You are on page 1of 1

Aspen Exchanger Design and Rating Shell & Tube V11

File: Printed: 12/21/2023 at 12:45:21 PM

Flow Analysis

Shell Side Flow Fractions Inlet Middle Outlet Diameter Clearance


mm
Crossflow (B stream) 0.25 0.25 0.25
Window (B+C+F stream) 0.98 0.92 0.98
Baffle hole - tube OD (A stream) 0 0.01 0 0.79
Baffle OD - shell ID (E stream) 0.02 0.07 0.02 4.76
Shell ID - bundle OTL (C stream) 0.43 0.4 0.43 47.62
Pass lanes (F stream) 0.3 0.27 0.3

Rho*V2 Analysis Flow Area Velocity Density Rho*V2 TEMA limit


mm² m/s kg/m³ kg/(m-s²) kg/(m-s²)
Shell inlet nozzle 32275 1.06 973.91 1086 2232
Shell entrance 43879 0.78 973.91 588 5953
Bundle entrance 102859 0.33 973.91 107 5953
Bundle exit 82839 0.42 963.23 167 5953
Shell exit 21415 1.61 963.23 2494 5953
Shell outlet nozzle 18639 1.85 963.23 3293
mm² m/s kg/m³ kg/(m-s²) kg/(m-s²)
Tube inlet nozzle 4769 13.43 10.06 1814
Tube inlet 14171 4.52 10.06 205
Tube outlet 12961 0.06 844.23 3
Tube outlet nozzle 464 1.64 844.23 2284