1 SITC of Variable Refrigerant Type System

SITC of coated fins, panel, corrosion resistant


coated condenser, inverter based condenser fan,
M.S. hot dip galvanised stands / supports,
1.1 electrical & microprocessor panel, isolating
valves, etc. AS REQUIRED. THE UNIT CAPACITY
DEFINED BELOW SHALL BE AT AMBIENT
TEMPERATURE OF 42 ºC

a 14 HP VRV (TOP DISCHARGE) CIRCUIT - 01 each 2 200392 400784 12375 24750 226369 452738 8500 17000

b 20 HP VRV (TOP DISCHARGE) CIRCUIT - 02 each 1 274222 274222 12375 12375 294962 294962 14500 14500

c 20 HP VRV (TOP DISCHARGE) CIRCUIT - 03 each 1 274222 274222 12375 12375 294962 294962 14500 14500

d 20 HP VRV (TOP DISCHARGE) CIRCUIT - 05 each 2 274222 548444 12375 24750 294962 589924 14500 29000

e 14 HP VRV (TOP DISCHARGE) CIRCUIT - 08 each 2 200392 400784 12375 24750 226369 452738 8500 17000

f 16 HP VRV (TOP DISCHARGE) CIRCUIT - 09 each 1 227382 227382 12375 12375 250446 250446 10500 10500

g 16 HP VRV (TOP DISCHARGE) CIRCUIT - 10 each 2 227382 454764 12375 24750 250446 500892 10500 21000

h 20 HP VRV (TOP DISCHARGE) CIRCUIT - 11 each 1 274222 274222 12375 12375 294962 294962 14500 14500

i 14 HP VRV (TOP DISCHARGE) CIRCUIT - 12 each 1 200392 200392 12375 12375 226369 226369 8500 8500

j 14 HP VRV (TOP DISCHARGE) CIRCUIT - 13 each 2 200392 400784 12375 24750 226369 452738 8500 17000

k 20 HP VRV (TOP DISCHARGE) CIRCUIT - 14 each 1 274222 274222 12375 12375 294962 294962 14500 14500

l 20 HP VRV (TOP DISCHARGE) CIRCUIT - 15 each 1 274222 274222 12375 12375 294962 294962 14500 14500
Daikin Carrier
supply INSTALLATION supply INSTALLATION
SR. UNIT TOTAL UNIT TOTAL
NO. DESCRIPTION OF ITEMS UoM QTY
RATE
TOTAL RATE UNIT RATE RATE RATE
TOTAL RATE UNIT RATE
RATE

m 12 HP VRV (TOP DISCHARGE) CIRCUIT - 16 each 1 176948 176948 12375 12375 188546 188546 6500 6500

0 0

SITC OF WALL MOUNTED Hi-WALL UNITS (Noise


Level to be <40 Db at Medium Speed in the 0 0
Room).

a 0.60 TR each 2 13889 27778 1237.5 2475 16621 33242 600 1200
b 1.00 TR each 3 14480 43440 1237.5 3712.5 17527 52581 600 1800
b 1.60 TR each 2 16303 32606 1237.5 2475 18432 36864 600 1200
c 2.00 TR each 38 16992 645696 1237.5 47025 22245 845310 600 22800
0 0 0
SITC OF CEILING SUSPENDED 4 WAY CASSATTE
1.2 UNITS (Noise Level to be <40 Db at Medium 0 0
Speed in the Room).
a 1.00 TR each 3 23887 71661 1856.25 5568.75 25616 76848 900 2700
b 1.28 TR each 1 25808 25808 1856.25 1856.25 26617 26617 900 900
c 1.60 TR each 4 26744 106976 1856.25 7425 26791 107164 900 3600
d 2.00 TR each 12 27483 329796 1856.25 22275 27696 332352 900 10800
d 2.26 TR each 1 30931 30931 1856.25 1856.25 28428 28428 900 900
e 2.56 TR each 24 30931 742344 1856.25 44550 29430 706320 900 21600
f 3.18 TR each 4 31620 126480 1856.25 7425 31066 124264 900 3600
g 4.00 TR each 4 32359 129436 1856.25 7425 31972 127888 900 3600
0 0
CEILING SUSPENDED DUCTABLE HIGH STATIC
UNITS (Noise Level to be <45 Db at Medium
1.3 Speed in the 0 0
Room).
a 6.36 TR each 2 61861 123722 3712.5 7425 63231 126462 1800 3600
b 8.00 TR each 2 65506 131012 3712.5 7425 66582 133164 1800 3600
0 0
1.4 Remote Control with receiver 0 0
a Corded remote controllers each 4 1724 6896 866.25 3465 2600 10400 1500 6000
b Cordless remote controllers each 98 2950 289100 0 0 3000 294000 150 14700
0 0
Daikin Carrier
supply INSTALLATION supply INSTALLATION
SR. UNIT TOTAL UNIT TOTAL
NO. DESCRIPTION OF ITEMS UoM QTY
RATE
TOTAL RATE UNIT RATE RATE RATE
TOTAL RATE UNIT RATE
RATE

Computer controlled network system for


monitoring & controlling all indoor & outdoor
units with required control cabling between all
indoor and outdoor units, central point including
all software & cabling. Controller shall be with
open protocol for soft integration with Building
automation system(BAS). Necessary software
1.4 shall be provided to ON/OFF/control VRF indoor each 1 171054 171054 44550 44550 80000 80000 6000 6000
and outdoor units through BAS for all Units.
CONTRACTOR TO STUDY TENDER DRAWING
PRIOR TO QUOTE FOR LENGTH OF CONTROL
CABLING FROM THE CONTROLLER TO BE
MOUNTED AT RECEPTION AREA. SUITABLE PC IF
REQUIRED, SHALL BE PROVIDED BY THE
PURCHASER

0 0
Supply & Installation of the following
1.5 components of VRV system: 0 0

REFRIGERANT PIPING & CONTROL CABLING 0 0


Daikin Carrier
supply INSTALLATION supply INSTALLATION
SR. UNIT TOTAL UNIT TOTAL
NO. DESCRIPTION OF ITEMS UoM QTY
RATE
TOTAL RATE UNIT RATE RATE RATE
TOTAL RATE UNIT RATE
RATE

All required refrigerant piping & power/control


cable from indoor to outdoor units as per OEM
requirement with REFRIGERANT JOINTS, Hard
Copper refrigerant piping between indoor &
outdoor units (Single Distance to be considered))
of neatly brazed & should pass thru in sleeves
provide in columns / beams. Refrigerant piping
and cabling running at terrace level & Inside the
1.6 air-conditioing area shall be on the perforated 0 0
heavy duty cable tray and duly epoxy coated
Black painted clamps . Refrigerant pipes shall be
insulated with 13mm Thick Closed Cell
Elastomeric Tube Insulation covered with 7mil
glass cloth of fire retardant quality and painted
with anti UV paint and final coat of Anti rodant
repelent as per specifications.

a 14 HP VRV (TOP DISCHARGE) CIRCUIT - 01 RMT 80 1621.62 129729.6 470.25 37620 950 76000 365 29200

b 20 HP VRV (TOP DISCHARGE) CIRCUIT - 02 RMT 55 1752.3 96376.5 470.25 25863.75 1050 57750 365 20075

c 20 HP VRV (TOP DISCHARGE) CIRCUIT - 03 RMT 40 1752.3 70092 470.25 18810 1050 42000 365 14600

d 20 HP VRV (TOP DISCHARGE) CIRCUIT - 05 RMT 130 1752.3 227799 470.25 61132.5 1050 136500 365 47450

e 14 HP VRV (TOP DISCHARGE) CIRCUIT - 08 RMT 95 1621.62 154053.9 470.25 44673.75 950 90250 365 34675

f 16 HP VRV (TOP DISCHARGE) CIRCUIT - 09 RMT 75 1686.96 126522 470.25 35268.75 950 71250 365 27375

g 16 HP VRV (TOP DISCHARGE) CIRCUIT - 10 RMT 115 1686.96 194000.4 470.25 54078.75 950 109250 365 41975

h 20 HP VRV (TOP DISCHARGE) CIRCUIT - 11 RMT 95 1752.3 166468.5 470.25 44673.75 1050 99750 365 34675
Daikin Carrier
supply INSTALLATION supply INSTALLATION
SR. UNIT TOTAL UNIT TOTAL
NO. DESCRIPTION OF ITEMS UoM QTY
RATE
TOTAL RATE UNIT RATE RATE RATE
TOTAL RATE UNIT RATE
RATE

i 14 HP VRV (TOP DISCHARGE) CIRCUIT - 12 RMT 70 1621.62 113513.4 470.25 32917.5 950 66500 365 25550

j 14 HP VRV (TOP DISCHARGE) CIRCUIT - 13 RMT 120 1621.62 194594.4 470.25 56430 950 114000 365 43800

k 20 HP VRV (TOP DISCHARGE) CIRCUIT - 14 RMT 115 1752.3 201514.5 470.25 54078.75 1050 120750 365 41975

l 20 HP VRV (TOP DISCHARGE) CIRCUIT - 15 RMT 110 1752.3 192753 470.25 51727.5 1050 115500 365 40150

m 12 HP VRV (TOP DISCHARGE) CIRCUIT - 16 RMT 90 1489.95 134095.5 470.25 42322.5 850 76500 365 32850

SITC of Coomunication cable of VRF unit 0.75 RMT 850 0 0 0 0 140 119000 55 46750
SQMM 3 core sheilded cable with conduite

Providing and erecting approved make split air-


conditioning unit consisting of copper
condensing unit with fan motor, hermetically
sealed rotary compressor with accessories etc.
duly connected separately erected evaporating
unit and blower motor with its accessories by
a means of extra supplied proper insulated copper 2 31728.51 63457.02 1361.25 2722.5 38500 77000 3500 7000
tubing,drain PVC pipes suitable for ( cost
includes powder coated Stand, Eco Friendly
green gas charging, 15A plug top & Remote
Control) with necessary core cutting.
1. 1.56TR CAPACITY

Copper Pipes - 15feet With proepr insulation 5 850 4250 300 1500
Daikin Carrier
supply INSTALLATION supply INSTALLATION
SR. UNIT TOTAL UNIT TOTAL
NO. DESCRIPTION OF ITEMS UoM QTY
RATE
TOTAL RATE UNIT RATE RATE RATE
TOTAL RATE UNIT RATE
RATE

Providing and erecting approved make split air-


conditioning unit consisting of copper
condensing unit with fan motor, hermetically
sealed rotary compressor with accessories etc.
duly connected separately erected evaporating
unit and blower motor with its accessories by
b means of extra supplied proper insulated copper 2 50454.36 100908.72 1361.25 2722.5 45500 91000 15500 31000
tubing,drain PVC pipes suitable for ( cost
includes powder coated Stand, Eco Friendly
green gas charging, 15A plug top & Remote
Control) with necessary core cutting.
1. 2.56TR CAPACITY

Copper Pipes - 15feet With proepr insulation 5 850 4250 300 1500

Providing and erecting approved make Cassette


type split air-conditioning unit consisting of
condensing unit with fan motor, hermetically
sealed scroll/rotary compressor with accessories
etc. duly connected separately erected
c evaporating unit and blower motor with its 1 57097.26 57097.26 3217.5 3217.5 55500 55500 15500 15500
accessories by Eco friendly Green gas charging &
Internal copper wiring & Remote control ( 3 star
and above of current year) with necessary core
cutting.
1. 4TR CAPACITY-3 PH

Copper Pipes - 15feet With proepr insulation 5 850 4250 300 1500

M.S. Stand for installing VRV outdoor units duly


3 epoxy coated Black paint Kgs 3600 94.05 338580 24.75 89100 125 450000 35 126000
Daikin Carrier
supply INSTALLATION supply INSTALLATION
SR. UNIT TOTAL UNIT TOTAL
NO. DESCRIPTION OF ITEMS UoM QTY
RATE
TOTAL RATE UNIT RATE RATE RATE
TOTAL RATE UNIT RATE
RATE

PVC Drain piping for the units with 9mm Thick


Closed Cell Elastomeric Tube Insulation covered
with 7mil glass cloth of fire retardant quality and
3.1 painted with anti UV paint and final coat of Anti 0 0 0 0 0
rodant
repelent as per specifications.

a 25 mm RMT 495 83.16 41164.2 49.5 24502.5 95 47025 25 12375


b 32 mm RMT 130 94.05 12226.5 49.5 6435 105 13650 30 3900
c 40 mm RMT 76 107.91 8201.16 49.5 3762 135 10260 35 2660
d 50 mm RMT 20 120.78 2415.6 49.5 990 170 3400 40 800
0 0 0 0

Testing & Commissioning charges along with


3.2 topping-up of refrigerant & OIL AS REQUIRED Lot 1 167904 167904 5148 5148 165500 165500 60500 60500

0 0
3.3 All Refrigerant Joints each 99 2740 271260 198 19602 3200 316800 550 54450
Total 10280855.2 1157483 10268990 1107385
A 11438338.41 11376375

SR. DESCRIPTION OF ITEMS Daikin Carrier


NO. UoM Qty
supply INSTALLATION supply INSTALLATION
UNIT TOTAL RATE TOTAL UNIT TOTAL RATE TOTAL
RATE UNIT RATE RATE RATE UNIT RATE RATE
Supply, delivery, Installation & testing of SITE
FABRICATED Galvanised Sheet (GI) Ducting class
VIII with M.S. Angle Flange , turning vanes, with
proper duct sealing with RTV food grade
Sealant, rivets , GI nut bolts complete with
supports ,Pressure tested with aqueous base
1.0 smoke generator etc all as per specification.
Duct shall be
pressure tested at 3" static pressure.

1.1 FACTORY FABRICATED DUCTS AS PER


"SMACNA" STANDARDS AND TENDER
SPECIFICTIONS
Daikin Carrier
supply INSTALLATION supply INSTALLATION
SR. UNIT TOTAL UNIT TOTAL
NO. DESCRIPTION OF ITEMS UoM QTY
RATE
TOTAL RATE UNIT RATE RATE RATE
TOTAL RATE UNIT RATE
RATE
a UPTO 750mm (24 gauge ) MT2 76 815 61940 307 23332 950 72200 250 19000
b 751mm -1500mm (22 gauge ) MT 2
60 953 57180 307 18420 1050 63000 320 19200
c 1501mm -2400mm (20 gauge ) MT 2
RO 0 0 1250 350
1.2 SITE FABRICATED DUCTS AS PER "SMACNA"
STANDARDS & TENDER SPECIFICTIONS

a UPTO 750mm (24 gauge ) MT2 8 881 7048 307 2456 950 7600 250 2000
b 751mm -1500mm(22 gauge ) MT 2
6 1019 6114 307 1842 1050 6300 320 1920
C 1501mm -2500mm (20 gauge ) MT 2
RO 0 0

2.0 Air Distribution


2.1 Powder coated Extruded Aluminium air Grilles SQMT 2.6
with volume control dampers. 15537 40396.2 615 1599 7200 18720 1200 3120

3.0 DAMPER
Aluminium Extruded Low Leakage Damper
within ducts to be provided with suitable ducts
lever and clearly marked quadrants for manual
control of volume of air flow and for proper
balancing of the air distribution system(Damper
manufacturer has to submit low leakage
certificate).(Extended shaft of minimum 150mm
3.1 length with GI base plate shall be provided MT2 0.3 10600 3180 1537 461.1 8500 2550 1200 360
wherever required during drawing Approval).

4.0 DUCT INSULATION - MESUREMENT AS PER


DUCT SURFACE AREA
Daikin Carrier
supply INSTALLATION supply INSTALLATION
SR. UNIT TOTAL UNIT TOTAL
NO. DESCRIPTION OF ITEMS UoM QTY
RATE
TOTAL RATE UNIT RATE RATE RATE
TOTAL RATE UNIT RATE
RATE
Thermal insulation of Ducts with Class ‘O’
Plus(FM approved & in accordance to UL
94(HBF, HF 1 & HF 2), 1996) Closed Cell
elastomeric / XLPE Rubber with Aluminum Foil
and antimicrobial and antifungal properties
having thickness of 19 mm for Supply Air Duct as
per the specifications & 13 mm for Return Air
4.1 Duct Insulation. Thermal Conductivity is 0.033
w/m.k and having µ value is ≥ 10000. and
conforming to standard
Specification

a 19 mm thick FOR (SUPPLY AIR DUCT) MT2 190 550 104500 154 29260 590 112100 290 55100
b 13 mm thick FOR (RETURN AIR DUCT) MT 2
RO 0 0 450 290

4.2 Acoustic Insulation with Open Cell Elastomeric


Rubber Material with Antifungal and
Antimicrobial Properties from the inside of duct
as Per Specifications.

a 13 mm thick MT2 70 924 64680 154 10780 650 45500 310 21700

4.3 Fire retardent Canvass Connection Each 4 2271 9084 714 2856 1550 6200 550 2200

Under deck Insulation with 50 mm thick TF grade


Expanded Polystyrene or equivalent
material to get an overall heat transmission
5.0 factor of 0.06 BTU/HR/SFT/°F as per Sq.Mtr 950 453 430350 154 146300 490 465500 190 180500
specifications

784472.2 237306.1 799670 305100


B 1021778.3 1104770

Total (A+B) 12460116.71 12481145