You are on page 1of 1

Evidence of Performance

Air Infiltration, Static Water Penetration, Structural Performance

Test Report
No. 18-000801-PR06
(PB-C01-02-en-01)

Client ALUMIL S.A. Basis


Industrial Area Testing was conducted on basis
61100 Kilkis of information provided by the
customer
Greece
Product Sliding sash with fixed sidelight Testing in accordance with:
ASTM E 283-04
Designation System: M9660 ASTM E 331-00
Shipping name: M9660 Inward opening ASTM E 330-02
Performance-relevant Material: Aluminium profiles with thermal break
product details Representation
Overall dimensions 1,000 mm x 2,200 mm
(W x H)
Special features The strength, durability and material compatibility of the ad-
hesive system was not part of the test and tested separately.
Results

Test performed Summary of test results

Preload + 1,000 Pa Passed


ASTM E 330

Static air leakage


± 300 Pa Passed
Infiltration / Exfiltration
ASTM E 283

Static water penetration + 300 Pa Passed


ASTM E 331 Instructions for use
Structural performance - The data and results refer solely
to the tested and describes spec-
Test load
100 % of design wind load,
± 2,000 Pa Passed imen. Classification remains valid
as long as the product and the
procedure B above basis remain unchanged.
The results can be extrapolated
Structural performance - under the manufacturer's own li-
ASTM E 330 Proof load ability subject to observance of
150 % of design wind load,
± 3,000 Pa Passed the relevant specifications set out
by the applicable product stand-
procedure B ard. This test/valuation does not
allow any statement to be made
on any further characteristics re-
ift Rosenheim garding performance and quality
of the construction presented; in
08.05.2018 particular the effects of weather-
ing and ageing were not taken in-
to account
Notes on publication
The ift-Guidance Sheet "Adver-
tising using ift test documents"
applies

Thomas Stefan, Dipl.-Ing. (FH) Thomas Krichbaumer


Head of Testing Department Operating Testing Officer Contents
Building Component Testing Building Component Testing The report contains a total of
29 pages.
11-03 / 505