Design of Column

element-1644
Known Data
Size of column
fck
fy
Axial Load (Pu)
Critical moment along X-X axis (Mux')
Critical moment along Y-Y axis (Muy')

Unsupported Length (L)= Clear length/height between floor n lower level of celling
Effective length (Le) = 0.65 * L
Least dimension (D)
Slenderness ratio (Le/D)

Check for minimum eccentricity (emin)


emin = L/500 +d/30

Mux = Pu * emin
Muy = PU * emin

Design as axial load with biaxial bending


Assumption : Bars are distributed equally four sides
Effective cover d'

about x -x axis d'/D


Assume the % of steel (Pt)
Pt/fck
Pu/(fck*b*d)
Mu/(fck*b*D2)
for square column
Mux1

about y -y axis d'/D


Mu/(fck*b*D2)
Muy1

Pz = 0.45*fck*Ac+0.75*fy*Asc
Pu/Pz
Range of Pu/Pz = 0.2 - 0.8 and αn=1 - 2
By interpolation, α

(Mux/Mu1)^α + (Muy/Muy1)^α
Area of longitudional reinforcement = Pt * Ag
Provide,
Provide 14-32mm and 9-25mm

Design of Lateral ties


ΦT not less than ΦL/4 but not less than 6mm
ΦT
Adopt ΦT
Pitch<least lateral dimension or 16ΦL or 300 mm whichever is less
Therefore, P<lateral dimension <
or, P< 16ΦL <
or,P<300 <
Adopt, Pitch, P =

Provide…..

Special confining reinforcement shall be Provided over the length Lo from each joint face.
a large lateral imension of the member =
b 1/6 of clear height of column =
c 450mm

Adopt Lo
The spacing of hoops shall not exceed half of least lateral dimension <
Adopt, =
620*620 mm2
25 N/mm2
415 N/mm2
3430.017 KN
706.6228 KN-m
8.0492 KN-m

2.725 m
1.771 m
620 mm
2.857 < 12 i.e Short column

20.6721167 mm

70.9057116 KN-m KN-m


70.9057116 KN-m KN-m

60 mm

0.09677419
4
0.16
0.35692164
0.19

1132.058 KN-m

0.09677419
0.19
1132.058 KN-m

8937.3 KN
0.38378671
1.31

0.54088098 < 1 safe.


15376 mm 2
15677.315 mm2