Professional Documents
Culture Documents
The design on this drawing is copyright and remains the property of the undermentioned
Engineers
All levels and dimensions are to be checked on site prior to the commencement
of work.
This drawing must not be scaled, only figured dimensions and levels may be used. Any
discrepancies must be settled beforehand with the Engineer
This drawing to be read in conjuction with Architectural, Civil, Electrical and Mechanical
Engineers drawings.
All work is to be carried out strictly in accordance with the Local Authority
requirements, the National Building Regulations and the SABS standards.
GENERAL NOTES
re
lbo
CATCHMENT AREAS Ful t
Ø
75 outle NEW FLOW DIRECTION
re
Area10
FLOW DIRECTION lbo
Ful t
NEW 75 Ø FULLBORE OUTLET ore
Ø ore F ullb
75 outle Fullb 75Ø outlet
re
75Ø outlet lbo
Ful
ore EXISTING 75 Ø FULLBORE 7 5Ø et Area10
F ullb New out
l re
75Ø outlet Area4 OUTLET lbo
re lbo
Ful t Ful
Ø lb ore 7 5 Ø
75 outle Ful let
re New out
75Ø outlet lbo
e Ø Ful
r 5
Area11 lbo 7 let
Ful t New out
F ullb
ore Ø
75 outle Area4
e
bor
e 75Ø outlet lbor
Ful
l
Ø Ful t
75Ø outlet 5
7 out e l
ore ore
Area11
F ullb lbo
re
F ullb
75Ø outlet Ful t re 75Ø outlet ore
75Ø RW SPOUT Ø
75 outle lbo
Ful t F ullb
oo f1 Ø
75 outle 75Ø outlet
Area7 Area3 a R
Are r e
lbo ore
Ø Ful t ullb
75Ø RW SPOUT 75 outle F
75Ø outlet
Area2 oo f1
lb o
Ful t
re
Area7 Area3 e a R
5 Ø
7 outle Ar
ore
Fullb
75Ø outlet Area2
ore New 75Ø Fullbore NOTE:
F ullb outlet
ore 75Ø Fullbore 75Ø outlet
F ullb New 75Ø 1. SCREED SURFACE OF THE FLAT ROOF TO
75Ø outlet
outlet ore
Fullb Fullbore FACILITATE ROOF DRAINAGE
75Ø outlet outlet 2. FLAT ROOF TO DRAIN AT 0.5% TO SPECIFIED
REVISIONS
Area roof 2 ore 75Ø Fullbore
DIRECTION
Area8 75Ø Fullbore F ullb outlet
3.
4.
REROUTE STORMWATER TO DOWNPIPES
FLOW DIRECTIONS ARE INDICATED BY THE ARROWS.
No. DATE DESCRIPTION
75Ø outlet ISSUED FOR INFORMATION
A 20/03/23
outlet 5. PROVIDE ADDITIONAL DOWNPIPES AS INDICATED
75Ø Fullbore
Area roof 2
75Ø Fullbore 75Ø Fullbore
Area1 outlet
Area8 75Ø Fullbore
New 75Ø Fullbore
outlet
outlet 75Ø RW SPOUT
outlet 75Ø Fullbore outlet
outlet
Area9 75Ø Fullbore
ISSUED FOR CONSTRUCTION
75Ø Fullbore
outlet
75Ø Fullbore 75Ø Fullbore
Area1 outlet
outlet 75Ø RW SPOUT
outlet 75Ø Fullbore Province
outlet
Area9
75Ø Fullbore
75Ø Fullbore
Area6 outlet Area Roof 3
outlet
New 75Ø Fullbore GAUTENG
New 75Ø Fullbore
outlet outlet
Area5 75Ø Fullbore
75Ø Fullbore
75Ø Fullbore outlet Area6 outlet Area Roof 3 Client:
outlet
75Ø RW SPOUT
75Ø Fullbore 75Ø Fullbore
Area5 75Ø Fullbore
outlet
Area12 outlet 75Ø Fullbore outlet VAN EEDEN
outlet
75Ø Fullbore
outlet 75Ø RW SPOUT
75Ø Fullbore 75Ø Fullbore New 75Ø Fullbore
outlet outlet outlet
Area12 Consultants
75Ø Fullbore
outlet
ROOF CATCHMENT
SCALE 1 : 100
PROPOSED NEW DOWN PIPES 40 Richard Park, Tel: +27 83 595 4403
Buccleuch,2090. Email:info@4miles.co.za
SCALE 1 : 100 Johannesburg.
Approvals
Discipline
Structural
Project Title
PROPOSED RESIDENTIAL
HOUSE ON STAND
694 WATERBUCK CRESCENT,
KEMPTON PARK
Drawing title
CATCHMENT AREA
Drawing.No. Revision.No.
ROOF CATCHMENTS & FLOW DIRECTION
SCALE AS SHOWN VANEEDEN/S/ST/02 A