You are on page 1of 4

AIR PREHEATER PERFORMAN

AIR HEATER AIR HEATER INLET O2%-AIR HEATER OUTLET O2%


X90%
LEAKAGE= AIR HEATER OUTLET O2%-O2% IN ATMOSPHERE

4.3 MINUS 4.26


꓿ MINUS
X90%
4.26 20.90
0.04
꓿ X90%
-16.64
AIR HEATER LEAKAGE 0 -0.22 %
ENTER THE DATA :-
AIR HEATER INLET O2% 4.3
AIR HEATER OUTLET O2% 4.26
O2% IN ATMOSPHERE 20.90 FIXED

AIR HEATER X- GAS INLET TEMPERATURE-GAS OUTLET TEMPERATURE


RATIO= AIR OUTLET TEMPERATURE-AIR INLET TEMPERATURE

633 MINUS 345


꓿ MINUS
560 70
288

490
AIR HEATER X-RATIO ꓿ 0.59
ENTER THE DATA :-
GAS INLET TEMPERATURE 633 F
GAS OUTLET TEMPERATURE 345 F
AIR OUTLET TEMPERATURE 560 F
AIR INLET TEMPERATURE 70 F
ATER PERFORMANCE ANALYSIS
GAS SIDE GAS INLET TEMPERATURE-GAS OUTLET TEMPERATURE
EFFICIENCY GAS INLET TEMPERATURE-AIR INLET TEMPERATURE

633 MINUS 345


꓿ 633 MINUS
X100%
70
288
꓿ X100%
563
GAS SIDE EFFICIENCY ꓿ 51.15 %
ENTER THE DATA :-
GAS INLET TEMPERATURE 633 F
GAS OUTLET TEMPERATURE 345 F
AIR INLET TEMPERATURE 70 F

AIR SIDE AIR OUTLET TEMPERATURE- AIR INLET TEMPERATURE


EFFICIENCY GAS INLET TEMPERATURE- AIR INLET TEMPERATURE

220 MINUS 70
꓿ 350 MINUS
X100%
70
150
꓿ X100%
280
AIR SIDE EFFICIENCY ꓿ 53.57 %
ENTER THE DATA :-
AIR OUTLET TEMPERATURE 220 F
AIR INLET TEMPERATURE 70 F
GAS INLET TEMPERATURE 350 F
ECONOMISER PERFORMANCE ANALYSIS

ECONOMISER O/L FEED WATER TEMP-ECONOMISER I/L FEED WATER TEMP


ECONOMISER EFFICIENCY (ⴄ)=
ECONOMISER I/L FLUE GAS TEMP-ECONOMISER I/L FEED WATER TEMP

0.38 x 100
ECONOMISER EFFICIENCY (ⴄ) 38.46 %

ENTER THE DATA :-


ECONOMISER O/L FEED WATER TEMP 255
ECONOMISER I/L FEED WATER TEMP 180
ECONOMISER I/L FLUE GAS TEMP 375