You are on page 1of 3

Apple Tree Building Maintenance Pvt Ltd Project MAX HOUSE C & D PARAPET DAVIT CALCULATION

Office: LG 04, DLF Star Mall, Sec-30, Gurgaon, 122001 Client MAX ESTATES Made by Date Job No
Haryana, India Description CGM 27-7-23 MAX house C&D
PARAPET DAVIT - 1800mm
9560593970 Checked Revision Page No
Originated by APPLE TREE Property of APPLE TREE B M, GURGAON CGM 0 04
L= 1800 mm
900 .

a
mm
230
mm
370

TSL = 439 kg 4.30 kN


.
mm
300

CHS 141.3 6.55 mm Thick - 21.77 kg/m

CHS 114.3 6.02 mm Thick - 16.07 kg/m


mm
350

. Concrete Parapet
mm
100

DESIGN ASSUMPTIONS :

1.) The design conforms to BS 5950; Part-1


2.) The grade of steel conforms to EN 10025 Grade 275
3.) The ultimate load factor assumed is 1.6

Total Suspended Load (Including 25% Impact) " TSL " = 438.795 kg = 4.30 kN

Self-weight of Jib = 21.77 kg / m = 0.21 kN / m

Self-weight of Post = 16.07 kg / m = 0.16 kN / m

Bending Moment @ ' a ' = " Mu " = 1.6 x 4.30 1.80 0.21 1.80 2

= 12.95 kNm (Ultimate)

CHECK FOR JIB SECTION : CHS 141.3 6.55 mm Thick - 21.77 kg/m

Self-weight of Jib = Wj= 21.77 kg/m = 0.21 kN/m

Bending Moment @ ' a ' = " Mb " = (TSL x L)+ (Wj x L2/2))

Mb = 8.09 KNm (Actual)

Wall Thickness ( T ) : 6.55

O.D. of Section( D ) : 141.3

I. D.of Section( d ) : 128.2

Section Modulus ( Z) : (π/32)*((D4-d4)/d)

3
98363.55 mm

Bending Stress (σb) : Mb


Z

2
82.29 N/mm

Page 1 of 5
Apple Tree Building Maintenance Pvt Ltd Project MAX HOUSE C & D PARAPET DAVIT CALCULATION
Office: LG 04, DLF Star Mall, Sec-30, Gurgaon, 122001 Client MAX ESTATES Made by Date Job No
Haryana, India Description CGM 27-7-23 MAX house C&D
PARAPET DAVIT - 1800mm
9560593970 Checked Revision Page No
Originated by APPLE TREE Property of APPLE TREE B M, GURGAON CGM 0 05

2
Design stress (σy) : 355 N/mm (As per BS 5950-1 :1990, Table 6)

Allowable Stress (σa) : σy (As per EN 1808 Std. Cause 6.2.2.1)


COE yield

Where ,
COE yield = Safety coefficeint comapre to yeild limit = 1.5

Allowable Stress (σa) : 355


1.5

2
Allowable Stress (σa) : 236.67 N/mm > 82.29

CHECK FOR JIB SECTION : CHS 141.3 6.55 mm Thick - 21.77 kg/m

Effective Length of Cantilever Jib " le " = 2 x 1800 3600 mm

Section Properties :

Plastic Section Modulus ( Zpl ) : 112 cm3 199.28 cm3 (Allowed)

Moment of Inertia ( Ixx ) : 589 cm4

Wall Thickness ( T ) : 6.02 mm

Outside Diameter of Section( D ) : 141.3 mm

Radius of Gyration ( ry ) : 4.72 cm

Slenderness Ratio " λ " = le = 76.3


ry

Ratio ; = D = 23.47176
T

CHECK FOR DEFLECTION OF JIB

Allowable Deflection : 1 / 180 of Span : 10.0 mm

Deflection at Cantilever tip due to Load : W x L3 + w2 x L3 7.0 mm


3xExI 8xExI

Since the Actual deflection < Allowable deflection

The Jib Section is Satisfactory in Deflection

Page 2 of 5
Apple Tree Building Maintenance Pvt Ltd Project MAX HOUSE C & D PARAPET DAVIT CALCULATION
Office: LG 04, DLF Star Mall, Sec-30, Gurgaon, 122001 Client MAX ESTATES Made by Date Job No
Haryana, India Description CGM 27-7-23 MAX house C&D
PARAPET DAVIT - 1800mm
9560593970 Checked Revision Page No
Originated by APPLE TREE Property of APPLE TREE B M, GURGAON CGM 0 06

CHECK FOR VERTICAL POST: CHS 114.3 6.02 mm Thick - 16.07 kg/m

Bending Moment @ ' a ' = " Mu " = 12.95 kNm (Ultimate)

Axial Load " P " = 1.6 x 4.30 1.8 0.21 1.12 0.16

= 7.78 kN (Vertical - Ultimate)

Effective Length of Column " lce " = 2 x 0.67 1.34 m

Section Properties :

Plastic Section Modulus ( Zcpl ) : 70.4 cm3

Sectional Area ( A ) : 20.4 cm2

Wall Thickness ( Tc ) : 6.02 mm

Outside Diameter of Section( Dc ) : 114.3 mm

Radius of Gyration ( rcy ) : 3.83 cm

Slenderness Ratio " λc " = lce = 35.0


rcy

Ratio ; = Dc = 18.99
Tc

Allowable Bending Strength " pcb " = 275 N / mm2 ( Refer Table (19b), BS 5950, Part-1 )

Allowable Compressive Strength " pcc " = 273 N / mm2 ( Refer Table (27a), BS 5950, Part-1 )

Actual Bending Stress " pcba " = Mu = 12.95 x 103 x 103


Zcpl 70.4 x 103

= 183.96 N / mm2

Actual Compressive Stress " pcca " = P = 7.78 x 103


A 20.4 x 102

= 3.82 N / mm2

Stress Ratio ; pcba pcca


pcb pcc

= 184.0 3.82
275.0 273

= 0.67 0.01

= 0.68 < 1.0

Hence Vertical Post Section is safe in Stress Criteria