You are on page 1of 18

ULS DESIGN FORCES FOR Pile (R=1)

Pile forces at top

Element Load Case No. Axial (KN) Myy (KNm) Mzz (KNm)
687 Max P Case 1 3084 218 588
687 Min P Case 2 -806.50 207 653
ULS 770 Max My Case 3 1705 993 183
827 Min My Case 4 1637 40.60 998
827 Max Mz Case 5 1978 71 1006
645 Min Mz Case 6 1651 287 61.68

Element Load Case No. Axial (KN) Myy (KNm) Mzz (KNm)
728 Max P Case 1 1585 79 73
687 Min P Case 2 879 130 95
SLS 645 Max My Case 3 1459 232 156
847 Min My Case 4 1230 28 74
645 Max Mz Case 5 1459 232 156
770 Min Mz Case 6 1273 107 22.16

Element Load Case No. Axial (KN) Myy (KNm) Mzz (KNm)
645 Max P Case 1 956 70 29
666 Min P Case 2 922 24 11
QP 645 Max My Case 3 956 70 29
666 Min My Case 4 922 22 11
645 Max Mz Case 5 956 70 29
645 Min Mz Case 6 945 31 8
ULS DESIGN FORCES FOR Pile (R=1)

Pile forces at 6m from top

Element Load Case No. Axial (KN) Myy (KNm) Mzz (KNm)
693 Max P Case 1 3269 506 513
693 Min P Case 2 -714.32 247 518
ULS 693 Max My Case 3 2349 1090 151
776 Min My Case 4 3142 11.18 516
755 Max Mz Case 5 1928 415 534
693 Min Mz Case 6 1821 234 2.26

Element Load Case No. Axial (KN) Myy (KNm) Mzz (KNm)
734 Max P Case 1 1703 175 40
693 Min P Case 2 997 103 32
SLS 734 Max My Case 3 1703 178 40
776 Min My Case 4 1049 56 24
672 Max Mz Case 5 1398 69 52
651 Min Mz Case 6 1382 67 0.6

Element Load Case No. Axial (KN) Myy (KNm) Mzz (KNm)
651 Max P Case 1 1074 5 1
672 Min P Case 2 1040 2 0
QP 672 Max My Case 3 1042 10 1
672 Min My Case 4 1048 0 0
651 Max Mz Case 5 1074 5 1
672 Min Mz Case 6 1048 0 0
ULS DESIGN FORCES FOR Pile (R=1)

Pile forces 8m below top

Element Load Case No. Axial (KN) Myy (KNm) Mzz (KNm)
695 Max P Case 1 3330 334 367
695 Min P Case 2 -683.43 146 376
ULS 695 Max My Case 3 2407 634 106
855 Min My Case 4 1684 8.34 417
757 Max Mz Case 5 1979 243 419
653 Min Mz Case 6 1863 168 7.26

Element Load Case No. Axial (KN) Myy (KNm) Mzz (KNm)
736 Max P Case 1 1742 113 19
695 Min P Case 2 1036 61 15
SLS 736 Max My Case 3 1742 115 19
653 Min My Case 4 1605 28 27
757 Max Mz Case 5 1482 83 36
653 Min Mz Case 6 1421 51 3

Element Load Case No. Axial (KN) Myy (KNm) Mzz (KNm)
653 Max P Case 1 1113 10 4
674 Min P Case 2 1079 1 6
QP 653 Max My Case 3 1113 10 4
674 Min My Case 4 1088 0 1
653 Max Mz Case 5 1113 10 4
653 Min Mz Case 6 1102 6 1

Pile forces 9m below top


Element Load Case No. Axial (KN) Myy (KNm) Mzz (KNm)
696 Max P Case 1 3361 232 264
696 Min P Case 2 -667.93 96 273
ULS 696 Max My Case 3 2436 410 75
654 Min My Case 4 2986 10.00 267
836 Max Mz Case 5 2238 198 315
836 Min Mz Case 6 1543 53 5.30

Element Load Case No. Axial (KN) Myy (KNm) Mzz (KNm)
737 Max P Case 1 1762 79 12
696 Min P Case 2 1055 40 8
SLS 737 Max My Case 3 1762 79 12
696 Min My Case 4 1281 16 21
675 Max Mz Case 5 1457 18 26
654 Min Mz Case 6 1441 37 3
ULS DESIGN FORCES FOR Pile (R=1)

Element Load Case No. Axial (KN) Myy (KNm) Mzz (KNm)
654 Max P Case 1 1133 9 3
675 Min P Case 2 1099 2 6
QP 654 Max My Case 3 1133 9 3
675 Min My Case 4 1099 0 1
654 Max Mz Case 5 1133 9 3
654 Min Mz Case 6 1131 6 1

ULS DESIGN FORCES FOR SHEAR


Pile forces at top
Element Load Case No. Axial (tonf) Shear-y (tonf) Shear-z (tonf)
ULS
444 Max SFy 2 2.00 47.00 45.00
Design of Pile top

Diameter of shaft = 1000 mm


Clear cover to reinforcemnt = 75 mm
Grade of concrete fck = M 35
Grade of steel fyk = Fe 550 D

1st Layer 2nd Layer


Provided reinforcement = 25 dia 20 dia
+
16 No. 16 No.

i.e. = 1.64 % OK

Minimum reinforcement required = 0.4 %

Section definition in Adsec


Check for ultimate limit state

The check for ultimate limit state of shaft is carried out in adsec computer program. The snapshot of summary of strength
analysis as P-M interaction curve is shown below:-

Critical interaction ratio: 0.440 < 1 OK

Summary of strength analysis


Check for serviceability limit state (Rare combination)

The check for serviceability limit state (Rare combination) of pile is carried out in adsec computer program. The snapshot of
summary of stress check in concrete & reinforcement is shown below:-

Stress limit for concrete 0.48*fck = 16.8 Mpa


Stress limit for reinforcement = 300 Mpa

Max. stress in concrete = 3.650 Mpa OK


Max. stress in reinforcement = 56.0 Mpa OK

Summary of stresses in
concrete
Summary of stresses in
reinforcement

Check for serviceability limit state (Quasi-permanent combination)

The check for serviceability limit state (Quasi-permanent combination) of shaft is carried out in adsec computer program.

Permissible crack width wk,max = 0.3 mm


****Pile Section is Uncracked
Design of Pile 6m below Pile top.

Diameter of shaft = 1000 mm


Clear cover to reinforcemnt = 75 mm
Grade of concrete fck = M 35
Grade of steel fyk = Fe 550 D

1st Layer 2nd Layer


Provided reinforcement = 20 dia 25 dia
+
16 No. 8 No.

i.e. = 1.14 % OK

Minimum reinforcement required = 0.4 %


Cl. 709.4.4 of IRC:78
Maximum reinforcement required = 2.5 %

Section definition in Adsec


Check for ultimate limit state

The check for ultimate limit state of shaft is carried out in adsec computer program. The snapshot of summary of strength
analysis as P-M interaction curve is shown below:-

Critical interaction ratio: 0.57 < 1 OK

Summary of strength analysis


Check for serviceability limit state (Rare combination)

The check for serviceability limit state (Rare combination) of shaft is carried out in adsec computer program. The snapshot
of summary of stress check in concrete & reinforcement is shown below:-

Stress limit for concrete 0.48*fck = 16.8 Mpa


Stress limit for reinforcement = 300 Mpa

Max. stress in concrete = 3.300 Mpa OK


Max. stress in reinforcement = 53.6 Mpa OK

Summary of stresses in
concrete
Summary of stresses in
reinforcement

Check for serviceability limit state (Quasi-permanent combination)

The check for serviceability limit state (Quasi-permanent combination) of shaft is carried out in adsec computer program.

Permissible crack width wk,max = 0.3 mm


****Pile Section is Uncracked
Design of Pile 8m below Pile top.

Diameter of shaft = 1000 mm


Clear cover to reinforcemnt = 75 mm
Grade of concrete fck = M 35
Grade of steel fyk = Fe 550 D

1st Layer 2nd Layer


Provided reinforcement = 20 dia 0 dia
+
16 No. 18 No.

i.e. = 0.64 % OK

Minimum reinforcement required = 0.4 %


Cl. 709.4.4 of IRC:78
Maximum reinforcement required = 2.5 %

Section definition in Adsec


Check for ultimate limit state

The check for ultimate limit state of shaft is carried out in adsec computer program. The snapshot of summary of strength
analysis as P-M interaction curve is shown below:-

Critical interaction ratio: 0.600 < 1 OK

Summary of strength analysis


Check for serviceability limit state (Rare combination)

The check for serviceability limit state (Rare combination) of shaft is carried out in adsec computer program. The snapshot
of summary of stress check in concrete & reinforcement is shown below:-

Stress limit for concrete 0.48*fck = 16.8 Mpa


Stress limit for reinforcement = 300 Mpa

Max. stress in concrete = 3.100 Mpa OK


Max. stress in reinforcement = 51.0 Mpa OK

Summary of stresses in
concrete
Summary of stresses in
reinforcement

Check for serviceability limit state (Quasi-permanent combination)

The check for serviceability limit state (Quasi-permanent combination) of shaft is carried out in adsec computer program.

Permissible crack width wk,max = 0.3 mm


****Pile Section is Uncracked
Design of Pile 9m below Pile top.

Diameter of shaft = 1000 mm


Clear cover to reinforcemnt = 75 mm
Grade of concrete fck = M 35
Grade of steel fyk = Fe 550 D

1st Layer 2nd Layer


Provided reinforcement = 16 dia 0 dia
+
16 No. 18 No.

i.e. = 0.41 % OK

Minimum reinforcement required = 0.4 %


Cl. 709.4.4 of IRC:78
Maximum reinforcement required = 2.5 %

Section definition in Adsec


Check for ultimate limit state

The check for ultimate limit state of shaft is carried out in adsec computer program. The snapshot of summary of strength
analysis as P-M interaction curve is shown below:-

Critical interaction ratio: 0.780 < 1 OK

Summary of strength analysis


Check for serviceability limit state (Rare combination)

The check for serviceability limit state (Rare combination) of shaft is carried out in adsec computer program. The snapshot
of summary of stress check in concrete & reinforcement is shown below:-

Stress limit for concrete 0.48*fck = 16.8 Mpa


Stress limit for reinforcement = 300 Mpa

Max. stress in concrete = 2.900 Mpa OK


Max. stress in reinforcement = 48.0 Mpa OK

Summary of stresses in
concrete
Summary of stresses in
reinforcement

Check for serviceability limit state (Quasi-permanent combination)

The check for serviceability limit state (Quasi-permanent combination) of shaft is carried out in adsec computer program.

Permissible crack width wk,max = 0.3 mm


****Pile Section is Uncracked
ULS SHEAR CHECK FOR Pile SHAFT :
Design Shear Resistance ( IRC 112 / clause 10.3.2 (2) )
k = Min 1 + √ 200/d d is depth in mm
2
k = 1.5146965
T T=
1000 r1 = Min Asl /bw d
0.02
L 2
Asl = 6440.2649 mm */ Reinforcement on tension face
r1 = 0.0082 (50%)

scp = Axial stress

3/2 1/2
nmin = 0.031 k fck
L= 1000 = 0.3418882

0.33
Effective depth of section = 755.0 mm VRdc = Max ( 0.12 k (80 r1 fck ) + 0.15 scp ) bw d
fck = 35 Mpa (nmin +0.15scp ) bw d
fcd = 15.65 Mpa
fyk = 550 Mpa
Max Shear Capacity
2
Ac = 785398 mm n = 0.6 * ( 1- fck /310) */ fck in Mpa
2
As = 12881 mm = 0.5322581

VRDC, max = 0.5 bw d n fcd


Reduction factor b = 1 for av < 0.5d = 314.33688 Tonne

ULS CHECK FOR PIER SHAFT :


Forces at bottom ( SHEAR CAPACITY (LONGITUDINAL DIR n)
S.N. of pier shaft scp = Check
Description VRdc
NED HL bHL NED/AC
bHL < VRdc
Tonne Tonne Tonne 2
N/mm Tonne
1 Pile forces at top 2.0 65.1 65.1 0.0 40.5 PROVIDE SHEAR LINKS

Minimum shear reinforcement


Overall width of section = 1000 mm
Overall depth of section = 1000 mm
Effective Cover at section = 99.5 mm
Effective depth of section = 755.0 mm

Minimum shear reinforcement ratio (rmin) 0.072√fck = 0.00077


fyk
Shear reinforcement ratio (rw) ASW
(Refer clause 16.5.2 (5) of IRC :112-2011) s. bw .sina

Therefore,
2
ASW (min) /s = 774.469 mm /m

Provide 10 f links @ 150 c/c vertically

2
Asw/s provided 1047.2 mm /m OK
Design shear reinforcement (Refer clause 10.3.3.2 of IRC:112-2011)
Critical Load combination
Shear force acting on the section = 65.1 Tonne
Shear capacity of the section is = 40.5 Tonne
2
Axial Stress = 0.0 N/mm
β = 1
Reduced Shear force acting on the section VNS = 65.07 Tonne

fywd = 0.8 fywk


2
= 440 N/mm

n1 = ##### fck ≤ 80 Mpa


Max 0.9-fck/250
##### fck > 80 Mpa

n1 = 0.6

z = 0.9*deff
679.47 mm

2
scp = 0.025 N/mm

acw = 1 scp =0
= 1+ scp/fcd 0 < scp ≤ 0.25fcd
= 1.25 0.25fcd < scp ≤ 0.5fcd
= 2.5(1- scp/fcd) 0.5fcd < scp ≤ 1.0fcd

acw = 1.00163

VRd.s = Asw z fywd cot θ (Refer clause 10.3.3.2 IRC : 112-2011)


s
-1
VRd.max = acw bw z n1 fcd q =0.5 sin [ 2*VNS/(acw * bw * z * v1 * fcd)]
(cotθ + tanθ)

-1
q = 0.5 sin [ 2*VNS / (acw * bw * z * n1 * fcd) ]
= 5.88 ◦ OK

q, Adopted = 21.8 ◦
Asw/s = VNS/z fywd cot θ
2
= 870.526 mm /m

Provide 10 f links @ 150 c/c vertically

2
Asw/s provided 1047.2 mm /m OK