An IEC 61850 client (or master), for example a PACiS computer (MiCOM C264) or
HMI, or
An MMS browser, with which the full data model can be retrieved from the IED, without
any prior knowledge
7.3.1 Capability
The IEC 61850 interface provides the following capabilities:
Reports
Reports only include data objects that have changed and not the complete dataset. SC
The exceptions to this are a General Interrogation request and integrity reports.
Buffered Reports
Eight Buffered Report Control Blocks, (BRCB), are provided in SYSTEM/LLN0 in
Logical Device ‘System’.
Buffered reports are configurable to use any configurable dataset located in the same
Logical device as the BRCB (SYSTEM/LLN0).
Unbuffered Reports
Sixteen Unbuffered Report Control Blocks, (URCB) are provided in SYSTEM/LLN0 in
Logical Device ‘System’.
Unbuffered reports are configurable to use any configurable dataset located in the
same Logical device as the URCB (SYSTEM/LLN0).
P64x/EN SC/B42 SCADA Communications
Uniqueness of control
The Uniqueness of control mechanism is implemented in the P64x to be consistent
with the PACiS mechanism. This requires the relay to subscribe to the OrdRun signal
from all devices in the system and be able to publish such a signal in a GOOSE
message.
Address List
An Address List document (to be titled ADL) is produced for each IED which shows
the mapping between the IEC61850 data model and the internal data model of the
IED. It includes a mapping in the reverse direction, which may be more useful. This
document is separate from the PICS/MICS document.
Originator of Control
Originator of control mechanism is implemented for operate response message and in
the data model on the ST of the related control object, consistent with the PACiS
mechanism.
Metering
MMTR (metering) logical node is implemented in P14x. All metered values in the
MMTR logical node are of type BCR. The actVal attribute of the BCR class is of type
INT128, but this type is not supported by the SISCO MMSLite library. Instead, an
INT64 value will be encoded for transmission.
A SPC data object named MTTRs has been included in the MMTR logical node. This
control will reset the demand measurements. A SPC data object named MTTRs is
also included in the PTTR logical node. This control will reset the thermal
measurements.
Scaled measurements
The Unit definition, as per IEC specifies an SI unit and an optional multiplier for each
measurement. This allows a magnitude of measurement to be specified e.g. mA, A,
kA, MA.
SC The multiplier will always be included in the Unit definition and will be configurable in
SCL, but not settable at runtime. It will apply to the magnitude, rangeC.min &
rangeC.max attributes. rangeC.min & rangeC.max will not be settable at runtime to be
more consistent with Px30 and to reduce configuration problems regarding
deadbands.
Setting changes, such as changes to protection settings, are done using MiCOM S1 Studio.
These changes can also be done using the relay’s front port serial connection or the relay’s
Ethernet link, and is known as “tunneling”.
SCADA Communications P64x/EN SC/B42
7.6.1 Scope
A maximum of 32 virtual inputs are available in the PSL which can be mapped directly to a
published dataset in a GOOSE message (only 1 fixed dataset is supported). All published
GOOSE signals are BOOLEAN values.
Each GOOSE signal contained in a subscribed GOOSE message can be mapped to any of
SC the 32 virtual inputs in the PSL. The virtual inputs allow the mapping to internal logic
functions for protection control, directly to output contacts or LEDs for monitoring.
The MiCOM relay can subscribe to all GOOSE messages but only the following data types
can be decoded and mapped to a virtual input:
BOOLEAN
BSTR2
INT16
INT32
INT8
SCADA Communications P64x/EN SC/B42
UINT16
UINT32
UINT8
SC
P64x/EN SC/B42 SCADA Communications
If both rear communications ports are connected to the same bus, make sure their address
settings are not the same to avoid message conflicts.
Pin Connection
1 No Connection
2 RxD
3 TxD
4 DTR#
5 Ground
6 No Connection
7 RTS#
8 CTS#
9 No Connection
Pin* Connection
4 EIA(RS)-485 - 1 (+ ve)
7 EIA(RS)-485 - 2 (- ve)
Connector pins 4 and 7 are used by both the EIA(RS)-232and EIA(RS)-485 physical
layers, but for different purposes. Therefore, the cables should be removed during
configuration switches.
EIA(RS)-485 is polarity sensitive, with pin 4 positive (+) and pin 7 negative (-).
SC
P64x/EN SC/B42 SCADA Communications
SC
Symbols and Glossary P64x/EN SG/B42
SG
Symbols and Glossary P64x/EN SG/B42
Logic symbols
Symbols Explanation
“Sigma”:
Used to indicate a summation, such as cumulative current interrupted.
“Tau”:
Used to indicate a time constant, often associated with thermal characteristics.
BU Backup:
Typically a back-up protection element.
C/O A changeover contact having normally closed and normally open connections:
Often called a “form C” contact.
CB Circuit breaker.
CB Aux. Circuit breaker auxiliary contacts:
Indication of the breaker open/closed status.
CBF Circuit breaker failure protection.
CLIO Current Loop Input Output:
0-1 mA/0-10 mA/0-20 mA/4-20 mA transducer inputs and outputs
CLI = current loop input - 0-1 mA/0-10 mA/0-20 mA/4-20 mA transducer input
CLO = current loop output - 0-1m A/0-10m A/0-20 mA/4-20 mA transducer output
CT Current transformer.
CTRL. Abbreviation of “Control”:
As used for the Control Inputs function.
SG
CTS Current transformer supervision:
To detect CT input failure.
P64x/EN SG/B42 Symbols and Glossary
Symbols Explanation
Symbols Explanation
Symbols Explanation
SG Rx Abbreviation of “Receive”:
Typically used to indicate a communication receive line/pin.
S1 Used in IEC terminology to identify the secondary CT terminal polarity:
Replace by a dot when using ANSI standards.
S2 Used in IEC terminology to identify the secondary CT terminal polarity:
The non-dot terminal.
Also used to signify negative sequence apparent power, S2 = V2 x I2.
t A time delay.
Symbols and Glossary P64x/EN SG/B42
Symbols Explanation
Logic timers
Logic
Explanation Time Chart
symbols
INPUT
t
t OUTPUT
Delay on pick-up timer, t
0 INPUT
t
OUTPUT
INPUT
OUTPUT
0 t
Delay on drop-off timer, t INPUT
t
OUTPUT
t
INPUT
t1 t2
t1 OUTPUT
Delay on pick-up/drop-off timer
t2 INPUT
t1 t2
OUTPUT
INPUT
t
OUTPUT
Pulse timer
t
INPUT
t
OUTPUT
INPUT
Pulse pick-up falling edge t
t OUTPUT
INPUT
SG Pulse pick-up raising edge t
t OUTPUT
INPUT
Latching Latch
OUTPUT
Symbols and Glossary P64x/EN SG/B42
Logic
Explanation Time Chart
symbols
INPUT
Dwell t
OUTPUT
Dwell timer
Timer
INPUT
t
OUTPUT
SG
P64x/EN SG/B42 Symbols and Glossary
Logic gates
AND GATE
Symbol Truth Table Symbol Truth Table Symbol Truth Table
OR GATE
Symbol Truth Table Symbol Truth Table Symbol Truth Table
R - S FLIP-FLOP
Symbol Truth Table Symbol Truth Table Symbol Truth Table
EXCLUSIVE OR GATE
Symbol Truth Table Symbol Truth Table Symbol Truth Table
SG NOT GATE
Symbol Truth Table
IN OUT
A Y A Y
Inverter (NOT) 0 1
1 0
Installation P64x/EN IN/B42