You are on page 1of 3

Annual Production Report produced by Bangun Solar Global

Design 1 Amazana Apartemen, -6.266644, 106.671365


 Report  System Metrics  Project Location

Project Name Amazana Apartemen Design Design 1

Project Description Flate Roof Module DC


36.1 kW
Nameplate
Project Address -6.266644, 106.671365
Inverter AC 36.0 kW
Bangun Solar Global
Nameplate Load Ratio: 1.00
Prepared By
yayat.hidayat@bsg-solar.id
Annual
47.85 MWh
Production

Performance
75.2%
Ratio

kWh/kWp 1,326.1

Weather TMY, 10km Grid, meteonorm/nasa low


Dataset resolution (meteonorm)

Simulator 6bfc17b1e7-63de027079-3ee2ad6370-
Version bf1416b61b

 Monthly Production  Sources of System Loss

6k
AC System:
System: 0.1% Shading: 0.0%
Shading:
Inverters: 1.6%
Inverters: Reflection: 3.4%
Reflection:

Wiring: 0.3%
Wiring: Soiling: 2.0%
Soiling:
4k
Mismatch: 3.2%
Mismatch:
kWh

Irradiance: 1.5%
Irradiance:

2k

0
Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Temperature: 15.0%
Temperature:

© 2023 Aurora Solar 1/3 October 27, 2023


Annual Production Report produced by Bangun Solar Global

 Annual Production  Condition Set


Description Output % Delta Description Condition Set 1
Annual Global Horizontal Irradiance 1,736.3 Weather Dataset TMY, 10km Grid, meteonorm/nasa low resolution (meteonorm)
POA Irradiance 1,762.7 1.5%
Solar Angle Location Meteo Lat/Lng
Irradiance Shaded Irradiance 1,762.7 0.0%
(kWh/m2) Transposition Model Perez Model
Irradiance after Reflection 1,702.4 -3.4%
Irradiance after Soiling 1,668.3 -2.0% Temperature Model Sandia Model
Total Collector Irradiance 1,668.3 0.0% Rack Type a b Temperature Delta
Nameplate 60,310.1 Fixed Tilt -3.56 -0.075 3°C
Output at Irradiance Levels 59,375.8 -1.5% Temperature Model
Parameters Flush Mount -2.81 -0.0455 0°C
Output at Cell Temperature Derate 50,467.2 -15.0% East-West -3.56 -0.075 3°C
Energy Output After Mismatch 48,835.4 -3.2% Carport -3.56 -0.075 3°C
(kWh) Optimal DC Output 48,669.3 -0.3%
J F M A M J J A S O N D
Constrained DC Output 48,669.3 0.0% Soiling (%)
2 2 2 2 2 2 2 2 2 2 2 2
Inverter Output 47,890.6 -1.6%
Irradiation Variance 5%
Energy to Grid 47,846.2 -0.1%
Temperature Metrics Cell Temperature
4° C
Spread
Avg. Operating Ambient Temp 27.6 °C
Module Binning Range -2.5% to 2.5%
Avg. Operating Cell Temp 48.2 °C
Simulation Metrics AC System Derate 0.50%

Operating Hours 4520 Module Uploaded By Characterization

Solved Hours 4520 Module ISG-


Characterizations ISG-HCP144 (PT. Indonesia Bangun Solar
HCP144.PAN,
Solar Global) Global
PAN
Component Device Uploaded By Characterization
Characterizations SUN2000-36KTL-M3 (Huawei) HelioScope Spec Sheet

 Components  Wiring Zones

Component Name Count Description Combiner Poles String Size Stringing Strategy
1 (36.0 Wiring Zone 6 6-21 Along Racking
Inverters SUN2000-36KTL-M3 (Huawei)
kW)
AC Panels 1 input AC Panel 1
 Field Segments
AC Home 1 (14.5
16 mm2 (Copper) Intrarow Frame
Runs m) Description Racking Orientation Tilt Azimuth Frames Modules Power
Spacing Size
AC Home 1 (19.6
35 mm2 (Copper) Field Segment Flush Landscape 36.1
Runs m) 10° 0° 0.0 m 1x1 82 82
2 Mount (Horizontal) kW
2 (14.1
Home Runs 4 mm2 (Copper)
m)
Home Runs 6 mm2 (Copper) 2 (0.7 m)
Combiners 1 input Combiner 2
Combiners 2 input Combiner 2
4 (96.6
Strings 10 AWG (Copper)
m)
PT. Indonesia Solar Global, ISG- 82 (36.1
Module
HCP144 (440W) kW)

© 2023 Aurora Solar 2/3 October 27, 2023


Annual Production Report produced by Bangun Solar Global

 Detailed Layout

© 2023 Aurora Solar 3/3 October 27, 2023

You might also like