Line BC Phase
• Phase Voltage = 115 V (A fazı)
• Line Voltage = Phase Voltage * √3
• Line Voltage = 115V * √3 = 200 V(BC fazı)
Engine Driven Generator
Generator Control Unit (GCU)
• GCU controls individual generator
functions.
• Gen. Circuit Breaker controlled by GCU.
• Includes auto open or close.
• Monitors generator voltage, frequency and
phase rotation.
• Controls voltage regulator.
AC Supply Control
• AC Generator (3 Phase AC).
• Generator control breaker.
• 3 Phase AC output from generator.
• Mechanically latched switch request GCB closure
• Electrical control of GCB normally automatic
GCU
• GCU will connect generator to Busbar if:
• Voltage within limits (e.g. 115V ± 4V)
• Frequency within limits (e.g. 400 ± 10Hz)
• Under voltaj(110 V ve aşağısı) yada over
voltaj(120 V ve üstü) durumunda
GCB(Generator Circuit Breaker)’ı açar.
Frequency Wild AC
• Aircraft that don’t require large amounts of AC can
operate this system.(turboprop)
• Frequency varies with RPM but voltage is strictly
controlled
• Frequency wild generators cannot be connected in
parallel, so Generators supply independent busbars
• Busbars can be coupled (tied) following generator failure
• The AC wild busbars will power AC consumers that do not
require constant frequency. eg de icing systems.
Frequency Wild AC System
• 115V AC 3 Phase
• Can be converted to 28v DC provided by a
transformer rectifier unit
Frequency Wild AC
• Constant frequency AC still required
• DC inverter converts 28 V DC to:
• Single phase 115V AC 400Hz or,
• 26V AC for electronics – flight
instruments
Frequency Wild System
Değişken frekans
sağladığı için paralel
bağlanamazlar – split
buses