” International conference on Electrical and Elecronics
Fig. 9. UPFC allocated in line 5-7 Engg.ELECO-2008, Aug 26, 2008.
[7] K.S. Verma, S.N. Singh, H.O. Gupta, “Location of unified powerflow
V. CONCLUSION controller for congestion management.”, Electric Power
SystemsResearch 58 (2001) 89–96.
In this paper, test results got on changed IEEE 9 bus [8] Elsaharty, M. A., Luna, A., Candela, J. I., & Rodriguez, P,” A Unified
system for improving the framework execution in view of Power Flow Controller Using a Power Electronics Integrated
responsiveness approach for distribution of UPFC in a line in Transformer”, IEEE Transactions on Power Delivery, vol. 34, no.3, pp.
light of dynamic power stream execution file in order to 828–839, 2019.
decrease the over-burdening condition. Line 5-7 is the best [9] Huang, H., Zhang, L., Oghorada, O., & Mao, M, “Analysis and Control
of a Modular Multilevel Cascaded Converter-Based Unified Power
area for the execution of UPFC according to most bad Flow Controller”, IEEE Transactions on Industry Applications, vol. 57,
responsiveness file and it is approved in power world test no.3, pp. 3202–3213, 2021.
system programming 19.0. [10] Oo, M. M., & Thuzar, M,”Transmission Capacity Improvement Using
Unified Power Flow Controller with New Control
REFERENCES Strategy”,International Journal of Electrical and Electronic
Engineering and Telecommunications, vol. 10, no.3, pp. 225–232,
2017.
[1] PT PLN (Persero), Rencana Usaha Penyediaan Tenaga Listrik
(RUPTL) PT PLN (Persero) 2021-2030. Jakarta: PT PLN, 2021, pp.
IV(13-14). Diakses melalui www.pln.co.id pada 11 Maret 2022.
[2] H.M. Higgins, dkk, “The Unified Power Flow Controller: A New
Approach To Power Transmission Control Quantifying veterinarians’
beliefs on disease control and exploring the effect of new evidence: A

ELTICOM 2022 69