Calculation of Glass Strength Against Wind Pressure
a. Building = CLUB HOUSE Building (J26)
b. Type of glass = STOPSOL GLASS = STOPSOL Glass c. Glass thickness ( t ) = = 10,00 mm (Design) d. Allowable load = = 1.000,00 kg (Table 1 Allowable Loads of Flat Glasses - Page 56) d. Average load = = 2.500,00 kg (Table 1 Allowable Loads of Flat Glasses - Page 56) 1 Area of glass ( A ) = 2.000 x 1.800 = 3,60 m2 (Design) Allowable wind pressure = Average load / Area of glass = 694,44 kg/m2 10,9m (as module J26) 2 Glass position ( h ) = = 12,12 m' (Design) 13,57m (top module) 3 Velocity of wind ( Q ) = = 223,88 kg/m2 3,1 Normal wind velocity ( V ) = = 59,85 m/s 3,2 Unnormal wind velocity (taifun) ( V ) = = 62,41 m/s 3,3 Length of building ( L ) = = 69,15 m' (Design) 3,4 Height of building ( H ) = terhadap muka tanah = 14,61 m' (Design) 4 Coefficient of wind force ( C ) = (i) When the building is 31 m height or lower Coefficient of wind force ( C ) = = 0,80 (ii) When the building height exceeds 31 m Building ratio = L/H = 4,73 ( a ) = H / 10 = 1,46 ( b ) = L/8 = 8,64 Coefficient of wind force ( C Pos ) = = 0,80 (Table 2 Value of C - Page 57) Coefficient of wind force ( C Neg ) = = (1,50)
5 Design wind pressure ( P ) = C Pos x Q = 179,11 kg/m2
6 Design load ( W ) = PxA = 644,78 kg 7 Glass thickness ( t ) = = 10,00 mm OK 8 The ralationship among wind pressure, glass area, glass thickness and a safety factor on the basis of wind pressure breaking test result Single Glass 8,1 Safety factor ( F ) = = 3,30 (Design) (Table 4 Safety Factor and Failure Probability - Page 58) 8,2 Constant value spesific to single glass ( K ) = = 80,00 (Table 3 Value of K - Page 58) 8,3 Area of glass ( A ) = = 3,60 m2 8,4 Allowable wind pressure ( P ) = (K / (FxA)) x (t + ((t^2)/4)) = 179,11 kg/m2 8,5 Glass thickness ( t ) = = 10,00 mm