You are on page 1of 4

CAESAR II Ver.5.10.

03, (Build 090206) Date:NOV 6,2009 Time:14:58 Page: 1


Job´s: E-45201A.661; E-45201B.661; E-45202A.661; E-45202A.661
Licensed To: TECHINT ID 12594

CAESAR II ANALYSIS REPORT: API 661 2006 - Air Cooled Exchangers (6th Ed.)

Description:
E-45201 NGL MINIMUM FLOW COOLER
N1-N3

Suction Nozzle Node Number = 825


Discharge Nozzle Node Number = 730

Suction Nozzle Nominal Diameter = 6.0 in. (150.0)


Discharge Nozzle Nominal Diameter = 6.0 in. (150.0)

User Entered Table 4 Allowable = 3.00


User Entered For/Mom. Allowable = 2.00
Tube Bundle Direction = X

Units For This Analysis = in. , N. , N.m. , mm.

Suction Figure 6 Force & Moment Status


Values Ratios
Y Distance 600.0

X Force = 163.0 4003. 0.04 PASSED


Y Force = -2747.0 5026. -0.55 PASSED
Z Force = -7974.0 5026. -1.59 PASSED

X Moment = -2135.0 2142. -1.00 PASSED


Y Moment = 184.0 3050. 0.06 PASSED
Z Moment = 710.0 1627. 0.44 PASSED

Discharge Figure 6 Force & Moment Status


Values Ratios
Y Distance 600.0

X Force = 1053.0 4003. 0.26 PASSED


Y Force = -1868.0 5026. -0.37 PASSED
Z Force = -4406.0 5026. -0.88 PASSED

X Moment = 1550.0 2142. 0.72 PASSED


Y Moment = -97.0 3050. -0.03 PASSED
Z Moment = 1087.0 1627. 0.67 PASSED

Resultant Force/Moment Check :

Resultant Table Allowable Ratios Status

X Force = 1216.0 10008. 0.12 PASSED


Y Force = -4615.0 20016. 0.23 PASSED
Z Force = -12380.0 16680. 0.74 PASSED

X Moment = -2725.8 6101. 0.45 PASSED


Y Moment = 87.0 8135. 0.01 PASSED
Z Moment = 2331.0 4067. 0.57 PASSED

Overall Loading Status Passed.


CAESAR II Ver.5.10.03, (Build 090206) Date:NOV 6,2009 Time:14:58 Page: 2
Job´s: E-45201A.661; E-45201B.661; E-45202A.661; E-45202A.661
Licensed To: TECHINT ID 12594

CAESAR II ANALYSIS REPORT: API 661 2006 - Air Cooled Exchangers (6th Ed.)

Description:
E-45201 NGL MINIMUM FLOW COOLER
N2-N4

Suction Nozzle Node Number = 855


Discharge Nozzle Node Number = 760

Suction Nozzle Nominal Diameter = 6.0 in. (150.0)


Discharge Nozzle Nominal Diameter = 6.0 in. (150.0)

User Entered Table 4 Allowable = 3.00


User Entered For/Mom. Allowable = 2.00
Tube Bundle Direction = X

Units For This Analysis = in. , N. , N.m. , mm.

Suction Figure 6 Force & Moment Status


Values Ratios
Y Distance 600.0

X Force = -561.0 4003. -0.14 PASSED


Y Force = -3153.0 5026. -0.63 PASSED
Z Force = 6991.0 5026. 1.39 PASSED

X Moment = 1799.0 2142. 0.84 PASSED


Y Moment = -89.0 3050. -0.03 PASSED
Z Moment = 924.0 1627. 0.57 PASSED

Discharge Figure 6 Force & Moment Status


Values Ratios
Y Distance 600.0

X Force = -2046.0 4003. -0.51 PASSED


Y Force = -2252.0 5026. -0.45 PASSED
Z Force = 209.0 5026. 0.04 PASSED

X Moment = -346.0 2142. -0.16 PASSED


Y Moment = 510.0 3050. 0.17 PASSED
Z Moment = 179.0 1627. 0.11 PASSED

Resultant Force/Moment Check :

Resultant Table Allowable Ratios Status

X Force = -2607.0 10008. 0.26 PASSED


Y Force = -5405.0 20016. 0.27 PASSED
Z Force = 7200.0 16680. 0.43 PASSED

X Moment = 5522.2 6101. 0.91 PASSED


Y Moment = 421.0 8135. 0.05 PASSED
Z Moment = 212.0 4067. 0.05 PASSED

Overall Loading Status Passed.


CAESAR II Ver.5.10.03, (Build 090206) Date:NOV 6,2009 Time:14:58 Page: 3
Job´s: E-45201A.661; E-45201B.661; E-45202A.661; E-45202A.661
Licensed To: TECHINT ID 12594

CAESAR II ANALYSIS REPORT: API 661 2006 - Air Cooled Exchangers (6th Ed.)

Description:
E-45202 NGL MINIMUM FLOW COOLER
N1-N3

Suction Nozzle Node Number = 955


Discharge Nozzle Node Number = 860

Suction Nozzle Nominal Diameter = 6.0 in. (150.0)


Discharge Nozzle Nominal Diameter = 6.0 in. (150.0)

User Entered Table 4 Allowable = 3.00


User Entered For/Mom. Allowable = 2.00
Tube Bundle Direction = X

Units For This Analysis = in. , N. , N.m. , mm.

Suction Figure 6 Force & Moment Status


Values Ratios
Y Distance 600.0

X Force = -3780.0 4003. -0.94 PASSED


Y Force = -3897.0 5026. -0.78 PASSED
Z Force = -1116.0 5026. -0.22 PASSED

X Moment = 1.0 2142. 0.00 PASSED


Y Moment = -402.0 3050. -0.13 PASSED
Z Moment = 1543.0 1627. 0.95 PASSED

Discharge Figure 6 Force & Moment Status


Values Ratios
Y Distance 600.0

X Force = -3341.0 4003. -0.83 PASSED


Y Force = -3154.0 5026. -0.63 PASSED
Z Force = 3689.0 5026. 0.73 PASSED

X Moment = -687.0 2142. -0.32 PASSED


Y Moment = -650.0 3050. -0.21 PASSED
Z Moment = -44.0 1627. -0.03 PASSED

Resultant Force/Moment Check :

Resultant Table Allowable Ratios Status

X Force = -7121.0 10008. 0.71 PASSED


Y Force = -7051.0 20016. 0.35 PASSED
Z Force = 2573.0 16680. 0.15 PASSED

X Moment = -3569.0 6101. 0.58 PASSED


Y Moment = -1052.0 8135. 0.13 PASSED
Z Moment = 1762.4 4067. 0.43 PASSED

Overall Loading Status Passed.


CAESAR II Ver.5.10.03, (Build 090206) Date:NOV 6,2009 Time:14:58 Page: 4
Job´s: E-45201A.661; E-45201B.661; E-45202A.661; E-45202A.661
Licensed To: TECHINT ID 12594

CAESAR II ANALYSIS REPORT: API 661 2006 - Air Cooled Exchangers (6th Ed.)

Description:
E-45202 NGL MINIMUM FLOW COOLER
N2-N4

Suction Nozzle Node Number = 925


Discharge Nozzle Node Number = 930

Suction Nozzle Nominal Diameter = 6.0 in. (150.0)


Discharge Nozzle Nominal Diameter = 6.0 in. (150.0)

User Entered Table 4 Allowable = 3.00


User Entered For/Mom. Allowable = 2.00
Tube Bundle Direction = X

Units For This Analysis = in. , N. , N.m. , mm.

Suction Figure 6 Force & Moment Status


Values Ratios
Y Distance 600.0

X Force = 3620.0 4003. 0.90 PASSED


Y Force = -779.0 5026. -0.15 PASSED
Z Force = 12184.0 5026. 2.42 PASSED

X Moment = 3625.0 2142. 1.69 PASSED


Y Moment = -571.0 3050. -0.19 PASSED
Z Moment = -640.0 1627. -0.39 PASSED

Discharge Figure 6 Force & Moment Status


Values Ratios
Y Distance 600.0

X Force = 62.0 4003. 0.02 PASSED


Y Force = 4575.0 5026. 0.91 PASSED
Z Force = -3400.0 5026. -0.68 PASSED

X Moment = -5446.0 2142. -2.54 PASSED


Y Moment = 282.0 3050. 0.09 PASSED
Z Moment = -221.0 1627. -0.14 PASSED

Resultant Force/Moment Check :

Resultant Table Allowable Ratios Status

X Force = 3682.0 10008. 0.37 PASSED


Y Force = 3796.0 20016. 0.19 PASSED
Z Force = 8784.0 16680. 0.53 PASSED

X Moment = 7529.4 6101. 1.23 PASSED


Y Moment = -289.0 8135. 0.04 PASSED
Z Moment = -2995.8 4067. 0.74 PASSED

Overall Loading Status Passed.