You are on page 1of 2

Page 4/4 unios.com Page 1/4 unios.

com

EQ
Minimum clearance for luminaire
Risk of Fire – Required clearance from structure members and building elements. Details below: DOWNLIGHT SERIES

Barrier required for loose fill insulation Please ensure the driver is Base Essential Comfort Tilt Power
or loose combustible materials fixed above any insulation
IC-4 Codes EQED0105 EQCD0100 EQTD0104 10 Watts

Building Element Above Fitting Class III IP Rating Material Install Person/s
Luminaire only 44 Aluminium 1x

0
CAUTION – This product must be installed by a qualified installer
Transformer
Building Please read instruction manual carefully before installing luminaire
0
Structural
Thermal 0
Member
IC-4 Luminaire Insulation Surge Protection
Tested to and in Recessed Ceiling For comprehensive protection of a luminaire against electrical surges, surge protection shall be installed
accordance with Luminaire
on the mains supply where required to protect luminaires and drivers from transient voltage damage.
AS/NZS 60598.2.2:2016
All measurements are based in millimetres.
For warranty information visit unios.com/warranty
Cleaning Corrosion Protection Please read these installation instructions carefully before installing this luminaire. This product must be installed and
maintained by a suitably qualified person/s in compliance with the latest applicable regulations and relevant legislation.
Warning: Before cleaning, disconnect from It is important to note that care must be taken Unios does not warrant any claim based on defects or damage caused by misuse, improper installation, improper
mains supply and allow luminaire to cool. operation and/or modifications carried out by the purchaser or third parties. This luminaire will not be used as a
during installation or maintenance to ensure that
'Working light' during construction. This will result in the warranty of the luminaire to be void. For warranty duration,
the surface of the luminaire is not damaged. Any please refer to the data sheet.
1 2
damage, which is exposed to moisture will result
in corrosion occurring.
Product Variations
Please also note that any chemical applications on
the luminaire or chemical contact via installation will
cause corrosion of the surface of the luminaire and will
void the warranty.
C
Disposal Ambient Conditions
EQED0105 EQCD0100 EQTD0104
Ensure correct disposal of this Recommended to install in an
product (waste electrical and ambient temperature <35°C.
electronic equipment) Product Code A B C
EQED0105 105 56 92
EQCD0100 100 85 92
EQTD0104 104 63 95
All measurements are in millimetres.
B

Edition 18.3.22 | Product design and technical data may be subject to change Edition 18.3.22 | Product design and technical data may be subject to change
Page 2/4 Page 3/4 unios.com

Wiring

N
ON DRIVER
L
OFF
AC

Power Source

3 240V
LED
SELV

SELV

1 240V 240V

2 5
Dimming
This luminaire can be dimmed. Unios® recommends a
phase-cut dimmer or DALI solution optimised for
LED technology.
EQTD0104
Adjustability: 20° For full list of compatible drivers, see unios.com

Edition 18.3.22 | Product design and technical data may be subject to change

You might also like