The document outlines minimum space requirements for rooms including habitable rooms requiring 6 square meters, kitchens 3 square meters, and toilets 1.2 square meters. It also specifies minimum air space requirements such as 3 cubic meters per person for school rooms and 12 cubic meters per person for workplaces. Minimum ceiling heights are listed as 2.7 meters for ground floors down to 2.1 meters for higher floors. Standard parking space dimensions are also provided.
Original Description:
Original Title
Minimum Sizes of Rooms and Their Least Dimensions a. Rooms for Human Habitations-6.00 Square Meters (65 Square Feet) With a Least Horizontal Dimension of 2.00 Meters (6 Feet, 7 Inches) B. Kitchen
The document outlines minimum space requirements for rooms including habitable rooms requiring 6 square meters, kitchens 3 square meters, and toilets 1.2 square meters. It also specifies minimum air space requirements such as 3 cubic meters per person for school rooms and 12 cubic meters per person for workplaces. Minimum ceiling heights are listed as 2.7 meters for ground floors down to 2.1 meters for higher floors. Standard parking space dimensions are also provided.
The document outlines minimum space requirements for rooms including habitable rooms requiring 6 square meters, kitchens 3 square meters, and toilets 1.2 square meters. It also specifies minimum air space requirements such as 3 cubic meters per person for school rooms and 12 cubic meters per person for workplaces. Minimum ceiling heights are listed as 2.7 meters for ground floors down to 2.1 meters for higher floors. Standard parking space dimensions are also provided.
Minimum Sizes of rooms and their least dimensions:
A. Rooms for human habitations-6.00 square meters with a least dimension of 2.00 meters B. Kitchen-3.0 square meters with a least dimension of 1.50 meters C. Toilet and Bath-1.20 square meters with a least dimension of 0.90 meter.
Minimum Air Space Requirements:
A. School Rooms – 3.00 cubic meters with 1.00 square meter of floor area per person. B. Workshops, Factories, and Offices – 12.00 cubic meters of air space per person. C. Toilet and Bath- 1.20 square meters with a least dimension of 0.90 meter.
Minimum Ceiling heights for artificially ventilated and
naturally ventilated rooms A. Ground Floor-2.70. B. Second Floor-2.40. C. Succeeding floors-2.10 meters above the finished floor. D. Mezzanines-shall have a clear ceiling height not less than 1.80 meters above and below it
Average parking sizes
A. Perpendicular or Diagonal-2.5mx5m B. Parallel Parking-2.15mx6m C. Truck or bus parking-3.6mx12m