CENTRIFUGAL PUMP DATA SHEET

APPLICABLE TO: PROPOSAL APPLICABLE NTL/INTNTL STANDARD: API-610


FOR Cnergyico Pakistan Limited UNIT 0300
SITE Oil Refinery Complex-II Mouzakund Plant SERVICE Cooling Water
NO. REQ 4 PUMP SIZE VTA TYPE Centrifugal No. STAGES VTA
MANUFACTURER KSB Pumps MODEL 206/195/196/15°/A06
LIQUID CHARACTERISTICS
Units Maximum Minimum Note SERVICE : CONTINUOUS
LIQUID TYPE OR NAME : Cooling Water Max & min values refer • IF INTERMITTENT NO. OF STARTS :
VAPOR PRESSURE : psia 0.816 only to the property PUMPS OPERATE IN: PARALLEL
RELATIVE DENSITY : - 0.994 listed CORROSION DUE TO : (6.12.1.9)
SPECIFIC HEAT : Btu/(lbm-°F) EROSION DUE TO : (6.12.1.9)
VISCOSITY : cP 0.290 H2S CONCENTRATION (ppm) : (6.12.1.12) <10

OPERATING CONDITIONS (6.1.2) CHLORIDE CONCENTRATION (ppm) :


Units Maximum Rated Normal Minimum PARTICULATE SIZE (DIA IN MICRONS)

NPSHa Datum: C.L. Impeller PARTICULATE CONCENTRATION (PPM)

PUMPING TEMPERATURE : °F 95
FLOW : gpm 3577.2 3252 880
DISCHARGE PRESSURE : (6.3.2) psia 63.8
SUCTION PRESSURE : psia 2.0
DIFFERENTIAL PRESSURE : psi 62
DIFFERENTIAL HEAD : ft 144
NPSHA : ft 34.7
HYDRAULIC POWER : HP 117

SITE AND UTILITY DATA


LOCATION: COOLING WATER :
OUTDOOR UNHEATED INLET RETURN DESIGN
MOUNTED AT : GRADE m TROPICALISATION REQD TEMP °F 95 MAX 100 113
PRESS. psig 62 MIN 77 90
SOURCE Cooling Water
SITE DATA : COOLING WATER CHLORIDE CONCENTRATION: ppm
ELEVATION (MSL) : 30 ft BAROMETER : 28.9 in Hg INSTRUMENT AIR : MAX 100 psig MIN 80 psig
RANGE OF AMBIENT TEMPS:MIN / MAX 53.6 / 111.2 °F STEAM
RELATIVE HUMIDITY: MIN / MAX 48 / 73 % DRIVERS HEATING
UNUSUAL CONDITIONS: DUST TEMP °F Max - -

UTILITY CONDITIONS : PRESS. psig Max - -

ELECTRICITY : DRIVERS HEATING CONTROL SHUTDOWN Min - -

VOLTAGE 400 - - -
PHASE 3 - - -
HERTZ 50 - - -

PERFORMANCE (VTS) DRIVER (VTS)


PROPOSAL CURVE NO. 1311.45/11-EN RPM 2900 Driver Type MOTOR
As Tested Curve No. - GEAR
IMPELLER DIA.: RATED - MAX. MIN. - in. VARIABLE SPEED REQUIRED YES
RATED POWER 135 HP EFFICIENCY 82.4 (%) SOURCE OF VARIABLE SPEED Motor
Abbreviations; VTA = Vendor to Advise, VTS = Vendor to Specify, VTC = Vendor to Confirm
DATA SHEET No. PP-PE-DS-0108-003 Rev: 1 SHEET 1 of 1