You are on page 1of 1

1 2 3 4 5 6 7

NOTES : CLIENT :

CONCRETE:

REINFORCEMENT STEEL:
A B C D
PROJECT MANAGEMENT & COST CONSULTANCY :
1495

555 385 555


A A

5.400
UPPER ROOF TERRACE PLAN
10 10

5
10 10

100

100
95

95
4.40 r
20 20 4.400 CONSULTANT DESIGN REVIEWER :
ROOF TERRACE PLAN

20

20
60
B13a B14 B12a B15 B11a B16 B10a GEOTECH :
30x60ht 30x60ht 30x60ht 30x60ht 30x60ht 30x60ht 30x60ht
IL=3.80 IL=3.80 IL=3.80 IL=3.80 IL=3.80 IL=3.80 IL=3.80

C13 C14 C15 C16

440
420
D30 D30 D30 D30 REFERENCE:

426
DESIGNER :

380
25 530 385 530 25

30 410 20 205
-0.06 r 150 25 40
Rock
-0.10 r Compacted back filling
0.000
Compacted back filling GROUND FLOOR PLAN
10

10

16

25 15 39 16

1121
20
-0.70 r -0.70 r
60

54
Refill
CONTRACTOR :
20

B5 B4 B3 B2
50x100ht 40x100ht 40x100ht 50x100ht

150
IL=-1.06 IL=-1.06 IL=-1.06 IL=-1.06

125
B -2.20 r B
MODERN ARCH

25

5 25
C3 C7 C8 C4
50x50ht 40x50ht 40x50ht 50x50ht

566
556

W1.12 W1.17 W1.06


491

SUBCONTRACTOR :

10 20 20 20 20
MEP 15

321
Plain concrete
50
50 495 40 345 40 495 Rocks
30 635 1490 25 175 30
-5.81 r 15 10
15 150 15 Polystyrene
Screed -5.660
Screed
-6.06 r BASEMENT FLOOR PLAN

30 10
30 25 15

15
-5.810
30 25

BFP-0.15 LEGEND :
5
Concrete cut
5

Concrete projection

150
25 150 25 158

175
-7.56 r Concrete hidden
W0.01 5 W0.03 Masonry wall
Rocks
5 25 Refill, Screed
Polystyrene
LEVEL ± 0.00 = +635.60 NGSA
Rock
SECTION A-A
SCALE : 1 : 50
S: ISOLATED FOUNDATION

C SF: STRIP FOUNDATION C


C: COLUMN
A B C D
W: WALL
1495
OP: OPENING IDENTIFICATION
555 385 555 B: BEAM
EB: EMBEDDED BEAM
UL: UPPER LEVEL 04 UPDATE 04/06/2022
5.400 03 CONCRETE FILL HATCH 08/05/2022
UPPER ROOF TERRACE PLAN IL: INFERIOR LEVEL
10 10
5

5
10 10 02
UPDATED AS PER DAR'S COMMENT
25/11/2021
UPDATED AS PER DAR'S COMMENT

100
B 01 04/11/2021
95

95
4.40 r
20 20 4.400 00
FIRST ISSUE
28/10/2021
ROOF TERRACE PLAN
20

20
REV. DESCRIPTION DATE
3.70 r 25 NO.
5 30 47 50 35 40
50
20

B13b B10b
30x60ht B12b B11b 30x60ht 25 5 30 15
IL=3.50 30x60ht 30x60ht IL=3.80
IL=3.80 IL=3.80 0.000
GROUND FLOOR PLAN

16
W2.03 W2.02

440
10 10

436

70
10 10

54
366

15 15 15 15 15 15 20 -0.660

20 300 210 180 180 150 180 185


ISSUED FOR CONSTRUCTION

25
Rock Polystyrene
Compacted back filling
0.000
Compacted back filling Screed
10

GROUND FLOOR PLAN


D D

1121
30

150
20 30

30

40 20 30

120
5011 3 020 011B 100 D_00
B6 PROJECT CODE PHASE TRADE BUILDING DOC. NUMBER REVISION

B9 B8 B7
50x60ht
40x60ht IL=-1.06 CIVIL/LS ARCHITECT STRUCTURAL
50x60ht IL=-1.06 40x60ht -2.200
IL=-1.06 IL=-1.06
- - -

30
5
ELECTRICAL MECHANICAL ICT
20
SF1
30

566
60x202x30ht
- - -
610 565
BL=-2.45
510

DRAWN BY CHECKED BY APPROVED BY


460

W1.20
TTC VHT RS

SECTION L-L SITE KEY PLAN : PROJECT TITLE :

SCALE : 1 : 25
Polystyrene K88_PROJECT
10

Screed -5.660
10

BASEMENT FLOOR PLAN N

15
-5.810 BUILDING NUMBER & NAME :
30

30

BFP-0.15
011B
40

POOL HOUSE
BUILDING KEY PLAN : DRAWING TITLE :

E BUILDING 11B E
SECTION AND DETAILS (1/2)
SECTION K-K FORMWORKS
SCALE : 1 : 50

SCALE - SHEET SIZE DATE CAD FILE

1/50 - A0+ 28/10/2021 K88-P3-011B-05-DWG-STC-020-0100-04

DOCUMENT NUMBER :

K88 P3 011B 05 DWG STC 020 0100 04


PROJECT PROGRAM BUILDING PHASE DOC. TYPE DISCIPLINE TRADE DOC. NUMBER REVISION

1 2 3 4 5 6 7

You might also like