Professional Documents
Culture Documents
Naq Proc 085 Chloride Contamination Test of Hydrotest Water Procedure
Naq Proc 085 Chloride Contamination Test of Hydrotest Water Procedure
PROCEDURE
1. Scope:
1.2 The customer specifica tio n o r equ ipm en t dr a win g s pec if ies th e
quality of hydro test wa ter with r es pec t to c h lo r ide c o n ta m in a tio n in
PPM.
1.5 The procedure is applic a ble to a ll h y dr o tes ts wa ter with a s pec if ied
limit of chloride contam in a tio n .
2. Test Kits:
3. Test temperature:
The Chloride contamination testing shall be carried out at room
temperature with any one of the kits.
5.3.3 Add 10 drops of Reagent “Y”. Shake the jar until the sample terns
yellow. If yellow colour does not appear add further reagent “Y”
drop by drop and shake the jar till yellow colour is attained.
5.3.4 Add Reagent CL-25 drop by drop to the yellow coloured sample
water with gentle shake after each drop till colour changes from
yellow to Purple.