Professional Documents
Culture Documents
net/publication/267970142
Article
CITATIONS READS
2 617
5 authors, including:
All content following this page was uploaded by Sonia Degeratu on 13 January 2015.
Abstract The paper present a simultaneous force and Shape memory actuators are considered to be low
length variation mode shape memory alloy (SMA) power actuators and such as compete with solenoids,
robotic application. The robotic ankle contains 4 SMA bimetals and to some degree was motors. It is
actuators and a spherical articulation. In order to estimated that shape memory springs can provide
assure a high efficient robotic architecture, the
over 100 times the work output of thermal bimetals.
mechanical and the control structure have to assure a
real-time response to the work environment changes.
The use of shape memory alloy can sometimes
The load variations or the difference between the simplify a mechanism or device, reducing the overall
moment of full contact step and the non contact number of parts, increasing reliability and therefore
moment for a waking robot are the standard situations reducing associated quality costs.
for a SMA robotic ankle. The paper is divided in three Because of its high rezistivity of 80 – 89 micro ohm-
sections. First section makes a short introduction in the cm, nickel titanium can be self heated by passing an
physical description and conventional applications of electrical current through it. The basic rule for
shape memory alloy materials. In the second part are electrical actuation is that the temperature of
presented mathematical model for robotic ankle. In the
complete transformation to martensite Mf , of the
last section, the conventional control structures applied
to the robotic ankle are explored. An experimental
actuator, must be well above the maximum ambient
platform was developed and real responses of the temperature expected [6].
structure to the disturbances are explored. Using
Matlab/Symulink and a modified Quanser platform the 2. APPLICATIONS OF SHAPE MEMORY
experimental results are investigate, in order to ALLOY MATERIAL IN ROBOTICS
highlight the advantages and disadvantages of each
conventional controller. As the alloys and manufacturing techniques
improved, the experience and results of
Keywords: robotics, shape memory alloy applications,
experimenters are focused developing new SMA
robotic ankle, conventional control.
industrial applications.
Nitinol received much attention for medical
1. INTRODUCTION applications, toys industry, teleoperated systems and
robotics, especially autonomous robots. In 1989
The shape memory effect was first noted over 50 Oaktree Automation Inc, in Alexandria Virginia,
years ago; it was not until 1962, however, with the started developing the Fingerspelling Hand, an
discovery of a nickel titanium shape memory alloy anthropomorphic robotic device to serve as a tactile
but Buehler, that serious investigations were communication aid for deaf - blind individuals,
undertaken to understand the mechanism of the shape particularly those unable to read Braille. The device
memory effect [5,7,8,9]. The shape memory alloys
used a total of one hundred and eight 250 µm
possess the ability to undergo shape change at low
Flexinol wires acting in parallel.
temperature and retain this deformation until they are
The most successful applications of shape memory
heated, at which point they return to their original
alloy components usually have all or most of the
shape. The nickel titanium alloys, used in the present
following characteristics [10]:
research, generally refereed to as Nitinol, have
- A mechanically simple design
compositions of approximately 50 atomic % Ni/ 50
- The shape memory component pops in place and is
atomic % Ti, with small additions of copper, iron, held by other parts in the assembly
cobalt or chromium. The alloys are four times the
- The shape memory alloy component is in direct
cost of Cu-Zn-Al alloys, but it possesses several
contact with a heating/cooling medium
advantages as greater ductility, more recoverable
- Friction is minimized and no complex stresses or
motion, excellent corrosion resistance, stable
stress concentrations are present
transformation temperatures, high biocompatibility
- A minimum force and motion requirement for the
and the ability to be electrically heated for shape shape memory component
recovery.
208
- The shape memory component is isolated from
incidental forces with high variation
- The tolerances of all the components realistically
interface with the shape memory component.
Connectors
Figure 2: Human ankle Figure 3: Wilko ankle training Figure 4: High efficient ankle
structure. machine. Yanbo robot.
The problem in developing efficient ankle structure, The proposed robot ankle structure contains units
concern the dimension and the efficiency of with SMA actuators. The unit has 4 SMA actuators
actuators. and a spherical articulation.
H ankle ( 1, )
2 , lc =
sin 1 sin 2
cos 1 sin 2
cos 1
sin 1
sin 1 cos 2
cos 1 cos 2
l c sin 1 cos 2
l c cos 1 cos 2
(1)
0 0 0 1
209
Analyzing the angle dependence versus the SMA In order to control an ankle robot are used
spring variation, a highly nonlinear function results: techniques which impose a two level control
hierarchical structure: the task strategy and the
2 2
individual unit control strategy.
2 lb + l c
( ( ))
= arcsin cos arctg l h ( )
+ arctg l h (2) The present paper deal with the low level real control
for a SMA single unit, in order to verify the response
2lb
of the SMA actuator to different input reference or
lh – the length after the heating process, lc – the high stress disturbance. In order to investigate the
spring length after cooling, lb - the base length. As SMA unit comportment a Quanser modified platform
the real variation is restricted (between 100% and 92 was used for experiments. The basic control structure
%), the linearization can occur because of linear uses a configurable PID controller and a Quanser
behaviour for the specified evolution [1]. Power Module Unit for energizing the SMA
actuators.
211
One can observe the high dynamics of the control 5. CONCLUSIONS
variable. The time response is longer then the case of
PI controller, but the stationary error is less then the The study and the experiments concerning the SMA
anterior case. robotic applications are one of the actual projects of
the Unconventional Control architecture laboratory
4.3. Control of a single SMA unit using a PID [2, 3, and 4].
regulator The SMA ankle structure represents an interesting
solution for painter robots or robots designated to
The PD experimented controller parameters are: the work in hazardous space.
proportional parameter KR = 10 and the integration The actual experiments explore the simple control for
component is KI =0,005 and the derivative a single SMA unit in case of input variation, and in
component is KD=2. The experimental results are case of load variation. The response developed by the
illustrated in the figure, and the control signal system in case of PI controller has superior
variation is presented in Figure 14 and 15. parameters comparative with the PD and PID
Unfortunately, even with the complication of the controller.
controller, the time response is inferior to the case of
the PI controller and the stationary error is near zero.
References
212