You are on page 1of 2

Name: _______________________________ 8.

For sleeping departments of hospitals,


RA 9514 Quiz what is the minimum area that needs
JPT Review Center (Arch. Pedro Santos Jr.) to be allotted per person in the
determination of the occupant load,
1. Which is required for building permits? based on RA 9514?
a. FALAR 1 a. 1.40sqm
b. FALAR 2 b. 1.90sqm
c. FALAR 3 c. 11.10sqm
d. FALAR 4 d. 22.30sqm

2. Which is required for occupancy 9. For the basement level of a store that
permits? is used for back-of-house offices, how
a. FALAR 1 much area per person should be
b. FALAR 2 allotted based on RA 9514?
c. FALAR 3 a. 2.80sqm
d. FALAR 4 b. 5.60sqm
c. 9.30sqm
3. Which is required for business d. 18.60sqm
permits?
a. FSEC 10. Based on RA 9514, how many exits
b. FSIC are required if the occupant load is
c. FALAR 1 600?
d. FALAR 4 a. 1 exit
b. 2 exits
4. FALAR 3 applies to buildings whose c. 3 exits
occupant load is at least d. 4 exits
a. 50
b. 100 11. Minimum ramp width, according to RA
c. 200 9514.
d. 500 a. 915mm
b. 1120mm
5. What is the minimum tread required c. 1200mm
for new stairs in RA 9514? d. 1420mm
a. 180mm
b. 200mm 12. The minimum tread for existing stairs,
c. 250mm according to RA 9514.
d. 280mm a. 200mm
b. 230mm
6. What is the minimum riser height c. 250mm
required for new stairs in RA 9514? d. 280mm
a. 100mm
b. 180mm 13. This document is issued by the Fire
c. 200mm Department upon determination that
d. None of the above the design and specifications are in
accordance with the provisions of the
7. Which handrail height NOT allowed by Fire Code.
RA 9514? a. FALAR 1
a. 760mm b. FALAR 2
b. 770mm c. FSIC
c. 850mm d. FSEC
d. 870mm
14. Any visual or audible signal produced
by a device or system to warn the
occupants of the building or fire d. Class D
fighting elements of the presence or
danger of fire 20. A type of standpipe system in which
a. Annunciator panel the pipes are normally not filled with
b. Fire signal water. Water is introduced into the
c. Fire alerting system system thru fire service connections
d. Fire alarm when needed.
a. Wet standpipe
15. An integrated network of hydraulically b. Dry standpipe
designed piping system installed in a c. Combination standpipe
building, structure or area with outlets d. Both A and C
arranged in a systematic pattern which
automatically discharges water when
activated by heat or combustion
products from a fire.
a. Standpipe system
b. Fire extinguishing system
c. Sprinkler system
d. None of the above

16. Results of the annual fire pump flow


test, the annual main drain test, and
the standpipe water flow test should
be included in the:
a. FALAR 1
b. FALAR 2
c. FALAR 3
d. FSEC

17. Fires in cooking appliances that involve


combustible cooking media (vegetable
or animal oils and fats) are classified
as:
a. Class K
b. Class D
c. Class B
d. Class A

18. An integrated piping system connected


to a source of extinguishing agent
which suppressed fires when actuated
by its automatic detecting device
a. Standpipe system
b. Automatic fire suppression
system
c. Fire extinguisher
d. Fire hose

19. Fires involving energized electrical


equipment are classified as:
a. Class A
b. Class B
c. Class C