Dropped Object Survey Report

RIG NAME : ST-21 CLIENT : Sino Tharwa - Date of Inspection : 8 March 2018 INSPECTED BY : Ashraf Nagib

Photograph Photo Ref. Description / Location Fastening Method Condition Control


Description: FLOOD LIGHT Primary Securing: BOLTED TO STRUCTURE ( x ) Pass ( ) Fail
Comments:Satisfactory at the time of inspection

1 30 Days
Location: ENGINE ROOM Secoundary Retention: SPRING WASHER AND
LOCK NUT

Description: FLUORESCENT LIGHT Primary Securing: BOLTED TO STRUCTURE ( x ) Pass ( ) Fail


Comments: Satisfactory at the time of inspection

2 30 Days
Location: ENGINE ROOM Secoundary Retention: SPRING WASHER AND LOCK
NUT , SAFETY WIRE SLING

Description: FLUORESCENT LIGHT Primary Securing: BOLTED TO STRUCTURE ( x ) Pass ( ) Fail


Comments: Satisfactory at the time of inspection

3 30 Days
Location: ENGINE ROOM Secoundary Retention: SPRING WASHER AND LOCK
NUT

Description: FLUORESCENT LIGHT Primary Securing: BOLTED TO STRUCTURE ( x ) Pass ( ) Fail


Comments: Satisfactory at the time of inspection

4 30 Days
Location: ENGINE ROOM Secoundary Retention: SPRING WASHER AND LOCK
NUT

Description: FLOOD LIGHT Primary Securing: BOLTED TO STRUCTURE ( x ) Pass ( ) Fail


Comments: Satisfactory at the time of inspection

5 30 Days
Location: ENGINE ROOM Secoundary Retention: SPRING WASHER AND
LOCK NUT

Description: STAIRS Primary Securing: HINGED TO SUPPORT ( x ) Pass ( ) Fail


Comments: Satisfactory at the time of inspection

6 30 Days
Location: SUBSTRUCTURE Secoundary Retention: SUPPORT WELDED TO
STRUCTURE

Page 1 of 6
NOV TUBOSCOPE
Dropped Object Survey Report

RIG NAME : ST-21 CLIENT : Sino Tharwa - Date of Inspection : 8 March 2018 INSPECTED BY : Ashraf Nagib

Photograph Photo Ref. Description / Location Fastening Method Condition Control


Description: HANDRAIL Primary Securing: BOLTED TO STRUCTURE ( x ) Pass ( ) Fail
Comments: Satisfactory at the time of inspection

7 30 Days
Location: SUBSTRUCTURE Secoundary Retention: SAFETY PIN , SAFETY COTTER
PIN .

Description: FLOOD LIGHT Primary Securing: BOLTED TO STRUCTURE ( x ) Pass ( ) Fail


Comments: Satisfactory at the time of inspection

8 30 Days
Location: SUBSTRUCTURE Secoundary Retention: SPRING WASHER AND LOCK
NUT , SAFETY WIRE SLING

Description: FLOOD LIGHT Primary Securing: BOLTED TO STRUCTURE ( x ) Pass ( ) Fail


Comments: Satisfactory at the time of inspection

9 30 Days
Location: SUBSTRUCTURE Secoundary Retention: SPRING WASHER AND LOCK
NUT , SAFETY WIRE SLING

Description: FIRE EXTINGUISHER Primary Securing: INSIDE BRACKET, BRACKET ( x ) Pass ( ) Fail
BOLTED TO STRUCTURE Comments: Satisfactory at the time of inspection

10 30 Days
Location: SUBSTRUCTURE Secoundary Retention: SPRING WASHER AND LOCK
NUT

Description: HANDRAIL Primary Securing: BOLTED TO STRUCTURE ( x ) Pass ( ) Fail


Comments: Satisfactory at the time of inspection

11 30 Days
Location: SUBSTRUCTURE Secoundary Retention: SAFETY PIN , SAFETY COTTER
PIN .

Description: FLOOD LIGHT Primary Securing: BOLTED TO STRUCTURE ( x ) Pass ( ) Fail


Comments: Satisfactory at the time of inspection

12 30 Days
Location: SUBSTRUCTURE Secoundary Retention: SPRING WASHER AND LOCK
NUT , SAFETY WIRE SLING

Page 2 of 6
NOV TUBOSCOPE
Dropped Object Survey Report

RIG NAME : ST-21 CLIENT : Sino Tharwa - Date of Inspection : 8 March 2018 INSPECTED BY : Ashraf Nagib

Photograph Photo Ref. Description / Location Fastening Method Condition Control


Description: STAIRS Primary Securing: HINGED TO SUPPORT ( x ) Pass ( ) Fail
Comments: Satisfactory at the time of inspection

13 30 Days
Location: SUBSTRUCTURE Secoundary Retention: SUPPORT WELDED TO
STRUCTURE

Description: FLOOD LIGHT Primary Securing: BOLTED TO STRUCTURE ( x ) Pass ( ) Fail


Comments: Satisfactory at the time of inspection

14 30 Days
Location: SUBSTRUCTURE Secoundary Retention: SPRING WASHER AND LOCK
NUT

Description: FLOOD LIGHT Primary Securing: BOLTED TO STRUCTURE ( x ) Pass ( ) Fail


Comments: Satisfactory at the time of inspection

15 30 Days
Location: SUBSTRUCTURE Secoundary Retention: SPRING WASHER AND LOCK
NUT , SAFETY WIRE SLING

Description: FLOOD LIGHT Primary Securing: BOLTED TO STRUCTURE ( x ) Pass ( ) Fail


Comments: Satisfactory at the time of inspection

16 30 Days
Location: SUBSTRUCTURE Secoundary Retention: SPRING WASHER AND LOCK
NUT , SAFETY WIRE SLING

Description: FLOOD LIGHT WITH Primary Securing: BOLTED TO STRUCTURE ( x ) Pass ( ) Fail
STAND Comments: Satisfactory at the time of inspection

17 30 Days
Location: RIG FLOOR Secoundary Retention: SPRING WASHER AND LOCK
NUT , SAFETY WIRE SLING

Description: FLOOD LIGHT WITH Primary Securing: BOLTED TO STRUCTURE ( x ) Pass ( ) Fail
STAND Comments: Satisfactory at the time of inspection

18 30 Days
Location: RIG FLOOR Secoundary Retention: SPRING WASHER AND LOCK
NUT , SAFETY WIRE SLING

Page 3 of 6
NOV TUBOSCOPE
Dropped Object Survey Report

RIG NAME : ST-21 CLIENT : Sino Tharwa - Date of Inspection : 8 March 2018 INSPECTED BY : Ashraf Nagib

Photograph Photo Ref. Description / Location Fastening Method Condition Control


Description: FLUORESCENT LIGHT Primary Securing: BOLTED TO STRUCTURE ( x ) Pass ( ) Fail
Comments: Satisfactory at the time of inspection

19 30 Days
Location: RIG FLOOR Secoundary Retention: SPRING WASHER AND LOCK
NUT , SAFETY WIRE SLING

Description: LADDER Primary Securing: BOLTED TO STRUCTURE ( x ) Pass ( ) Fail


Comments: Satisfactory at the time of inspection

20 30 Days
Location: RIG FLOOR Secoundary Retention: SAFETY PIN , SAFETY COTTER
PIN .

Description: FLUORESCENT LIGHT Primary Securing: BOLTED TO STRUCTURE ( x ) Pass ( ) Fail


Comments: Satisfactory at the time of inspection

21 30 Days
Location: FROM RIG FLOOR TO Secoundary Retention: SPRING WASHER AND LOCK
MONKEY BOARD NUT , SAFETY WIRE SLING

Description: VENT LINE Primary Securing: BOLTED TO STRUCTURE ( x ) Pass ( ) Fail


Comments: Satisfactory at the time of inspection

22 30 Days
Location: FROM RIG FLOOR TO Secoundary Retention: SPRING WASHER AND LOCK
MONKEY BOARD NUT

Description: FLUORESCENT LIGHT Primary Securing: BOLTED TO STRUCTURE ( x ) Pass ( ) Fail


Comments: Satisfactory at the time of inspection

23 30 Days
Location: FROM RIG FLOOR TO Secoundary Retention: SPRING WASHER AND LOCK
MONKEY BOARD NUT , SAFETY WIRE SLING

Description: FLUORESCENT LIGHT Primary Securing: BOLTED TO STRUCTURE ( x ) Pass ( ) Fail


Comments: Satisfactory at the time of inspection

24 30 Days
Location: FROM RIG FLOOR TO Secoundary Retention: SPRING WASHER AND LOCK
MONKEY BOARD NUT , SAFETY WIRE SLING

Page 4 of 6
NOV TUBOSCOPE
Dropped Object Survey Report

RIG NAME : ST-21 CLIENT : Sino Tharwa - Date of Inspection : 8 March 2018 INSPECTED BY : Ashraf Nagib

Photograph Photo Ref. Description / Location Fastening Method Condition Control


Description: FLUORESCENT LIGHT Primary Securing: BOLTED TO STRUCTURE ( x ) Pass ( ) Fail
Comments: Satisfactory at the time of inspection

25 30 Days
Location: FROM MONKEY BOARD Secoundary Retention: SPRING WASHER AND LOCK
TO CROWN BLOCK NUT , SAFETY WIRE SLING

Description: FLUORESCENT LIGHT Primary Securing: BOLTED TO STRUCTURE ( x ) Pass ( ) Fail


Comments: Satisfactory at the time of inspection

26 30 Days
Location: FROM MONKEY BOARD Secoundary Retention: SPRING WASHER AND LOCK
TO CROWN BLOCK NUT , SAFETY WIRE SLING

Description: FLUORESCENT LIGHT Primary Securing: BOLTED TO STRUCTURE ( x ) Pass ( ) Fail


Comments: Satisfactory at the time of inspection

27 30 Days
Location: FROM MONKEY BOARD Secoundary Retention: SPRING WASHER AND LOCK
TO CROWN BLOCK NUT , SAFETY WIRE SLING

Description: WARNING LIGHT Primary Securing: BOLTED TO STRUCTURE ( x ) Pass ( ) Fail


Comments: Satisfactory at the time of inspection

28 30 Days
Location: CROWN BLOCK Secoundary Retention: SPRING WASHER AND LOCK
NUT , SAFETY WIRE SLING

Description: CROWN BLOCK Primary Securing: BOLTED TO STRUCTURE ( x ) Pass ( ) Fail


SHEAVES Comments: Satisfactory at the time of inspection

29 30 Days
Location: CROWN BLOCK Secoundary Retention: SPRING WASHER AND LOCK
NUT

Description: HANDRAIL Primary Securing: INSIDE BRACKET ( x ) Pass ( ) Fail


Comments: Satisfactory at the time of inspection

30 30 Days
Location: CROWN BLOCK Secoundary Retention: BRACKET WELDED TO
STRUCTURE

Page 5 of 6
NOV TUBOSCOPE
Dropped Object Survey Report

RIG NAME : ST-21 CLIENT : Sino Tharwa - Date of Inspection : 8 March 2018 INSPECTED BY : Ashraf Nagib

Photograph Photo Ref. Description / Location Fastening Method Condition Control


Description: FAST LINE SHEAVES Primary Securing: BOLTED TO STRUCTURE ( x ) Pass ( ) Fail
Comments: Satisfactory at the time of inspection

31 30 Days
Location: CROWN BLOCK Secoundary Retention: SPRING WASHER AND LOCK
NUT

FAIL LIST

Description: FLUORESCENT LIGHT Primary Securing: HANGED TO STRUCTURE BY ( ) Pass ( X ) Fail


ROPES Comments: FAIL at the time of inspection

34 30 Days
Location: ENGINE ROOM Secoundary Retention: BRACKET WELDED TO * NOTHING SHOULD BE HANGED BY ROPES
STRUCTURE *IT SHOULD BE BOLTED TO STRUCTURE & SECURED
WITH WIRE SLINGS