HEAT EXCHANGER SPECIFICATION SHEET

1 Job No.:
2 Customer PV Engineering Reference No.:
3 Address Waterloo, ON Proposal No.:
4
Plant Location Date: August 24, 2010 Rev. 2
5
6 Service of Unit: Hot oil heater Item No: E-101
7 Size 17 / 96 in Type BEM Connected in 1 parallel 1 series
8 Surf/unit (eff.) 213.7 ft2 Hor Shells/unit Surf/shell (eff.) 213.7 ft2
1
PERFORMANCE OF ONE UNIT
9
Fluid allocation Shell Side Tube Side
10
Fluid name
11
Fluid quantity, Total lb/h 10443 116667
12
Vapor (In/Out) lb/h 10443 0 0 0
13
Liquid lb/h 0 10443 116667 116667
14
Noncondensable lb/h
15
16
Temperature (In/Out) F 572.59 571.2 380 479.19
17
Dew / Bubble point F 572.59 572.59 578.38 578.38
18
Density (Vap / Liq) lb/ft3 2.625 / / 44.755 / 53.323 / 50.581
19
Viscosity cp 0.0215 / / 0.0953 / 0.3576 / 0.2262
20
Molecular wt, Vap 18.01
21
Molecular wt, NC
22
Specific heat 1.4586 / / 1.1674 / 0.5199 / 0.5641
23
BTU/(lb*F)
Thermal conductivity 0.039 / / 0.301 / 0.079 / 0.071
24
BTU/(ft*h*F)
Latent heat
25
BTU/lb
Pressure psi 1250 1249.96 30 26.86
26
Velocity ft/s 2.93 6.5
27
Pressure drop, allow./calc. psi 13.95 0.05 10 3.14
28
Fouling resist. (min) 0.0005 0.001 0.0012 Ao based
29
ft2*h*F/BTU
Heat exchanged 6273921 BTU/h MTD corrected 140.31 F
30
Transfer rate, Service 209.93 Dirty 209.91 Clean 326.28 BTU/(h*ft2*F)
31 CONSTRUCTION OF ONE SHELL Sketch
32 Shell Side Tube Side T2 S3

33
Design/Vac/Test pressure psi 1400 / FV / 150 / /
34
Design temperature F 650 650
35
Number passes per shell 1 4
36
Corrosion allowance 0.0625 0.0625
37
in
Connections In in 6 / 900 ANSI 1 4 / 300 ANSI
38 Size/rating
T1 S2 S1

Out 1 3 / 900 ANSI 1 4 / 300 ANSI


39 Nominal
Intermediate / 900 ANSI / 300 ANSI
40
Tube No. 104 OD 1 Tks- Avg 0.083 in Length 96 in Pitch 1.25 in
41
Tube type Plain Material Carbon Steel Tube pattern 30
42
Shell Carbon Steel ID 17.25 OD 19 in Shell cover -
43
Channel or bonnet Carbon Steel Channel cover -
44 Tubesheet-stationary Carbon Steel Tubesheet-floating -
45
Floating head cover - Impingement protection Rods
46
Baffle-crossing Carbon Steel Type Single segmental Cut(%d) 24.7 V Spacing: c/c 15.5 in
47
Baffle-long - Seal type Inlet 15.9375 in
48
Supports-tube U-bend Type
49 Bypass seal Tube-tubesheet joint Exp. 2 grv
50
Expansion joint Carbon Steel Type Flange and flued (TEMA)
51
RhoV2-Inlet nozzle 98 Bundle entrance 14 Bundle exit 3 lb/(ft*s2)
52 8
Gaskets - Shell side Spiral-Wound Metal Fib Tube Side Spiral-Wound Metal Fib
53
Floating head -
54
Code requirements ASME Code Sec VIII Div 1 TEMA class B - chemical service
55
Weight/Shell 3709.1 Filled with water 4554.4 Bundle 1198.5 lb
56
Remarks
57
58
59

Page 1 of 5

HC Heat Transfer Solutions Inc. www.hcheattransfer.com 1-


877-542-1214
HEAT EXCHANGER SPECIFICATION SHEET
1 Job No.:
2 Customer PV Engineering Reference No.:
3 Address Waterloo, ON Proposal No.:
4 Plant Location Date: August 24, 2010 Rev. 2
5 Service of Unit: Hot oil heater Item No: E-101
6 Size 17 / 96 in Type BEM Hor Connected in 1 parallel 1 series
7 Surf/Unit(eff) 213.7 ft2 Shells/Unit 1 Surf/Shell(eff) 213.7 ft2
8
9
10
Shell Side Nozzle Table
11
12 Nozzle Service Mark No. Size (inch) SCH Class (psig) FACE TYPE COMMENT
13
14 Steam Inlet S1 1 6 XXH 900 ANSI RF WN located on the side
Condensate Outlet S2 1 3 XXH 900 ANSI RF WN located on the bottom
15
Vent S3 1 2 XXH 900 ANSI RF WN located on the top
16
17
18
19
20
21
22 Tube Side Nozzle Table
23
Nozzle Service Mark No. Size (inch) SCH Class (psig) FACE TYPE COMMENT
24
25 Inlet T1 1 4 40 300 ANSI RF WN located on the bottom
26 Outlet T2 1 4 40 300 ANSI RF WN located on the top
27 Drain T3 1 1 80 300 ANSI RF WN located at rear end
Vent T4 1 1 80 300 ANSI RF WN located at rear end
28
29
30
31
32
33 Mean Metal Wall Temperature
34
Temperature Conditions Shell Tube Tubesheet Units
35
36 Normal Operating Mean Wall Temperature 573 535.89 463 F
37 Maximum Operating Mean Wall Temperature F
38 Startup Mean Wall Temperature 480 394 240 F
39 Upset Mean Wall Temperature
Steam Out Mean Wall Temperature
40
Other Operating Mean Wall Temperature
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56

HC Heat Transfer Solutions Inc. Page 2 of 5


www.hcheattransfer.com 1-877-542-1214
HEAT EXCHANGER SPECIFICATION SHEET
1 Job No.:
2 Customer PV Engineering Reference No.:
3 Address Waterloo, ON Proposal No.:
4 Plant Location Date: August 24, 2010 Rev. 2
5 Service of Unit: Hot oil heater Item No: E-101
6 Size 17 / 96 in Type BE Hor Connected in 1 parallel 1 series
M
7 Surf/Unit(eff) 213.7 ft2 Shells/Unit 1 Surf/Shell(eff) 213.7 ft
2

NOTES

1- Two (2) rows of impingement rods on a 30 deg layout are to be used for impingement protection 2-
Baffles to have a 1" V notch at the bottom
3- The shell inlet nozzle is to be located on the side
4- Dummy tubes (6) are to be installed in the horizontal pass partition lane.

www.hcheattransfer.com 1-877-542-1214
HC Heat Transfer Solutions Inc.
Page 3 of 5

www.hcheattransfer.com 1-877-542-1214
HEAT EXCHANGER SPECIFICATION SHEET

1 Job No.:
2 Customer PV Engineering Reference No.:
3 Address Waterloo, ON Proposal No.:
4 Plant Location Date: August 24, 2010 Rev. 2
5 Service of Unit: Hot oil heater Item No: E-101
6 Size 17 / 96 in Type BEM Hor Connected in 1 parallel 1 series
7 Surf/Unit(eff) 213.7 ft2 Shells/Unit 1 Surf/Shell(eff) 213.7 ft2

Tubesheet Layout

Shell inside diameter in 17.25

Front head inside diameter in 17.25


Outertubelimit in 16.8125
Tube number 104
Tube O.D. in 1.
Tube pitch in 1.25
Tube pattern 30
Tube passes 4
Tierod number -1
Tierod diameter in 0.376
Sealing strips (pairs) 0
Baffle type Single segmental
Impingement protection Rods
Tube length in 96.
Shell Side Inlet Nozzle Inside Diameter in 5.761
Shell Side Outlet Nozzle Inside Diameter in 3.068
Shell Side Outlet Nozzle Inside Diameter in 2.067

Customer: H&C Heat Transfer Solutions


Ad dres s: Sarnia, ON Aspen Shell & Tube
Service o f Unit:
Item No.: E-101

Tube Layout
Design Codes
ASME Code Sec VIII Div 1
1.00 24 28 TEMA B - chemical service
Drawing Number
CustomerSpecifications

1.25 24 28 Revision Date Dwg. App.


24/08/2010

HC Heat Transfer Solutions Inc.


www.hcheattransfer.com 1-877-542-1214
Page 4 of 5
HEAT EXCHANGER SPECIFICATION SHEET

1 Job No.:
2 Customer PV Engineering Reference No.:
3 Address Waterloo, ON Proposal No.:
4 Plant Location Date: August 24, 2010 Rev. 2
5 Service of Unit: Hot oil heater Item No: E-101
6 Size 17 / 96 in Type BEM Hor Connected in 1 parallel 1 series
7 Surf/Unit(eff) 213.7 ft2 Shells/Unit 1 Surf/Shell(eff) 213.7 ft2

Setting Plan

V iews on arrow A
A
3.25 131.125 Overall
T2
11.125 7.125 6.5 81.0

T2 S3

T1
3.25

S 1 S3

T1 S2 S1
S2 16
7.125 19.1875 57.625

Pulling Length 79
2.0 2.0

4.0 4.0
2 Bolts 2 Bolts
Fixed Sliding

Nozzle Data Design Data Units Shell Channel C ustome r : H&C H eat Tr ansfer Solutions
Ref OD W all Standard Notes Design Pressure psi 1399.99 150. Ad dress : Sarnia, ON Aspen Shell & Tube Exchang er
S1 6. 625" 0. 432" 900 ANSI W eld neck Design T emperat ure F 650. 650. Se rvic e of Unit:
S2 3.5" 0. 216" 900 ANSI W eld neck F ull Vacuum Item N o .:E- 101

S3 2. 375" 0. 154" 900 ANSI W eld neck Corrosion Allowance in 0. 0625 0.0625 D ate: Au g 2010 R ev N o.: 1 J ob N o .: Setting Plan
T1 4.5" 0. 237" 300 ANSI W eld neck T est Pressure psi
T2 4.5" 0. 237" 300 ANSI W eld neck Number of Passes 1 4 Design Codes BEM 17 - 96
Radiography ASME Section VIII Div. 1
PWHT T EMA B
Internal Volume ft³ 12. 5125 4.4291 Drawing Number
Customer Specifications
W eight Summary
Empty F looded Bundle Revision Date Dwg. Chk. App.
3709 lb 4554 lb 1198 lb 24/ 08/ 2010

HC Heat Transfer Solutions Inc.


www.hcheattransfer.com 1-877-542-1214
Page 5 of 5