1. Main technical parameters
1. Operating voltage: AC220V / 50H Z;
2. Motor power: 120W;
3. Environmental humidity: -35 degrees- - + 85 degrees
4. Working humidity: less than 95% without condensation;
5. Lift speed: 3 seconds / 6 seconds (optional)
6. Center height of the gate bar: 890mm
7. Input signal: switch signal;
8. Remote control distance: 30 M
Corresponding relation between gate bar length and speed:
The gate has been matched with the movement according to the rod length, please use the
gate according to the rod length. It is recommended that the movement does not use more than
4 meters of straight rod in 3 seconds, the rod is too long, the rod rise and fall shake seriously may
cause mechanical damage.

Table of parameters corresponding to rod length and speed


Bar type club length Take off and club length Take off and
(m) landing time (m) landing time
(S) (S)
Straight rod 4.0 至 6m 6s ≤4.0m 3s
Broken arm pole 4.0 至 5m 6s ≤4.0m 3s
rack stake 3.5 至 4.5m 6s ≤3.5m 3s
The direction of the gate:
The direction has been adjusted when leaving the factory. If the installation direction of
the machine needs to be changed, adjust the direction of the spring hanging arm, the installation
direction of the limit plate, the fixed direction of the spring, and the motor on and off wiring of
the controller.

1
图1 图2
Operation instructions of the spring hanging hole.
When the gate leaves the factory, the gate spring tension has been adjusted to
balance. If the field installation needs to change the rod length, refer to the figure
below to change the spring or change the hanging hole position, and observe the
stability of the gate lever. If the drop lever shake is obvious, the spring tension
is not enough; If the lever bar shake is more obvious, the spring tension is too
large, so adjust the hanging hole position or adjust the tightness of the spring.

4、Remote control is paired and deleted


Remote transmission coding method is welding code, remote receiving method is
learning. Before the remote control is used, you need to learn in pairs. You can
only learn six groups of different remote control coding, and the same coding is
unlimited.
5.1、Remote control pairing
Release the "Learn / Remove" button, and the "Learn / Remove" indicator is on;
and press any button of the remote control to be learned. If the "Learn / Remove"
light flashes twice, the learning signal is successful. If the Learn / Remove light
does not flash, the study is unsuccessful and needs to be studied again.
5.2、Remote control delete coding (all coding deleted)
Press the Learn / Remove button until the Learn / Remove light flashes, and all
the codes will be deleted.

6.Common faults and troubleshooting


6.1、The equipment does not switch off normally:
1. Check whether the machine is energized and confirm whether the voltage
is within 5% of 220V ±;
2. If the power supply is normal, confirm whether the gate rod has been
installed, whether the length of the installed gate rod is matched. If the length
of the gate rod is long when the factory and the shorter gate rod is used on

2
site, which may cause the machine can not shut down normally or the landing rod
shakes seriously, it is necessary to adjust the spring hole position or replace
the spring;
3. Check that the switch circuit is short circuit. After removing the
external line of the switch controller (license plate recognition brake line,
manual button brake line, etc.), check whether the open, close and stop of the
remote control transmitter are normal.
4. Check whether the vehicle detector is dead: if the vehicle detector signal
indicator light is often on, it means that the vehicle detector is dead, and the
power is turned off to reset. If the vehicle detector dies frequently, check whether
the ground sensor coil laid on the ground is damaged, and reduce the sensor
sensitivity of the vehicle detector if there is no damage or replace the vehicle
detector.
5. Check whether the motor is stuck (if the motor swing arm and mechanical limit
extrusion are serious, the motor is stuck). If it is, the motor swing arm needs to
be shaken to normal through the motor handle.
6. Check whether the limit indicator on the limit plate is fully bright (the on-limit
and off-limit indicators are on at the same time, and the two indicators are only
one in normal state), if it may be that the limit plate is faulty, and the limit
plate needs to be replaced.
6.2. The equipment cannot be opened normally:
1. Check that the switch circuit is short circuit. After removing the external line
of the switch controller (license plate recognition brake line, manual button brake
line, etc.), the opening, close and stop of the remote control transmitter is normal.
2. Check whether the limit indicator on the limit plate is fully bright (the on-limit
and off-limit indicators are on at the same time, and the two indicators are only
one in normal state), if it may be that the limit plate is faulty, and the limit
plate needs to be replaced.