You are on page 1of 1

DOC.NO.

QC-FORM--06
REV.NO. 0
CUBE TEST REPORT
DATE OF REV . 0
PAGE 1 OF 1

Customer Name : M&M FOUNDATION Date of Casting : 26.12.2023

Location : FLENDER Date of Testing : 23.01.2024

Grade of Concrete : M25

Age In Weight ( Compressive Avg Compressive


Sl No ID Mark on Cube Dimension ( cm ) Load ( KN)
Days Kgs ) Strength ( Mpa ) Strength ( Mpa )
M&M
1 8.310 15 X 15 X 15 700 31.11
FOUNDATION

2 M25 28 8.340 15 X 15 X 15 733 32.58 31.91

3 26.12.2023 8.270 15 X 15 X 15 721 32.04

Remarks :All the cubes were taken at Site. Curing & Testing done at Hi Tech Concrete plant lab.

M&M FOUNDATION Checked & Certified By


QC Incharge

You might also like