NOTES

1. Dimensions are in millimetres and should be read


from the drawing and not scaled. Any discrepancies
noted should be reported to the project architect
03 before works commence.
2.All structural works to structural engineer's details
38,000
A B C D E F G I J K L M N O

3. 'pv' denotes permanent ventilation and shall be


provided at all positions shown on the drawing.
2,700 2,700 2,700 2,700 2,700 2,700 3,300 2,700 2,700 2,700 2,700 2,700 2,700 2,050
H
All windows and doors to have PV except toilet doors.
4. All drain pipes passing under buildings to be
encased in 150mm concrete surround.
9 9
5. All walls to have hoop iron reinforcement at
alternate courses.
6. 'IC' denotes inspection chamber.
3,000

3,000
7. 'RC' denotes reinforced concrete.
8. 'd.p.c' denotes one layer of bituminous felt
to be provided under all walls on Ground Floor Slab.
9. All construction work is to comply with the latest
10
KBS standard codes of practice, local Authority
8
9
11
8 Bye-Laws and Fire regulations.
10. Water meters to be 300mm above G. L.
12

8
13

7
11. Provide 2 no. row of 600x600x50mm precast
DAYCARE PP 1 concrete paving slabs around the building unless
14

6
3,000

3,000
Custom Text
otherwise shown/indicated.
15

CLASSROOM CLASSROOM GRADE 1 GRADE 3


5

12.All levels shown are finished levels unless otherwise


16

stated.
CLASSROOM CLASSROOM
17

13. All surface beds to be cast on well compacted


18

1
19
and well consolidated filling.
UP
14. Depth of foundation trenches to be minimum
DOWN

7 7
600mm below reduced ground level.
15. All pipes and services to be minimum 450mm
below reduced ground level.
3,000

3,000
16. This drawing is protected under the Copyright Act,
and cannot be used or reproduced in part or in
whole without the authors' consent.

Revisions
6 6
Item Date Description Remarks

SIDE
3,900

3,900
PASSAGE PASSAGE PASSAGE ENTRANCE
25,150

25,150
02

04
5 5

ACCOUNTANT
3,000

3,000
PRINTING
HEAD TEACHER
GABRIM ARCHITECTS LTD.
ROOM
P.o.Box 14716 - 00400
Nairobi
4 4

Cell: 0727 115 499


3,000

3,000
DAYCARE STAFF PP2
CLASSROOM ROOM CLASSROOM
PROJECT:

3
LOBBY 3
PROPOSED CONSTRUCTION OF GENTLE SHEPHERD
CLASSROOMS

DIRECTOR CLIENT:
3,000

3,000
RECEPTION/
SECRETARY
WAITING
CLIENT SIGN: ..........................................

DRAWING TITLE :
2 2

GROUND, FIRST & SECOND FLOOR LAYOUT PLANS,


ELEVATIONS AND SECTION
3,000

3,000
ENTRANCE SCHEDULES:
PORCH Window schedule
Ref WXH Qtty Description

1 1

2,700 2,700 2,700 2,700 2,700 2,700 3,300 H 2,700 2,700 2,700 2,700 2,700 2,700 2,050 Door schedule:
Ref WXH Qtty Description

A B C D E F G 38,000 I J K L M N O

01

GROUND FLOOR LAYOUT PLAN Scale 1:75


DATE SEP , 2023

SCALE 1:50 & 1:100

DRAWN BY A. A Simon O. Ogolla

CHECKED BY Arch. Gabriel Rimo M.


DRG NO.
001

GSPublisherVersion
GSPublisherVersion
GSPublisherVersion 0.0.100.76
0.0.100.100
0.0.100.100
NOTES
1. Dimensions are in millimetres and should be read
from the drawing and not scaled. Any discrepancies
noted should be reported to the project architect
before works commence.
2.All structural works to structural engineer's details
03 3. 'pv' denotes permanent ventilation and shall be
provided at all positions shown on the drawing.
35,900
A B C D E F G I J K L M N O
All windows and doors to have PV except toilet doors.
4. All drain pipes passing under buildings to be
2,700 2,700 2,700 2,700 2,700 2,700 3,300 2,700 2,700 2,700 2,700 2,700 2,700 encased in 150mm concrete surround.
H

5. All walls to have hoop iron reinforcement at


alternate courses.
9 9
6. 'IC' denotes inspection chamber.
7. 'RC' denotes reinforced concrete.
8. 'd.p.c' denotes one layer of bituminous felt
to be provided under all walls on Ground Floor Slab.
3,000

3,000
9. All construction work is to comply with the latest
KBS standard codes of practice, local Authority
STAIRS Bye-Laws and Fire regulations.
10
10. Water meters to be 300mm above G. L.
11. Provide 2 no. row of 600x600x50mm precast
11
8 8
9

8
12
concrete paving slabs around the building unless
13
otherwise shown/indicated.
7
14
12.All levels shown are finished levels unless otherwise
stated.
6

GRADE 6 GRADE 4 JUNIOR SEC 7 JUNIOR SEC 8


3,000

3,000
Custom Text
15

5
16
13. All surface beds to be cast on well compacted
CLASSROOM CLASSROOM CLASSROOM CLASSROOM and well consolidated filling.
4
17

14. Depth of foundation trenches to be minimum


3
18

2
19
600mm below reduced ground level.
15. All pipes and services to be minimum 450mm
1
UP
DOWN

7 7
below reduced ground level.
16. This drawing is protected under the Copyright Act,
and cannot be used or reproduced in part or in
whole without the authors' consent.
3,000

3,000
Revisions
Item Date Description Remarks

6 6
3,900

3,900
PASSAGE PASSAGE PASSAGE
24,900

24,900
02

04
5 5

GABRIM ARCHITECTS LTD.


3,000

3,000
P.o.Box 14716 - 00400
Nairobi
Cell: 0727 115 499
4 4
3,000

3,000
GRADE 5 JUNIOR SEC 9 PROJECT:
CLASSROOM COMPUTER LIBRARY CLASSROOM PROPOSED CONSTRUCTION OF GENTLE SHEPHERD
LAB LIBRARIAN/ CLASSROOMS
3
LAB BOOK 3

TECHNICIAN STORE CLIENT:


3,000

3,000
CLIENT SIGN: ..........................................

DRAWING TITLE :
GROUND, FIRST & SECOND FLOOR LAYOUT PLANS,
2 2 ELEVATIONS AND SECTION

SCHEDULES:
Window schedule
3,000

3,000
Ref WXH Qtty Description

1 1

Door schedule:
Ref WXH Qtty Description

2,700 2,700 2,700 2,700 2,700 2,700 3,300 H 2,700 2,700 2,700 2,700 2,700 2,700

A B C D E F G 35,900 I J K L M N O

01

FIRST FLOOR LAYOUT PLAN Scale 1:75


DATE SEP , 2023

SCALE 1:50 & 1:100

DRAWN BY A. A Simon O. Ogolla

CHECKED BY Arch. Gabriel Rimo M.


DRG NO.
001

GSPublisherVersion
GSPublisherVersion
GSPublisherVersion 0.0.100.76
0.0.100.100
0.0.100.100
NOTES
1. Dimensions are in millimetres and should be read
from the drawing and not scaled. Any discrepancies
noted should be reported to the project architect
before works commence.
2.All structural works to structural engineer's details
3. 'pv' denotes permanent ventilation and shall be
provided at all positions shown on the drawing.
All windows and doors to have PV except toilet doors.
4. All drain pipes passing under buildings to be
encased in 150mm concrete surround.
5. All walls to have hoop iron reinforcement at
alternate courses.
6. 'IC' denotes inspection chamber.
7. 'RC' denotes reinforced concrete.
8. 'd.p.c' denotes one layer of bituminous felt
to be provided under all walls on Ground Floor Slab.
9. All construction work is to comply with the latest
KBS standard codes of practice, local Authority
Bye-Laws and Fire regulations.
10. Water meters to be 300mm above G. L.
11. Provide 2 no. row of 600x600x50mm precast
concrete paving slabs around the building unless
otherwise shown/indicated.
12.All levels shown are finished levels unless otherwise
stated.
13. All surface beds to be cast on well compacted
and well consolidated filling.
14. Depth of foundation trenches to be minimum
600mm below reduced ground level.
15. All pipes and services to be minimum 450mm
below reduced ground level.
16. This drawing is protected under the Copyright Act,
and cannot be used or reproduced in part or in
whole without the authors' consent.

Revisions
Item Date Description Remarks

GABRIM ARCHITECTS LTD.


P.o.Box 14716 - 00400
Nairobi
Cell: 0727 115 499

PROJECT:
PROPOSED CONSTRUCTION OF GENTLE SHEPHERD
CLASSROOMS

CLIENT:

CLIENT SIGN: ..........................................

DRAWING TITLE :
GROUND, FIRST & SECOND FLOOR LAYOUT PLANS,
ELEVATIONS AND SECTION

SCHEDULES:
Window schedule
Ref WXH Qtty Description

Door schedule:
Ref WXH Qtty Description

DATE SEP , 2023

SCALE 1:50 & 1:100

DRAWN BY A. A Simon O. Ogolla

CHECKED BY Arch. Gabriel Rimo M.


DRG NO.
001

GSPublisherVersion
GSPublisherVersion
GSPublisherVersion 0.0.100.76
0.0.100.100
0.0.100.100
NOTES
1. Dimensions are in millimetres and should be read
from the drawing and not scaled. Any discrepancies
noted should be reported to the project architect
before works commence.
2.All structural works to structural engineer's details
3. 'pv' denotes permanent ventilation and shall be
provided at all positions shown on the drawing.
All windows and doors to have PV except toilet doors.
4. All drain pipes passing under buildings to be
encased in 150mm concrete surround.
5. All walls to have hoop iron reinforcement at
alternate courses.
6. 'IC' denotes inspection chamber.
7. 'RC' denotes reinforced concrete.
8. 'd.p.c' denotes one layer of bituminous felt
to be provided under all walls on Ground Floor Slab.
9. All construction work is to comply with the latest
KBS standard codes of practice, local Authority
Bye-Laws and Fire regulations.
10. Water meters to be 300mm above G. L.
11. Provide 2 no. row of 600x600x50mm precast
concrete paving slabs around the building unless
otherwise shown/indicated.
12.All levels shown are finished levels unless otherwise
stated.
13. All surface beds to be cast on well compacted
and well consolidated filling.
14. Depth of foundation trenches to be minimum
600mm below reduced ground level.
15. All pipes and services to be minimum 450mm
below reduced ground level.
16. This drawing is protected under the Copyright Act,
and cannot be used or reproduced in part or in
whole without the authors' consent.

Revisions
Item Date Description Remarks

GABRIM ARCHITECTS LTD.


P.o.Box 14716 - 00400
Nairobi
Cell: 0727 115 499

PROJECT:
PROPOSED CONSTRUCTION OF GENTLE SHEPHERD
CLASSROOMS

CLIENT:

CLIENT SIGN: ..........................................

DRAWING TITLE :
GROUND, FIRST & SECOND FLOOR LAYOUT PLANS,
ELEVATIONS AND SECTION

SCHEDULES:
Window schedule
Ref WXH Qtty Description

FRONT VIEW
Door schedule:
Ref WXH Qtty Description

DATE SEP , 2023

SCALE 1:50 & 1:100

DRAWN BY A. A Simon O. Ogolla

CHECKED BY Arch. Gabriel Rimo M.


DRG NO.
001

GSPublisherVersion
GSPublisherVersion
GSPublisherVersion 0.0.100.76
0.0.100.100
0.0.100.100
NOTES
1. Dimensions are in millimetres and should be read
from the drawing and not scaled. Any discrepancies
noted should be reported to the project architect
before works commence.
2.All structural works to structural engineer's details
3. 'pv' denotes permanent ventilation and shall be
provided at all positions shown on the drawing.
All windows and doors to have PV except toilet doors.
4. All drain pipes passing under buildings to be
encased in 150mm concrete surround.
5. All walls to have hoop iron reinforcement at
alternate courses.
6. 'IC' denotes inspection chamber.
7. 'RC' denotes reinforced concrete.
8. 'd.p.c' denotes one layer of bituminous felt
to be provided under all walls on Ground Floor Slab.
9. All construction work is to comply with the latest
KBS standard codes of practice, local Authority
Bye-Laws and Fire regulations.
10. Water meters to be 300mm above G. L.
11. Provide 2 no. row of 600x600x50mm precast
concrete paving slabs around the building unless
otherwise shown/indicated.
12.All levels shown are finished levels unless otherwise
stated.
13. All surface beds to be cast on well compacted
and well consolidated filling.
14. Depth of foundation trenches to be minimum
600mm below reduced ground level.
15. All pipes and services to be minimum 450mm
below reduced ground level.
16. This drawing is protected under the Copyright Act,
and cannot be used or reproduced in part or in
whole without the authors' consent.

Revisions
Item Date Description Remarks

GABRIM ARCHITECTS LTD.


P.o.Box 14716 - 00400
Nairobi
Cell: 0727 115 499

PROJECT:
PROPOSED CONSTRUCTION OF GENTLE SHEPHERD
CLASSROOMS

CLIENT:

CLIENT SIGN: ..........................................

DRAWING TITLE :
GROUND, FIRST & SECOND FLOOR LAYOUT PLANS,
ELEVATIONS AND SECTION

SCHEDULES:
Window schedule
Ref WXH Qtty Description

Door schedule:

MAIN ENTRANCE Ref WXH Qtty Description

DATE SEP , 2023

SCALE 1:50 & 1:100

DRAWN BY A. A Simon O. Ogolla

CHECKED BY Arch. Gabriel Rimo M.


DRG NO.
001

GSPublisherVersion
GSPublisherVersion
GSPublisherVersion 0.0.100.76
0.0.100.100
0.0.100.100
NOTES
1. Dimensions are in millimetres and should be read
from the drawing and not scaled. Any discrepancies
noted should be reported to the project architect
before works commence.
2.All structural works to structural engineer's details
3. 'pv' denotes permanent ventilation and shall be
provided at all positions shown on the drawing.
All windows and doors to have PV except toilet doors.
4. All drain pipes passing under buildings to be
encased in 150mm concrete surround.
5. All walls to have hoop iron reinforcement at
alternate courses.
6. 'IC' denotes inspection chamber.
7. 'RC' denotes reinforced concrete.
8. 'd.p.c' denotes one layer of bituminous felt
to be provided under all walls on Ground Floor Slab.
9. All construction work is to comply with the latest
KBS standard codes of practice, local Authority
Bye-Laws and Fire regulations.
10. Water meters to be 300mm above G. L.
11. Provide 2 no. row of 600x600x50mm precast
concrete paving slabs around the building unless
otherwise shown/indicated.
12.All levels shown are finished levels unless otherwise
stated.
13. All surface beds to be cast on well compacted
and well consolidated filling.
14. Depth of foundation trenches to be minimum
600mm below reduced ground level.
15. All pipes and services to be minimum 450mm
below reduced ground level.
16. This drawing is protected under the Copyright Act,
and cannot be used or reproduced in part or in
whole without the authors' consent.

Revisions
Item Date Description Remarks

GABRIM ARCHITECTS LTD.


P.o.Box 14716 - 00400
Nairobi
Cell: 0727 115 499

PROJECT:
PROPOSED CONSTRUCTION OF GENTLE SHEPHERD
CLASSROOMS

CLIENT:

CLIENT SIGN: ..........................................

DRAWING TITLE :
GROUND, FIRST & SECOND FLOOR LAYOUT PLANS,
ELEVATIONS AND SECTION

SCHEDULES:
Window schedule
Ref WXH Qtty Description

SIDE VIEW
Door schedule:
Ref WXH Qtty Description

DATE SEP , 2023

SCALE 1:50 & 1:100

DRAWN BY A. A Simon O. Ogolla

CHECKED BY Arch. Gabriel Rimo M.


DRG NO.
001

GSPublisherVersion
GSPublisherVersion
GSPublisherVersion 0.0.100.76
0.0.100.100
0.0.100.100
NOTES
1. Dimensions are in millimetres and should be read
from the drawing and not scaled. Any discrepancies
noted should be reported to the project architect
before works commence.
2.All structural works to structural engineer's details
3. 'pv' denotes permanent ventilation and shall be
provided at all positions shown on the drawing.
All windows and doors to have PV except toilet doors.
4. All drain pipes passing under buildings to be
encased in 150mm concrete surround.
5. All walls to have hoop iron reinforcement at
alternate courses.
6. 'IC' denotes inspection chamber.
7. 'RC' denotes reinforced concrete.
8. 'd.p.c' denotes one layer of bituminous felt
to be provided under all walls on Ground Floor Slab.
9. All construction work is to comply with the latest
KBS standard codes of practice, local Authority
Bye-Laws and Fire regulations.
10. Water meters to be 300mm above G. L.
11. Provide 2 no. row of 600x600x50mm precast
concrete paving slabs around the building unless
otherwise shown/indicated.
12.All levels shown are finished levels unless otherwise
stated.
13. All surface beds to be cast on well compacted
and well consolidated filling.
14. Depth of foundation trenches to be minimum
600mm below reduced ground level.
15. All pipes and services to be minimum 450mm
below reduced ground level.
16. This drawing is protected under the Copyright Act,
and cannot be used or reproduced in part or in
whole without the authors' consent.

Revisions
Item Date Description Remarks

GABRIM ARCHITECTS LTD.


P.o.Box 14716 - 00400
Nairobi
Cell: 0727 115 499

PROJECT:
PROPOSED CONSTRUCTION OF GENTLE SHEPHERD
CLASSROOMS

CLIENT:

CLIENT SIGN: ..........................................

DRAWING TITLE :
GROUND, FIRST & SECOND FLOOR LAYOUT PLANS,
ELEVATIONS AND SECTION

SCHEDULES:
Window schedule
Ref WXH Qtty Description

SIDE ENTRANCE
Door schedule:
Ref WXH Qtty Description

DATE SEP , 2023

SCALE 1:50 & 1:100

DRAWN BY A. A Simon O. Ogolla

CHECKED BY Arch. Gabriel Rimo M.


DRG NO.
001

GSPublisherVersion
GSPublisherVersion
GSPublisherVersion 0.0.100.76
0.0.100.100
0.0.100.100
NOTES
1. Dimensions are in millimetres and should be read
from the drawing and not scaled. Any discrepancies
noted should be reported to the project architect
before works commence.
2.All structural works to structural engineer's details
3. 'pv' denotes permanent ventilation and shall be
provided at all positions shown on the drawing.
All windows and doors to have PV except toilet doors.
4. All drain pipes passing under buildings to be
encased in 150mm concrete surround.
5. All walls to have hoop iron reinforcement at
alternate courses.
6. 'IC' denotes inspection chamber.
7. 'RC' denotes reinforced concrete.
8. 'd.p.c' denotes one layer of bituminous felt
to be provided under all walls on Ground Floor Slab.
9. All construction work is to comply with the latest
KBS standard codes of practice, local Authority
Bye-Laws and Fire regulations.
10. Water meters to be 300mm above G. L.
11. Provide 2 no. row of 600x600x50mm precast
concrete paving slabs around the building unless
otherwise shown/indicated.
12.All levels shown are finished levels unless otherwise
stated.
13. All surface beds to be cast on well compacted
and well consolidated filling.
14. Depth of foundation trenches to be minimum
600mm below reduced ground level.
15. All pipes and services to be minimum 450mm
below reduced ground level.
16. This drawing is protected under the Copyright Act,
and cannot be used or reproduced in part or in
whole without the authors' consent.

Revisions
Item Date Description Remarks

GABRIM ARCHITECTS LTD.


P.o.Box 14716 - 00400
Nairobi
Cell: 0727 115 499

PROJECT:
PROPOSED CONSTRUCTION OF GENTLE SHEPHERD
CLASSROOMS

CLIENT:

CLIENT SIGN: ..........................................

DRAWING TITLE :
GROUND, FIRST & SECOND FLOOR LAYOUT PLANS,
ELEVATIONS AND SECTION

SCHEDULES:
Window schedule
Ref WXH Qtty Description

REAR VIEW
Door schedule:
Ref WXH Qtty Description

DATE SEP , 2023

SCALE 1:50 & 1:100

DRAWN BY A. A Simon O. Ogolla

CHECKED BY Arch. Gabriel Rimo M.


DRG NO.
001

GSPublisherVersion
GSPublisherVersion
GSPublisherVersion 0.0.100.76
0.0.100.100
0.0.100.100
NOTES
1. Dimensions are in millimetres and should be read
from the drawing and not scaled. Any discrepancies
noted should be reported to the project architect
before works commence.
2.All structural works to structural engineer's details
3. 'pv' denotes permanent ventilation and shall be
provided at all positions shown on the drawing.
All windows and doors to have PV except toilet doors.
4. All drain pipes passing under buildings to be
encased in 150mm concrete surround.
5. All walls to have hoop iron reinforcement at
alternate courses.
6. 'IC' denotes inspection chamber.
7. 'RC' denotes reinforced concrete.
8. 'd.p.c' denotes one layer of bituminous felt
to be provided under all walls on Ground Floor Slab.
9. All construction work is to comply with the latest
KBS standard codes of practice, local Authority
Bye-Laws and Fire regulations.
10. Water meters to be 300mm above G. L.
11. Provide 2 no. row of 600x600x50mm precast
concrete paving slabs around the building unless
otherwise shown/indicated.
12.All levels shown are finished levels unless otherwise
stated.
13. All surface beds to be cast on well compacted
and well consolidated filling.
14. Depth of foundation trenches to be minimum
600mm below reduced ground level.
15. All pipes and services to be minimum 450mm
below reduced ground level.
16. This drawing is protected under the Copyright Act,
and cannot be used or reproduced in part or in
whole without the authors' consent.

Revisions
Item Date Description Remarks

GABRIM ARCHITECTS LTD.


P.o.Box 14716 - 00400
Nairobi
Cell: 0727 115 499

PROJECT:
PROPOSED CONSTRUCTION OF GENTLE SHEPHERD
CLASSROOMS

CLIENT:

CLIENT SIGN: ..........................................

DRAWING TITLE :
GROUND, FIRST & SECOND FLOOR LAYOUT PLANS,
ELEVATIONS AND SECTION

SCHEDULES:
Window schedule
Ref WXH Qtty Description

AIRIAL VIEW OF BACK VIEW


Door schedule:
Ref WXH Qtty Description

DATE SEP , 2023

SCALE 1:50 & 1:100

DRAWN BY A. A Simon O. Ogolla

CHECKED BY Arch. Gabriel Rimo M.


DRG NO.
001

GSPublisherVersion
GSPublisherVersion
GSPublisherVersion 0.0.100.76
0.0.100.100
0.0.100.100

You might also like