Professional Documents
Culture Documents
element-1644
Known Data
Size of column
fck
fy
Axial Load (Pu)
Critical moment along X-X axis (Mux')
Critical moment along Y-Y axis (Muy')
Unsupported Length (L)= Clear length/height between floor n lower level of celling
Effective length (Le) = 0.65 * L
Least dimension (D)
Slenderness ratio (Le/D)
Mux = Pu * emin
Muy = PU * emin
Pz = 0.45*fck*Ac+0.75*fy*Asc
Pu/Pz
Range of Pu/Pz = 0.2 - 0.8 and αn=1 - 2
By interpolation, α
(Mux/Mu1)^α + (Muy/Muy1)^α
Area of longitudional reinforcement = Pt * Ag
Provide,
Provide 14-32mm and 9-25mm
Provide…..
Special confining reinforcement shall be Provided over the length Lo from each joint face.
a large lateral imension of the member =
b 1/6 of clear height of column =
c 450mm
Adopt Lo
The spacing of hoops shall not exceed half of least lateral dimension <
Adopt, =
620*620 mm2
25 N/mm2
415 N/mm2
3430.017 KN
706.6228 KN-m
8.0492 KN-m
2.725 m
1.771 m
620 mm
2.857 < 12 i.e Short column
20.6721167 mm
60 mm
0.09677419
4
0.16
0.35692164
0.19
1132.058 KN-m
0.09677419
0.19
1132.058 KN-m
8937.3 KN
0.38378671
1.31