Minimum Space Requirements

Minimum Sizes of rooms and their least dimensions:


A. Rooms for human habitations-6.00 square meters with a least dimension
of 2.00 meters
B. Kitchen-3.0 square meters with a least dimension of 1.50 meters
C. Toilet and Bath-1.20 square meters with a least dimension of 0.90 meter.

Minimum Air Space Requirements:


A. School Rooms – 3.00 cubic meters with 1.00 square meter of floor area
per person.
B. Workshops, Factories, and Offices – 12.00 cubic meters of air space per
person.
C. Toilet and Bath- 1.20 square meters with a least dimension of 0.90 meter.

Minimum Ceiling heights for artificially ventilated and


naturally ventilated rooms
A. Ground Floor-2.70.
B. Second Floor-2.40.
C. Succeeding floors-2.10 meters above the finished floor.
D. Mezzanines-shall have a clear ceiling height not less than 1.80 meters
above and below it

Average parking sizes


A. Perpendicular or Diagonal-2.5mx5m
B. Parallel Parking-2.15mx6m
C. Truck or bus parking-3.6mx12m