You are on page 1of 1

GENERAL

1. This drawing must be read in conjuction


with relevant engineer's and architectural
drawing(s).
2. The contractor shall check all dimensions
on site, any error, &/or ommisions shall be
reported to the engineer before
2 work is commenced.
C1 C1 C1 C1 3.The latest ammendment or revision shall
superceed all other issues which shall be
B1 B1 B1 B1 destroyed

1150
2
C1 C1 C1 C1 CONCRETE
1. Blinding under pad foundation to be 1:4:8 mix
B1 B2 B1 B1 2Y16-01 2. All reinforced concrete to be grade 25 mix
Y12-150T1 giving a minimum crushing strength of
25N/mm2 of 28 days.
3. Cement shall be portland cement to comply
3150

with BS 12
1 1 Y12-150B1 4.Maximum aggregate size shall be 20mm unless

1425
Y12-150T1 otherwise stated.
T 2)
+
1300 ( B2 2Y16-02 REINFORCEMENT
0 1. R indicate hot rolled mild steel to BS4449
C1 C1 C1 C1 15
Y12-150T1 1 0- 2. Y indicate cold rolled high tensile steel to BS4461
Y
B1 B2 B2 B1 3.Fabric reinforcement shall be to BS4483.
1250

4. All reinforcement shall be presented to the


C1 engineer for inspection prior to concreting.
C1 C1 Y12-150B1
T 2)
2+

1425
Y12-150T1 COVER
B1 B2 ( B
1075

B3 150 Unless otherwise stated cover to main steel shall


0- be as follows:
Y1
BRC MESH 1. 50mm to all steel below ground level
2. 40mm to columns above ground level
3350 2650 1350 3. 25mm to steel in beams.
4. 20mm to steel in slabs and staircase.
STAIRCASE DETAILS
SCALE 1:50 WORKMANSHIP
1. All concrete work to be in accordance with BS 8110.
2. All reinforced concrete to be mechanically vibrated.
3. All load bearing blockwork shall be in accordance
FOUNDATION LAYOUT with CP 111.

SCALE 1:50 EXCAVATION


1. All excavations for foundation shall be
presented to the engineer for his approval
prior to placing of blinding.
2. Depth of foundation on all drawings are
provisionaland the engineer shall be consulted before
final depthis arrived at during construction.
DPC
DPC

Reinforcement Mesh (A61)


Reinforcement Mesh (A61) LEGEND
150mm Concrete Slab 1. T1 Top first layer
150mm Concrete Slab
DPM 1000 Gauge Polyethene
DPM 1000 Gauge Polyethene 2. T2 Top second layer
50mm Murram/Quarry dust blinding
50mm Murram/Quarry dust blinding 3. B1 Bottom first layer
300mm Hardcore well 4. B2 Bottom second layer
300mm Hardcore well compacted
compacted

PROJECT
Y12-02-200
Y12-02-200
Y12-01-200
PROPOSED CONSTRUCTION OF A
Y12-01-200
COMMERCIAL BUILDING ON PLOT No.
50mm concrete blinding
50mm concrete blinding (1:4:8mix)
93B KUTUS MJINI
(1:4:8mix)

EXTERNAL STRIP SECTION 2-2 INTERNAL STRIP SECTION 1-1


CLIENT
SCALE 1:25
SCALE 1:25 FRANCIS MURIITHI NGARI
P.O BOX 87
KUTUS

REV. DATE
1000
400 200 400 1100 1500
450 200 450 650 200 650
400

650
450

200
5T16-250

200 200
Structural drawing
1000
200

200

7T16-250
5T16-250

1500
1100

200

200
200

200

5T16-250
400

DESIGNED BY: JOB NO. 04-19


5T16-250 7T16-250
650
450

DRAWN BY: NYAGA DRG. NO. 04-19


BASE B1 DETAIL
SCALE 1:25 BASE B2 BASE B3 DETAILS
CHECKED BY: DATE SEP 2019
SCALE 1:25 SCALE 1:25

SCALE : AS INDICATED SHEET 02