You are on page 1of 2

JRDVQDEYJBHRX5CV (Fenerbahce_Do Not Use COMMERCIAL)

Beam Reinforcement Design Calc. By:


Rev: 1 Checked By:

Beam Reinforcement Design


Axis: 8 Storey: 1
Materials: C25/30 / Grade 460 (Type 2) (Links: Grade 460 (Type 2)) Concrete Cover: 25.0 mm

Diagrams

Bending
1B15 L= 3025mm
Bw x H (mm) 200 x 600
Flange Bf x
Hf
---
(Left)
(Right)
Top Edge
M (kN.m) 0.7 0.0 0.0
d (mm) 559.0 559.0 559.0
K/K' 0.00 0.00 0.00
x (mm) 62.4 62.1 62.1
As (mm2) 0.00 0.00 0.00
As' (mm2) 0.00 0.00 0.00
As,min (mm2) 0.00 0.00 0.00
Bottom Edge
M (kN.m) 18.8 33.0 18.2
d (mm) 559.0 559.0 559.0
K/K' 0.06 0.11 0.06
x (mm) 62.1 62.1 62.1
As (mm2) 0.00 0.00 85.53
As' (mm2) 0.00 0.00 0.00
As,min (mm2) 0.00 0.00 0.00

Shear And Torsion Design


Vd (kN) 38.1 36.8
v (MPa) 0.34 0.33
vc (MPa) 0.44 0.44
vMax (MPa) 4.38 4.38
Vnom (kN) 127.6
Td (kN.m) 0.1
vt (MPa) 0.00
vt,min (MPa) 0.00
bsupport (mm) 0.0 0.0
Links 1T8-300

Deflection Check
5.41 ≤ 40.0
L/d

Steel Areas (mm2)

ProtaStructure v5.1.252 Page 1


JRDVQDEYJBHRX5CV (Fenerbahce_Do Not Use COMMERCIAL)
Beam Reinforcement Design Calc. By:
Rev: 1 Checked By:

Required
Top Edge 0.00
Bottom Edge 85.53
Supplied
Top Edge 402.12
Bottom Edge 402.12
Steel Bars
Top Bars
Top.Sup.Bars 2T16
Top.Sup.Bars
Bottom Bars 2T16
Bottom Bars
Bot.Sup.Bars
Side Bars

ProtaStructure v5.1.252 Page 2