You are on page 1of 1

GARAGE HEADER GARAGE HEADER

ATTACH TO
TOP PLATE W/
8D NAILS, 3" O.C. NAIL INTO HEADER WITH 8D
FIELD NAIL MSTA24 NAILS ON A 3" O.C. GRID
8D NAILS, 12" STRAPS TO POST AND PATTERN. INSTALL SHEATHING
O.C. IN FIELD. HEADER WITH (18) 10D ON OUTSIDE OF WALL ONLY.
COMMON NAILS
7/16" OSB PANEL. NAIL WITH
FASTEN TOP PLATE

10'-0" MAX. HGT.


8D NAILS, 6" 8D NAILS INTO ALL STUDS,
O.C. ON EDGES. TO HEADER WITH 2
3" O.C. NAIL INTO HEADER
ROWS OF 16D SINKER
WITH 8D NAILS ON A 3" O.C.
NAILS AT 3" O.C., TYP.
VARIES GRID PATTERN. INSTALL
SHEATHING ON OUTSIDE OF
IF A PANEL SPLICE WALL ONLY.
IS NEEDED, PROVIDE
48" WIDE 716 " 2X BLOCKING INSTAL SIMPSON STHD10
O.S.B. PANEL. HOLDOWN ANCHORS PRIOR
TWO 2X STUDS
TO CONCRETE BEING POURED.
EACH END OF
NOTE ' ' BRACING ATTACH TO STUDS WITH
PANEL
PANEL TO BE A (24) - 16D NAILS.
MINIMUM OF 4" WIDE HILTI HIT
OR AS SHOWN ON ANCHORS
PLAN.
8D NAILS, 3" O.C.

ATTACH TO CONCRETE DESIGN


BOTTOM PLATE W/ BY OTHERS
TREATED PLATE
8D NAILS, 3" O.C.
CONCRETE DESIGN BRACED WALL DETAIL BRACED WALL DETAIL
BY OTHERS View from inside house View from outside house

1 BRACING PANEL DETAIL


2 TYPICAL CORNER BRACE AT GARAGE
SIMPSON LUC210Z
OR EQUAL

NOTE: INSTALL SHEATHING ON INSIDE AND


OUTSIDE OF WALL IF 2 STORY ABOVE PANEL.
THESE ANCHORS CAN
8 EXTERIOR RIM BOARD
N.T.S. 9 TYP. HANGER DETAIL
N.T.S.
TWO 2X STUDS 8D NAILS, 3" O.C.
BE INSTALLED ON
EITHER SIDE OF
"C" BRACING PANEL.
NAIL ACCORDING TO
EACH END OF SIMPSON HTT5 "C" DETAIL.
PANEL.
PANEL 7/16" OSB PANEL. NAIL
WITH 8D NAILS INTO ALL
IF A PANEL SPLICE STUDS, 3" O.C. INSTALL
IS NEEDED, PROVIDE SHEATHING ON OUTSIDE 2X6 STUDS, TYP.
2X BLOCKING OF WALL ONLY. SIMPSON HTT5
VARIES
INSTALL SIMPSON STHD10 HOLD-DOWN ANCHOR
HILTI HIT
ANCHORS HOLDOWN ANCHORS PRIOR
TO CONCRETE BEING
POURED. ATTACH TO
STUDS WITH 28-16D "A" BRACING PANEL
ALTERNATE LOCATION
NAILS.
FOR THE SECOND
8D NAILS, 3" O.C. SIMPSON HTT5
TREATED PLATE
HOLD-DOWN ANCHOR
CONCRETE DESIGN
CONCRETE DESIGN BY OTHERS
BY OTHERS
BRACED WALL DETAIL
10 TYP. CANTILEVER DETAL
N.T.S. 11 TYP. CANTILEVER DETAL
N.T.S.
BRACED WALL DETAIL
VIEW FROM INSIDE HOUSE VIEW FROM OUTSIDE HOUSE

NOTE: THIS PANEL TO BE USED


SECTION AT SLAB ALTERNATE CORNER BRACING
3 TYPICAL ALTERNATE BRACE PANEL
AT 1ST FLOOR WALL BRACES
LESS THAN 48" IN WIDTH.
4 5 NOTE: USE THIS DETAIL IF TWO ANCHORS CANNOT FIT ON "C" PANEL.

WALL BRACING NOTES ALTERNATE TIE DOWN ANCHORS


1. ALL WALL BRACING TO COMPLY WITH 2015 IRC OR NEWER (USE THESE ANCHORS AFTER THE SLAB IS CURED)
BUILDING CODE CURRENTLY ADOPTED BY CITY OFFICIAL. 1. LOCATE HTT5 SIMPSON TIES AT CORNERS OF THE "C" AND "D"
2. INSTALL BRACING PANELS AS NOTED ON ATTACHED DWG S-4 WALL BRACING PANELS AS NOTED ON WALL BRACING PLANS.
ACCORDING TO DETAILS SHOWN ON THIS PAGE. 2. DRILL INTO SLAB WITH 7/8" DIA. DRILL BIT. HOLES SHOULD BE
3. OSB WALL SHEATHING TO BE INSTALLED WITH GRAIN DRILLED 8" DEEP MIN.
VERTICAL. 3. HOLES SHOULD BE CLEANED WITH COMPRESSED AIR AND
4. AT HORIZONTAL JOINTS, INSTALL 2X4 BLOCKING AT JOINTS BRUSH IN EACH HOLE. ALL CONCRETE DUST MUST BE
AND NAIL. REMOVED FROM HOLES
5. "RED" THERMOPLY, STRUCTURAL GRADE CAN BE SUBSTITUTED 4. IN EACH HOLE, INJECT SIMPSON ACRYLIC-TIE ADHESIVE PER
FOR OSB BRACING IN ALL AREAS EXCEPT AT ALTERNATE MANUFACTURER'S REQ'TS.
BRACE PANELS "C" AND "D". USE 7/16" OSB ON ALL BRACING PANELS. 5. INSTALL 5/8" X 8" THREADED ROD INTO EACH HOLE (SIMPSON
12 TYP. JST. BLOCKING DETAL
N.T.S. 13 TYP. DOUBLE JST. NAILING DETAL
N.T.S. 6. NAIL "RED" THERMOPLY WITH 1-1/4" GALVANIZED ROOFING
NAILS OR 16 GUAGE 7/16" MIN. CROWN STAPLES SPACED 3" O.C.
RFB#5X12). DO NOT DISTURB THREADED ROD FOR AT LEAST
TWO HOURS TO ALLOW GLUE TO CURE.
ON ALL PANEL EDGES AND 6" O.C. IN THE FIELD. 6. AFTER WAITING FOR GLUE TO CURE, INSTALL SIMPSON HTT5
TIES AND NAIL TO STUDS WITH (26) - 16d NAILS.

Prj. #22115 ISSUE RECORD STAMP: LEGEND: CONTACTS: Date:


DATE: ISSUED FOR: COMMENTS:
Ex. = Existing OWNER/AGENT: APPLICANT: ENGINEER: 06-12-2023
OTC = Original Town Commercial
T.O.P. = Top of Parapet Scale:
BFR = Barrier Free Ramp CONSTRUCTION PLANS FOR None
FH = Fire Hydrant 921 Hollywood avenue. texas
R.O.W. = Right of Way Drawn By:
SSMH = Sanitary Sewer Manhole H. S.
FDC = Fire Department Connection
Page:

Drawing File:
Conc. = Concrete
Sq. Ft. = Square Feet
Framing Details S-2